Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WAVEGUIDES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Final Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have developed a continuum electromechanics model of the microwave resonant cavity transducer performance. The deflection of the membrane is calculated using equations from the theory of plates and shells for deflection of radially constrained thin circular disk under uniform load. The microwave frequency shift is calculated using the equations from the microwave cavity perturbation theory. The transducer model was validated with proof-of-concept experimental data of water flow sensing with a Brass 360 right circular cylinder with 22.2mm diameter and 203µm thick wall. The cavity was excited through a subwavelength hole in TE 011 mode with resonant frequency f ≈ 17.8GHz. Subsequently, we have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment. For this test, we have developed a cylindrical resonator with the same dimensions as for the Brass 360 cavity. The resonator for high temperature liquid sodium test was machined from stainless steel 316 and electroplated with silver on the interior surfaces. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. The sodium flow sensing study was performed in a liquid sodium vessel at 340°C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred kHz was observed. The transducer was removed after 70 days of testing. No visual damage was observed, and the electromagnetic response remained the same. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Water flow sensing was performed before and after liquid sodium test. The responses in both cases are similar and agree with COMSOL computer simulations. Because long-term (multi-year) experimental tests of transducer resilience to harsh environment are not practical, we have developed a probabilistic model of creep to estimate transducer resilience to the harsh environment. The probabilistic model considers diffusion creep under the condition of high temperature and low stress, where the stress and temperature are allowed to be random variables with Gaussian distributions. Using the probabilistic model, we estimate inelastic membrane deflections due to creep for several temperature ranges. We conclude that for temperatures less than 650°C, creep has negligible long-term effect on the transducer performance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An OVERVIEW of MICROPHONICS in CEBAF and CURRENT MODERATION TECHNIQUES

Superconducting RF (SRF) structures are susceptible to frequency detuning from external vibrations and modal mechanical resonances in the structure. These small disturbances, known as microphonics, require additional RF power in CW accelerating structures since the frequency is constantly shifting. In the Jefferson Lab CEBAF accelerator, time and frequency data of this frequency shift have been recorded for many years, allowing a retrospective analysis of different microphonics-mitigation techniques. Some of these techniques are specific to the design of each CEBAF cryomodule, for example implementing BNNT damping material on the cavity string. Other techniques are universal such as affixing vacuum lines and reinforcing waveguide structures.

Powers, Tom↗

High-Quality Factor Microwave Resonators using Rhenium

Coplanar waveguide resonators are a perfect tool to evaluate the losses induced by defects and interfaces in superconducting devices. Even if niobium is the most used superconductor for resonators and qubits, its native oxide at the metal-air (MA) interface limits the device results. Tantalum has recently significantly improved qubit performances due to a thinner and less disordered oxide layer compared to Nb. To further improve the MA interface, we used rhenium, a superconducting material with 1.7 K critical temperature resistant to oxidation: it forms an oxide layer thinner than 1 nm. In this study, we will present a thorough investigation of rhenium CPW resonator measurements with internal quality factors at the single photon level exceeding 2 million. The devices have been fabricated on a sapphire substrate while the processing parameters have been varying and optimized. The measurements have been performed as a function of power and temperature to disentangle different sources of losses, such as two-level systems (TLS) and quasi-particles. A peculiar TLS temperature dependence has been measured and analyzed. In this work, we also vary the participation ratio of the devices to extract the losses introduced by the involved interfaces with higher fidelity and precision. We carried on a deep material characterization effort to link the results to the differences in the fabrication steps, and we will present material characterization measurements performed via AFM, ToF-SIMS, XPS, and TEM.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Computational Prediction of Infrasound Arrival Times and Directions from Stationary and Moving Impulsive Sources

This report addresses the need to predict infrasound signal arrival times and back azimuths at monitoring stations, enabling more focused and efficient searches within recorded waveform data. The primary challenge is estimating expected signal arrival windows for stationary and moving acoustic sources, such as chemical explosions, volcanic eruptions, meteoroids, and spacecraft re-entry events. To address this challenge, a reproducible methodology is described that uses simplified propagation speeds for boundary layer, tropospheric, stratospheric, and thermospheric atmospheric waveguides. While the Python source code itself is not freely available, this document provides detailed, step-by-step instructions, and equations enabling users to replicate and adapt the method independently. The method reliably predicts signal arrival intervals and back azimuths, thereby supporting rapid detection and accurate interpretation of infrasound events. Results demonstrate that this method effectively identifies plausible signal arrival intervals and directions, facilitating faster event detection and more reliable interpretation. This methodology directly supports atmospheric monitoring, planetary defense, and forensic analysis of explosive atmospheric events.

47 OTHER INSTRUMENTATION↗

Systematic study of radioluminescence and light propagation effects in scintillating nanoguide materials

Nanoguide optical waveguides are thermally processed materials based on polymers that have different refractive indices. Scintillating versions of these materials have been under development since 2019 and feature PMMA as the low refractive index constituent and Organic Glass Scintillator-polymer blends as the high index component. Characterization efforts to date have focused on the functional characteristics of nanoguide pertaining to its envisioned use in high-resolution transmission radiography applications.

36 MATERIALS SCIENCE↗

Ultra-high Bandwidth, Ultra-high Dynamic Range X-Ray Shock Characterization via Photonic Integrated Circuit

Nuclear weapon component assessment tests at the Z Machine rely on accurate X-ray yield measurements for model validation, design and analysis of component survivability, and source optimization. Yield measurement devices currently used do not provide the requisite certainty to enable accurate and efficient data analysis of test results, which leads to an increase in Z-shots required for evaluation, longer device development times, and higher operation costs. Additionally, current X-ray flux detectors lack high temporal resolution at the tails. Similarly, shock measurement techniques used for component assessment often lack the ability to spatially resolve wave behavior thereby limiting the ability to measure shock propagation dynamics needed to design the next generation of ND components. Here we present the development of a photonic micro-calorimeter and shock sensor consisting of meter-long waveguide spirals that are optomechanically coupled to X-ray absorbing layers to characterize yield and shock propagation at nanosecond timescales.

42 ENGINEERING↗

COMSOL Simulation of Optical Whispering Gallery Mode (WGM) Resonator

We simulate whispering-gallery mode coupling in a Si$_3$N$_4$--LiNbO$_3$ waveguide--resonator system using 2D and 3D COMSOL models. Results show that the TM$_{00}$ mode couples far more efficiently than TE$_{00}$ due to weaker confinement and stronger evanescent overlap, with critical coupling reached near a 0.20~µm gap. The study highlights polarization dependence, geometric sensitivity, and birefringence as key factors shaping resonant behavior.

42 ENGINEERING↗

COMSOL Simulation of Optical Whispering Gallery Mode (WGM) Resonator

We simulate whispering-gallery mode coupling in a Si$_3$N$_4$--LiNbO$_3$ waveguide--resonator system using 2D and 3D COMSOL models. Results show that the TM$_{00}$ mode couples far more efficiently than TE$_{00}$ due to weaker confinement and stronger evanescent overlap, with critical coupling reached near a 0.20~µm gap. The study highlights polarization dependence, geometric sensitivity, and birefringence as key factors shaping resonant behavior.

Xiaoyu, Chen [Fermilab]↗

INL_Intern_Poster_ColeBailey [Poster]

Understanding the thermophysical properties of molten salts is crucial for the advancement of nuclear fuels. This project presents the design of a custom differential thermal analyzer (DTA) that utilizes non-contact ultrasonic mixing to agitate samples and prevent supercooling. The supercooling effect occurs when a liquid is below its freezing point without solidifying. This can be observed when a liquid in a freezer instantly transitions to its solid phase upon disturbance. By avoiding this effect, accurate transition temperatures of molten salts can be gathered for future applications. Initial mixing results were promising, leading to further refinement of the waveguides using ABAQUS to maximize input energy into the fluid. Future work will focus on integrating both mixing and cooling in conjunctions to observe the avoided effect.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

PROGRESS TOWARDS RF CONDITIONING OF LOW-LOSS COUPLERS FOR A CONDUCTION-COOLED CRYOMODULE

This work presents current progress on the conditioning of two new 25 kW couplers optimized for use in a compact, conduction-cooled SRF cryomodule. A connecting waveguide, previously used for conditioning the 805 MHz SNS couplers, was altered for use at 915 MHz. The necessary modifications were determined via RF modeling, while thermal analysis results identified additional cooling requirements during RF conditioning and provided insight about potential higher-power operation. Initial low-power conditioning will be performed with a 2.5 kW solid-state amplifier, with plans to use an industrial magnetron for RF conditioning at 25 kW in the near future.

Wilson, Christiana [Thomas Jefferson National Acce↗

MULTI-TECHNIQUE CHARACTERIZATION OF SUPERCONDUCTING MATERIALS FOR PARTICLE ACCELERATOR APPLICATIONS

We investigated the performance limitations of superconducting radio-frequency (SRF) cavities and materials using multiple experimental techniques. In particular, this study focuses on understanding the surface properties of nitrogen-doped Nb cavities and super?conducting thin films with higher Tc such as Nb3Sn. The main goal of this work is to use different techniques to better understand each aspect of the complex loss mechanism in superconductors to further improve the already highly efficient SRF cavities. Nitrogen doping applied to a Nb SRF cavity significantly improves the quality factor Q0 compared to a conventional Nb cavity, at an expense of reduced maximum accelerating gradient. The early quench mechanism was analyzed by using temperature maps before and during the quenching. The temperature maps revealed insignificant heating before the quench, and we concluded that nitrogen doping reduces critical magnetic fields in local regions, leading to premature quenching. To understand the origin of the increasing Q0 with the rf field, the density of states (DOS) of cold spots from nitrogen-doped and standard cavities were measured and analyzed using scanning tunneling microscopy. The results suggested that nitrogen doping reduces the spatial inhomogeneity of superconducting properties and shrinks the metallic suboxide layers, which tunes the DOS in such a way as to produce the field-induced reduction in the surface resistance. To characterize SRF thin films, an experimental setup for measuring a coplanar waveguide (CPW) resonator was developed and tested. A surface impedance measurement of the Nb film showed good agreement with the BCS calculation. The preliminary results from measurements of Nb3Sn and NbTiN films are also presented here. The nonlinear Meissner effect was investigated in Nb3Sn film CPW resonators by mea?suring the resonant frequency as a function of a parallel magnetic field. Contrary to a conventional quadratic dependence of the penetration depth ?(B) on the applied magnetic field B, as expected in s-wave superconductors, nearly a linear increase of ?(B) with B was observed. It was concluded that this behavior of ?(B) is due to weakly linked grain bound?aries on the polycrystalline Nb3Sn films, which can mimic the NLME expected in a clean d-wave superconductor.

Makita, Junki↗

Non-Ionizing Millimeter Waves Non-Thermal Radiation of Saccharomyces cerevisiae—Insights and Interactions

Non-ionizing millimeter-waves (MMW) interact with cells in a variety of ways. Here the inhibited cell division effect was investigated using 85–105 GHz MMW irradiation within the International Commission on Non-Ionizing Radiation Protection (ICNIRP) non-thermal 20 mW/cm 2 safety standards. Irradiation using a power density of about 1.0 mW/cm 2 SAR over 5–6 h on 50 cells/μL samples of Saccharomyces cerevisiae model organism resulted in 62% growth rate reduction compared to the control (sham). The effect was specific for 85–105 GHz range and was energy- and cell density-dependent. Irradiation of wild type and Δrad52 (DNA damage repair gene) deleted cells presented no differences of colony growth profiles indicating non-thermal MMW treatment does not cause permanent genetic alterations. Dose versus response relations studied using a standard horn antenna (~1.0 mW/cm 2 ) and compared to that of a compact waveguide (17.17 mW/cm 2 ) for increased power delivery resulted in complete termination of cell division via non-thermal processes supported by temperature rise measurements. We have shown that non-thermal MMW radiation has potential for future use in treatment of yeast related diseases and other targeted biomedical outcomes.

59 BASIC BIOLOGICAL SCIENCES↗

“Seeing Is Believing”—In-Depth Analysis by Co-Imaging of Periodically-Poled X-Cut Lithium Niobate Thin Films

Nonlinear and quantum optical devices based on periodically-poled thin film lithium niobate (PP-TFLN) have gained considerable interest lately, due to their significantly improved performance as compared to their bulk counterparts. Nevertheless, performance parameters such as conversion efficiency, minimum pump power, and spectral bandwidth strongly depend on the quality of the domain structure in these PP-TFLN samples, e.g., their homogeneity and duty cycle, as well as on the overlap and penetration depth of domains with the waveguide mode. Hence, in order to propose improved fabrication protocols, a profound quality control of domain structures is needed that allows quantifying and thoroughly analyzing these parameters. In this paper, we propose to combine a set of nanometer-to-micrometer-scale imaging techniques, i.e., piezoresponse force microscopy (PFM), second-harmonic generation (SHG), and Raman spectroscopy (RS), to access the relevant and crucial sample properties through cross-correlating these methods. Based on our findings, we designate SHG to be the best-suited standard imaging technique for this purpose, in particular when investigating the domain poling process in x-cut TFLNs. While PFM is excellently recommended for near-surface high-resolution imaging, RS provides thorough insights into stress and/or defect distributions, as associated with these domain structures. In this context, our work here indicates unexpectedly large signs for internal fields occurring in x-cut PP-TFLNs that are substantially larger as compared to previous observations in bulk LN.

Reitzig, Sven (ORCID:0000000286970379)↗

ZnO-Au Hybrid Metamaterial Thin Films with Tunable Optical Properties

ZnO-Au nanocomposite thin films have been previously reported as hybrid metamaterials with unique optical properties such as plasmonic resonance properties and hyperbolic behaviors. In this study, Au composition in the ZnO-Au nanocomposites has been effectively tuned by target composition variation and thus resulted in microstructure and optical property tuning. Specifically, all the ZnO-Au nanocomposite thin films grown through the pulsed laser deposition (PLD) method show obvious vertically aligned nanocomposite (VAN) structure with the Au nanopillars embedded in the ZnO matrix. Moreover, the average diameter of Au nanopillars increases as Au concentration increases, which also leads to the redshifts in the surface plasmon resonance (SPR) wavelength and changes in the hyperbolic behaviors of the films. As a whole, this work discusses how strain-driven tuning of optical properties and microstructure resulted through a novel Au concentration variation approach which has not been previously attempted in the ZnO-Au thin film system. These highly ordered films present great promise in the areas of sensing, waveguides, and nanophotonics to name a few.

Bhatt, Nirali A.↗

Optical Processes behind Plasmonic Applications

Plasmonics is a revolutionary concept in nanophotonics that combines the properties of both photonics and electronics by confining light energy to a nanometer-scale oscillating field of free electrons, known as a surface plasmon. Generation, processing, routing, and amplification of optical signals at the nanoscale hold promise for optical communications, biophotonics, sensing, chemistry, and medical applications. Surface plasmons manifest themselves as confined oscillations, allowing for optical nanoantennas, ultra-compact optical detectors, state-of-the-art sensors, data storage, and energy harvesting designs. Surface plasmons facilitate both resonant characteristics of nanostructures and guiding and controlling light at the nanoscale. Plasmonics and metamaterials enable the advancement of many photonic designs with unparalleled capabilities, including subwavelength waveguides, optical nanoresonators, super- and hyper-lenses, and light concentrators. Alternative plasmonic materials have been developed to be incorporated in the nanostructures for low losses and controlled optical characteristics along with semiconductor-process compatibility. This review describes optical processes behind a range of plasmonic applications. It pays special attention to the topics of field enhancement and collective effects in nanostructures. The advances in these research topics are expected to transform the domain of nanoscale photonics, optical metamaterials, and their various applications.

2D materials↗

The real-time data processing and acquisition system for Project 8 Phase II

In Phase II of the Project 8 neutrino mass experiment, electrons from the decays of tritium or 83 m Kr are detected via their ≈ 26GHz cyclotron radiation while contained within a circular waveguide. The signal from a given electron is characterized as a brief chirp, lasting ≲ 10ms and changing in frequency by ≲ 1MHz/ms. To detect these signals, the Project 8 collaboration developed a Data Acquisition (DAQ) system tailored to the signal properties. The DAQ is responsible for simultaneously selecting up to three 100MHz-wide frequency windows to study, detect, and trigger on likely signals from different electron kinetic energies, and for writing the relevant data to disk. We describe the Phase II DAQ system in detail and address how the system was used for data-taking operations.

Ashtari Esfahani, A. [Washington U., Seattle; Shar↗

Progress Towards Developing Neutron Tolerant Magnetostrictive and Piezoelectric Transducers

Current generation light water reactors (LWRs), sodium cooled fast reactors (SFRs), small modular reactors (SMRs), and next generation nuclear plants (NGNPs) produce harsh environments in and near the reactor core that can severely tax material performance and limit component operational life. To address this issue, several Department of Energy Office of Nuclear Energy (DOE-NE) research programs are evaluating the long duration irradiation performance of fuel and structural materials used in existing and new reactors. In order to maximize the amount of information obtained from Material Testing Reactor (MTR) irradiations, DOE is also funding development of enhanced instrumentation that will be able to obtain in-situ, real-time data on key material characteristics and properties, with unprecedented accuracy and resolution. Such data are required to validate new multi-scale, multi-physics modeling tools under development as part of a science-based, engineering driven approach to reactor development. It is not feasible to obtain high resolution/microscale data with the current state of instrumentation technology. However, ultrasound-based sensors offer the ability to obtain such data if it is demonstrated that these sensors and their associated transducers are resistant to high neutron flux, high gamma radiation, and high temperature. To address this need, the Advanced Test Reactor National Scientific User Facility (ATR-NSUF) is funding an irradiation, led by PSU, at the Massachusetts Institute of Technology Research Reactor to test the survivability of ultrasound transducers. As part of this effort, PSU and collaborators have designed, fabricated, and provided piezoelectric and magnetostrictive transducers that are optimized to perform in harsh, high flux, environments. Four piezoelectric transducers were fabricated with either aluminum nitride, zinc oxide, or bismuth titanate as the active element that were coupled to either Kovar or aluminum waveguides and two magnetostrictive transducers were fabricated with Remendur or Galfenol as the active elements. Pulse-echo ultrasonic measurements of these transducers are made in-situ. This paper will present an overview of the test design including selection criteria for candidate materials and optimization of test assembly parameters, data obtained from both out-of-pile and in-pile testing at elevated temperatures, and an assessment based on initial data of the expected performance of ultrasonic devices in irradiation conditions

Reinhardt1, Brian↗