Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Methane Emissions Produced by Pneumatic Devices and Produced Water Tanks on Natural Gas Wellsites

In recent years, more scrutiny has been placed on the release of greenhouse gasses (GHGs) by the oil and gas industry in North America as climate concerns increase. In the coming years, stricter regulations proposed by the Environmental Protection Agency (EPA) concerning the release of GHGs will further direct attention to GHG emissions quantification, modeling, and overall reduction. Active natural gas wellsites employ production equipment that routinely emits methane during normal operation. Production equipment often includes, but is not limited to, gas production units (GPUs), pneumatic controllers (PCs) and actuators powered by produced natural gas, and produced water storage tanks. This work details direct methane emission measurements taken at active natural gas wellsites originating from intermittent pneumatic controllers and produced water storage tanks. Efforts to model methane flows originating from these sources are also detailed, and those results are compared to direct measurement. The direct methane emissions measurement campaign collected flow data from two active dry wellsites in the Marcellus shale region. These measurement campaigns captured, in total, several weeks of continuous data from these sites. Data included multiple pneumatic device vent flowrate channels, a single channel monitoring total emissions vented from the produced water storage tanks, and corresponding site weather data. Periodic composition measurements were taken from flows vented from produced water tanks. Computational modeling efforts attempted to mimic a given site’s methane emissions behavior given limited input parameters. Direct measurement data and simulation data yielded, through reduction and analysis, apparent methane emissions factors, statistics on pneumatic device actuation events, important relationships between GPU parameters and pneumatic device actuation events, produced water storage tank vent flows and flow compositions, and parameters most contributing to the magnitude and frequency of these fugitive methane emissions. Measurements, considering data from a 72hr period, produced PC emissions factors from 0.008 to 0.03 SCFH per device with an average device emitting 0.026 SCFH at the first site. The second site produced PC emissions factors spanning from 0.05 to 25.47 SCFH with an average device emitting 1.93 SCFH not including the 25.47 SCFH device, which was assumed to be malfunctioning. Two unique water tank emission measurements were made, 618 g CH4 per hour and 32.6 g CH4 per hour. On a water basis, the water tank emissions factors were 0.66 and 0.042 kg CH4 per bbl of water, respectively.

03 NATURAL GAS↗

Identifying the Cause of Rupture of Li-Ion Batteries during Thermal Runaway

As the energy density of lithium-ion cells and batteries increases, controlling the outcomes of thermal runaway becomes more challenging. If the high rate of gas generation during thermal runaway is not adequately vented, commercial cell designs can rupture and explode, presenting serious safety concerns. Here, ultra-high-speed synchrotron X-ray imaging is used at >20 000 frames per second to characterize the venting processes of six different 18650 cell designs undergoing thermal runaway. For the first time, the mechanisms that lead to the most catastrophic type of cell failure, rupture, and explosion are identified and elucidated in detail. The practical application of the technique is highlighted by evaluating a novel 18650 cell design with a second vent at the base, which is shown to avoid the critical stages that lead to rupture. The insights yielded in this study shed new light on battery failure and are expected to guide the development of safer commercial cell designs.

25 ENERGY STORAGE↗

Spitzer Orbit Determination During In-orbit Checkout Phase

The Spitzer Space Telescope was injected into heliocentric orbit on August 25, 2003 to observe and study astrophysical phenomena in the infrared range of frequencies. The initial 60 days was dedicated to Spitzer's "In-Orbit Checkout (IOC)" efforts. During this time high levels of Helium venting were used to cool down the telescope. Attitude control was done using reaction wheels, which in turn were de-saturated using cold gas Nitrogen thrusting. Dense tracking data (nearly continuous) by the Deep Space network (DSN) were used to perform orbit determination and to assess any possible venting imbalance. Only Doppler data were available for navigation. This paper deals with navigation efforts during the IOC phase. It includes Dust Cover Ejection (DCE) monitoring, orbit determination strategy validation and results and assessment of non-gravitational accelerations acting on Spitzer including that due to possible imbalance in Helium venting.

helium venting↗

Testing of TVS Augmented Injectors for Tank-to-Tank Transfer of Cryogens

NASA is developing reusable cryogenic systems to enable manned missions to the Moon and Mars. These cryogenic systems will require replenishing cryogens on-orbit via a tanker or propellant depot with minimal loss to boil-off. Three additively manufactured injectors augmented with a Thermodynamic Venting System have been developed for use in tank-to-tank cryogenic fluid transfer. A Vented Chill/No-Vent Fill approach to tank-to-tank transfer has been the industry standard and is explored in this work with emphasis on injector spray patterns and compared to the Charge-Hold-Vent chill method.

Cryogenic Transfer↗

Testing of TVS Augmented Injectors for Tank-to-Tank Transfer of Cryogens

NASA is developing reusable cryogenic systems to enable manned missions to the Moon and Mars. These cryogenic systems will require replenishing cryogens on-orbit via a tanker or propellant depot with minimal loss to boil-off. Three additively manufactured injectors augmented with a Thermodynamic Venting System have been developed for use in tank-to-tank cryogenic fluid transfer. A Vented Chill/No-Vent Fill approach to tank-to-tank transfer has been the industry standard and is explored in this work with emphasis on injector spray patterns and compared to the Charge-Hold-Vent chill method.

Cryogenic Transfer↗

Economics of residential gas furnaces and water heaters in United States new construction market

New single-family home construction represents a significant and important market for the introduction of energy-efficient gas-fired space heating and water-heating equipment. In the new construction market, the choice of furnace and water-heater type is primarily driven by first cost considerations and the availability of power vent and condensing water heaters. Few analysis have been performed to assess the economic impacts of the different combinations of space and water-heating equipment. Thus, equipment is often installed without taking into consideration the potential economic and energy savings of installing space and water-heating equipment combinations. In this study, we use a life-cycle cost analysis that accounts for uncertainty and variability of the analysis inputs to assess the economic benefits of gas furnace and water-heater design combinations. This study accounts not only for the equipment cost but also for the cost of installing, maintaining, repairing, and operating the equipment over its lifetime. Overall, this study, which is focused on US single-family new construction households that install gas furnaces and storage water heaters, finds that installing a condensing or power-vent water heater together with condensing furnace is the most cost-effective option for the majority of these houses. Furthermore, the findings suggest that the new construction residential market could be a target market for the large-scale introduction of a combination of condensing or power-vent water heaters with condensing furnaces.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Life cycle greenhouse gas emissions of hydrogen fuel production from chlor-alkali processes in the United States

By-product hydrogen from chlor-alkali processes can help meet the increasing demand for hydrogen fuel in early fuel cell electric vehicle markets (e.g., California) in the U.S. Hydrogen produced from chlor-alkali plants is typically combusted for process heat on site, vented to the atmosphere (i.e., wasted), or sold to the external merchant hydrogen market. Whether it is combusted, vented, or sold as a commodity, relevant information is lacking as to the life-cycle environmental benefits or trade-offs of using by-product hydrogen from chlor-alkali plants. A life-cycle analysis framework was employed to evaluate well-to-gate greenhouse gas (GHG) emissions associated with by-product hydrogen from chlor-alkali processes in comparison with hydrogen from the conventional centralized natural gas steam methane reforming (central SMR) pathway. U.S.-specific, plant-by-plant, and up-to-date chlor-alkali production characteristics were incorporated into the analysis. In addition to the venting and combustion scenarios, to deal with the multi-functionality of the chlor-alkali processes that simultaneously produce chlorine, sodium hydroxide, and hydrogen, two different co-product allocation strategies were adopted mass allocation and market value allocation. It was estimated that by-product hydrogen production from chlor-alkali processes creates 1.3-9.8 kg CO 2 e/kg H 2 of life-cycle GHG emissions on average, which is 20-90% less than the conventional central SMR pathway. The results vary with co-product treatment scenarios, regional electric grid characteristics, on-site power generation, product prices, and hydrogen yield. Despite the variations in the results, it was concluded that the life-cycle GHG emission reduction benefits of using by-product hydrogen from chlor-alkali processes are robust. In conclusion, with a diverse set of scenario analyses, the study developed a comprehensive and detailed life-cycle GHG emissions inventory of the chlor-alkali by-product hydrogen pathway and quantified sensitivity indices in the context of different assumptions and input parameter values.

08 HYDROGEN↗

Transforming polymorphs, melting, and boiling during cookoff of PETN

Transforming polymorphs, melting, and boiling are physical processes that can accelerate decomposition rates during cookoff of PETN and make measurements difficult. For example, splashing liquids from large bubbles filled with decomposition products clog pressure tubing in sealed experiments. Boil over can also extinguish thermal excursions in vented experiments making ignition difficult. For better measurements, we have modified the Sandia Instrumented Thermal Ignition (SITI) experiment to obtain better sealed and vented cookoff data for PETN by reducing the sample size and including additional gas space to prevent clogged tubing and boil over. Ignition times were not affected by 1) increasing the gas space by a factor of 3 in sealed SITI experiments or by 2) venting the decomposition gasses. That is, thermal ignition of PETN is not pressure dependent and the rate-limiting step during PETN decomposition likely occurs in the condensed phase. A simple decomposition model was calibrated using these observations and includes rate acceleration caused by melting and boiling. The model is used to predict internal temperatures, pressurization, and thermal ignition in a wide variety of experiments. Furthermore, the model is also used with SITI data to estimate the previously unreported latent enthalpy (5 J/g) associated with the α (PETN-I) to β (PETN-II) polymorphic phase transformation of PETN.

42 ENGINEERING↗

The pumice raft-forming 2012 Havre submarine eruption was effusive

A long-standing conceptual model for deep submarine eruptions is that high hydrostatic pressure hinders degassing and acceleration, and suppresses magma fragmentation. The 2012 submarine rhyolite eruption of Havre volcano in the Kermadec arc provided constraints on critical parameters to quantitatively test these concepts. This eruption produced a >1 km 3 raft of floating pumice and a 0.1 km 3 field of giant (>1 m) pumice clasts distributed down-current from the vent. We address the mechanism of creating these clasts using a model for magma ascent in a conduit. We use water ingestion experiments to address why some clasts float and others sink. We show that at the eruption depth of 900 m, the melt retained enough dissolved water, and hence had a low enough viscosity, that strain-rates were too low to cause brittle fragmentation in the conduit, despite mass discharge rates similar to Plinian eruptions on land. There was still, however, enough exsolved vapor at the vent depth to make the magma buoyant relative to seawater. Buoyant magma was thus extruded into the ocean where it rose, quenched, and fragmented to produce clasts up to several meters in diameter. We show that these large clasts would have floated to the sea surface within minutes, where air could enter pore space, and the fate of clasts is then controlled by the ability to trap gas within their pore space. We show that clasts from the raft retain enough gas to remain afloat whereas fragments from giant pumice collected from the seafloor ingest more water and sink. The pumice raft and the giant pumice seafloor deposit were thus produced during a clast-generating effusive submarine eruption, where fragmentation occurred above the vent, and the subsequent fate of clasts was controlled by their ability to ingest water.

58 GEOSCIENCES↗

Discriminating Types of Volcanic Electrical Activity: Toward an Eruption Detection Algorithm

Abstract We present a method for classification of the two distinct types of electrical activity that occur during an explosive volcanic eruption: vent discharges and lightning. Vent discharges occur at the onset of an explosion and create a distinctive radio frequency signature called continual radio frequency. Seconds to minutes after the onset of the eruption, lightning begins to occur throughout the eruption column. We use logistic regression to classify a radio frequency impulse as being part of either a lightning flash or a period of continual radio frequency. The classifier uses the number of peaks in the amplitude envelope from 1 ms windows before and after the impulsive very high frequency waveform, with an average accuracy of 97.9%. We propose that this method could be used in an algorithm to determine when explosive eruptions occurred by identification of the distinctive signatures of vent discharges and lightning.

58 GEOSCIENCES↗

Brockarchaeota, a novel archaeal phylum with unique and versatile carbon cycling pathways

Geothermal environments, such as hot springs and hydrothermal vents, are hotspots for carbon cycling and contain many poorly described microbial taxa. Here, we reconstructed 15 archaeal metagenome-assembled genomes (MAGs) from terrestrial hot spring sediments in China and deep-sea hydrothermal vent sediments in Guaymas Basin, Gulf of California. Phylogenetic analyses of these MAGs indicate that they form a distinct group within the TACK superphylum, and thus we propose their classification as a new phylum, ‘Brockarchaeota’, named after Thomas Brock for his seminal research in hot springs. Based on the MAG sequence information, we infer that some Brockarchaeota are uniquely capable of mediating non-methanogenic anaerobic methylotrophy, via the tetrahydrofolate methyl branch of the Wood-Ljungdahl pathway and reductive glycine pathway. The hydrothermal vent genotypes appear to be obligate fermenters of plant-derived polysaccharides that rely mostly on substrate-level phosphorylation, as they seem to lack most respiratory complexes. In contrast, hot spring lineages have alternate pathways to increase their ATP yield, including anaerobic methylotrophy of methanol and trimethylamine, and potentially use geothermally derived mercury, arsenic, or hydrogen. Their broad distribution and their apparent anaerobic metabolic versatility indicate that Brockarchaeota may occupy previously overlooked roles in anaerobic carbon cycling.

54 ENVIRONMENTAL SCIENCES↗

Indoor air quality in 24 California residences designed as high-performance homes

Today’s high performance green homes are reaching previously unheard of levels of airtightness and are using new materials, technologies and strategies, whose impacts on Indoor Air Quality (IAQ) cannot be fully anticipated from prior studies. This research study used pollutant measurements, home inspections, diagnostic testing and occupant surveys to assess IAQ in 24 new or deeply retrofitted homes designed to be high performance green buildings in California. Although the mechanically vented homes were six times as airtight as non-mechanically ventilated homes (medians of 1.1 and 6.1 ACH 50 , n=11 and n=8, respectively), their use of mechanical ventilation systems and possibly window operation meant their median air exchange rates were almost the same (0.30 versus 0.32 hr -1 , n=8 and n=8, respectively). Pollutant levels were also similar in vented and unvented homes. In addition, these similarities were achieved despite numerous observed faults in complex mechanical ventilation systems. More rigorous commissioning is still recommended. Cooking exhaust systems were used inconsistently and several suffered from design flaws. Failure to follow best practices led to IAQ problems in some cases. Ambient nitrogen dioxide standards were exceeded or nearly so in four homes that either used gas ranges with standing pilots, or in Passive House-style homes that used gas cooking burners without venting range hoods. Homes without active particle filtration had particle count concentrations approximately double those in homes with enhanced filtration. The majority of homes reported using low-emitting materials; consistent with this, formaldehyde levels were approximately half those in conventional, new CA homes built before 2008. Emissions of ultrafine particles (with diameters <100 nm) were dramatically lower on induction electric cooktops, compared with either gas or resistance electric models. These results indicate that high performance homes can achieve acceptable and even exceptional IAQ by providing adequate general mechanical ventilation, using low-emitting materials, providing mechanical particle filtration, incorporating well-designed exhaust ventilation for kitchens and bathrooms, and educating occupants to use the kitchen and bath ventilation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computational Fluid Dynamics Simulations to Assess Spatial Variability and Optimal Ventilation Scenarios for Biological Laboratory Exposures

A significant amount of uncertainty exists regarding potential human exposure to laboratory biomaterials and organisms in Biosafety Level 2 (BSL-2) research laboratories. Computational fluid dynamics (CFD) modeling is proposed as a way to better understand potential impacts of different combinations of biomaterials, laboratory manipulations, and exposure routes on risks to laboratory workers. Here, in this study, we use CFD models to simulate airborne concentrations of contaminants in an actual BSL-2 laboratory under different configurations. Results show that ventilation configuration, sampling location, and contaminant source location can significantly impact airborne concentrations and exposures. Depending on the source location and airflow patterns, the transient and time-integrated concentrations varied by several orders of magnitude. Contaminant plumes from sources located near a return vent (or exhaust like a fume hood or ventilated biosafety cabinet) are likely to be more contained than sources that are further from the exhaust. Having a direct flow between the source and the exhaust (through-flow condition) may reduce potential exposures to individuals outside the air flow path. Designing a BSL-2 room with ventilation and airflow patterns that maximize through-flow conditions to the return/exhaust vents and minimize dispersion and mixing throughout the room is, therefore, recommended. CFD simulations can also be used to assist in characterizing the impacts of supply and return vent locations, room layout, and source locations on spatial and temporal contaminant concentrations. In addition, proper placement of particle sensors can also be informed by CFD simulations to provide additional characterization and monitoring of potential exposures in BSL-2 facilities.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Pressurization Analysis for Heating of a Screw Top Utility Can Loaded With Plutonium Oxide Powder by a 1273 K Fire

The documented safety analysis for the Savannah River National Laboratory (SRNL) evaluates the consequences of a postulated 1273 K fire in a glovebox. The radiological dose consequences for a pressurized release of plutonium oxide powder during such a fire depend on the maximum pressure that is attained inside the oxide storage containers. The oxide storage configuration selected for analysis is can/bag/can, comprised of oxide powder inside an 8.38 × 10 -6 m 3 stainless steel B vial inside 0.006 kg of polyethylene bagging inside a one-quart screw top utility can of the type commonly used to package solvents or rubber cements. To enable evaluation of the dose consequences, temperature and pressure transients have been calculated for exposure of a typical set of storage containers to the fire. The pressurization analysis credits venting to and from the B vial but does not credit venting or leakage from the can. Due to the low rate of venting from the B vial into the can gas space, the can pressure is nearly independent of the B vial pressure. Calculated maximum pressures are compared to the utility can burst pressure. In lieu of a structural analysis of the utility cans, burst pressures and leakage rates were measured using compressed nitrogen gas. The measured gauge burst pressure was 0.250 ± 0.043 MPa. The measured burst pressures are lower than the calculated maximum pressure due to fire exposure, indicating that the utility cans could burst during exposure to a 1273 K fire.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

CHARACTERIZATION OF DWPF MELTER OFF-GAS QUENCHER SAMPLE

The Savannah River National Laboratory (SRNL) recently received a deposit sample from the Melter Primary Off Gas System (POG) of the Defense Waste Processing Facility (DWPF). This sample was composed of material that had been collected while the quencher was in operation January 27, 2011 through March 31, 2011. DWPF requested, through a technical assistance request, characterization of the melter off-gas deposits by x-ray diffraction (XRD), scanning electron microscopy (SEM), and chemical analysis. The purpose of the Melter Off-Gas System is to reduce the amount of radioactive particles and mercury in the gases vented to the atmosphere. Gases emitted from the melter pass through the primary film cooler, quencher, Off-Gas Condensate Tank (OGCT), Steam Atomized Scrubbers (SAS), a condenser, a high efficiency mist eliminator, and a high efficiency particulate air filter, before being vented to the Process Vessel Vent System. The film coolers cool the gases leaving the melter vapor space from {approx}750 C to {approx}375 C, by introducing air and steam to the flow. In the next step, the quencher cools the gas to about 60 C by bringing the condensate from the OGCT in contact with the effluent (Figure 1). Most of the steam in the effluent is then condensed and the melter vapor space pressure is reduced. The purpose of the OGCT is to collect and store the condensate formed during the melter operation. Condensate from the OGCT is circulated to the SAS and atomized with steam. This atomized condensate is mixed with the off-gas to wet and join the particulate which is then removed in the cyclone. The next stage incorporates a chilled water condenser which separates the vapors and elemental mercury from the off-gas steam. Primary off-gas deposit samples from the DWPF melter have previously been analyzed. In 2003, samples from just past the film cooler, from the inlet of the quencher and inside the quencher were analyzed at SRNL. It was determined that the samples were a mixture of sludge and glass frit. The major component was Si along with Fe, Al, and other elements in the radioactive waste being processed. The deposits analyzed also contained U-235 fission products and actinide elements. Prior to that, deposits in the off-gas system in the DWPF nonradioactive half scale melter and the one-tenth scale integrated DWPF melter system were analyzed and determined to be mixtures of alkali rich chlorides, sulfates, borates, and fluorides entrained with iron oxides, spinels and frit particles formed by vapor-phase transport and condensation. Additional work was performed in 2007 in which researchers similarly found the deposits to be a combination of sludge and frit particles.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of CTBT OSI Radionuclide Techniques at the DILUTED WATERS Nuclear Test Site

Under the Comprehensive Nuclear-Test-Ban Treaty (CTBT), a verification regime that includes the ability to conduct an On-Site Inspection (OSI) will be established. The Treaty allows for an OSI to include many techniques, including the radionuclide techniques of gamma radiation surveying and spectrometry and environmental sampling and analysis. Such radioactivity detection techniques can provide the “smoking gun” evidence that a nuclear test has occurred through the detection and quantification of indicative recent fission products. An OSI faces restrictions in time and manpower, as dictated by the Treaty; not to mention possible logistics difficulties due to the location and climate of the suspected explosion site. It is thus necessary to have a good understanding of the possible source term an OSI will encounter and the proper techniques that will be necessary for an effective OSI regime. One of the challenges during an OSI is to locate radioactive debris that has escaped an underground nuclear explosion (UNE) and settled on the surface near and downwind of ground zero. To support the understanding and selection of sampling and survey techniques for use in an OSI, we are currently designing an experiment, the Particulate Release Experiment (PRex), to simulate a small-scale vent from an underground nuclear explosion. PRex will occur at the Nevada National Security Site (NNSS). The project is conducted under the National Center for Nuclear Security (NCNS) funded by the National Nuclear Security Agency (NNSA). Prior to the release experiment, scheduled for Spring of 2013, the project scheduled a number of activities at the NNSS to prepare for the release experiment as well as to utilize the nuclear testing past of the NNSS for the development of OSI techniques for CTBT. One such activity—the focus of this report—was a survey and sampling campaign at the site of an old UNE that vented: DILUTED WATERS. Activities at DILUTED WATERS included vehicle-based survey, in situ measurements with high-purity germanium (HPGe) and hand-held LaBr 3 systems, soil sampling with a variety of tools, and laboratory gamma spectrometric analysis of those samples. A further benefit of the measurement campaign was to gain familiarity with the many logistical aspects of performing radiological field work at NNSS ahead of the PRex. Many practical lessons concerning the proper methodologies and logistics of using the surveying and sampling equipment were noted. These Lessons Learned are compiled together in Appendix A. The vehicle-based survey was successful in that it found a previously unknown hotspot (determined to be 232 Th) while it demonstrated that a better method for keeping a serpentine track without staking was needed. Some of the soil sampling equipment was found to be impractical for the application, though core sampling would not be the correct way to take soil samples for a fresh vent deposit (as opposed to an old site like DILUTED WATERS). Due to the site’s age, 137 Cs was the only fission radioisotope identified, though others were searched for. While not enough samples were taken and analyzed to definitively link the 137 Cs to DILUTED WATERS as opposed to other NNSS activities, results were consistent with the historical DILUTED WATERS plume. MDAs were compared for soil sampling and in situ measurements.

CTBT↗

Pollutant exposures from unvented gas cooking burners: A Simulation-based Assessment for Southern California

Residential natural gas cooking burners (NGCBs) can emit substantial quantities of pollutants, and they are typically used without venting range hoods. In this study, LBNL researchers quantified pollutant concentrations and occupant exposures resulting from NGCB use in California homes.The simulation model estimated that—in homes using NGCBs without coincident use of venting range hoods -- 62%, 9%, and 53% of occupants are routinely exposed to NO 2 , CO, and HCHO levels that exceed acute health-based standards and guidelines. NGCB use increased the sample median of the highest simulated 1-hr indoor concentrations by 100, 3,000, and 20 ppb for NO 2 , CO, and HCHO, respectively. The study recommends that reducing pollutant exposures from NGCBs should be a public health priority. Simulation results suggest that regular use of even moderately effective venting range hoods would dramatically reduce the percentage of homes in which concentrations exceed health-based standards.

03 NATURAL GAS↗

Field Testing Unvented Roofs with Asphalt Shingles in Cold and Hot-Humid Climates

Test houses with unvented roof assemblies were built to measure long-term moisture performance, in the Chicago area (5A) and the Houston area (2A). The Chicago-area test bed had seven experimental rafter bays, including a control vented compact roof, and six unvented roof variants with cellulose or fiberglass insulation. The interior was run at 50% RH. The Houston-area roof was an unvented attic insulated with spray-applied fiberglass. Most ridges and hips were built with a diffusion vent detail, capped with vapor permeable roof membrane. In contrast, the diffusion vent roofs had drier conditions at the roof peak in wintertime, but during the summer, RHs and MCs were higher than the unvented roof (albeit in the safe range).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗