Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Time Projection Chamber”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Beyond the Standard Model New Physics Searches with SBND

SBND (Short-Baseline Near Detector) is a 112-ton liquid argon time projection chamber located on the Booster Neutrino Beam at Fermi National Accelerator Laboratory, and is the near detector of the Short-Baseline Neutrino program. The primary goals of SBND are to provide flux constraints for sterile neutrino searches, conduct world-leading neutrino cross-section measurements on argon, and perform Beyond the Standard Model (BSM) new physics searches with its high-precision particle identification capabilities. SBND’s prospects and tools for detecting a variety of BSM phenomena produced in a neutrino beam, such as sub-GeV dark matter, dark neutrinos, heavy neutral leptons and millicharged particles, are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quality assurance and quality control of the $26~\text {m}^2$ SiPM production for the DarkSide-20k dark matter experiment

DarkSide-20k is a novel liquid argon dark matter detector currently under construction at the Laboratori Nazionali del Gran Sasso (LNGS) of the Istituto Nazionale di Fisica Nucleare (INFN) that will push the sensitivity for Weakly Interacting Massive Particle (WIMP) detection into the neutrino fog. The core of the apparatus is a dual-phase Time Projection Chamber (TPC), filled with 50 tonnes of low radioactivity underground argon (UAr) acting as the WIMP target. NUV-HD-cryo Silicon Photomultipliers (SiPM)s designed by Fondazione Bruno Kessler (FBK) (Trento, Italy) were selected as the photon sensors covering two $10.5~\text {m}^2$ Optical Planes, one at each end of the TPC, and a total of $5~\text {m}^2$ photosensitive surface for the liquid argon veto detectors. This paper describes the Quality Assurance and Quality Control (QA/QC) plan and procedures accompanying the production of FBK NUV-HD-cryo SiPM wafers manufactured by LFoundry s.r.l. (Avezzano, AQ, Italy). SiPM characteristics are measured at 77 K at the wafer level with a custom-designed probe station. As of March 2025, 1314 of the 1400 production wafers (94% of the total) for DarkSide-20k were tested. The wafer yield is $93.2\pm 2.5$%, which exceeds the 80% specification defined in the original DarkSide-20k production plan.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Short-Baseline Near Detector at Fermilab: Input to the European Strategy for Particle Physics 2026 Update

SBND is a 112 ton liquid argon time projection chamber (LArTPC) neutrino detector located 110 meters from the Booster Neutrino Beam (BNB) target at Fermilab. Its main goals include searches for eV-scale sterile neutrinos as part of the Short-Baseline Neutrino (SBN) program, other searches for physics beyond the Standard Model, and precision studies of neutrino-argon interactions. In addition, SBND is providing a platform for LArTPC neutrino detector technology development and is an excellent training ground for the international group of scientists and engineers working towards the upcoming flagship Deep Underground Neutrino Experiment (DUNE). SBND began operation in July 2024, and started collecting stable neutrino beam data in December 2024 with an unprecedented rate of ~7,000 neutrino events per day. During its currently approved operation plans (2024-2027), SBND is expected to accumulate nearly 10 million neutrino interactions. The near detector dataset will be instrumental in testing the sterile neutrino hypothesis with unprecedented sensitivity in SBN and in probing signals of beyond the Standard Model physics. It will also be used to significantly advance our understanding of the physics of neutrino-argon interactions ahead of DUNE. After the planned accelerator restart at Fermilab (2029+), opportunities are being explored to operate SBND in antineutrino mode in order to address the scarcity of antineutrino-argon scattering data, or in a dedicated beam-dump mode to significantly enhance sensitivity to searches for new physics. SBND is an international effort, with approximately 40% of institutions from Europe, contributing to detector construction, commissioning, software development, and data analysis. Continued European involvement and leadership are essential during SBND's operations and analysis phase for both the success of SBND, SBN and its role leading up to DUNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Recent results from MicroBooNE

Modelling and reconstructing neutrino-nucleus scattering is difficult, but it is crucial to do it precisely to enable next-generation oscillation measurements. Liquid argon time projection chambers (LArTPCs), such as MicroBooNE, can be the tool for this job as they are excellent precision neutrino detectors with their ability to produce detailed three-dimensional interaction images and precise energy and spatial resolution. MicroBooNE currently possesses the world's largest neutrino-argon scattering data set collected over five years using the BNB and NuMI neutrino beams at Fermilab. The experiment has performed measurements over a broad range of physics topics including neutrino argon cross sections, searches for BSM physics, and investigations of the MiniBooNE LEE excess. Many of these measurements are essential for improving the modelling of nuclear effects for both MicroBooNE and future LArTPC neutrino experiments, such as DUNE. This talk will give an overview of recent MicroBooNE results, the analysis techniques that enable them, and prospects for future measurements.

Parkinson, Holly B. [U. Edinburgh (main)] (ORCID:0↗

Characterization of Lateral Amorphous Selenium Photodetectors for Low-Photon and VUV Detection at Cryogenic Temperatures

The performance of amorphous selenium (a-Se) as a cryogenic photodetector material is evaluated through a series of experiments using laterally structured devices operated in a custom optical test stand. These studies investigate the response of a-Se detectors to low-photon fluxes at high electric fields near avalanche conditions, the linearity of the photoconductive response over a wide dynamic range and the direct detection of narrowband 130 nm vacuum ultraviolet (VUV) illumination. At 87 K, matched-filter analysis shows reliable single-shot detection with efficiencies greater than or equal to 80 percent and area under the curve (AUC) greater than or equal to 0.85 using as few as approximately 6800 incident 401 nm photons, corresponding to approximately 3400 photons within field-active regions after accounting for geometric constraints. Measurements are performed at cryogenic temperatures using calibrated photon fluxes derived from a silicon photomultiplier reference and a characterized optical filter stack. Additional experiments using a tellurium-doped a-Se (a-SeTe) device explore the material's behavior under identical test conditions and demonstrate that avalanche is achievable in a-SeTe at cryogenic temperatures. The results demonstrate reproducible low-noise operation, VUV sensitivity and field-dependent gain behavior in a lateral a-Se architecture, representing the first reported observation of avalanche multiplication in laterally structured a-Se and a-SeTe devices at cryogenic temperatures. These findings support the potential integration of laterally structured a-Se devices into next-generation pixelated liquid-argon time projection chambers (TPCs) requiring scalable, high-field-compatible photon detection systems.

FOS: Physical sciences↗

Search for an Anomalous Excess of Single Photons in the MicroBooNE Neutrino Experiment

Neutrinos are some of the most elusive particles in the standard model, being incredibly common throughout the universe, but interacting with detectors incredibly rarely. Certain properties of neutrinos remain difficult to measure, including their masses, their CP violation properties, and whether or not they are their own antiparticles. Additionally, there have been several anomalous results in neutrino experiments which remain unexplained. MicroBooNE was built in order to study these anomalous results using a more capable detector technology, the Liquid Argon Time Projection Chamber. Specifically, MicroBooNE is able to search for an anomalous excess of low energy electromagnetic showers, which was previously observed by the MiniBooNE experiment. In particular, MicroBooNE is able to study whether the excess could consist of electron showers or photon showers. In this thesis, I describe a search for this anomalous excess by targeting neutral current Delta radiative decays, the largest expected source of single photons in MicroBooNE. We observe data consistent with our nominal expectation, but cannot rule out all potential sources of additional single photon events, particularly those with no visible proton activity. There remains significant potential to probe this channel in even more detail using MicroBooNE and other experiments in the near future.Hagaman, Lee

Hagaman, Lee [Chicago U.]↗

First Muon Neutrino on Argon Cross Section Measurements With an Off-Axis Beam

While over ninety years have passed since neutrinos were first predicted in 1930 by Wolfgang Pauli, much about them is still unknown [20]. How many types of neutrinos there are, how precisely neutrinos change flavor, and how neutrinos interact with various types of matter are largely unanswered questions that have implications for fields beyond particle physics, such as cosmology and astrophysics. The final question can be answered partially by differential cross section measurements, two of which constitute the primary result of this thesis. The NeUtrinos at the Main Injector (NuMI) Beam at Fermilab in Batavia, IL provides a source of muon neutrinos and muon antineutrinos to the MicroBooNE experiment, an 85 ton liquid argon time projection chamber (LArTPC). The technology allows for high precision particle tracking and energy reconstruction that can be used to make cross section measurements. Necessary work for making these measurements for which the author of this thesis made an essential contribution is presented in detail in References [21] [22] [11] [23]. The measurement presented in this thesis is made with 2.187e20 Protons on Target (POT), the standard metric for an amount of beam exposure, of data when the beam was in forward horn current mode. Single-differential cross section measurements in terms of muon candidate kinetic energy and direction are made, and their statistical fits with simulation are 5.8 (12 d.o.f.) and 11.4 (10 d.o.f.), respectively. This indicates that the muon kinematics for muon neutrino and muon antineutrino charged-current (CC) events primarily in the energy range [0-3] GeV can be trusted for oscillation experiments, including DUNE, because of the agreement to within the associated systematic and statistical uncertainties between the measurement and the model in every bin of both single-differential cross sections. This result adds to the corresponding result for the Booster Neutrino Beam (BNB) because it covers a completely different energy region than that measurement, a double-differential cross section in terms of muon momentum and direction [14]. This result contributes to reducing the uncertainty in near-far event rate comparisons in long baseline neutrino experiments and also adds to existing knowledge of the neutrino-nucleus interaction by describing the outgoing muon kinematics in interactions of muon neutrinos and muon antineutrinos. This result is the first-ever measurement of differential cross sections of muon neutrinos and muon antineutrinos in liquid argon made with an off-axis beam.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Deep-Learning-Based Muon Neutrino CCQE Selection for Searches Beyond the Standard Model with MicroBooNE

The anomalous Low Energy Excess (LEE) of electron neutrinos and antineutrinos in MiniBooNE has inspired both theories and entire experiments to probe the heart of its mystery. One such experiment is MicroBooNE. This dissertation presents an important facet of its LEE investigation: how a powerful systematic can be levied on this signal through parallel study of a highly correlated channel in muon neutrinos. This constraint serves to strengthen MicroBooNE's ability to confirm or validate the cause of the LEE and will lay the groundwork for future oscillation experiments in Liquid Argon Time Projection Chamber (LArTPC) detector experiments like SBN and DUNE. In addition, this muon channel can be used to test oscillations directly, demonstrated through the world's first muon neutrino disappearance search with LArTPC data.

Cianci, Davio↗

MicroBooNE's First Search for the MiniBooNE Anomalous Excess Under a Photon-Like Hypothesis with High-Sensitivity Search for Neutrino-Induced Neutral Current Delta Production and Radiative Decay

MicroBooNE is a liquid argon time projection chamber that collected neutrino data at Fermilab's Booster Neutrino Beam from 2015 to 2020. One of its primary goals is to investigate the “Low Energy Excess” of neutrino events observed by the MiniBooNE experiment, for which candidate photon-like interpretations include an underestimation of neutrino neutral current (NC) resonant $\Delta$ production with subsequent radiative decay or another anomalous source of single photon production in neutrino interactions. In particular, NC $\Delta$ radiative decay is poorly constrained background process to electron neutrino measurements and could be a sizable contribution to the “Low Energy Excess.” This thesis will present the analysis developed to search for NC $\Delta \rightarrow N\gamma$ events in MicroBooNE, consisting of a boosted decision tree based event selection with an NC neutral pion background constraint, using data from the first three years of operations corresponding to $6.9\times10^{20}$ POT.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A gamma-ray imaging telescope based on liquid xenon

A liquid-xenon time projection chamber (TPC) is discussed in terms of its utility as an imaging telescope for high energy astrophysics. The concept exploits the efficiency of xenon as an ionization and scintillation medium for imaging astrophysical gamma-ray sources. The design fundamentally follows the approach of an ionization calorimeter functioning as a TPC dedicated to 3D tracking. A schematic diagram of the instrument is presented, and the device measures the ionization signals - resulting from gamma-ray interactions with xenon - on collection electrodes. The liquid xenon instrument permits the identification of the direction of the Compton electron and thereby determines the location of the source. The energy region of 1-30 MeV is covered by the instrument, and source localization is possible for the entire range.

Aprile, Elena↗

Development of a High Resolution Liquid Xenon Imaging Telescope for Medium Energy Gamma Ray Astrophysics

In the third year of the research project, we have (1) tested a 3.5 liter prototype of the Liquid Xenon Time Projection Chamber, (2) used a prototype having a 4.4 cm drift gap to study the charge and energy resolution response of the 3.5 liter chamber, (3) obtained an energy resolution as good as that previously measured by us using chambers with drift gaps of the order of millimeters, (4) observed the induction signals produced by MeV gamma rays, (4) used the 20 hybrid charge sensitive preamplifiers for a nondestructive readout of the electron image on the induction wires, (5) performed extensive Monte Carlo simulations to obtain results on efficiency, background rejection capability, and source flux sensitivity, and (6) developed a reconstruction algorithm for events with multiple interaction points.

Aprile, Elena↗

A high resolution liquid xenon imaging telescope for 0.3-10 MeV gamma-ray astrophysics: Construction and initial balloon flights

An instrument is described which will provide a direct image of gamma-ray line or continuum sources in the energy range 300 keV to 10 MeV. The use of this instrument to study the celestial distribution of the (exp 26)Al isotope by observing the 1.809 MeV deexcitation gamma-ray line is illustrated. The source location accuracy is 2' or better. The imaging telescope is a liquid xenon time projection chamber coupled with a coded aperture mask (LXe-CAT). This instrument will confirm and extend the COMPTEL observations from the Compton Gamma-Ray Observatory (CGRO) with an improved capability for identifying the actual Galactic source or sources of (exp 26)Al, which are currently not known with certainty. sources currently under consideration include red giants on the asymptotic giant branch (AGB), novae, Type 1b or Type 2 supernovae, Wolf-Rayet stars and cosmic-rays interacting in molecular clouds. The instrument could also identify a local source of the celestial 1.809 MeV gamma-ray line, such as a recent nearby supernova.

Aprile, Elena↗

The LXeCAT instrument for gamma-ray astrophysics

The Liquid Xenon Coded Aperture Telescope (LXeCAT) and its capability to image astrophysical gamma-ray sources in the MeV region is described. The gamma-ray detector is a Liquid Xenon Time Projection Chamber (LXeTPC) triggered by the primary scintillation light. Effective background rejection is a direct consequence of the intrinsic three-dimensional imaging capability of the LXeTPC. Initial results with a 10 liter prototype confirm an energy resolution of 6% FWHM, a position resolution of 1 mm RMS and a light triggering efficiency higher than 90% for 1 MeV gamma-rays.

Aprile, E.↗

Development of the 3-D Track Imager for Medium and High-Energy Gamma-Ray Telescopes

The Advanced Compton Telescope (ACT) and Advanced Pair Telescope (APT) are envisioned as the next medium (0.3 ^ 50 MeV) and high-energy (30 MeV - greater than 100 GeV) gamma-ray missions. These missions will address many research focus areas of the Structure and Evolution of the Universe Roadmap. These areas include: element formation, matter, energy, & magnetic field interactions in galaxies, AGN & GRB emission, and behavior of matter in extreme environments of black holes & pulsars. Achieving these science goals requires a substantial increases in telescope sensitivity and angular resolution. This talk will discuss how these goals can be met with the three-dimensional track imager (3-DTI), a large volume, low density, time projection chamber with two-dimensional micro-well detector readout and report on our development of a 10 cm x 10 cm x 30 prototype instrument.

Hunter, Stanley D.↗

Neutron Imaging Camera

The Neutron Imaging Camera (NIC) is based on the Three-dimensional Track Imager (3DTI) technology developed at GSFC for gamma-ray astrophysics applications. The 3-DTI, a large volume time-projection chamber, provides accurate, approximately 0.4 mm resolution, 3-D tracking of charged particles. The incident direction of fast neutrons, En > 0.5 MeV, are reconstructed from the momenta and energies of the proton and triton fragments resulting from (sup 3)He(n,p) (sup 3)H interactions in the 3-DTI volume. The performance of the NIC from laboratory and accelerator tests is presented.

Hunter, Stanley↗

A Burst Chasing X-ray Polarimeter

This viewgraph presentation reviews the rationale, design, and importance of an X-Ray Polarimeter. There is a brief discussion of Gamma Ray Bursts, followed by a review of the theories of Gamma-Ray Bursts Polarization. This leads to the question of "How do we measure the polarization?" and a discussion of the GRB x-ray emission, the photoelectric effect and photoelectric polarimetry. The requirements for the work, can only be approached using a gas detector. This leads to a discussion of a Micropattern Gas Polarimeter, and the Time-Projection Chamber (TPC) X-ray Polarimeter.

Hill, Joanne↗

The Advanced Pair Telescope (APT) Mission Concept

We present a mission concept for the Advanced Pair Telescope (APT), a high-energy gamma-ray instrument with an order of magnitude improvement in sensitivity, 6 sr field of view, and angular resolution a factor of 3-10 times that of GLAST. With its very wide instantaneous field-of-view and large effective area, this instrument would be capable of detecting GRBs at very large redshifts, would enable a very high resolution study of SNRs and PWN, and could provide hour-scale temporal resolution of transients from many AGN and galactic sources. The APT instrument will consist of a Xe time-projection-chamber tracker that bridges the energy regime between Compton scattering and pair production and will provide an unprecedented improvement in angular resolution; a thick scintillating-fiber trackerlcalorimeter that will provide sensitivity and energy resolution to higher energies and will possess a factor of 10 improvement in geometric factor over GLAST; and an anticoincidence detector using scintillator-tiles to reject charged particles. After the anticipated 10-years of GLAST operation , the APT instrument would provide continued coverage of the critial high-energy gamma-ray band (between 30 MeV to 100 GeV), providing an essential component of broad-band multiwavelength studies of the high-energy universe.

Hunter, Stanley↗

Gamma-Ray Imaging for Explosives Detection

We describe a gamma-ray imaging camera (GIC) for active interrogation of explosives being developed by NASA/GSFC and NSWCICarderock. The GIC is based on the Three-dimensional Track Imager (3-DTI) technology developed at GSFC for gamma-ray astrophysics. The 3-DTI, a large volume time-projection chamber, provides accurate, approx.0.4 mm resolution, 3-D tracking of charged particles. The incident direction of gamma rays, E, > 6 MeV, are reconstructed from the momenta and energies of the electron-positron pair resulting from interactions in the 3-DTI volume. The optimization of the 3-DTI technology for this specific application and the performance of the GIC from laboratory tests is presented.

deNolfo, G. A.↗