Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thomson”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Compositional Pathways and Capillary Effects during Early-stage Isothermal Precipitation in a Nondilute Ni-Al-Cr Alloy

For a Ni-5.2 Al-14.2 Cr at.% alloy with moderate solute supersaturations, the compositional pathways, as measured with atom-probe tomography, during early to later stage y'(LI2)-precipitation (R = 0.45-10 nm), aged at 873 K, are discussed in light of a multi-component coarsening model. Employing nondilute thermodynamics, detailed model analyses during quasistationary coarsening of the experimental data establish that the y/y' interfacial free-energy is 22- 23+/-7 mJ/sq m. Additionally, solute diffusivities are significantly slower than model estimates. Strong quantitative evidence indicates that an observed y'-supersaturation of Al results from the Gibbs-Thomson effect, providing the first experimental verification of this phenomenon. The Gibbs-Thomson relationship, for a ternary system, as well as differences in measured phase equilibria with CALPHAD assessments, are considered in great detail.

Sudbrack, Chantal K.↗

Two-Phase Cryogenic Heat Exchanger for the Thermodynamic Vent System

A two-phase cryogenic heat exchanger for a thermodynamic vent system was designed and analyzed, and the predicted performance was compared with test results. A method for determining the required size of the Joule-Thomson device was also developed. Numerous sensitivity studies were performed to show that the design was robust and possessed a comfortable capacity margin. The comparison with the test results showed very similar heat extraction performance for similar inlet conditions. It was also shown that estimates for Joule- Thomson device flow rates and exit quality can vary significantly and these need to be accommodated for with a robust system design.

Christie, Robert J.↗

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and two types of cryocoolers to reduce heat load on the He tank, Joule-Thomson and Stirling cryocoolers. Resolve was designed with tunable cryocooler frequencies so that any mechanical interference and its effect on performance could be minimized. Measurements at different cryocooler drive frequencies were used to quantify the interference and narrow the acceptable range of frequency options. For Resolve the choice of cryocooler drive frequencies dramatically influences the instrument performance. Poor choices have been shown to degrade ADR cooling power and degrade the spectroscopic performance of the instrument. However, good choices have been shown to be free of undesirable features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is a critical factor for overall instrument performance. The drive frequencies of the Joule-Thomson cooler operating near 52 Hz, and the Stirling coolers operating near 15 Hz were adjusted in three distinct scan sequences to efficiently narrow the candidate frequency options. The frequency choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. Scans across the drive frequency range of each cryocooler were performed multiple times during ground testing. Surprisingly, the results were not repeatable across test campaigns and did not conform to any discernable trend, but they were repeatable when remeasured within a single cool-down cycle. The conclusion was that the good/bad drive frequencies changed during Dewar warmup/cooldown, and possibly after mechanical vibration tests. Therefore, the settings could not be finalized before launch, and scans during instrument commissioning were necessary. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

Gary A. Sneiderman↗

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and Joule-Thomson and Stirling cryocoolers to reduce heat load on the He tank supporting the ADRs. Resolve was designed with tunable cryocooler drive frequencies so that interference could be avoided. The cryocooler generated micro-vibration changes with drive frequency and that micro-vibration causes interference and degrades instrument performance. Poor drive frequency choices have been shown to dramatically impact ADR cooling power, temperature stability, detector noise, and degrading spectroscopic performance. However, some choices are free of these features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is critical to achieving peak instrument performance. The drive frequencies of the Joule-Thomson cooler, near 52 Hz, and the Stirling coolers, near 15 Hz, were adjusted in three scan sequences while measuring interference to narrow candidate frequency options. Choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. These scans were performed routinely during ground testing. Surprisingly though, the results were not repeatable after the Dewar was warmed and re-cooled but were repeatable when remeasured during the same test campaign. Since the good/bad drive frequencies change during Dewar warmup/cooldown, and possibly after vibration events, the drive frequencies could not be finalized before launch. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

XRISM↗

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and two types of cryocoolers to reduce heat load on the He tank, Joule-Thomson and Stirling cryocoolers. Resolve was designed with tunable cryocooler frequencies so that any mechanical interference and its effect on performance could be minimized. Measurements at different cryocooler drive frequencies were used to quantify the interference and narrow the acceptable range of frequency options. For Resolve the choice of cryocooler drive frequencies dramatically influences the instrument performance. Poor choices have been shown to degrade ADR cooling power and degrade the spectroscopic performance of the instrument. However, good choices have been shown to be free of undesirable features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is a critical factor for overall instrument performance. The drive frequencies of the Joule-Thomson cooler operating near 52 Hz, and the Stirling coolers operating near 15 Hz were adjusted in three distinct scan sequences to efficiently narrow the candidate frequency options. The frequency choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. Scans across the drive frequency range of each cryocooler were performed multiple times during ground testing. Surprisingly, the results were not repeatable across test campaigns and did not conform to any discernable trend, but they were repeatable when remeasured within a single cool-down cycle. The conclusion was that the good/bad drive frequencies changed during Dewar warmup/cooldown, and possibly after mechanical vibration tests. Therefore, the settings could not be finalized before launch, and scans during instrument commissioning were necessary. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

XRISM↗

Role of plasma response in displacements of the tokamak edge due to applied non-axisymmetric fields

Linear, two-fluid, resistive modelling of the plasma response to applied non-axisymmetric fields shows significant displacement of edge temperature and density profiles. The calculated displacements, often of 2 cm or more in H-mode pedestals with parameters appropriate to DIII-D, are due to the helical distortions resulting from stable edge modes being driven to finite amplitude by the applied fields. In many cases, these displacements are greater in magnitude, and different in phase, than the distortions of the separatrix manifolds predicted from vacuum modelling. Comparison of these results with experimental measurements from Thomson scattering and soft x-ray imaging finds good quantitative agreement. In these experiments, the phase of the applied non-axisymmetric magnetic field was flipped or rotated in order to probe the non-axisymmetric features of the response. The poloidal structures measured by x-ray imaging show clear indications of a helical response, as opposed to simply a change in the axisymmetric transport. Inclusion of two-fluid effects and rotation are found to be important in obtaining quantitative agreement with Thomson scattering data. Modelling shows screening of islands in the H-mode pedestal, but island penetration near the top of the pedestal where the electron rotation vanishes in plasmas with co-current rotation. Enhanced transport due to these islands may provide a mechanism for maintaining the pedestal width below the stability threshold of edge-localized modes. For typical DIII-D parameters, it is shown that the linear approximation is often near or beyond the limit of validity in the H-mode edge; however, the general agreement with experimental measurements indicates that these linear results nevertheless maintain good predictive value for profile displacements.

Evans, T. E.↗

Electron Transport in Plasmas with Lithium-Coated Plasma-Facing Components

The Lithium Tokamak Experiment (LTX) is a spherical tokamak designed to study the low-recycling regime through the use of lithium-coated shells conformal to the last closed flux surface (LCFS). A lowered recycling rate is expected to flatten core $T_\mathrm{e}$ profiles, raise edge $T_\mathrm{e}$, strongly affect $n_\mathrm{e}$ profiles, and enhance confinement. To study these unique plasmas, a Thomson scattering diagnostic uses a $\le 20$~J, 30~ns FWHM pulsed ruby laser to measure $T_\mathrm{e}$ and $n_\mathrm{e}$ at 11 radial points on the horizontal midplane, spaced from the magnetic axis to the outer edge at a single temporal point for each discharge. Scattered light is imaged through a spectrometer onto an intensified CCD. The diagnostic is absolutely calibrated using a precision light source and Raman scattering. Measurements of $n_\mathrm{e}$ are compared with line integrated density measurements from a microwave interferometer. Adequate signal to noise is obtained with $n_\mathrm{e} \ge 2 \times 10^{18}\,\mathrm{m^{-3}}$. Thomson profiles of plasmas following evaporation of lithium onto room-temperature plasma-facing components (PFCs) are used in conjunction with magnetic equilibria as input for TRANSP modeling runs. Neoclassical calculations are used to determine $T_\mathrm{i}$ profiles, which have levels that agree with passive charge exchange recombination spectroscopy (CHERS) measurements. TRANSP results for confinement times and stored energies agree with diamagnetic loop measurements. Results of $\chi_\mathrm{e}$ result in values as low as 7 m$^2$/s near the core, which rise to around 100 m$^2$/s near the edge. These are the first measurements of $\chi_\mathrm{e}$ in LTX, or its predecessor, the Current Drive Experiment-Upgrade (CDX-U), with lithium PFCs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulating Thermoelectric Devices Using the MOOSE Framework

Thermoelectric generators (TEG) are devices that generate energy by converting heat into electricity or provide cooling via the Peltier effect. This feature of thermoelectric devices originates from the Seebeck, Peltier, Thomson, and Joule heating effects. TEGs can be applied in energy and thermal management systems such as waste heat recovery and refrigeration, respectively. Thermoelectric device design is influenced by the material selection and the device's geometry operating conditions. Therefore, predicting, verifying, and validating thermoelectric device performance using simulations tools is essential to deploying thermoelectric devices in industry. The Multiphysics Object-Oriented Simulation Environment (MOOSE) Framework is an open-source simulation tool capable of modeling simple to complex systems. In this work, we demonstrate MOOSE's thermoelectric device modeling capabilities by simulating a unicouple, module, and exhaust gas recovery system. The Seebeck, Peltier, Thomson, and Joule heating physics are implemented into MOOSE. The MOOSE thermoelectric physics were thoroughly verified and validated using published COMSOL® results and experimental data. In addition, thermoelectric modules were integrated into an exhaust gas recovery system using the MOOSE MultiApp function as a demonstration of the model's ability. The verification and validation results and exhaust gas heat recovery system showcases MOOSE's capability to model thermoelectric devices and integrate these devices into practical energy systems.

42 - ENGINEERING↗

Development of high gradient laser wakefield accelerators towards nuclear detection applications at LBNL

Compact high-energy linacs are important to applications including monochromatic gamma sources for nuclear material security applications. Recent laser wakefield accelerator experiments at LBNL demonstrated narrow energy spread beams, now with energies of up to 1 GeV in 3 cm using a plasma channel at low density. This demonstrates the production of GeV beams from devices much smaller than conventional linacs, and confirms the anticipated scaling of laser driven accelerators to GeV energies. Stable performance at 0.5 GeV was demonstrated. Experiments and simulations are in progress to control injection of particles into the wake and hence to improve beam quality and stability. Using plasma density gradients to control injection, stable beams at 1 MeV over days of operation, and with an order of magnitude lower absolute momentum spread than previously observed, have been demonstrated. New experiments are post-accelerating the beams from controlled injection experiments to increase beam quality and stability. Thomson scattering from such beams is being developed to provide collimated multi-MeV monoenergetic gamma sources for security applications from compact devices. Such sources can reduce dose to target and increase accuracy for applications including photofission and nuclear resonance fluorescence.

43 PARTICLE ACCELERATORS↗

Phase-transition-induced thermal hysteresis in Type-II weyl semimetals M o T e 2 and M o 1 − x W x T e 2

The resistivity versus temperature measurement is commonly used for identifying temperature-induced phase-change and the resulting hysteresis loop. However, while the resistance is influenced by both the density of states and the carrier lifetimes, the Seebeck coefficient is influenced predominantly by the density of states, and hence is a better probe of the phase of the material. Here, 1T'-T d temperature-induced phase transition in MoTe 2 is studied using temperature-dependent X-ray diffraction, resistivity, and Seebeck coefficient measurements. A more distinct hysteresis is observed when measuring the Seebeck coefficient which is consistent with direct measurements of the crystallographic angle using the temperature-dependent X-ray diffraction. The Seebeck and electrical resistivity measurements indicate a competing contribution of the electrons and holes. The contribution of electron pockets becomes more dominant when molybdenum atoms are replaced by tungsten. In MoTe 2 , a topologically induced enhancement of the Nernst coefficient is observed at low temperatures and a relatively large phase-transition induced Thomson coefficient of 111 μV∙K -1 is measured at 254 K.

36 MATERIALS SCIENCE↗

Compton scattering overview

An overview of linear and nonlinear Compton scattering is presented, along with a comparison with Thomson scattering. Two distinct processes play important roles in the nonlinear regime: multi-photon interactions, leading to the generation of harmonics, and radiation pressure, yielding a downshift of the radiated spectral features. These mechanisms, their influence on the source brightness, and different modeling strategies are also briefly discussed.

42 ENGINEERING↗

Developing a diagnostic for energetic laser-Compton produced photon beams

This paper describes the design and simulation of a radiation detector system for diagnostic measurements of photon beams produced by Thomson or Compton Scattering. The photon beam is Compton scattered in a thin passive converter, and the resulting electrons are analyzed using a charge-coupled device-based tracker and classification algorithms. The flux of the scattered electrons is much lower than that of the photon beam and is additionally dispersed. This dispersal enables measurements while avoiding pileup, which is important in order to provide diagnostic information from intense 'shot’ based pulsed systems, such as those being built to leverage laser wakefield accelerators. Simulations indicate that the designed system is capable of resolving beam parameters from a single shot. The fidelity to which various beam parameters can be resolved is presented as are methods that could result in further improvement to diagnostic resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flux amplification in Helicity Injected Torus (HIT-II) coaxial helicity injection discharges

Recent coaxial helicity injection (CHI) studies using the Helicity Injected Torus device [Redd et al., Phys. Plasmas 9, 2006 (2002)] have produced discharges with measured toroidal plasma currents up to 350 kA and direct evidence of both poloidal flux amplification and toroidal current buildup, resulting from a steady process on millisecond time scales. Internal magnetic probes directly measure the poloidal flux amplification, and also measure a strong paramagnetism. Equilibrium reconstructions of these flux amplification discharges, using only surface magnetics, match the internal probes and multipoint Thomson scattering, and show current-profile relaxation during toroidal current ramp up. The criteria for producing flux amplification include both a sufficiently thin electrode-driven edge region and a large magnetic shear in the CHI injector region, which allows injector reconnection activity to overcome resistive decay and build up a closed plasma core. If the interelectrode distance d is small, then both criteria can be easily met. If d is comparable to the device minor radius, then the injector must be overdriven to produce significant flux amplification. The physics basis for generating CHI discharges with the theoretically maximum toroidal current is now understood, and this basis can be used to guide CHI experiments in any axisymmetric device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three-dimensional modeling of laser-plasma interaction: Benchmarking our predictive modeling tools versus experiments

New experimental capabilities [Froula et al., Phys. Rev. Lett. 98, 085001 (2007)] have been developed to study laser-plasma interaction (LPI) in ignition-relevant condition at the Omega laser facility (LLE/Rochester). By shooting an interaction beam along the axis of a gas-filled hohlraum heated by up to 17 kJ of heater beam energy, a millimeter-scale underdense uniform plasma at electron temperatures above 3 keV was created. Extensive Thomson scattering measurements allowed to benchmark hydrodynamic simulations performed with HYDRA [Meezan et al., Phys. Plasmas 14, 056304 (2007)]. As a result of this effort, these simulations can be used with much confidence as input parameters for the LPI simulation code PF3D [Berger et al., Phys. Plasmas 5, 4337 (1998)]. In this paper, it is shown that by using accurate hydrodynamic profiles and full three-dimensional simulations including a realistic modeling of the laser intensity pattern generated by various smoothing options, whole beam three-dimensional linear kinetic modeling of stimulated Brillouin scattering (SBS) reproduces quantitatively the experimental measurements (SBS thresholds, reflectivity values, and the absence of measurable stimulated Raman scattering). This good agreement was made possible by the recent increase in computing power routinely available for such simulations. These simulations accurately predicted the strong reduction of SBS measured when polarization smoothing is used.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Models comparison for JET polarimeter data

A complete comparison between the theory and the measurements in polarimetry was done by using the Far Infrared Polarimeter at JET. More than 300 shots were analyzed, including a wide spectrum of JET scenarios in all critical conditions for polarimetry: high density, high and very low fields, high temperatures.This work is aimed at the demonstration of the robustness of the theoretical models for the JET polarimeter measurements in the perspective of using these models for ITER like plasma scenarios . In this context, an assessment was performed on how the line-integrated plasma density along the central vertical chord of FIR polarimeter could be evaluated using the Cotton-Mouton effect and its possible concrete use to correct fringe jumps of the interferometer.The models considered are: i) the rigorous numerical solution of the Stokes propagation equations, using dielectric tensor evaluated from JET equilibrium and Thomson scattering [1,2]; ii) two types of approximated solutions [2,3] and iii) the Guenther empirical model [4] that considers the mutual effect between Cotton-Mouton and Faraday rotation angle. The model calculations have been compared with polarimeter measurements for the Cotton-Mouton phase shift.The agreement with theory is satisfactory within the limits of experimental errors [3].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparative studies to the design of the interferometer at W7-X with respect to technical boundary conditions

For the optimisation of the beam line configuration of the multi-channel interferometer at the Wendelstein 7-X stellarator the probabilistic approach of Bayesian experimental design (BED) is applied. Parameters of physical interest are directly implemented as design criteria. The quality of the design is analysed according to its expected information gain (expected utility) about the parameters of interest, which enables one to compare different diagnostic configurations quantitatively. The focus of this work lies on the comparison of different technical approaches for the interferometer diagnostic. Different physical problems (high confinement regimes, neoclassical predictions) and their effect on the density distribution are applied as optimisation goals. The influence of the port system and the in-vessel components (retro-reflectors) is discussed. For this, the design was done with and without technical restrictions, the resulting expected utilities are compared and analysed. Furthermore, the impact of an additional beamline at a different toroidal position (congruent to the Thomson scattering diagnostic) is examined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Temperature and density characteristics of the Helicity Injected Torus-II spherical tokamak indicating closed flux sustainment using coaxial helicity injection

The electron temperature and density profiles of plasmas in the Helicity Injected Torus [HIT-II: T. R. Jarboe et al., Phys. Plasmas 5, 1807 (1998)] experiment are measured by multipoint Thomson scattering (MPTS). The HIT-II device is a small low-aspect-ratio tokamak (major radius 0.3 m, minor radius 0.2 m, toroidal field of up to 0.5 T), capable of inductive ohmic (OH) current drive, Coaxial Helicity Injection (CHI) current drive, or combinations of both. The temperature and density characteristics have been characterized by a ruby laser MPTS diagnostic at up to six locations within the plasma for a single diagnostic time per discharge. Observed hollow temperature profiles of CHI discharges are inconsistent with open flux only predictions for CHI and indicate a closed flux region during CHI current drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ITER LIDAR performance analysis

The core LIDAR Thomson scattering for ITER is specified for core profile measurements with a spatial resolution of 7 cm (a/30) for the range of 500 eV<T{sub e}<40 keV and n{sub e}>3x10{sup 19} m{sup -3} at an accuracy of <10% for T{sub e}. These specifications are verified using a full profile Monte Carlo simulation code. In the simulations it is assumed that the input transmission is 50% and the collection transmission is 10% for {lambda}=300-1200 nm and F/=6-17. A crucial design decision lies on the choice of laser and detector combination. It is evaluated that the system can meet its spatial and accuracy specifications for higher temperatures of T{sub e}>5 keV with a combination of a neodymium-doped yttrium aluminum garnet (Nd:YAG) laser ({lambda}{sub 0}=1064 nm, {delta}{lambda}<1 nm, 5 J, and {delta}t{sub FWHM}=250 ps, 5-10 Hz) and S20, GaAs, and GaAsP microchannel plate photomultipliers ({delta}t{sub FWHM}<300 ps, effective quantum efficiency, EQE=3%-4%, and D=18 mm). In order to reach the required T{sub e} of 500 eV with Nd:YAG first harmonic, this choice requires a development of fast near infrared detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗