Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Impact on Cycle Efficiency of Small CHP Plants from Increasing Firing Temperature Enabled by AM of Turbine Blades

Combined Heat and Power (CHP) systems are gaining popularity because of their potential for high overall thermodynamic efficiency and increased need for distributed power generation. Most CHP systems include a gas turbine for electricity generation and a heat recovery steam generator (HRSG) for steam generation. The steam can be used to power a steam turbine for additional electricity generation or to drive rotating equipment, for space heating, for absorption chillers, etc. A CHP cycle configuration is often driven by the ‘principal’ utility for the facility that it services; steam or electricity. In either case, performance improvements in the gas turbine have the potential to increase the steam and power output from the cycle, which is a direct result of improvements in the gas turbine efficiency and power output. One possible opportunity to improve an existing gas turbine’s performance is to increase the firing temperature with improved turbine cooling and increased compression ratio.<br>In this study, the impact on CHP cycle performance from increasing the turbine firing temperature by 100 °C and improving the turbine blade cooling for a 6-MW scale gas turbine is estimated using an analytical cooled gas turbine model and a steam cycle model. A sensitivity analysis was performed to understand the impact of increasing the internal cooling effectiveness, thermal barrier coating performance and blade material upgrades on gas turbine and CHP cycle efficiency. The impacts of turbine blade cooling improvements were studied for three common CHP cycle configurations identified from the literature. Various definitions for CHP cycle efficiency from the literature are used in the comparisons. The results showed that a 100 °C increase in firing temperature can increase the gas turbine efficiency by 1 percentage point without improving cooling effectiveness and add 2 additional percentage points in efficiency by using advanced turbine blades with higher internal cooling efficiency. Studied engine upgrades showed potential for increasing the CHP cycle efficiency by 3 percentage points while increasing the steam generation rate by 8%.<br>

Uysal, Selcuk Can↗

Leveraging Additive Manufacturing and Coatings for Turbine Thermal Management

This presentation provides an update to the University Turbine Systems Research meeting on research performed at NETL in areas of sCO2 heat transfer for direct cycle power generation and aerothermal research to improve the efficiency and reduce emissions of small gas turbines. Specific topics include a novel test approach to measure the performance of a thermal barrier coating in-situ and fabrication of advanced, additively manufactured airfoils for testing in a high speed cascade.

Searle, Matthew↗

Design and performance assessment of a dual-mode latent thermal storage integrated heat pump across multiple climate zones

The electrification of space cooling and heating systems risks overloading the existing electrical grid during peak hours. Heat pumps integrated with thermal energy storage (HP-TES) offer a promising solution by shifting peak loads to off-peak hours, reducing grid strains. This work presents the design and assessment of a dual-mode HP-TES that uses a single 22°C phase-change material (PCM) as a heat source or sink in heating and cooling modes, respectively. Performance assessment was conducted using Modelica-based transient models, and full-year simulations were conducted across eight US climate zones using typical weather data. Two HP-TES performance metrics: peak energy reduction and recharge energy increases, were defined by comparing HP-TES energy consumption with base HP peak consumptions. Annual heating demand reductions (40–65%) exceeded cooling demand reductions (15–20%) due to the elimination of peak-hour backup heating. Cooling mode recharge energy requirements (0–10%) were reduced in locations with lower summer nighttime temperatures, while heating recharge requirements were lower than the high base-peak energy demand from backup heating. Simplified rapid methods that were 10 7 times faster than annual simulations were developed to predict seasonal cooling and heating energy reductions, and recharge energy requirements, with maximum deviations of ±2.5% and ±3.5% points. These methods enabled rapid parametric studies that identified optimal location-specific PCM temperatures between 22°C and 27°C, highlighting the need to consider both discharge and recharge energy requirements to achieve sustainable, energy-efficient peak load shifting across various climate zones.

25 ENERGY STORAGE↗

Experimental Study on Charging and Discharging Performance of a Dual-Purpose Underground Thermal Battery

A dual-purpose underground thermal battery (DPUTB) was proposed for Grid-interactive Efficient Buildings. It integrates underground thermal energy storage with a shallow-buried ground heat exchanger (less than 6 m deep). The charging and discharging performance of a lab-scale DPUTB were experimentally investigated. The test results show that the lab-scale (1:125 in volume) DPUTB can provide 34 W cooling continuously for 3.7 h with a supply water temperature below 14°C. The water temperature rise of the inner tank was slowed down during the discharging process due to the phase change of the phase change material (PCM). Thermal storage capacity was increased by 156% using the PCM that only occupied 19% volume of the inner tank. The heat lost from the inner tank was recovered in the outer tank and led to the efficiency improvement of a ground source heat pump.

Wang, Lingshi↗

Design and Manufacturing of High Performance, Reduced Charge Heat Exchangers

Air-to-fluid heat exchangers (HXs) play a critical role as the main heat transfer component in Heating, Ventilation, Air-Conditioning, and Refrigeration (HVAC&R) systems. However, their airside thermal resistance significantly inhibits their overall performance. Furthermore, these HXs must be continually more compact to meet the latest refrigerant charge limits to reduce emissions. Recent literature suggests that traditional HX geometries (e.g., round or flat tubes with fins), have reached their limits, and more sophisticated shape- and topology-optimized designs are required to achieve the next jump in performance. This research sheds light on the next generation of air-to-refrigerant HXs and aims to address several practical issues to commercialization such as novelty challenges (improved performance for significant charge reduction; modeling expertise & time investment), manufacturing challenges (non-round tube manufacturing; tube-header integration; product qualification, e.g., burst pressure testing, extreme operational environment, etc.), and operational challenges (flow maldistribution, fouling & wetting, noise & vibration). For example, a >20% improvement on one (or more) HX-level performance metrics (e.g., envelope volume, airside pressure drop, face area, capacity, refrigerant charge, weight, cost, etc.) must be achieved before a HX design is considered for commercialization. We present a new, comprehensive and experimentally validated air-to-refrigerant HX optimization framework with simultaneous thermal-hydraulic performance and mechanical strength considerations for novel, non-round, shape- and topology-optimized tubes capable of optimizing single and two-phase HX designs for any refrigerant choice and performance requirement with significant engineering time savings compared to conventional design practices. The framework was exercised for a wide range of applications and refrigerants, resulting in HXs which achieved greater than 20% improved performance, 20% reductions in size, and 25% reductions in refrigerant charge. To enable non-round tube bundle use in next generation HVAC&R equipment, novel manufacturing techniques were investigated, including the development of conventional manufacturing methods for small diameter, non-round tubes and novel tube-header integration strategies. In total, ten HX prototypes were manufactured, nine using conventional methods directly attributed to this project and one using advanced additive manufacturing methods. The five-year manufacturing feasibility of the proposed HXs was found to have a good outlook. The non-round tube HX simulated performance was validated through comprehensive experimental testing, including nine in-house component-level tests, one independent component-level test at an industry partner laboratory, and in-house system-level tests of using a commercially-available, residential packaged A/C unit which was retrofitted with a non-round tube prototype HX. It was found that HX designs proposed by the new framework can successfully predict experimental thermal-hydraulic performance within ±10-20% the first time with no manual design changes, eliminating the need for time-consuming and expensive prototyping efforts. This work will accelerate design and time to market for next generation HXs while simultaneously facilitating industry transition to new refrigerants at lower charge.

42 ENGINEERING↗

High-Fidelity and High-Performance Computational Simulations for Rapid Design Optimization of Sulfur Thermal Energy Storage (CRADA Report)

NREL and Element 16 collaborated on sulfur thermal energy storage modeling using NREL’s high performance computing (HPC) resources to assist its application in industrial processes. Industrial process heat (IPH) accounts for ~70% of US manufacturing energy use and is primarily produced by fossil fuel combustion. Approximately, 1500 TWht (~60% Terawatt hour thermal) of IPH demand is in the temperature range of 100-300°C. Industrial applications in this temperature range include drying, hydrothermal processing, thermal enhanced oil recovery, food and beverage, bioethanol production, etc. Cost-effective thermal energy storage (TES) that increases the utilization of waste and renewable heat (solar, geothermal, etc.) could provide significant energy savings and reliable heat sources, decrease emissions, and increase US manufacturing competitiveness through reductions in fuel consumption. This HPC4EI project facilitated Element 16’s development of low-cost and high-impact molten sulfur TES for dispatchable IPH. The development of a high-fidelity model validated by experimental data and HPC simulations enabled the successful resolution of the complex interplay between fluid dynamics and heat transfer processes during transient operation of sulfur TES, overcoming the numerical challenges posed by the non-linear temperature-dependent physical properties of sulfur. The project helped accelerate Element 16’s molten sulfur TES product design and support its broad applications.

25 ENERGY STORAGE↗

Influence of Thermal Energy Storage Integration Strategy on System Performance and Refrigerant Charge for Small-Scale R290 Heat Pumps

As small-scale (2.5 – 5 kW) heat pumps across the US increase straining the grid during peak hours, integrated heat pump thermal energy storage (HP-TES) systems can assist by load shifting. However, challenges arise when assembling these systems, as direct refrigerant-phase change material (PCM) heat exchangers (HXs) increase refrigerant charge, and indirect secondary loops degrade HP-TES performance. In this work, direct and indirect HP-TES configurations were sized using commercially available HXs to compare the available load shift time and performance at similar refrigerant charges. For the same indirect 5 kW HP-TES refrigerant charge, directly HP-TES can operate up to 72 and 145 minutes in cooling and heating modes, respectively, using small diameter tubes. Using Modelica, COP increases for direct and indirect HP-TES were 22% and 9%, respectively, given the parasitic losses in the indirect HP-TES. Overall, small-scale direct HP-TES can have comparable refrigerant charges with indirect HP-TES maximizing COP improvements.

25 ENERGY STORAGE↗

SiC Microchannel Heat Sinks for High Heat Flux Dissipation of 1 kW/cm 2

Thermal management has become a major barrier in the development of high-power micro-devices. Microchannel heat sinks (MCHS) are a promising method to dissipate high heat fluxes from high power density devices. Reducing the thermal resistance will reduce the temperature increase of the electronic device, allowing for higher powers to be achieved while maintaining a safe operating temperature. This paper reports on the use of silicon carbide (Sic) microchannels to dissipate high heat fluxes up to 1 kW/cm 2 over a footprint of 0.25 cm 2 . The use of high aspect ratio and decreased hydraulic diameter channels has allowed for very low thermal resistances to be achieved at higher heat duties compared to previous studies. The experiments performed resulted in heater temperatures of less than 60 °C and thermal resistances as low as 0.024 cm 2 . ° $C$/W between the heater surface and fluid inlet temperature. In conclusion, the demonstrated thermal performance of the SiC MCHS is an encouraging means for dissipating heat from high power density microelectronic devices.

42 ENGINEERING↗

Dynamics and chemical mode analysis of plasma thermal-chemical instability

The stability of the weakly ionized plasma and the transition from a stable homogeneous discharge to unstable filaments play an important role in gas laser physics, plasma-assisted combustion, chemical reforming, and material synthesis. Here, theoretical stability analysis and thermal-chemical mode analysis were performed to understand the mechanism of plasma thermal-chemical instability by using a zero-dimensional plasma system with both simplified and detailed chemical kinetics of H 2 /O 2 /N 2 mixtures. The plasma dynamic and kinetic models accounted for multiple physical mechanisms in the chemically-reactive weakly ionized plasma, including ionization, attachment/detachment, recombination, vibrational and electronic energy relaxation, convective and diffusive species/heat removal, Joule heating, and detailed chemical kinetics. An analytical criterion and the explosive mode species/temperature pointers were formulated while the representative active species were identified for different thermal-chemical modes. The results showed that in addition to the classical thermal-ionization mechanism, various chemical modes from chemical heat imbalance and elementary kinetics significantly modified the time dynamics and the stability of the weakly ionized plasma. The present analysis provides insights and guidance to control plasma instability using chemical kinetics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of High-Temperature Bonding Techniques to Enable High-Temperature Static or Dynamic Strain Measurements

Current light-water nuclear reactors rely on a variety of different sensors and sensor applications to meet their structural health monitoring needs throughout the entirety of the reactor primary, secondary, and containment systems. Optical fiber–based sensor technologies could provide solutions to reduce the sensor system footprint while enhancing the measurement fidelity and spatial resolution by leveraging distributed monitoring techniques. Moreover, advanced reactors may require optical fiber–based sensors for structural health monitoring because their operating temperatures will exceed the limits of conventional transducers used to acquire dynamic strain or acoustic data in nuclear power plants. Therefore, this report describes experiments targeting the development of high-temperature bonding techniques that would allow for potentially long lengths of fibers to be bonded to metallic reactor components in advanced reactor systems. The high temperatures experienced within target application, next-generation nuclear reactors, necessitate a high-temperature resistant bond to limit the amount of tension on the fiber at the target application temperature. The primary bonding method investigated in this work is brazing; hot-rolling has also been investigated to a lesser extent. Both techniques are well-suited to bonding optical fibers to large reactor components such as primary coolant piping, pressure vessels, or heat exchangers. Optical frequency domain reflectometry was used to monitor the strain in metal-coated optical fibers before, during, and after the high-temperature bonding process. On select optical fibers that were successfully bonded, additional thermal cycling was performed to assess the extent to which the fiber remained bonded based on the expected thermal expansion of the test specimen material. The results of the various experiments yielded the following general conclusions: (1) brazing is a viable technique for bonding and allows significant compressive strain to be applied to the fiber at room temperature; (2) hot-rolling is a viable technique as well, which has been more optimized than the brazing technique for bonding, but less residual compressive strain has been observed with this technique; and (3) both techniques will need further development and optimization to demonstrate bonding of a long length of fiber that can provably operate at relevant temperatures for an advanced nuclear reactor application.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Performance evaluation of a dynamic wall integrated with active insulation and thermal energy storage systems

Thermal energy storage systems in buildings can store cooling/heating energy during non-peak load hours or when renewable energy sources are available for later use when demanded. Using the building envelope as a thermal battery can help to shave the peak load, reduce the burden in electric grids, and enhance the occupant's thermal comfort. Sensible energy storage on wall systems such as thermally activated building systems can provide an active thermal storage strategy. However, most of the stored energy is used through passive means directed by the thermal lag, which can impede the on-demand release of the stored energy. Integrating active insulation systems with building thermal storage systems can increase the flexibility of charging and discharging time and duration. In this study, a wall system equipped with an active insulation system and thermally activated storage system was designed, and its performance on active cooling energy contribution was studied. The performances of energy storage (charging), release (discharging) of the thermal energy storage energy, and the active insulation system were studied separately and together as an integrated system. Results showed that the thermal properties of the thermal energy storage core material and the pipe spacing of both embedded pipes in the thermal energy storage and hydronic pipes used in the active insulation system affected the wall performance the most out of all the tested wall system parameters. During discharging, the heat flux into the wall was as high as 81.92 W/m 2 . This active insulation system's dynamic R-value varied between less than 1ft 2 •°F•h/BTU (0.18 m 2 •K/W) to 98% of the equally thick foam insulation's R-value.

25 ENERGY STORAGE↗

Efficient Hydraulic-to-electric Energy Conversion for PCM-based Ocean Thermal Gradient Energy System to Power Uncrewed Underwater Vehicles

Since the 2000, there have been numerous investigations into electrical energy storage types that use ocean thermal-to-electricity conversion techniques. Field tests have demonstrated that this technology is feasible for UUVs with long-term missions of over 3,000 km per deployment. Nonetheless, the energy generated by this method is not sufficient to meet the energy requirements of Unscrewed Underwater Vehicles (UUVs). The objective of this study is to design a highly effective ocean thermal gradient energy system to support long-term missions of a UUV. To enhance the performance of the thermal gradient energy system, we have developed a hybrid type (buoyancy regulation and electrical storage). Phase Change Material (PCM)-based energy harvesting system to facilitate efficient UUV operations. A prototype of the hydraulic-to-electric conversion system was implemented, and experimental findings indicate that the hybrid system successfully delivers hydraulic energy for buoyancy change and improved efficiency of hydraulic-to-electric energy conversion, demonstrating its potential as a promising technology for supporting long-term UUV missions.

Deng, Zhiqun↗

Novel Tube Design for Superheater Heat Exchanger Enabled Via Additive Manufacturing

Superheater tubes are critical boiler components that operate at relatively higher temperatures and pressure. Amongst the primary concerns for these tubes is the deposition of ash particles on the tube surface, leading to the reduced thickness of the tube due to material corrosion, consequently causing early creep failure of the component. In this research, a novel tube design has been proposed which resembles a teardrop or ogive shape to reduce the drag and concurrently improve the creep life of the superheater tubes. To administer the practicality of novel tubes, metal additive manufacturing (AM), for instance, laser-powder bed fusion (L-PBF), has been proposed. These unconventional designs were assessed and compared with the baseline circular tube design for mechanical design requirements (hoop stress and creep life) and the particle and flue gas flow characteristics around the differently shaped tubes. A thermomechanical finite element (FE) analysis was performed for hoop stress calculations. This study also emphasizes on effect of circumferential thermal variation on hoop stress distribution in tubes. Therefore, a detailed two-dimensional (2D) thermal simulation has been performed to report the circumferential thermal variation on the tube. A computational fluid dynamics (CFD) analysis coupled with particle tracing was performed for gas flow visualization and particle tracing around the proposed shapes and baseline circular-shaped tube design. The Schlieren optic setup was built and leveraged for qualitative validation of the proposed design. The complete design methodology established in the paper shows teardrop-shaped tubes better in terms of drag and creep life in contrast to the circular-shaped tube.

42 ENGINEERING↗

Simple processing via thermal treatment and catalyst infiltration to enhance nickel electrode performance for liquid alkaline water electrolyzers

Two simple processes for enhancing liquid alkaline water electrolyzer performance are demonstrated. Both enhance 3D Ni electrodes by introducing a micron-scale rough structure throughout the bulk of the electrode. Oxidation/reduction relies on a simple thermal treatment cycle to create surface roughening through the volumetric expansion during NiO formation and volume contraction during reduction back to Ni metal. Catalyst infiltration introduces a washcoat of additional metal particles throughout the electrode, by flooding the electrode with catalyst precursor and converting it to micron-scale particles via a reducing thermal treatment. Further, the largest improvement in performance (211mV at 1.8Acm -2 ) is observed for infiltrated NiFe-3x catalyst. For Fe-free Ni-only electrodes, oxidation/reduction provides a larger improvement (157 mV at 1.8Acm -2 ) than infiltrated Ni-3X (106mV at 1.8Acm -2 ). For both processes, the observed electrode surface structure and performance is quite sensitive to the thermal treatment temperature.

08 HYDROGEN↗

Impact of Different Thermal Gradients on the Dynamics of Cylindrical Lithium-ion Cells Subject to Accelerated Aging and on Module Performance

This study investigates the impacts of applying different thermal gradient patterns to cylindrical lithium-ion cells in a module on cell dynamics (temperatures, current flows, state of charge), module performance (evolution of resistance, capacity, and energy versus cycle number), and module lifetime. The thermal gradients were generated using cooling plates (CPs) with three different flow-field designs, namely, straight, perpendicular, and U-turn. The study uses computational fluid dynamics (CFD), the pseudo-two-dimensional (P2D) battery model, capacity loss and increased impedance due to the growth of a solid-electrolyte-interphase, and the electric current distribution from module terminals to cells that depends on the series-parallel electrical connections among the cells. The impact of the thermal gradient (resulting from the CP designs) on the variability in resistance, current, state of charge, and voltage among the cells was analyzed and linked to differences in the module's performance. Applying a thermal gradient to parallel-connected strings of series-connected cells led to variation in the current through each parallel string and an imbalance in the voltage of series-connected cells. Module performance is poorer when the thermal gradient causes a voltage imbalance than when it causes a current imbalance. Module performance becomes the worst when both current variation and voltage imbalance happen together. For instance, the module's lifetime (estimated as reaching 80% of its initial capacity) varied by 5% to 17.5%, depending on the magnitude and pattern of the imposed thermal gradient. As the relative orientation between thermal gradients and cells' electrical connectivity influences the module's performance, appropriate consideration should be given to the choice of the CP, especially if large thermal gradients are allowed.

Battery thermal management↗