Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal insulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Probe design and system integration

The feasibility of a common Saturn Uranus probe design is studied by considering the extreme atmospheres of both planets and their effects on a Pioneer spacecraft. It seems that approximately 85 percent of existing hardware can be used in an Uranus probe design, assuming that the design entry g level is somewhat reduced from current requirements. Additional development efforts include heat shielding, remotely activated batteries, mass spectrometer optimization, thermal insulation materials and high g packaging concepts.

Carroll, P.↗

Investigation of space shuttle vehicle 140C configuration orbiter (model 16-0) wheel well pressure loads in the Rockwell International 7.75 x 11 foot wind tunnel (OA143)

Experimental aerodynamic investigations were conducted on a sting mounted .0405-scale representation of the 140C outer mold line space shuttle orbiter configuration in the Rockwell International 7.75 x 11.00 foot low speed wind tunnel. The primary test objectives were to define the orbiter wheel well pressure loading and its effects on landing gear thermal insulation and to investigate the pressure environment experienced by both the horizontal flight nose probe and air vent door probes. Steady state and dynamic pressure values were recorded in the orbiter nose gear well, left main landing gear well, horizontal flight nose probe, and both left and right air vent door probe. All steady state pressure levels were measured by Statham differential pressure transducers while dynamic pressure levels were recorded by Kulite high frequency response pressure sensors.

Mennell, R. C.↗

Nonmetallic Materials Handbook

A handbook compilation of chemical and physical property tests data obtained during qualification and receiving inspection testing of nonmetallic materials for the Viking Lander is introduced. Data cover the following materials: sealants, potting compounds, lubricants, paints and finishes, inks, films, encapsulants, elastomers, structural plastics, ablatives, adhesives, and electrical and thermal insulation. Thermochemical data showing degradation as a function of temperature, from room to 500 C, are included.

Source record↗

Silicon germanium technology program at JPL

Review of the results of a program aimed at obtaining a better understanding of the long-term performance of a thermoelectric generator using silicon germanium. The results obtained concern the contact resistivity of the thermoelectric couples, the electrical resistance of the multifoil thermal insulation, and the application of resistance coatings to the unicouples in order to prevent the loss of output power due to internal shunting paths.

Stapfer, G.↗

Lunar mascons as consequences of giant impacts

An investigation is conducted regarding the effect of a giant impact on the thermal evolution of the moon. A model is proposed for the formation of the lunar mascons. The model takes into account the evidence of late volcanism during a period from about 3.7 to about 3.2 b.y. ago. It is found that a giant impact produces extensive fracturing in the region surrounding the basin and reduces the average thermal conductivity of the upper 20 km of this region by a factor of about 2. The less conductive ejecta blanket and the fractured zone behave as a thermal insulator. The lithosphere beneath the basin thickens monotonically and it becomes strong enough to support the mascon.

Arkani-Hamed, J.↗

Atmospheric cloud physics laboratory project study

Engineering studies were performed for the Zero-G Cloud Physics Experiment liquid cooling and air pressure control systems. A total of four concepts for the liquid cooling system was evaluated, two of which were found to closely approach the systems requirements. Thermal insulation requirements, system hardware, and control sensor locations were established. The reservoir sizes and initial temperatures were defined as well as system power requirements. In the study of the pressure control system, fluid analyses by the Atmospheric Cloud Physics Laboratory were performed to determine flow characteristics of various orifice sizes, vacuum pump adequacy, and control systems performance. System parameters predicted in these analyses as a function of time include the following for various orifice sizes: (1) chamber and vacuum pump mass flow rates, (2) the number of valve openings or closures, (3) the maximum cloud chamber pressure deviation from the allowable, and (4) cloud chamber and accumulator pressure.

Schultz, W. E.↗

Vibroacoustic testing of Space Shuttle thermal protection system panels

The modes and acoustic responses of two panels representing Space Shuttle thermal protection panels were investigated. The panels consisted of flat aluminum sheet stiffened longitudinally with hat-section stringers and corrugated supporting panels representing Shuttle ring frame bulkheads. In addition, one panel had 24 tiles of LI900 silica thermal insulation material and a strain isolator pad bonded to the face sheet. Both panels were found to have approximately eight modal frequencies in the 60 to 500 Hz range, where Shuttle acoustic loads are expected to be high. The strain response to a progressive acoustic wave representing a Shuttle spectrum was characterized by the occurrence of larger strains in the direction normal to the stringers than in the direction parallel to the stringers; three modes in the 100 to 400 Hz range contributed significantly to the strain response.

Rucker, C. E.↗

Stability of a viscous fluid in a rectangular cavity in the presence of a magnetic field

The stability of an electrically conducting fluid subjected to two dimensional disturbance was investigated. A physical system consisting of two parallel infinite vertical plates which are thermally insulated was studied. An external magnetic field of constant strength was applied to normal plates. The fluid was heated from below so that a steady temperature gradient was maintained in the fluid. The governing equations were derived by perturbation technique, and solutions were obtained by a modified Galerkin method. It was found that the presence of the magnetic field increases the stability of the physical system and instability can occur in the form of neutral or oscillatory instability.

Liang, C. Y.↗

Shuttle freezer conceptual design

A conceptual design for a kit freezer for operation onboard shuttle was developed. The freezer features a self-contained unit which can be mounted in the orbiter crew compartment and is capable of storing food at launch and returning with medical samples. Packaging schemes were investigated to provide the optimum storage capacity with a minimum weight and volume penalty. Several types of refrigeration systems were evaluated to select one which would offer the most efficient performance and lowest hazard of safety to the crew. Detailed performance data on the selected, Stirling cycle principled refrigeration unit were developed to validate the feasibility of its application to this freezer. Thermal analyses were performed to determine the adequacy of the thermal insulation to maintain the desired storage temperature with the design cooling capacity. Stress analyses were made to insure the design structure integrity could be maintained over the shuttle flight regime. A proposed prototype freezer development plan is presented.

Proctor, B. W.↗

Smoke generator

A smoke generator is disclosed which is particularly suitable for mounting on the wing tips of an aircraft and for conducting airflow studies. The device includes a network of thermally insulated tubes for carrying a fluid which is used to produce smoke. The fluid, which need not be combustible, is heated above its vaporization temperature by electric current which is passed through the fluid conduit tubes, so that the tubes serve both as fluid conduits and resistance heating elements. Fluid supply and monitoring systems and electrical control systems are also disclosed.

Rogers, J. R.↗

Flow separation detector

An arrangement for sensing the fluid separation along a surface which employs a thermally insulating element having a continuous surface blending into and forming a part of the fluid flow surface is described. A sudden decrease in the temperature of the downstream sensor conductor and concomitant increase in the temperature of the upstream sensor conductor is an indication of the separation. When the temperatures are returned to the state achieved during normal flow, the indicator thereby indicates the normal, attached fluid flow. The conductors may be, for example, wires or thin films, and should be within the viscous sub-layer of the expected fluid flow. A single heater and several pairs of sensors and corresponding sensor conductors may be used to detect not only the fluid flow and the separation, but the direction of the fluid flow, over the fluid flow surface.

Mateer, G. C.↗

Flow of viscous gas in the region of a slot with strong suction

The flow of a perfect viscous gas was studied in the region of a slot with strong suction. Velocity and temperature distribution fields are computed of the case of thermally insulated and heat conducting surfaces. The dependence of the flow characteristics on the suction gas discharge is obtained for a single slot with strong suction.

Kozlov, L. P.↗

Flexible heat-and-pressure seal

Device withstands both heat and pressure and accomodates relative motion between seated surfaces. Seal consists of flexible tube filled with thermally insulating material and coated with pressure resistant materials.

Bellavia, J., Jr.↗

Model fire tests on polyphosphazene rubber and polyvinyl chloride (PVC)/nitrile rubber foams

A video tape record of model room fire tests was shown, comparing polyphosphazene (P-N) rubber and polyvinyl chloride (PVC)/nitrile rubber closed-cell foams as interior finish thermal insulation under conditions directly translatable to an actual fire situation. Flashover did not occur with the P-N foam and only moderate amounts of low density smoke were formed, whereas with the PVC/nitrile foam, flashover occurred quickly and large volumes of high density smoke were emitted. The P-N foam was produced in a pilot plant under carefully controlled conditions. The PVC/nitrile foam was a commercial product. A major phase of the overall program involved fire tests on P-N open-cell foam cushioning.

Widenor, W. M.↗

Lithium cell tests at Langley Research Center

The long duration exposure facility mission places temperature requirements of from -30 F to +150 F on the batteries to be used. A hermetically sealed lithium sulfur dioxide cell was tested to predict what the temperature of the battery would be over a given spectrum of temperatures of operation. Near the end of cell discharge, as the voltage started collapsing, a very high heat output rise due to chemical reaction took place. However, if the cells were thermally insulated, they vented, ignited, and burned if an attempt was made to discharge them all the way. The cells do not go into reversal. It was determined that the root of the problem was probably the chemical reaction between the lithium and the acetonitrite solvent. A redesigned cell is discussed as well as some alternates.

Bene, J.↗

Test and evaluation of Fern Engineering Company, Incorporated, solar heating and hot water system

Tests, test results, examination and evaluation by Underwriters Laboratory, Inc., of a single family solar heating and hot water system consisting of collector, storage, control, transport, and data acquisition are presented. The structural characteristics of the solar flat plate collectors were evaluated according to snow and wind loads indicated in various building codes to determine their suitability for use both Michigan and Pennsylvania where prototype systems were installed. The flame spread classification of the thermal insulation is discussed and the fire tests conducted on components are described. The operation and dielectrics withstand tests of the energy transport module indicate the module is capable of rated air delivery. Tests of the control panel indicate the relay coil temperatures exceed the temperature limits allowed for the insulating materials involved.

Source record↗

Future planetary probes for Jupiter and Saturn

The paper describes a study conducted to identify the technology developments that would allow deep atmospheric investigations of Jupiter and Saturn to proceed beyond currently planned investigation of the upper atmosphere. The study considered a deep probe mission that would provide the capability to scientifically examine planetary atmospheres to the 1000-bar level and 1400-K level. The major conclusions of the study are that (1) a probe designed for Jupiter can be used with minor changes for Saturn, (2) new science instrument technology developments are required, and (3) the only new technology developments required in the engineering subsystem are high pressure thermal insulation materials and advanced data processing techniques.

Butts, A. J.↗