Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Test Fixture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Design and fabrication of graphite-epoxy bolted wing skin splice specimens

Graphite-epoxy bolted joint specimens were designed and fabricated. These specimens were to be representative of a side-of-body wing skin splice with a 20-year life expectancy in a commercial transport environment. Preliminary tests were performed to determine design values of bearing and net tension stresses. Based upon the information developed, a three-fastener-wide representative wing skin splice was designed for a load of 2627 KN/m (15,000 lbf/in.). One joint specimen was fabricated and tested at NASA. The wing skin splice failed at 106 percent of design ultimate load. This joint design achieved all static load objectives. Fabrication of six specimens, together with their loading fixtures, was completed, and the specimens were delivered to NASA-LRC.

Johnson, R. W.↗

Cryogenic Thermal Vacuum Testing with Remote Optical Metrology

Flexure Engineering was awarded an SBIR to research and develop technology needed to build a thermal vacuum chamber made to take laser radar metrology through a window. The XATF test is proof of concept for this, and demonstrated the need for such a chamber. XATF refers to two pieces of critical ground support equipment for NASA's JWST (James Webb Space Telescope) Integrated Science Instrument Module (ISIM), the ISIM Alignment Target Fixture (IATF) and the Master Alignment Target Fixture (MATF). These optical alignment assemblies require characterization while under cryogenic temperature. A thermal vacuum chamber equipped with a shroud cooled with gaseous and liquid nitrogen was used. An inner shroud was cooled with liquid helium to approximately 30K. The XATF assemblies were kinematically mounted and oriented inside the inner shroud such that the optical targets were visible from outside an optical window on one of the chamber ports. Laser radar and theodolite mounted outside the window took measurements of various optical targets. Two cold cycles were completed. A third cycle was aborted. Metrology was successfully taken. There were some problems with the helium system. The cryo pumps were turned off to reduce vibrations during metrology. Many new technologies and testing methods must be developed for JWST and future programs that will require precision measurements. These technologies will be applicable to other cold temperature applications, such as lunar missions and superconductors. Remote metrology technologies can also be applicable to testing in harsh environments. Facilities with remote metrology capability will be valuable.

Boyd, Guinevere↗

Resonant-fatigue cracking apparatus

Apparatus produces controlled surface cracks in test specimens. It has been developed and is useful in production of surface cracks of controlled size and shape in fracture specimens. It consists of specially-designed stand-mounted clamping fixture, commercially available pneumatic actuator, and suitable sound-control mufflers.

Dorner, J. P.↗

Interlaminar tension strength of graphite/epoxy composite laminates

An L-shaped curved beam specimen and a tension loading fixture were proposed to measure the interlaminar tension strength of laminated and textile composites. The specimen size was 2 X 2 in. (51 X 51 mm). The use of a standard tension test machine and the introduction of load nearly at the specimen midthickness were the advantages of the proposed specimen. Modified Lekhnitskii and beam theory equations for calculating interlaminar stresses of an L-beam were verified by finite element analysis. The beam theory equation is simple and accurate for mean radius to thickness ratios greater than 1.5. The modified Lekhnitskii equations can be used for detailed stress field calculation. AS4/3501-6 graphite/epoxy unidirectional specimens with thicknesses of 16, 24, and 32 piles were fabricated and tested. The delamination initiation site agreed with the calculated maximum interlaminar tension stress location for all three thicknesses. Average interlaminar tension strengths of 16-, 24-, and 32-ply laminates were 47.6, 40.9, and 23.4 MPa, respectively.

Shivakumar, Kunigal N.↗

Robotics in a controlled, ecological life support system

Controlled, Ecological Life Support Systems (CELSS) that utilize plants to provide food, water and oxygen could consume considerable amounts of labor unless crop production, recovery and processing are automated. Robotic manipulators equipped with special end-effectors and programmed to perform the sensing and materials handling tasks would minimize the amount of astronaut labor required. The Human Rated Test Facility (HRTF) planned for Johnson Space Center could discover and demonstrate techniques of crop production which can be reliably integrated with machinery to minimize labor requirements. Before the physical components (shelves, lighting fixtures, etc.) can be selected, a systems analysis must be performed to determine which alternative processes should be followed and how the materials handling tasks should be automated. Given that the current procedures used to grow crops in a CELSS may not be the best methods to automate, then what are the alternatives? How may plants be grown, harvested, processed for food, and the inedible components recycled? What commercial technologies current exist? What research efforts are underway to develop new technologies which might satisfy the need for automation in a CELSS? The answers to these questions should prove enlightening and provide some of the information necessary to perform the systems analysis. The planting, culturing, gathering, threshing and separation, food processing, and recovery of inedible portions of wheat were studied. The basic biological and materials handling processes of each task are defined and discussed. Current practices at Johnson Space Center and other NASA centers are described and compared to common production practices in the plant production industry. Technologies currently being researched which might be applicable are identified and illustrated. Finally, based on this knowledge, several scenarios are proposed for automating the tasks for wheat.

Miles, Gaines E.↗

The Effects of Compressive Preloads on the Compression-After-Impact Strength of Carbon/Epoxy

A fixture to apply compressive loads to composite specimens during an impact event was used to assess the effect of prestresses on the compression-after-impact (CAI) strength of 16 ply quasi-isotropic carbon/epoxy test coupons. Advanced design of experiments techniques were used to evaluate a range of prestresses and impact energies on two material systems, T300/934 and IM7/8551-7. An instrumented drop tower supplied impact energies between 1 and 9 Joules for the T300/934 material and between 4 and 16 Joules for the IM7/8551-7 material. The prestress values varied between a low of 5.7 Wa and a high of 287 NDa. Results showed some change in CAI strength that could be attributed to the prestresses on the specimens.

Nettles, Alan T.↗

Development of the structural technology of a large deployable antenna

The current NASA-sponsored Antenna Technology Development Program of the offset wrap-rib antenna concept is based on a ground test program of 'proof of concept' hardware whose potential on-orbit performance is based on analytical estimates. The ground demonstration hardware represents a partial 55-meter diameter reflector and feed support structure. Testing will include automated deployment, reflector surface quality evaluation and validation of analytical performance models. Test results and hardware fabrication costs will be used to refine the models that will be the basis for the preliminary design of a 100-meter diameter wrap-rib antenna system. Additionally, the design, processes, tooling, fabrication techniques, fixturing and assembly approaches used for the 'proof of concept' hardware are directly applicable to building flight systems up to 100 meters in diameter.

Wada, B. K.↗

Fabrication of strain-isolated ceramic coated combustor components

The use of strain-isolated ceramic coated material to produce an AGT1500 combustor scroll-shaped transition duct which requires no air for film cooling is investigated. The scroll receives the exhaust of the can-style combustor liner and turns it into the annular inlet of the high pressure gas producer turbine nozzle. Strain-isolation of plasma sprayed thermal barrier coating is achieved by placing a compliant pad between the structural base metal and the ceramic coating. The compliant pad is brazed to the metal structure. In order to achieve a good braze bond, the strain-isolating compliant pad and base metal must be closely matched in shape and tightly fixtured for joining. The complex geometry of the AGT1500 scroll makes it impractical to attack pads to the supporting structure in its finished shape. Instead the pads are brazed to flat stock and post-formed into scroll sections. While test samples were successfully post-formed, plasma sprayed, and subjected to cyclic heating, the forming of full scale parts by normal methods resulted in tearing of the Hastelloy-X base metal because of embrittlement by the braze material. Several solutions were explored which finally resulted in the successful forming of full scale scroll parts.

Rutter, S.↗

Spacecraft utensil/hand cleansing fixture

A fixture which provides a means for a crewman to perform, in zero gravity, laboratory utensil/tool cleansing and personal hygiene functions such as handwashing, shaving, body wash, and teeth brushing is described. A prototype unit developed incorporating design improvements resulting from breadboard tests in a one gravity and zero gravity environment demonstrated the capability of performing the different cleansing functions.

Jonkoniec, T. G.↗

EVA 2010: Preparing for International Space Station EVA Operations Post-Space Shuttle Retirement

The expected retirement of the NASA Space Transportation System (also known as the Space Shuttle ) by 2011 will pose a significant challenge to Extra-Vehicular Activities (EVA) on-board the International Space Station (ISS). The EVA hardware currently used to assemble and maintain the ISS was designed assuming that it would be returned to Earth on the Space Shuttle for refurbishment, or if necessary for failure investigation. With the retirement of the Space Shuttle, a new concept of operations was developed to enable EVA hardware (Extra-vehicular Mobility Unit (EMU), Airlock Systems, EVA tools, and associated support hardware and consumables) to perform ISS EVAs until 2015, and possibly beyond to 2020. Shortly after the decision to retire the Space Shuttle was announced, the EVA 2010 Project was jointly initiated by NASA and the OneEVA contractor team. The challenges addressed were to extend the operating life and certification of EVA hardware, to secure the capability to launch EVA hardware safely on alternate launch vehicles, to protect for EMU hardware operability on-orbit, and to determine the source of high water purity to support recharge of PLSSs (no longer available via Shuttle). EVA 2010 Project includes the following tasks: the development of a launch fixture that would allow the EMU Portable Life Support System (PLSS) to be launched on-board alternate vehicles; extension of the EMU hardware maintenance interval from 3 years (current certification) to a minimum of 6 years (to extend to 2015); testing of recycled ISS Water Processor Assembly (WPA) water for use in the EMU cooling system in lieu of water resupplied by International Partner (IP) vehicles; development of techniques to remove & replace critical components in the PLSS on-orbit (not routine); extension of on-orbit certification of EVA tools; and development of an EVA hardware logistical plan to support the ISS without the Space Shuttle. Assumptions for the EVA 2010 Project included no more than 8 EVAs per year for ISS EVA operations in the Post-Shuttle environment and limited availability of cargo upmass on IP launch vehicles. From 2010 forward, EVA operations on-board the ISS without the Space Shuttle will be a paradigm shift in safely operating EVA hardware on orbit and the EVA 2010 effort was initiated to accommodate this significant change in EVA evolutionary history.

Chullen, Cinda↗

Post-Shuttle EVA Operations on ISS

The expected retirement of the NASA Space Transportation System (also known as the Space Shuttle ) by 2011 will pose a significant challenge to Extra-Vehicular Activities (EVA) on-board the International Space Station (ISS). The EVA hardware currently used to assemble and maintain the ISS was designed assuming that it would be returned to Earth on the Space Shuttle for refurbishment, or if necessary for failure investigation. With the retirement of the Space Shuttle, a new concept of operations was developed to enable EVA hardware (Extra-vehicular Mobility Unit (EMU), Airlock Systems, EVA tools, and associated support hardware and consumables) to perform ISS EVAs until 2015, and possibly beyond to 2020. Shortly after the decision to retire the Space Shuttle was announced, the EVA 2010 Project was jointly initiated by NASA and the One EVA contractor team. The challenges addressed were to extend the operating life and certification of EVA hardware, to secure the capability to launch EVA hardware safely on alternate launch vehicles, to protect for EMU hardware operability on-orbit, and to determine the source of high water purity to support recharge of PLSSs (no longer available via Shuttle). EVA 2010 Project includes the following tasks: the development of a launch fixture that would allow the EMU Portable Life Support System (PLSS) to be launched on-board alternate vehicles; extension of the EMU hardware maintenance interval from 3 years (current certification) to a minimum of 6 years (to extend to 2015); testing of recycled ISS Water Processor Assembly (WPA) water for use in the EMU cooling system in lieu of water resupplied by International Partner (IP) vehicles; development of techniques to remove & replace critical components in the PLSS on-orbit (not routine); extension of on-orbit certification of EVA tools; and development of an EVA hardware logistical plan to support the ISS without the Space Shuttle. Assumptions for the EVA 2010 Project included no more than 8 EVAs per year for ISS EVA operations in the Post-Shuttle environment and limited availability of cargo upmass on IP launch vehicles. From 2010 forward, EVA operations on-board the ISS without the Space Shuttle will be a paradigm shift in safely operating EVA hardware on orbit and the EVA 2010 effort was initiated to accommodate this significant change in EVA evolutionary history. 1

West, William↗

Beam Stop For High-Power Lasers

Graphite/aluminum plate absorbs most of light. Beam stop fits on standard optical mounting fixture. Graphite plate thick enough to absorb incident laser beam but thin enough to transfer heat quickly to heat sink. Device used for variety of blocking purposes. For example, blocks laser beam after it passes through experimental setup, or at each stage of setup so stages checked and tested in sequence. Negligible reflectance of device is valuable safety feature, protecting both users and equipment from reflections.

Mcdermid, Iain S.↗

Inelastic response of metal matrix composites under biaxial loading

Theoretical predictions and experimental results were obtained for inelastic response of unidirectional and angle ply composite tubes subjected to axial and torsional loading. The composite material consist of silicon carbide fibers in a titanium alloy matrix. This material is known to be susceptible to fiber matrix interfacial damage. A method to distinguish between matrix yielding and fiber matrix interfacial damage is suggested. Biaxial tests were conducted on the two different layup configurations using an MTS Axial/Torsional load frame with a PC based data acquisition system. The experimentally determined elastic moduli of the SiC/Ti system are compared with those predicted by a micromechanics model. The test results indicate that fiber matrix interfacial damage occurs at relatively low load levels and is a local phenomenon. The micromechanics model used is the method of cells originally proposed by Aboudi. Finite element models using the ABACUS finite element program were used to study end effects and fixture specimen interactions. The results to date have shown good correlation between theory and experiment for response prior to damage initiation.

Lissenden, C. J.↗

Fiber reinforced PMR polyimide composites

Commercially obtained PMR-15 polyimide prepregs with S-glass and graphite fiber reinforcements were evaluated along with in-house prepared glass and graphite cloth PMR 2 materials. A novel autoclave approach was conceived and used to demonstrate that both the PMR systems respond to 1.4 MPa (200 psi) autoclave pressures to produce void free composites equivalent to die molded laminates. Isothermal gravimetric analysis and subsequent mechanical property tests indicated that the PMR 2 system was significantly superior in thermo-oxidative stability, and that S-glass reinforcements may contribute to the accelerated degradation of composites at 316 C (600 F) when compared to graphite fiber reinforced composites. Fully reversed bending fatigue experiments were conducted with a type of fixture unused for organic matrix composites. These studies indicated that the graphite fiber composites were clearly superior in fatigue resistance to the glass fiber reinforced material and that PMR matrix composite systems yield performance of the same order as composite materials employing other families of matrices.

Cavano, P. J.↗

Thermal/Mechanical Response and Damage Growth in Polymeric Composites at Cryogenic Temperatures

In order to increase the reliability of the next generation of space transportation systems, the mechanical behavior of polymeric matrix composite (PMC) materials at cryogenic temperatures must be investigated. This paper presents experimental data on the residual mechanical properties of a carbon fiber polymeric composite, IM7/PETI-5 both before and after aging at cryogenic temperatures. Tension modulus and strength were measured at room temperature, -196 C, and -269 C on five different specimen ply lay-ups, [0](sub 12), [90](sub 12), [+/-45](sub 3S), [+/-25](sub 3s) and [45,90(sub 3),-45,0(sub 3),-45,90(sub 3),45]. Specimens were preconditioned with one set of coupons being isothermally aged for 555 hours at -184 C in an unloaded state. Another set of corresponding coupons were mounted in constant displacement fixtures such that a constant uniaxial strain was applied to the specimens for 555 hours at -184 C. The measured lamina level properties indicated that cryogenic temperatures have an appreciable influence on behavior, and residual stress calculations based on lamination theory showed that the transverse tensile ply stresses could be quite high for cryogenic test temperatures. Microscopic examination of the surface morphology showed evidence of degradation along the exposed edges of the material due to aging at cryogenic temperatures.

Whitley, Karen S.↗

NASA Ames Research Center R and D Services Directorate Biomedical Systems Development

The Ames Research Center R&D Services Directorate teams with NASA, other government agencies and/or industry investigators for the development, design, fabrication, manufacturing and qualification testing of space-flight and ground-based experiment hardware for biomedical and general aerospace applications. In recent years, biomedical research hardware and software has been developed to support space-flight and ground-based experiment needs including the E 132 Biotelemetry system for the Research Animal Holding Facility (RAHF), E 100 Neurolab neuro-vestibular investigation systems, the Autogenic Feedback Systems, and the Standard Interface Glove Box (SIGB) experiment workstation module. Centrifuges, motion simulators, habitat design, environmental control systems, and other unique experiment modules and fixtures have also been developed. A discussion of engineered systems and capabilities will be provided to promote understanding of possibilities for future system designs in biomedical applications. In addition, an overview of existing engineered products will be shown. Examples of hardware and literature that demonstrate the organization's capabilities will be displayed. The Ames Research Center R&D Services Directorate is available to support the development of new hardware and software systems or adaptation of existing systems to meet the needs of academic, commercial/industrial, and government research requirements. The Ames R&D Services Directorate can provide specialized support for: System concept definition and feasibility Mathematical modeling and simulation of system performance Prototype hardware development Hardware and software design Data acquisition systems Graphical user interface development Motion control design Hardware fabrication and high-fidelity machining Composite materials development and application design Electronic/electrical system design and fabrication System performance verification testing and qualification.

Pollitt, J.↗

Truss structure tele-manipulation experiment using ETS-7

A robot experiment concept of space truss telemanipulation by National Aerospace Laboratory (NAL) is described in its flight model development. The experiment will be carried out on the Engineering Test Satellite No. 7 (ETS-7) using its robot arm. The satellite is scheduled to be launched in 1997 by National Space Development Agency of Japan (NASDA). The truss flight model is composed of deployable truss system and assemble truss joint. Those truss components will be manipulated by the ETS-7 robot arm using its small grapple fixture type-N (GPF-N), and the experimental task operation will be executed from the ground control station.

Matsumoto, Kohtaro↗

De-Trending Techniques: Methods for Cleaning Questionable Shock Data

Not all zero shifted acceleration data can De-trended using this technique. DC shifts, improper AC coupling, Circuit noise/EMI/EMR, Equivalent RC circuit gain response/Circuit saturation(Slew Rate Limited), fixture grounding and wiring losses can all contribute to bad shock data being recorded. Some data that is zero-shifted or exhibit large instantaneous velocity shifts is inherently bad and a retest is warranted. Clean Acceleration-Time history data can be bad upon examining the Velocity & Displacement profiles. Laser Vibrometers provide a high level of accuracy for pyrotechnic shock testing. Engineering judgment and experience will determine the validity of Shock data.

Grillo, Vincent J.↗