Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Test Fixture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Plant Atrium System for Food Production in NASA's Deep Space Habitat Tests

In preparation for future human exploration missions to space, NASA evaluates habitat concepts to assess integration issues, power requirements, crew operations, technology, and system performance. The concept of a Food Production System utilizes fresh foods, such as vegetables and small fruits, harvested on a continuous basis, to improve the crew's diet and quality of life. The system would need to fit conveniently into the habitat and not interfere with other components or operations. To test this concept, a plant growing "atrium" was designed to surround the lift between the lower and upper modules of the Deep Space Habitat and deployed at NASA Desert Research and Technology Studies (DRATS) test site in 2011 and at NASA Johnson Space Center in 2012. With this approach, no-utilized volume provided an area for vegetable growth. For the 2011 test, mizuna, lettuce, basil, radish and sweetpotato plants were grown in trays using commercially available red I blue LED light fixtures. Seedlings were transplanted into the atrium and cared for by the. crew. Plants were then harvested two weeks later following completion of the test. In 2012, mizuna, lettuce, and radish plants were grown similarly but under flat panel banks of white LEDs. In 2012, the crew went through plant harvesting, including sanitizing tlie leafy greens and radishes, which were then consumed. Each test demonstrated successful production of vegetables within a functional hab module. The round red I blue LEDs for the 2011 test lighting cast a purple light in the hab, and were less uniformly distributed over the plant trays. The white LED panels provided broad spectrum light with more uniform distribution. Post-test questionnaires showed that the crew enjoyed tending and consuming the plants and that the white LED light in 2012 provided welcome extra light for the main HAB AREA.

Massa, Gioia D.↗

Experimental investigation of strains in fabric under biaxial and shear forces.

The paper defines the experimental phase of an objective to obtain the mechanical characteristics and coefficients required by the generalized form of Hooke's law for nylon-polyurethane-coated fabric. Test specimens were cylindrical fabric sleeves and were loaded in axial tension by an Instron, in hoop tension by pressurizing, and in shear by a torquing fixture. An extensive amount of strain data is included for a wide combination of the three membrane loads. The tests indicate highly nonlinear stress-strain characteristics of the fabric and a strong dependency on all three membrane loads.

Alley, V. L., Jr.↗

High temperature tensile testing of ceramic composites

The various components of a high temperature tensile testing system are evaluated. The objective is the high temperature tensile testing of SiC fiber reinforced reaction bonded Si3N4 specimens at test temperatures up to 1650 C (3000 F). Testing is to be conducted in inert gases and air. Gripping fixtures, specimen configurations, furnaces, optical strain measuring systems, and temperature measurement techniques are reviewed. Advantages and disadvantages of the various techniques are also noted.

Gyekenyesi, John Z.↗

Predicted and measured strain responses of isotropic panels to base excitation

The accuracy of classical linear theory for predicting acceleration and strain for cantilevered and Clamped-Free-Clamped-Free (C-F-C-F) panels excited through the base is studied. Aluminum, steel and titanium plates of various dimensions and thicknessess were vibration tested, using a broadband random signal applied through a shaker mounting fixture. The strains were measured at 9 locations on the cantilevered panels and at 5 locations on the C-F-C-F panels. Predictions were based on the Ritz method. The measured accelerations of the base were input to the analysis for the forcing function. Comparisons between predicted and measured strain acceleration spectra were within an average error of 20 percent for both the cantilevered and C-F-C-F panels.

Lyle, Karen H.↗

Remote, Noncontact Strain Sensing by Laser Diffraction Developed

A system was developed at the NASA Glenn Research Center for continually monitoring, in real time, the in-plane strain tensor in opaque solids during high-temperature, long-term mechanical testing. The simple, noncontacting, strain-sensing methodology should also be suitable for measurement in hostile environments. This procedure has obvious advantages over traditional, mechanical, contacting techniques, and it is easier to interpret than moir and speckle interferometric approaches. A two-dimensional metallic grid of micrometer dimensions is applied to a metallographically prepared gauge section on the surface of a tensile test specimen by a standard photolithographic process. The grid on the fixtured specimen is interrogated by an He-Ne laser, and the resulting diffraction pattern is projected backwards onto a translucent screen. A charge-coupled device (CCD) camera is used to image the first-order diffraction peaks from the translucent screen. A schematic representation of the system is shown in the figure.

Freedman, Marc R.↗

Mixed-Mode Bending Method for Delamination Testing

A mixed mode delamination test procedure was developed combining double cantilever beam (DCB) mode I loading and end-notch fixture (ENF) mode II loading on a split unidirectional laminate. By loading with a lever, a single applied load simultaneously produces mode I and mode II bending loads on the specimen. This mixed-mode bending (MMB) test was analyzed using both finite-element procedures and beam theory to calculate the mode I and mode II components of strain-energy release rate G(sub I) and G(sub II), respectively. A wide range of G(sub I)/G(sub II) ratios can be produced by varying the load position on the lever. As the delamination extended, the G(sub I)/G(sub II) ratios varied by less than 5%. Beam theory equations agreed closely with the finite-element results and provide a basis for selection of G(sub I)/G(sub II) test ratios and a basis for computing the mode I and mode II components of measured delamination toughness. The MMB test was demonstrated using AS4/PEEK (APC2) unidirectional laminates. The MMB test introduced in this paper is rather simple and is believed to offer several advantages over most current mixed-mode test.

Reeder, James R.↗

Strapdown system performance optimization test evaluations (SPOT), volume 1

A three axis inertial system was packaged in an Apollo gimbal fixture for fine grain evaluation of strapdown system performance in dynamic environments. These evaluations have provided information to assess the effectiveness of real-time compensation techniques and to study system performance tradeoffs to factors such as quantization and iteration rate. The strapdown performance and tradeoff studies conducted include: (1) Compensation models and techniques for the inertial instrument first-order error terms were developed and compensation effectivity was demonstrated in four basic environments; single and multi-axis slew, and single and multi-axis oscillatory. (2) The theoretical coning bandwidth for the first-order quaternion algorithm expansion was verified. (3) Gyro loop quantization was identified to affect proportionally the system attitude uncertainty. (4) Land navigation evaluations identified the requirement for accurate initialization alignment in order to pursue fine grain navigation evaluations.

Blaha, R. J.↗

Strapdown system Performance Optimization Test evaluations (SPOT), volume 2

A three axis inertial system is packaged in an Apollo gimbal fixture for fine grain evaluation of strapdown system performance in dynamic environments. These evaluations have provided information to assess the effectiveness of real-time compensation techniques and to study system performance tradeoffs to factors such as quantization iteration rate. The strapdown performance and tradeoff studies conducted in this program are discussed.

Blaha, R. J.↗

Apparatus for Testing Flat Specimens of Thermal Insulation

An apparatus has been developed to implement an improved method of testing flat-plate specimens of thermal-insulation materials for cryogenic application. The method includes testing under realistic use conditions that could include vacuum and mechanical loading at a pressure up to 70 psi (=0.48 MPa). The apparatus can accommodate a rigid or flexible specimen having thickness up to 1.25 in. (=3.2 cm) and diameters between 6 and 10 in. (about 15.2 and 25.4 cm, respectively). Typical test conditions include boundary temperatures between 77 K and 373 K and vacuum/interstitial gas filling at a pressure between 10(exp -6) torr (=1.3 x 10(exp -4) Pa) and 760 torr (atmospheric pressure =0.1 MPa). The interstitial gas could be N2, He, CO2, or any other suitable gas to which the insulation is expected to be exposed in use. Relative to prior apparatuses and testing methods, this apparatus and the testing method that it implements offer advantages of relative simplicity and ease of use. The basic principle of operation of the apparatus is that of boil-off calorimetry, using liquid nitrogen or any other suitable liquid that boils at a desired temperature below ambient temperature. Comparative rates of flow of heat through the thicknesses of the specimens (heat-leak rates) and apparent-thermal-conductivity values are obtained from tests of specimens. Absolute values of heat-leak rates and apparent thermal conductivities are computed from a combination of (1) the aforementioned comparative values and (2) calibration factors obtained by testing reference specimens of materials that have known thermal-insulation properties. The apparatus includes a full complement of temperature sensors, a vacuum pump and chamber, a monitoring and control system, and tools and fixtures that enable rapid and reliable installation and removal of specimens. A specimen is installed at the bottom of the vacuum chamber, and a cold-mass assembly that includes a tank is lowered into position above and around the specimen (see figure). A spring-based compensating fixture helps to ensure adequate thermal contact with possibly irregular specimen surfaces. For a high-compression test, the springs can be replaced with spacers. A flat circular load cell at the bottom of the chamber measures the compressive load on the specimen. Once the desired compressive-load, temperature, and vacuum/gas-filling conditions are established, testing begins. During a test, all measurements are recorded by use of a portable data-acquisition system and a computer. The total heat-leak rate is measured and calculated as the boil-off flow rate multiplied by the latent heat of vaporization. The parasitic heat leak (to the side of the specimen and to the top and side of the cold-mass tank) is reduced to a small fraction of the total heat leak by use of a combination of multilayer-insulation (MLI) shield rings, reflective film, a fiberglass/epoxy centering ring, and a bulk fill of aerogel beads. This combination eliminates the need for a cryogenic guard chamber used in a typical prior apparatus to reduce the parasitic heat leak.

Fesmire, James E.↗

Measurement of the inertial properties of the Helios F-1 spacecraft

A gravity pendulum method of measuring lateral moments of inertia of large structures with an error of less than 1% is outlined. The method is based on the fact that in a physical pendulum with a knife-edge support the distance from the axis of rotation to the system center of gravity determines the minimal period of oscillation and is equal to the system centroidal radius of gyration. The method is applied to results of a test procedure in which the Helios F-1 spacecraft was placed in a roll fixture with crossed flexure pivots as elastic constraints and system oscillation measurements were made with each of a set of added moment-of-inertia increments. Equations of motion are derived with allowance for the effect of the finite pivot radius and an error analysis is carried out to find the criterion for maximum accuracy in determining the square of the centroidal radius of gyration. The test procedure allows all measurements to be made with the specimen in upright position.

Gayman, W. H.↗

Note on performance of tapered grip tensile loading devices

Alignment results are presented in terms of percent bending for a quick release, tapered grip, tensile loading device that has been proposed for testing sharply notched specimens of aluminum and magnesium alloys by a Task Group of the ASTM Committee E-24 on Fracture Testing of Metals. The results show that the bending introduced by the fixtures is strongly dependent on their relative rotational positions in respect to the loading rods which adapt them, to the tensile machine. For one set of tapered grips the highest bending was about 15%. Recommendations are made for improvement in the design of the tapered grips which should reduce the bending stresses substantially.

Jones, M. H.↗

Tension-mode loading for bend specimens in cryogens

Special fixture permits use of tension-loading apparatus in fracture-toughness tests on standard bend specimens. Specimen is held in place by spacer blocks and wire clips. Central, load-application roller bends specimen between lateral, reaction-load rollers.

Pierce, W. S.↗

Ultra-high temperature testing and performance of L-PBF C103

Additive Manufacturing (AM) of refractory alloys is gaining traction as a materials processing route for components subject to extreme temperature environments. Due to the low oxidation resistance of refractory alloys, novel methods for evaluating their elevated temperature performance must be developed. In this work, a Gleeble® 3800 thermomechanical load frame was modified to evaluate the mechanical properties of laser powder bed fusion (L-PBF) consolidated niobium alloy C103 ranging from room temperature (RT) to 1400 °C. The fixturing and sample geometry were designed to accommodate Joule heating and prevent damage to the test chamber. Oxidation of the samples was minimized via testing in vacuum level of 1E-5 Torr. Ultimate tensile strength (UTS), yield strength (YS), elongation, and strain-hardening behavior were determined as a function of temperature. L-PBF C103 presented an average UTS of ∼650 MPa and over 25 % elongation at RT. Above RT, the UTS and YS dropped then leveled off from 500 °C to 1000 °C with values ranging from ∼400 MPa to ∼460 MPa, which is consistent with dynamic strain aging observed in this class of alloys. The strength rapidly declined after 1200 °C to ∼150 MPa at 1400 °C. Fractography indicated ductile fractures for the C103 at all test temperatures, and Electron Backscatter Diffraction (EBSD) analysis revealed a textured microstructure and the presence of dynamic recrystallization within the necked region of the sample tested at 1400 °C.

33 ADVANCED PROPULSION SYSTEMS↗

Advanced manufacturing development of a composite empennage component for L-1011 aircraft

Work in process verification and tooling development continued. The decision was made to redesign the ribs to a more producible design. The bead was eliminated and the truss ribs changed to plain C sections. The solid web rib stiffeners were eliminated as well as the beads and the webs are now reinforced with a syntactic core. Syntectic is an epoxy containing glass microballoons. Two cover specimens were successfully tested. The first specimen (H27) was designed to verify the stability and compression strength of the cover when it is hot and wet. Failure occurred at 120 percent of design ultimate load. As the failure appeared to be fixture induced and was limited to one end of the panel, the remainder of the panel will be tested. The second specimen (H28) was designed to verify the failsafe aspects of the design. The test verified the design. Preparation of the PRVT test facility is nearing completion and all ten spar durability specimens were installed in the test chambers.

Source record↗

Inelastic response of metal matrix composites under biaxial loading

Elements of the analytical/experimental program to characterize the response of silicon carbide titanium (SCS-6/Ti-15-3) composite tubes under biaxial loading are outlined. The analytical program comprises prediction of initial yielding and subsequent inelastic response of unidirectional and angle-ply silicon carbide titanium tubes using a combined micromechanics approach and laminate analysis. The micromechanics approach is based on the method of cells model and has the capability of generating the effective thermomechanical response of metal matrix composites in the linear and inelastic region in the presence of temperature and time-dependent properties of the individual constituents and imperfect bonding on the initial yield surfaces and inelastic response of (0) and (+ or - 45)sub s SCS-6/Ti-15-3 laminates loaded by different combinations of stresses. The generated analytical predictions will be compared with the experimental results. The experimental program comprises generation of initial yield surfaces, subsequent stress-strain curves and determination of failure loads of the SCS-6/Ti-15-3 tubes under selected loading conditions. The results of the analytical investigation are employed to define the actual loading paths for the experimental program. A brief overview of the experimental methodology is given. This includes the test capabilities of the Composite Mechanics Laboratory at the University of Virginia, the SCS-6/Ti-15-3 composite tubes secured from McDonnell Douglas Corporation, a text fixture specifically developed for combined axial-torsional loading, and the MTS combined axial-torsion loader that will be employed in the actual testing.

Mirzadeh, F.↗

Laboratory simulation of cratering on small bodies

A new technique using external pressure was developed to simulate the lithostatic pressure due to self-gravity of small bodies. A 13-in. diameter cylindrical test chamber with L/D of 1 was fabricated to accommodate firing explosive charges with gas overpressures of up to 6000 psi. The chamber was hydrotested to 9000 psi. The method allows much larger scale factors that can be obtained with existing centrifuges and has the correct spherical geometry of self gravity. A simulant for jointed rock to be used in this fixture was developed using weakly cemented basalt. Various strength/pressure scaling theories can now be examined and tested.

Schmidt, Robert M.↗

Durability tester for FCC connectors

Testing device monitors continuity and resistance of each circuit, it includes springloaded stationary fixture which holds plug, and moving fixture which is driven by small electric motor and is geared to mate and unmate connector 10 times per minute.

Chambers, C. M.↗

Improved techniques of parallel gap welding and monitoring

Welding programs which show that parallel gas welding is a reliable process are discussed. When monitoring controls and nondestructive tests are incorporated into the process, parallel gap welding becomes more reliable and cost effective. The panel fabrication techniques and the HAC thermal cycling test indicate reliable product integrity. The design and building of automated tooling and fixturing for welding are discussed.

Mardesich, N.↗