Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Rapidly Changing Range Limits in a Warming World: Critical Data Limitations and Knowledge Gaps for Advancing Understanding of Mangrove Range Dynamics in the Southeastern USA

Climate change is altering species’ range limits and transforming ecosystems. For example, warming temperatures are leading to the range expansion of tropical, cold-sensitive species at the expense of their cold-tolerant counterparts. In some temperate and subtropical coastal wetlands, warming winters are enabling mangrove forest encroachment into salt marsh, which is a major regime shift that has significant ecological and societal ramifications. Here, we synthesized existing data and expert knowledge to assess the distribution of mangroves near rapidly changing range limits in the southeastern USA. We used expert elicitation to identify data limitations and highlight knowledge gaps for advancing understanding of past, current, and future range dynamics. Mangroves near poleward range limits are often shorter, wider, and more shrublike compared to their tropical counterparts that grow as tall forests in freeze-free, resource-rich environments. The northern range limits of mangroves in the southeastern USA are particularly dynamic and climate sensitive due to abundance of suitable coastal wetland habitat and the exposure of mangroves to winter temperature extremes that are much colder than comparable range limits on other continents. Thus, there is need for methodological refinements and improved spatiotemporal data regarding changes in mangrove structure and abundance near northern range limits in the southeastern USA. Advancing understanding of rapidly changing range limits is critical for foundation plant species such as mangroves, as it provides a basis for anticipating and preparing for the cascading effects of climate-induced species redistribution on ecosystems and the human communities that depend on their ecosystem services.

54 ENVIRONMENTAL SCIENCES↗

Numerical Study of Coupled Water and Vapor Flow, Heat Transfer, and Solute Transport in Variably-Saturated Deformable Soil During Freeze-Thaw Cycles

As climate change intensifies, soil water flow, heat transfer, and solute transport in the active, unfrozen zones within permafrost and seasonally frozen ground exhibit progressively more complex interactions that are difficult to elucidate with measurements alone. For example, frozen conditions impede water flow and solute transport in soil, while heat and mass transfer are significantly affected by high thermal inertia generated from water-ice phase change during the freeze-thaw cycle. To assist in understanding these subsurface processes, the current study presents a coupled two-dimensional model, which examines heat conduction-convection with water-ice phase change, soil water (liquid water and vapor) and groundwater flow, advective-dispersive solute transport with sorption, and soil deformation (frost heave and thaw settlement) in variably saturated soils subjected to freeze-thaw actions. This coupled multiphysics problem is numerically solved using the finite element method. The model's performance is first verified by comparison to a well-documented freezing test on unsaturated soil in a laboratory environment obtained from the literature. Then based on the proposed model, we quantify the impacts of freeze-thaw cycles on the distribution of temperature, water content, displacement history, and solute concentration in three distinct soil types, including sand, silt and clay textures. The influence of fluctuations in the air temperature, groundwater level, hydraulic conductivity, and solute transport parameters was also comparatively studied. The results show that (a) there is a significant bidirectional exchange between groundwater in the saturated zone and soil water in the vadose zone during freeze-thaw periods, and its magnitude increases with the combined influence of higher hydraulic conductivity and higher capillarity; (b) the rapid dewatering ahead of the freezing front causes local volume shrinkage within the non-frozen region when the freezing front propagates downward during the freezing stage and this volume shrinkage reduces the impact of frost heave due to ice formation. This gradually recovers when the thawed water replenishes the water loss zone during the thawing stage; and (c) the profiles of soil moisture, temperature, displacement, and solute concentration during freeze-thaw cycles are sensitive to the changes in amplitude and freeze-thaw period of the sinusoidal varying air temperature near the ground surface, hydraulic conductivity of soil texture, and the initial groundwater levels. Our modeling framework and simulation results highlight the need to account for coupled thermal-hydraulic-mechanical-chemical behaviors to better understand soil water and groundwater dynamics during freeze-thaw cycles and further help explain the observed changes in water cycles and landscape evolution in cold regions.

54 ENVIRONMENTAL SCIENCES↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sensitivity study of coupled chemical-CFD simulations for analyzing aluminum-clad spent nuclear fuel storage in sealed canisters

We report the United States Department of Energy (DOE) manages over 50 Metric Tons Heavy Metal (MTHM) of aluminum-clad spent nuclear fuel. One main source for DOE’s Aluminum-clad spent nuclear fuel (ASNF) inventory is the advanced test reactor (ATR) at the INL site, which makes this fuel of particular interest for storage scenarios. Road-ready and final disposition packaging configurations for the ATR fuel dictates storage within helium-backfilled, sealed DOE standard canisters. The conditions within these sealed canisters for extended (greater than50 year dry) storage is of interest. To further this goal, a three-dimensional (3D) multi-physics computational fluid dynamics (CFD) model is developed of the sealed DOE standard canisters. This 3D CFD model is one-way coupled with bulk gas radiolysis reactions considering sealed canisters with inert gas and possible trace amounts of air and water vapor. This study looks at the evolution of the thermal history of the canisters over a 50 year time period with a coupling to the chemical reactions occurring from radiolytic breakdown of residual water. A sensitivity study is then carried out over the parameters of the model including the fuel decay heat, residual water content, sealed pressure, canister external temperature, and canister emissivity. In pure helium, hydrogen generation rates are low, under 10 ppm, but hydrogen generation rates are affected greatly by the presence of even 1% residual air, increasing by 50-plus-fold, and nitric acid generation with residual air also occurs ranging from 500 to 4000 ppm after 50 years. The fuel decay heat and the residual water content show the most importance in the generation of hydrogen gas in pure air, and for nitric acid with a residual air condition. External temperature, canister emissivity and sealed pressure all show minor sensitivity effects to the generation of potentially harmful species.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Atomically dispersed Pb ionic sites in PbCdSe quantum dot gels enhance room-temperature NO2 sensing

Abstract Atmospheric NO 2 is of great concern due to its adverse effects on human health and the environment, motivating research on NO 2 detection and remediation. Existing low-cost room-temperature NO 2 sensors often suffer from low sensitivity at the ppb level or long recovery times, reflecting the trade-off between sensor response and recovery time. Here, we report an atomically dispersed metal ion strategy to address it. We discover that bimetallic PbCdSe quantum dot (QD) gels containing atomically dispersed Pb ionic sites achieve the optimal combination of strong sensor response and fast recovery, leading to a high-performance room-temperature p-type semiconductor NO 2 sensor as characterized by a combination of ultra–low limit of detection, high sensitivity and stability, fast response and recovery. With the help of theoretical calculations, we reveal the high performance of the PbCdSe QD gel arises from the unique tuning effects of Pb ionic sites on NO 2 binding at their neighboring Cd sites.

36 MATERIALS SCIENCE↗

An Energetic Diagnostic of Tropical Cyclone Size in f –Plane Simulations

As a major feature of tropical cyclones (TCs), controlling factors of TC outer size or size scaling remains a fundamental scientific question. The Rossby deformation radius and a natural extent associated with potential intensity have been proposed as two scalings of TC size. But neither of them satisfactorily captures the sensitivity of TC size to sea surface temperature (SST) in idealized f-plane simulations. Inspired by the studies of the Hadley circulation, here we proposed a new TC scaling based on an energetic diagnostic scaling. TC size is primarily a ratio of the secondary circulation strength to subsidence velocity, further determined by the total atmospheric heating in the ascending area, the gross moist stability, the diabatic cooling, and the dry static stability. The former two is based on the moist energetic budget applied to the whole storm structure, while the latter two is based on the dry thermodynamic budget applied to the subsidence areas. The new scaling well captured the sensitivity of TC size to SST in idealized f-plane simulations, partly resulted from expanded ascending area, increased surface moisture deficit, and weakened subsidence with increased SST.

58 GEOSCIENCES↗

Sea ice pattern effect on Earth’s energy budget is characterized by hemispheric asymmetry

Earth’s energy budget is sensitive to the spatial distribution of sea surface temperature and sea ice concentration (SIC) change, but the global radiative effect of changes in SIC spatial distribution has not been quantified. We show that SIC-induced radiation anomalies at the top of the atmosphere are sensitive to the location of SIC reduction in each season, which qualitatively explains how and why the effect of sea ice loss on Earth’s energy budget is determined by its spatial pattern. Idealized experiments indicate that SIC-induced surface warming is greater in the Arctic regions, resulting in a more negative Planck feedback. Global low-level cloud cover responses to Arctic and Antarctic SIC reduction are also distinct, leading to more negative SIC-cloud feedback in Arctic regions. SIC-induced albedo feedback is sensitive to latitude due to inhomogeneous solar radiation at the surface. As a result, the simulated radiative effect of SIC anomalies during 1980–2019 is dominated by variations in the spatial pattern of SIC.

54 ENVIRONMENTAL SCIENCES↗

Nitrogen thermometry in an inductively coupled plasma torch using broadband nanosecond coherent anti-Stokes Raman scattering

The development of atmospheric hypersonic flight and re-entry capabilities requires the characterization of the thermo-chemical state of representative test environments. This study demonstrates the usage of multiplex nanosecond N 2 coherent anti-Stokes Raman scattering (CARS) to measure temperatures in an atmospheric, high-temperature (>6000K), air plasma plume, generated by an inductively coupled plasma torch. These are some of the highest temperatures ever accessed via gas-phase CARS, to our knowledge. Temperatures of N 2 in the equilibrium plasma plume are determined via theoretical fits to measured CARS spectra. We discuss the practical implementation of CARS at very high temperatures, including the scaling of the N 2 CARS signal strength from 300 to 6700 K, where the expected peak signal from the high-temperature plasma torch gases is two orders of magnitude less than commonly encountered in combustion environments. An intensified CCD camera enables single-laser-shot detection at temperatures as high as 6200 K, by increasing sensitivity and providing a time gate against intense background luminosity. We also discuss the impacts of unwanted two-beam CARS contributions from outside the nominal three-beam measurement volume. We present mean axial and radial temperature profiles, as well as time-series data derived from both single-laser-shot and accumulated CARS spectra. The single-laser-shot precision is 1.7%–2.6% at temperatures of 3500 to 6200 K. The presented results pave the way for the use of CARS at very high temperatures and the measurement of spatially resolved interface processes in high-enthalpy flows.

Fries, Dan (ORCID:0000000229513294)↗

Detecting rare earth elements via optically detected magnetic resonance (ODMR) and spin-relaxometry using nitrogen vacancy centers in nanodiamonds

Nanodiamonds embedded with nitrogen-vacancy (NV) centers are emerging as powerful tools in quantum sensing due to their remarkable sensitivity to local variations in electromagnetic fields, temperature, and pressure. These point defects in the diamond lattice can be probed using optically detected magnetic resonance (ODMR) and spin relaxometry techniques, allowing for the detection and characterization of magnetic nanoparticles and ions. The sensing mechanism relies on laser-induced excitation of the NV center's non-degenerate triplet ground state, which promotes electrons to an excited state. Subsequent photoluminescence (PL) emission, which is spin-state dependent, is then measured. These spin states are highly responsive to magnetic perturbations in the surrounding environment. By analyzing changes in the ODMR spectra and spin relaxation times, we can effectively monitor how magnetic species influence the NV center's spin dynamics, thus enabling sensitive and selective characterization of nanoscale magnetic materials. These techniques have been applied for the characterization of transition metals and rare earth elements which shows natural ferromagnetic properties.

magnetic nanopartgicles and ions↗

Assessment of SCALE and MELCOR for a generic pebble bed fluoride high-temperature reactor

This paper presents the development and application of SCALE and MELCOR models for a fluoride salt-cooled high-temperature reactor (FHR) based on publicly available specifications. SCALE version 6.3beta15 was used to generate power distributions and decay heat curves, and MELCOR version 2.2.18019 was used to calculate the thermal hydraulic response of an assumed FHR primary system. Here, an approach was developed for determining the equilibrium state of the core using depletion of a core slice model and blending of fuel compositions at different burnups to provide three-dimensional fuel composition in the core. Results compared between a core with entirely fresh fuel and one with an equilibrium fuel composition revealed that the equilibrium core led to lower steady-state temperatures but slower cooldown during a loss of flow accident (LOFA). A sensitivity study was then conducted to explore the transient response of our FHR system to variations in thermal hydraulic parameters of the system using the equilibrium core. The inlet temperature, graphite thermal conductivity, and SCRAM time all provided significant control over peak fuel and coolant temperatures. Uncertainties in radionuclide decay data in SCALE were used to perform a decay heat sensitivity study, and we found that uncertainties in decay heat led to negligible impact on peak temperatures during the course of the transient. In all cases evaluated, the observed peak fuel temperatures remained approximately 700 K below anticipated failure limits for the LOFA.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluation of Stratocumulus Evolution Under Contrasting Temperature Advections in CESM2 Through a Lagrangian Framework

Abstract This study leveraged a Lagrangian framework to examine the evolution of stratocumulus clouds under cold and warm advections (CADV and WADV) in the Community Earth System Model 2 (CESM2) against observations. We found that CESM2 simulates a too rapid decline in low‐cloud fraction (LCF) and cloud liquid water path (CLWP) under CADV conditions, while it better aligns closely with observed LCF under WADV conditions but overestimates the increase in CLWP. Employing an explainable machine learning approach, we found that too rapid decreases in LCF and CLWP under CADV conditions are related to overestimated drying effects induced by sea surface temperature, whereas the substantial increase in CLWP under WADV conditions is associated with the overestimated moistening effects due to free‐tropospheric moisture and surface winds. Our findings suggest that overestimated drying effects of sea surface temperature on cloud properties might be one of crucial causes for the high equilibrium climate sensitivity in CESM2.

54 ENVIRONMENTAL SCIENCES↗

Insights into Constraining Rate Coefficients in Fuel Oxidation Mechanisms Using Genetic Algorithm Optimization

Accurate fuel oxidation mechanisms can enable predictive capabilities that aid in advancing combustion technologies. High-level computational kinetics can yield reasonable rate coefficients with uncertainties, in some cases, below a factor of 2. Computed rate coefficients can be constrained further by optimizing against experimental data. Here, we explore the application of genetic algorithm (GA) optimization to constrain computed rate coefficients in complex fuel oxidation mechanisms in conjunction with temperature-dependent species mole fractions from jet-stirred reactor (JSR) measurements. Cyclohexane is a model candidate for understanding the reactivity of cyclic fuels. In this work, we optimize the rate coefficients of the most recent literature cyclohexane mechanism, which incorporates theoretically computed rate coefficients for the reaction networks stemming from the first and second O 2 addition pathways, against the experimental results of two separate literature JSR studies. Optimization consistency is evaluated by carrying out three GA optimizations: fitting to the temperature-dependent species mole fractions in each JSR experiment separately and simultaneously fitting the species mole fractions in both experiments. Local sensitivity analyses are used to identify five influential low-temperature oxidation reactions for optimization. Although the three optimizations do not yield identical rate coefficients, the direction of change in all five rate coefficients is consistent among the three optimizations. Performance of the models from the three optimizations is assessed against literature ignition delay times with differences in the level of agreement observed among the different optimizations. In conclusion, comparisons are made with our recent optimization work of a cyclopentane oxidation master-equation model against time-resolved species concentrations, and insights and improvements of the strategy for constraining rate coefficients using GA optimization are discussed.

33 ADVANCED PROPULSION SYSTEMS↗

DeepPhenoMem V1.0: deep learning modelling of canopy greenness dynamics accounting for multi-variate meteorological memory effects on vegetation phenology

Abstract. Vegetation phenology plays a key role in controlling the seasonality of ecosystem processes that modulate carbon, water and energy fluxes between the biosphere and atmosphere. Accurate modelling of vegetation phenology in the interplay of Earth's surface and the atmosphere is thus crucial to understand how the coupled system will respond to and shape climatic changes. Phenology is controlled by meteorological conditions at different timescales: on the one hand, changes in key meteorological variables (temperature, water, radiation) can have immediate effects on the vegetation development; on the other hand, phenological changes can be driven by past environmental conditions, known as memory effects. However, the processes governing meteorological memory effects on phenology are not completely understood, resulting in their limited performance of vegetation phenology represented in land surface models. A deep learning model, specifically a long short-term memory network (LSTM), has the potential to capture and model the meteorological memory effects on vegetation phenology. Here, we apply the LSTM to model the vegetation phenology using meteorological drivers and high-temporal-resolution canopy greenness observations through digital repeat photography by the PhenoCam network. We compare a multiple linear regression model, a no-memory-effect LSTM model and a full-memory-effect LSTM model to predict the whole seasonal greenness trajectory and the corresponding phenological transition dates across 50 sites and 317 site years during 2009–2018, covering deciduous broadleaf forests, evergreen needleleaf forests and grasslands. Results show that the deep learning model outperforms the multiple linear regression model, and the full-memory-effect LSTM model performs better than the no-memory-effect model for all three plant function types (median R2 of 0.878, 0.957 and 0.955 for broadleaf forests, evergreen needleleaf forests and grasslands). We also find that the full-memory-effect LSTM model is capable of predicting the seasonal dynamic variations of canopy greenness and reproducing trends in shifting phenological transition dates. We also performed a sensitivity analysis of the full-memory-effect LSTM model to assess its plausibility, revealing its coherence with established knowledge of vegetation phenology sensitivity to meteorological conditions, particularly changes in temperature. Our study highlights that (1) multi-variate meteorological memory effects play a crucial role in vegetation phenology, and (2) deep learning opens up new avenues for improving the representation of vegetation phenological processes in land surface models via a hybrid modelling approach.

Geology↗

Ignition Delay Times and Chemical Kinetic Model Validation for Hydrogen and Ammonia Blending With Natural Gas at Gas Turbine Relevant Conditions

Ignition delay times from undiluted mixtures of natural gas (NG)/H 2 /Air and NG/NH 3 /Air were measured using a high-pressure shock tube at the University of Central Florida. The combustion temperatures were experimentally tested between 1000 and 1500 K near a constant pressure of 25 bar. As mentioned, mixtures were kept undiluted to replicate the same chemistry pathways seen in gas turbine combustion chambers. Recorded combustion pressures exceeded 200 bar due to the large energy release, hence why these were performed at the high-pressure shock tube facility. The data are compared to the predictions of the NUIGMech 1.1 mechanism for chemical kinetic model validation and refinement. An exceptional agreement was shown for stoichiometric conditions in all cases but strayed at lean and rich equivalence ratios, especially in the lower temperature regime of H 2 addition and all temperature ranges of the baseline NG mixture. Hydrogen addition also decreased ignition delay times by nearly 90%, while NH 3 fuel addition made no noticeable difference in ignition time. NG/NH 3 exhibited similar chemistry to pure NG under the same conditions, which is shown in a sensitivity analysis. Here, the reaction CH 3 + O 2 = CH 3 O + O is identified and suggested as a possible modification target to improve model performance. Increasing the robustness of chemical kinetic models via experimental validation will directly aid in designing next-generation combustion chambers for use in gas turbines, which in turn will greatly lower global emissions and reduce greenhouse effects.

33 ADVANCED PROPULSION SYSTEMS↗

Electrical conductivity of TaO x as function of composition and temperature

The ability to model the resistive switching devices depends on input material parameters and is particularly sensitive to values of electrical conductivity of the functional material as a function of composition and temperature. Here we report the results of conductivity measurements of TaO x with 0 AC ) changing from 0.34 eV at x=2.36 to 0.016 eV at x=1.

36 MATERIALS SCIENCE↗

Uses of Sensitivity/Uncertainty Techniques for Critical Experiment Design [Slides]

This presentation discusses the programming languages TSUNAMI and TSAR. It also provides a review of experimental designs using sensitivity analysis in regard to 7uPCX fuel design, fission product experiment analysis, MIRTE, and temperature dependent experiments at the Sandia Pulsed Reactor Facility (SPRF).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Signal Processing of Multiplexed Optical PWM Signals for Sensor Arrays in Nuclear Environments

Safe and effective generation of terrestrial nuclear power greatly benefits from the actionable data provided by the array of sensors located throughout a plant to provide a holistic online indication of reactor operation. This array includes sensors for monitoring coolant flow and pressure, temperature and heat transfer, radiation levels, structure health monitoring, and other critical parameters for reactor operation. While sensors capable of measuring these parameters have been developed, the electronics used in the pre-amplification and analog-to-digital conversion of the small signals they produce are extremely sensitive and susceptible to damage by high-temperatures and radiation environments nuclear reactors encounter while generating power. The small signals from sensors in nuclear power plants (NPPs) are transmitted over long cable runs which introduce dispersion artifacts into the signals of interest as well as electromagnetic interference (EMI) from lighting fixtures, pumps, mains electricity, and other equipment. To overcome these challenges, a front-end digitization (FREND) platform has been developed to use radiation-tolerant electronics to multiplex, amplify, and optically encode signals from an array of sensors for transmission over an optical fiber to mitigate dispersion and EMI artifacts from long runs of electrical cabling. To recover the optically transmitted data, a signal processing scheme based on 1-dimensional template matching to an indexing channel is described herein and demonstrated to have an effective bit-depth of 9.2 bits (1%). This scheme has been validated in proof-of-concept, non-nuclear testing and preliminary experimental results show good agreement between the measured optical output and and sensor input signals. The FREND system represents a low-loss data link between sensors in nuclear environments and data acquisition hardware which is aimed at improving the signal-to-noise ratio of the data acquired from these sensors to provide better information to operators and researchers.

Sweeney, Dan↗