Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME SIGNAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Antarctica Cloud Cover for October 2003 from GLAS Satellite Lidar Profiling

Seeing clouds in polar regions has been a problem for the imagers used on satellites. Both clouds and snow and ice are white, which makes clouds over snow hard to see. And for thermal infrared imaging both the surface and the clouds cold. The Geoscience Laser Altimeter System (GLAS) launched in 2003 gives an entirely new way to see clouds from space. Pulses of laser light scatter from clouds giving a signal that is separated in time from the signal from the surface. The scattering from clouds is thus a sensitive and direct measure of the presence and height of clouds. The GLAS instrument orbits over Antarctica 16 times a day. All of the cloud observations for October 2003 were summarized and compared to the results from the MODIS imager for the same month. There are two basic cloud types that are observed, low stratus with tops below 3 km and high cirrus form clouds with cloud top altitude and thickness tending at 12 km and 1.3 km respectively. The average cloud cover varies from over 93 % for ocean and coastal regions to an average of 40% over the East Antarctic plateau and 60-90% over West Antarctica. When the GLAS monthly average cloud fractions are compared to the MODIS cloud fraction data product, differences in the amount of cloud cover are as much as 40% over the continent. The results will be used to improve the way clouds are detected from the imager observations. These measurements give a much improved understanding of distribution of clouds over Antarctica and may show how they are changing as a result of global warming.

Spinhirne, J. D.↗

Digital CODEC for real-time processing of broadcast quality video signals at 1.8 bits/pixel

Advances in very large-scale integration and recent work in the field of bandwidth efficient digital modulation techniques have combined to make digital video processing technically feasible and potentially cost competitive for broadcast quality television transmission. A hardware implementation was developed for a DPCM-based digital television bandwidth compression algorithm which processes standard NTSC composite color television signals and produces broadcast quality video in real time at an average of 1.8 bits/pixel. The data compression algorithm and the hardware implementation of the CODEC are described, and performance results are provided.

Shalkhauser, Mary JO↗

Digital CODEC for real-time processing of broadcast quality video signals at 1.8 bits/pixel

Advances in very large scale integration and recent work in the field of bandwidth efficient digital modulation techniques have combined to make digital video processing technically feasible an potentially cost competitive for broadcast quality television transmission. A hardware implementation was developed for DPCM (differential pulse code midulation)-based digital television bandwidth compression algorithm which processes standard NTSC composite color television signals and produces broadcast quality video in real time at an average of 1.8 bits/pixel. The data compression algorithm and the hardware implementation of the codec are described, and performance results are provided.

Shalkhauser, Mary JO↗

Holistic digital gamma-ray spectroscopy methods and instrumentation for high-throughput high-resolution applications

Method of real-time adaptive digital pulse signal processing for high count rate gamma-ray spectroscopy applications includes receiving a preamplifier signal at a pulse deconvolver, the preamplifier signal including resolution deterioration resulting from pulse pile-up. The method further includes generating a deconvoluted signal, by the pulse deconvolver, from the preamplifier signal, the deconvoluted signal having less resolution deterioration as compared to the received preamplifier signal. The method furthermore includes shaping of the deconvoluted signal by a trapezoid filter, the shaping comprising adjusting a shaping parameter of the trapezoid filter for an incoming signal based on a time separation from a subsequent incoming signal.

Hawari, Ayman I.↗

Artificial intelligence-based predictive modeling for imaging neutral particle analyzers on the DIII-D tokamak

The Imaging Neutral Particle Analyzer (INPA) at DIII-D is a diagnostic system used to accurately resolve the energy and spatial distributions of fast ions in fusion plasmas. A novel artificial intelligence (AI) technique named INPA-net is based on Reservoir Computing Networks and developed here to predict active and passive signals produced by charge-exchange reactions from injected and edge-cold neutrals, respectively, in magnetically confined fusion plasmas. This model is trained using a set of 21 time domain signals between 0 s to 3.35 s that includes injected beam and thermal plasma information, and 6444 real 2D experimental images of the INPA in 12 plasma discharges at DIII-D. The trained neural network is able to forecast experimental images in real-time. The model achieves an R-squared value of 0.91, which is higher than the 0.83 value achieved by a simple linear regression model. This improvement highlights the model's enhanced predictive accuracy for measured images from the validation set. This AI approach is valuable due to its rapid response times and potential for integration into real-time plasma control systems. A version of this model capable of generating syntehic images would be useful for the real-time monitoring of fast-ion transport. A comprehensive sensitivity study reveals that INPA-net maintains high performance even with variations in the input parameters, indicating the model's robustness and reliability. While developed for the INPA, the underlying architecture is adaptable and may be applied to various 2D imaging diagnostics in fusion research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-space inversion and super-resolution of ultrafast scattering

Ultrafast scattering using x-rays or electrons is an emerging method to obtain structure dynamics at the atomic lengthscales and timescales. However, directly resolving in real-space atomic motions is inherently limited by the finite detector range and the probe energy. So, as a result, the time-resolved signal interpretation is mostly done in reciprocal space and relies on modeling and simulations of specific structures and processes. Here, we introduce a model-free approach to directly resolve scattering signals in real space, surpassing the diffraction limit, using scattering kernels and signal priors that naturally arise from the measurement constraints. We demonstrate the approach on simulated and experimental data, recover multiple atomic motions at sub-angstrom resolutions, and discuss the recovery accuracy and resolution limits versus signal fidelity. The approach offers a robust path to obtain high-resolution real-space information of atomic-scale structure dynamics using current time-resolved x-ray or electron scattering sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Salinity Remote Sensing and the Study of the Global Water Cycle

The SMOS and AquariusISAC-D satellite missions will begin a new era to map the global sea surface salinity (SSS) field and its variability from space within the next twothree years. They will provide critical data needed to study the interactions between the ocean circulation, global water cycle and climate. Key scientific issues to address are (1) mapping large expanses of the ocean where conventional SSS data do not yet exist, (2) understanding the seasonal and interannual SSS variations and the link to precipitation, evaporation and sea-ice patterns, (3) links between SSS and variations in the oceanic overturning circulation, (4) air-sea coupling processes in the tropics that influence El Nino, and (4) closing the marine freshwater budget. There is a growing body of oceanographic evidence in the form of salinity trends that portend significant changes in the hydrologic cycle. Over the past several decades, highlatitude oceans have become fresher while the subtropical oceans have become saltier. This change is slowly spreading into the subsurface ocean layers and may be affecting the strength of the ocean's therrnohaline overturning circulation. Salinity is directly linked to the ocean dynamics through the density distribution, and provides an important signature of the global water cycle. The distribution and variation of oceanic salinity is therefore attracting increasing scientific attention due to the relationship to the global water cycle and its influence on circulation, mixing, and climate processes. The oceans dominate the water cycle by providing 86% of global surface evaporation (E) and receiving 78% of global precipitation (P). Regional differences in E-P, land runoff, and the melting or freezing of ice affect the salinity of surface water. Direct observations of E-P over the ocean have large uncertainty, with discrepancies between the various state-of-the-art precipitation analyses of a factor of two or more in many regions. Quantifying the climatic influence of the oceanic water cycle requires more accurately resolving the net air-sea water flux. Measuring global SSS trends on seasonal to interannual timescales by satellite is fundamental to this problem because the SSS trends represent detectable time-integrated signals of the variable marine hydrological cycle. Satellite measurements, coupled with an array of in situ observations, will provide global synoptic SSS fields for the first time history. These data will provide a strong constraint on climate models and data assimilation efforts, which must properly represent the freshwater budget in terms of E-P, ocean advection and surface layer mixing in order to accurately simulate the true ocean state. The SSS fields will allow us to quantify the covariability between the SSS and the strong seasonal E-P cycle in the tropics and high latitudes. Field measurement campaigns to exploit satellite and in situ measurements to close the seasonal E-P cycle over an ocean region are being considered. Lastly the satellite systems will monitor and trace the large long-lived SSS anomalies from year to year that have the potential to influence El Nino and the large scale ocean circulation.

Lagerloef, G. S. E.↗

Multichannel Doppler transmission grating spectrometer at the Alcator C-Mod tokamak

Upgrades to an existing transmission grating spectrometer for visible light used for Doppler velocity and temperature measurements at the Alcator C-Mod tokamak are given. These include a new Princeton Instruments Photonmax 512B charge-coupled device and a four channel fiber optic input. These together allow improvements to the signal level, time resolution, and the number of spatial channels. The fiber optic input allows four simultaneous spatial channels each of which offers a larger percentage of input light flux when compared to the standard fiber slit combination. The ''on chip'' amplification combined with versatile pixel binning further increases the signal to noise ratio allowing a continuous acquisition of spectra every 8 ms. The error bars for extracted velocity and temperature values are potentially smaller owing to the smaller pixel size and increased light flux which allow a more detailed line shape and simplifies line fitting. Examples of time and space resolved spectra are shown and further improvements are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision and Accuracy in PDV and VISAR

This is a technical report discussing our current level of understanding of a wide and varying distribution of uncertainties in velocity results from Photonic Doppler Velocimetry in its application to gas gun experiments. Using propagation of errors methods with statistical averaging of photon number fluctuation in the detected photocurrent and subsequent addition of electronic recording noise, we learn that the velocity uncertainty in VISAR can be written in closed form. For PDV, the non-linear frequency transform and peak fitting methods employed make propagation of errors estimates notoriously more difficult to write down in closed form expect in the limit of constant velocity and low time resolution (large analysis-window width). An alternative method of error propagation in PDV is to use Monte Carlo methods with a simulation of the time domain signal based on results from the spectral domain. A key problem for Monte Carlo estimation for an experiment is a correct estimate of that portion of the time-domain noise associated with the peak-fitting region-of-interesting in the spectral domain. Using short-time Fourier transformation spectral analysis and working with the phase dependent real and imaginary parts allows removal of amplitude-noise cross terms that invariably show up when working with correlation-based methods or FFT power spectra. Estimation of the noise associated with a given spectral region of interest is then possible. At this level of progress, we learn that Monte Carlo trials with random recording noise and initial (uncontrolled) phase yields velocity uncertainties that are not as large as those observed. In a search for additional noise sources, a speckleinterference modulation contribution with off axis rays was investigated, and was found to add a velocity variation beyond that from the recording noise (due to random interference between off axis rays), but in our experiments the speckle modulation precision was not as important as the recording noise precision. But from these investigations we do appreciate that the velocity-uncertainty itself has a wide distribution of values that varies with signal-amplitude modulation (is not a single value). To provide a rough rule of thumb for the velocity uncertainty, we computed the average of the relative standard deviation distributions from 60 recorded traces (with distributions of uncertainties roughly between 0.1 % to 1 % in each trace) and found a mean of the distribution of uncertainties for our experiments is not better than 0.4 % at an analysis window width of 5 ns (although for brief intervals it can be as good as 0.1 %). Further imagination and testing may be needed to reveal other possible hydrodynamics-related sources of velocity error in PDV.

47 OTHER INSTRUMENTATION↗

Signal processing to reduce dark noise impact in precision timing

We introduce a technique to mitigate the effects of low frequency noise on precision timing. The example of Dark Count Noise Rate (DCR) in Silicon Photomultipliers (SiPMs) is emphasized. This technique exploits the correlation between time shifts on the leading edge of a signal and the residual slope of the baseline (due to noise) which remains after baseline subtraction. In fast timing applications (such as for Time-of-flight particle ID) the signal arrival time is typically captured on the signal leading edge. The signal risetime is often fixed by the physics of the sensor and input circuit. Then accurate pulse timing can be achieved by correcting a leading edge threshold time (depending on a slope proportional to both the Amplitude and the risetime) to a “constant fraction” time. This compensation for time walk due to amplitude fluctuations breaks down once we introduce interference from low frequency noise on the leading edge. In this paper we demonstrate that an additional measurement of the slope at threshold can be used to correct for this noise jitter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Biosensor method and system based on feature vector extraction

A method of biosensor-based detection of toxins comprises the steps of providing at least one time-dependent control signal generated by a biosensor in a gas or liquid medium, and obtaining a time-dependent biosensor signal from the biosensor in the gas or liquid medium to be monitored or analyzed for the presence of one or more toxins selected from chemical, biological or radiological agents. The time-dependent biosensor signal is processed to obtain a plurality of feature vectors using at least one of amplitude statistics and a time-frequency analysis. At least one parameter relating to toxicity of the gas or liquid medium is then determined from the feature vectors based on reference to the control signal.

59 BASIC BIOLOGICAL SCIENCES↗

Biosensor method and system based on feature vector extraction

A system for biosensor-based detection of toxins includes providing at least one time-dependent control signal generated by a biosensor in a gas or liquid medium, and obtaining a time-dependent biosensor signal from the biosensor in the gas or liquid medium to be monitored or analyzed for the presence of one or more toxins selected from chemical, biological or radiological agents. The time-dependent biosensor signal is processed to obtain a plurality of feature vectors using at least one of amplitude statistics and a time-frequency analysis. At least one parameter relating to toxicity of the gas or liquid medium is then determined from the feature vectors based on reference to the control signal.

47 OTHER INSTRUMENTATION↗

Claudin-1 promotes TNF-α-induced epithelial-mesenchymal transition and migration in colorectal adenocarcinoma cells

Epithelial-mesenchymal transition (EMT) is an important mechanism in cancer progression and malignancy including colorectal cancer (CRC). Importantly, inflammatory mediators are critical constituents of the local tumor environment and an intimate link between CRC progression and inflammation is now validated. We and others have reported key role of the deregulated claudin-1 expression in colon carcinogenesis including colitis-associated colon cancer (CAC). However, the causal association between claudin-1 expression and inflammation-induced colon cancer progression remains unclear. Here we demonstrate, TNF-α, a pro-inflammatory cytokine, regulates claudin-1 to modulate epithelial to mesenchymal transition (EMT) and migration in colon adenocarcinoma cells. Importantly, colon cancer cells cultured in the presence of TNF-α (10 ng/ml), demonstrated a sharp decrease in E-cadherin expression and an increase in vimentin expression (versus control cells). Interestingly, TNF-α treatment also upregulated (and delocalized) claudin-1 expression in a time-dependent manner accompanied by increase in proliferation and wound healing. Furthermore, similar to our previous observation that claudin-1 overexpression in CRC cells induces ERK1/2 and Src- activation, signaling associated with colon cancer cell survival and transformation, TNF-α-treatment induced upregulation of phospho-ERK1/2 and -Src expression. The shRNA-mediated inhibition of claudin-1 expression largely abrogated the TNF-α-induced changes in EMT, proliferation, migration, p-Erk and p-Src expression. Taken together, our data demonstrate TNF-α mediated regulation of claudin-1 and tumorigenic abilities of colon cancer cells and highlights a key role of deregulated claudin-1 expression in inflammation-induced colorectal cancer growth and progression, through the regulation of the ERK and Src-signaling.

60 APPLIED LIFE SCIENCES↗

Optimal control of the signal-to-noise ratio per unit time of a spin 1/2 particle: The crusher gradient and the radiation damping cases

We show to which extent the signal to noise ratio per unit time of a spin 1/2 particle can be maximized. We consider a cyclic repetition of experiments made of a measurement followed by a radio-frequency magnetic field excitation of the system, in the case of unbounded amplitude. In the periodic regime, the objective of the control problem is to design the initial state of the system and the pulse sequence which leads to the best signal to noise performance. We focus on two specific issues relevant in nuclear magnetic resonance, the crusher gradient and the radiation damping cases. Optimal control techniques are used to solve this non-standard control problem. We discuss the optimality of the Ernst angle solution, which is commonly applied in spectroscopic and medical imaging applications. In the radiation damping situation, we show that in some cases, the optimal solution differs from the Ernst one.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A new probe of μ Hz gravitational waves with FRB timing

We propose Fast Radio Burst (FRB) timing, which uses the precision measurements of the arrival time differences of repeated FRB signals along multiple sightlines, as a new probe of gravitational waves (GWs) around nHz to μHz frequencies, with the highest frequency limited by FRB repeating period. The anticipated experiment requires a sightline separation of tens of AU, achieved by sending radio telescopes to space. We find the signal of arrival time difference induced by GWs depends only on the local GWs in the solar system and we can correlate the measurements from different FRB sources or the same source with different repeaters, which leads to a better sensitivity with a larger number of FRB repeaters detected. Here, the projected sensitivity shows this method is a competitive probe in the nHz to μ Hz frequency range. It can fill the 'μHz gap' between pulsar timing arrays and Laser Interferometer Space Antenna (LISA) and is complementary to other proposals of GW detection in this frequency band.

79 ASTRONOMY AND ASTROPHYSICS↗