Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Continuous measurement of boron concentration in nuclear power plants: why is it essential for safe and efficient operation? - 318

As a neutron-absorber, Boron 10 plays a significant role in nuclear power plants as it is used in order to control reactivity in the core, together with control rods. For that reason; it is a key parameter that has to be controlled. In a similar way, it is crucial to be able to detect a boron dilution in the primary circuit, as it would causes severe damages if not detected and controlled. Thus, it comes as evidence that a boron concentration monitoring system is a key for every nuclear power plant. Consequently, it becomes important to provide plant operators with a boron concentration measurement issued by a reliable, redundant, classified and qualified system, with high accuracy and short response time. In order to cover this need, Rolls-Royce has designed Boronline{sup R}, the latest generation of boron meter, which provides nuclear power plant operators with a permanent record of boron concentration of primary circuit by way of continuous sampling and real-time measurements. Boronline takes part of a new generation of Advanced Sensors and Measurements Technologies. In this paper, boron meter role, main functions and measuring principles will be detailed, as well as technical characteristics of the new generation of boron meter will be presented. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dissecting the Gravitational Lens B1608 656. II. Precision Measurements of the Hubble Constant, Spatial Curvature, and the Dark Energy Equation of State

Strong gravitational lens systems with measured time delays between the multiple images provide a method for measuring the 'time-delay distance' to the lens, and thus the Hubble constant. We present a Bayesian analysis of the strong gravitational lens system B1608+656, incorporating (1) new, deep Hubble Space Telescope (HST) observations, (2) a new velocity dispersion measurement of 260 {+-} 15 km s{sup -1} for the primary lens galaxy, and (3) an updated study of the lens environment. Our analysis of the HST images takes into account the extended source surface brightness, and the dust extinction and optical emission by the interacting lens galaxies. When modeling the stellar dynamics of the primary lens galaxy, the lensing effect, and the environment of the lens, we explicitly include the total mass distribution profile logarithmic slope {gamma}{prime} and the external convergence {kappa}{sub ext}; we marginalize over these parameters, assigning well-motivated priors for them, and so turn the major systematic errors into statistical ones. The HST images provide one such prior, constraining the lens mass density profile logarithmic slope to be {gamma}{prime} = 2.08 {+-} 0.03; a combination of numerical simulations and photometric observations of the B1608+656 field provides an estimate of the prior for {kappa}{sub ext}: 0.10{sub -0.05}{sup +0.08}. This latter distribution dominates the final uncertainty on H{sub 0}. Fixing the cosmological parameters at {Omega}{sub m} = 0.3, {Omega}{sub {Lambda}} = 0.7, and w = -1 in order to compare with previous work on this system, we find H{sub 0} = 70.6{sub -3.1}{sup +3.1} km s{sup -1} Mpc{sup -1}. The new data provide an increase in precision of more than a factor of two, even including the marginalization over {kappa}{sub ext}. Relaxing the prior probability density function for the cosmological parameters to that derived from the WMAP 5-year data set, we find that the B1608+656 data set breaks the degeneracy between {Omega}{sub m} and {Omega}{sub {Lambda}} at w = -1 and constrains the curvature parameter to be -0.031 < {Omega}{sub k} < 0.009 (95% CL), a level of precision comparable to that afforded by the current Type Ia SNe sample. Asserting a flat spatial geometry, we find that, in combination with WMAP, H{sub 0} = 69.7{sub 5.0}{sup +4.9} km s{sup -1} Mpc{sup -1} and w = -0.94{sub -0.19}{sup +0.17} (68% CL), suggesting that the observations of B1608+656 constrain w as tightly as do the current Baryon Acoustic Oscillation data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gamma-ray timing of redback PSR J2339–0533: Hints for gravitational quadrupole moment changes

We present the results of precision gamma-ray timing measurements of the binary millisecond pulsar PSR J2339–0533, an irradiating system of the “redback” type, using data from the Fermi Large Area Telescope. We describe an optimized analysis method to determine a long-term phase-coherent timing solution spanning more than six years, including a measured eccentricity of the binary orbit and constraints on the proper motion of the system. A major result of this timing analysis is the discovery of an extreme variation of the nominal 4.6 hr orbital period P{sub orb} over time, showing alternating epochs of decrease and increase. We inferred a cyclic modulation of P{sub orb} with an approximate cycle duration of 4.2 yr and a modulation amplitude of ΔP{sub orb}/P{sub orb}=2.3×10{sup −7}. Considering different possible physical causes, the observed orbital-period modulation most likely results from a variable gravitational quadrupole moment of the companion star due to cyclic magnetic activity in its convective zone.

79 ASTRONOMY AND ASTROPHYSICS↗

DISSECTING THE GRAVITATIONAL LENS B1608+656. II. PRECISION MEASUREMENTS OF THE HUBBLE CONSTANT, SPATIAL CURVATURE, AND THE DARK ENERGY EQUATION OF STATE

Strong gravitational lens systems with measured time delays between the multiple images provide a method for measuring the 'time-delay distance' to the lens, and thus the Hubble constant. We present a Bayesian analysis of the strong gravitational lens system B1608+656, incorporating (1) new, deep Hubble Space Telescope (HST) observations, (2) a new velocity-dispersion measurement of 260 +- 15 km s{sup -1} for the primary lens galaxy, and (3) an updated study of the lens' environment. Our analysis of the HST images takes into account the extended source surface brightness, and the dust extinction and optical emission by the interacting lens galaxies. When modeling the stellar dynamics of the primary lens galaxy, the lensing effect, and the environment of the lens, we explicitly include the total mass distribution profile logarithmic slope gamma' and the external convergence kappa{sub ext}; we marginalize over these parameters, assigning well-motivated priors for them, and so turn the major systematic errors into statistical ones. The HST images provide one such prior, constraining the lens mass density profile logarithmic slope to be gamma' = 2.08 +- 0.03; a combination of numerical simulations and photometric observations of the B1608+656 field provides an estimate of the prior for kappa{sub ext}: 0.10{sup +0.08}{sub -0.05}. This latter distribution dominates the final uncertainty on H{sub 0}. Fixing the cosmological parameters at OMEGA{sub m} = 0.3, OMEGA{sub L}AMBDA = 0.7, and w = -1 in order to compare with previous work on this system, we find H{sub 0} = 70.6{sup +3.1}{sub -3.1} km s{sup -1} Mpc{sup -1}. The new data provide an increase in precision of more than a factor of 2, even including the marginalization over kappa{sub ext}. Relaxing the prior probability density function for the cosmological parameters to that derived from the Wilkinson Microwave Anisotropy Probe (WMAP) five-year data set, we find that the B1608+656 data set breaks the degeneracy between OMEGA{sub m} and OMEGA{sub L}AMBDA at w = -1 and constrains the curvature parameter to be -0.031 < OMEGA{sub k} < 0.009 (95% CL), a level of precision comparable to that afforded by the current Type Ia SNe sample. Asserting a flat spatial geometry, we find that, in combination with WMAP, H{sub 0} = 69.7{sup +4.9}{sub -5.0} km s{sup -1} Mpc{sup -1} and w = -0.94{sup +0.17}{sub -0.19} (68% CL), suggesting that the observations of B1608+656 constrain w as tightly as the current Baryon Acoustic Oscillation data do.

79 ASTRONOMY AND ASTROPHYSICS↗

A new calibration method for time delay standard and its application

A method which is used to measure time delay accurately by using a Type 900-LB slotted line is described. The accuracy for calibrating time delay of a precision coaxial air line Type 900-L is about + or - (0.4 to 0.6)ps, and for coaxial cables with VSWR less than 1.5 and time delay t less than 50ns is about + or - (3 to 5)ps. Theoretical analysis and mathematical derivation of microwave networks in cascade are given. Methods to eliminate the errors which are caused by the discontinuities and the error analysis of the measuring system are presented. Skin effect analysis of the transient characteristic of coaxial transmission line are discussed in detail. Methods to eliminate the errors which result from using the calibrated time delay standard to calibrate time interval measurement instruments are presented. The estimation of errors and formulae for correction of those errors are described.

Su, B. W.↗

Reaction hysteresis of the CO+O{yields}CO{sub 2} reaction on palladium(111)

Rate measurements of the reaction CO+O{yields}CO{sub 2} on palladium(111) single crystal surfaces have been performed by means of mass spectroscopy under ultrahigh vacuum conditions. The total flux {phi} of the impinging reactants CO and O{sub 2} was held constant at 1 ML s{sup -1}, whereas its CO fraction Y was varied between 0 (pure O{sub 2}) and 1 (pure CO). The measurements have been performed for surface temperatures between 370 and 510 K and with a wide range of sampling times, evaluating the system parameter range for bistable behavior. Long-time measurements lasting several days proved the bistable behavior to result from two stable states rather than from slow processes not visible on usual experimental time scales. Pulselike modulations of the feed gas composition revealed the mechanisms confining the experimentally observed bistable range: the high CO fraction border of the bistability is given by the equistability condition of both states, whereas the other border is found to be associated with a saddle-node bifurcation in the corresponding system of reaction diffusion equations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The luminescence characteristics of CsI(Na) crystal under {alpha} and X/{gamma} excitation

In this paper, we study the effective decay time characteristic of CsI(Na) crystal under {sup 239}Pu alpha particle and {sup 137}Cs gamma-ray excitation using a single photon counting decay time measurement system. The measurement system employs a silicon optical fiber to couple and transit single photon. The slow decay time component of CsI(Na) crystal is 460-550 ns. We observe a 15 ns fast decay component under alpha particle excitation. In addition, we find that the primary stage of the falling edge in the decay time curve is non-exponential and drops rapidly when CsI(Na) crystal is excited by {sup 239}Pu alpha particles. Since the high density of self-trapped-excitons (STEs) is produced in alpha particle excitation process, we propose that the fast falling edge is corresponding to the quenching process of STEs which transit with non-radiation in the case of high excitation density. To prove this proposal, we excited the CsI(Na) crystal with sub-nanosecond intensive pulsed X-ray radiation. Our X-ray impinging results show that the fast falling edge also exists under low energy (average 100 keV) bremsstrahlung X-ray excitation.

36 MATERIALS SCIENCE↗

In-Line Capacitance Sensor for Real-Time Water Absorption Measurements

A capacitance/dielectric sensor was designed, constructed, and used to measure in real time the in-situ water concentration in a desiccant water bed. Measurements were carried out with two experimental setups: (1) passing nitrogen through a humidity generator and allowing the gas stream to become saturated at a measured temperature and pressure, and (2) injecting water via a syringe pump into a nitrogen stream. Both water vapor generating devices were attached to a downstream vertically-mounted water capture bed filled with 19.5 g of Moisture Gone desiccant. The sensor consisted of two electrodes: (1) a 1/8" dia stainless steel rod placed in the middle of the bed and (2) the outer shell of the stainless steel bed concentric with the rod. All phases of the water capture process (background, heating, absorption, desorption, and cooling) were monitored with capacitance. The measured capacitance was found to vary linearly with the water content in the bed at frequencies above 100 kHz indicating dipolar motion dominated the signal; below this frequency, ionic motion caused nonlinearities in the water concentration/capacitance relationship. The desiccant exhibited a dielectric relaxation whose activation energy was lowered upon addition of water indicating either a less hindered rotational motion or crystal reorientation.

Nurge, Mark A.↗

Time-Resolved Rayleigh Scattering Measurements in Hot Gas Flows

A molecular Rayleigh scattering technique is developed to measure time-resolved gas velocity, temperature, and density in unseeded gas flows at sampling rates up to 32 kHz. A high power continuous-wave laser beam is focused at a point in an air flow field and Rayleigh scattered light is collected and fiber-optically transmitted to the spectral analysis and detection equipment. The spectrum of the light, which contains information about the temperature and velocity of the flow, is analyzed using a Fabry-Perot interferometer. Photomultipler tubes operated in the photon counting mode allow high frequency sampling of the circular interference pattern to provide time-resolved flow property measurements. Mean and rms velocity and temperature fluctuation measurements in both an electrically-heated jet facility with a 10-mm diameter nozzle and also in a hydrogen-combustor heated jet facility with a 50.8-mm diameter nozzle at NASA Glenn Research Center are presented.

Mielke, Amy F.↗

Two-dimensional electronic spectroscopy based on conventional optics and fast dual chopper data acquisition

We report an improved experimental scheme for two-dimensional electronic spectroscopy (2D-ES) based solely on conventional optical components and fast data acquisition. This is accomplished by working with two choppers synchronized to a 10 kHz repetition rate amplified laser system. We demonstrate how scattering and pump-probe contributions can be removed during 2D measurements and how the pump probe and local oscillator spectra can be generated and saved simultaneously with each population time measurement. As an example the 2D-ES spectra for cresyl violet were obtained. The resulting 2D spectra show a significant oscillating signal during population evolution time which can be assigned to an intramolecular vibrational mode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel system for measurement of the transverse electron momentum distribution from photocathodes

The transverse momentum of electrons produced by a photocathode contributes significantly to the performance of several different types of accelerator-based light sources, such as Free Electron Lasers, as well as systems designed for ultrafast electron diffraction and dynamic transmission electron microscopy. Minimization of the transverse emittance from photocathodes is the subject of intensive research, and therefore measurement of this parameter is of great importance. Here, we describe a simple system that offers real time measurements of transverse emittance and can be easily integrated into the photocathode fabrication process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inspecting the minefield and residual explosives by fast neutron activation method

As an upgrade of a robotic mobile system for antipersonnel land-mine clearance, a fast neutron probe has been considered for the detection of mines and explosive residues. Laboratory tests were made by using the 14 MeV 6 x 10{sup 7} neutrons/sec beam with the associated alpha particle detection and with a LaBr{sub 3} gamma ray detector. Simulant of the anti-personal mine was used as a target. Several measurements were made with the target buried into the soil at different depths. For each depth minimal time measurement was estimated for false negative 0.4 % and false positive equal to 10 %. Tests showed that is possible to detect buried land-mine as well as residual explosives; however, in order to reach the optimal speed of 10 cm/s for de-mining vehicle it is necessarily to use several sealed tube neutron generators and few tens of LaBr{sub 3} gamma ray detectors. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deuterated-xylene (xylene-d 10 ; EJ301D): A new, improved deuterated liquid scintillator for neutron energy measurements without time-of-flight

In conjunction with Eljen Technology, Inc. (Sweetwater,TX) we have designed, constructed, and evaluated a 3 in. x 3 in. deuterated-xylene organic liquid scintillator (C 8 D 10 ; EJ301D) as a fast neutron detector. Similar to deuterated benzene (C 6 D 6 ; NE230, BC537, and E1315) this scintillator can provide good pulse shape discrimination between neutrons and gamma rays, has good timing characteristics, and can provide a light spectrum with peaks corresponding to discrete neutron energy groups up to ca. 20 MeV. Unlike benzene -based detectors, deuterated xylene is less volatile, less toxic, is not known to be carcinogenic, has a higher flashpoint, and hence is much safer for many applications. In addition E1301D can provide slightly more light output and better PSD than deuterated-benzene scintillators. We show that, as with deuterated-benzene scintillators, the light -response spectra can be unfolded to provide useable neutron energy spectra without need for time-of-flight (ToF). An array of these detectors arranged at many angles close to a reaction target can be much more effective ( x 10 to x 100 or more) than an array of long-path ToF detectors which must utilize a narrowly-bunched and pulse-selected beam. Here, as we demonstrate using a small Van de Graaff accelerator, measurements can thus be performed when a bunched and pulse -selected beam (as needed for time-of-flight) is not available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-308: Mobius FX Evaluation and Comparison Against a Commercial 4D Detector Array for VMAT Plan QA

Purpose: To evaluate the use of MobiusFX as a pre-treatment verification IMRT QA tool and compare it with a commercial 4D detector array for VMAT plan QA. Methods: 15 VMAT plan QA of different treatment sites were delivered and measured by traditional means with the 4D detector array ArcCheck (Sun Nuclear corporation) and at the same time measurement in linac treatment logs (Varian Dynalogs files) were analyzed from the same delivery with MobiusFX software (Mobius Medical Systems). VMAT plan QAs created in Eclipse treatment planning system (Varian) in a TrueBeam linac machine (Varian) were delivered and analyzed with the gamma analysis routine from SNPA software (Sun Nuclear corporation). Results: Comparable results in terms of the gamma analysis with 99.06% average gamma passing with 3%,3mm passing rate is observed in the comparison among MobiusFX, ArcCheck measurements, and the Treatment Planning System dose calculated. When going to a stricter criterion (1%,1mm) larger discrepancies are observed in different regions of the measurements with an average gamma of 66.24% between MobiusFX and ArcCheck. Conclusion: This work indicates the potential for using MobiusFX as a routine pre-treatment patient specific IMRT method for quality assurance purposes and its advantages as a phantom-less method which reduce the time for IMRT QA measurement. MobiusFX is capable of produce similar results of those by traditional methods used for patient specific pre-treatment verification VMAT QA. Even the gamma results comparing to the TPS are similar the analysis of both methods show that the errors being identified by each method are found in different regions. Traditional methods like ArcCheck are sensitive to setup errors and dose difference errors coming from the linac output. On the other hand linac log files analysis record different errors in the VMAT QA associated with the MLCs and gantry motion that by traditional methods cannot be detected.

60 APPLIED LIFE SCIENCES↗

Time and frequency measuring metrological equipment in the USSR

The complex of the means of providing time and frequency traceability in the USSR includes the system of time and frequency standards of the National Time and Frequency Calibration Service, time and frequency transfer facilities and local time and frequency standards. Control on measurement correctness is performed by the All-Union State Standard calibration service. The hardware of most of the above-mentioned systems is provided by the instruments developed by our institute. A common scientific and technological approach allowed us to create a unified system of time-frequency equipment composed of widely used serial instruments, sets, automated systems and complexes. Primary frequency standards of different classes, time and frequency references and instruments are based on the unified system. CH1-70 hydrogen frequency standard and its CH1-70A, CH1-80 modifications are used in the group time and frequency standards. Measuring time and data processing techniques, and also instrumentation specifications on the results of 10-year operation are given. The existing system provides time-frequency measurements with 2 times 10(exp -13) plus or minus 1 times 10(exp -14) accuracy.

Uljanov, Adolph A.↗

Decomposing generalized measurements into continuous stochastic processes

One of the broadest concepts of measurement in quantum theory is the generalized measurement. Another paradigm of measurement--arising naturally in quantum optics, among other fields--is that of continuous-time measurements, which can be seen as the limit of a consecutive sequence of weak measurements. They are naturally described in terms of stochastic processes, or time-dependent random variables. We show that any generalized measurement can be decomposed as a sequence of weak measurements with a mathematical limit as a continuous stochastic process. We give an explicit construction for any generalized measurement, and prove that the resulting continuous evolution, in the long-time limit, collapses the state of the quantum system to one of the final states generated by the generalized measurement, being decomposed, with the correct probabilities. A prominent feature of the construction is the presence of a feedback mechanism--the instantaneous choice weak measurement at a given time depends on the outcomes of earlier measurements. For a generalized measurement with n outcomes, this information is captured by a real n-vector on an n-simplex, which obeys a simple classical stochastic evolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-resolved PIV measurements in a low-aspect ratio facility of randomly packed spheres and flow analysis using modal decomposition

This work experimentally investigated the flow characteristics in a facility with randomly packed spheres at a low-aspect ratio of 4.4. Velocity fields in the near-wall region and in the pores between spheres were obtained by employing the matched-index-of-refraction (MIR) and time-resolved particle image velocimetry (TR-PIV) techniques for Reynolds numbers of 340, 520, and 720. From the obtained TR-PIV velocity vector fields, flow characteristics including first- and second-order statistics, such as mean velocity, root-mean-square fluctuating velocity, and Reynolds stress profiles, were computed. The effects of the wall enclosure and Reynolds numbers on the flow patterns were investigated by comparing the computed flow statistics and evaluating two-point cross correlations of the velocities measured adjacent to and far from the wall. Comparisons of the mean velocities, root-mean-square fluctuating velocities, and Reynolds stress component showed an increase in flow mixing and turbulent intensity in the gaps between spheres in the packed bed. The re-circulation-region sizes, however, were found to be independent from an increase in Reynolds numbers. Finally, flow modal decompositions, such as the proper orthogonal decomposition (POD) and dynamic mode decomposition (DMD), were applied to the vorticity fields extracted from sub-regions located near and far from the wall to reveal the most dominant POD and DMD flow structures.

42 ENGINEERING↗

MPACT Fast Neutron Multiplicity System Design Concepts

This report documents work performed by Idaho National Laboratory and the University of Michigan in fiscal year (FY) 2012 to examine design parameters related to the use of fast-neutron multiplicity counting for assaying plutonium for materials protection, accountancy, and control purposes. This project seeks to develop a new type of neutron-measurement-based plutonium assay instrument suited for assaying advanced fuel cycle materials. Some current-concept advanced fuels contain high concentrations of plutonium; some of these concept fuels also contain other fissionable actinides besides plutonium. Because of these attributes the neutron emission rates of these new fuels may be much higher, and more difficult to interpret, than measurements made of plutonium-only materials. Fast neutron multiplicity analysis is one approach for assaying these advanced nuclear fuels. Studies have been performed to assess the conceptual performance capabilities of a fast-neutron multiplicity counter for assaying plutonium. Comparisons have been made to evaluate the potential improvements and benefits of fast-neutron multiplicity analyses versus traditional thermal-neutron counting systems. Fast-neutron instrumentation, using for example an array of liquid scintillators such as EJ-309, have the potential to either a) significantly reduce assay measurement times versus traditional approaches, for comparable measurement precision values, b) significantly improve assay precision values, for measurement durations comparable to current-generation technology, or c) moderating improve both measurement precision and measurement durations versus current-generation technology. Using the MCNPX-PoliMi Monte Carlo simulation code, studies have been performed to assess the doubles-detection efficiency for a variety of counter layouts of cylindrical liquid scintillator detector cells over one, two, and three rows. Ignoring other considerations, the best detector design is the one with the most detecting volume. However, operational limitations guide a) the maximum acceptable size of each detector cell (due to PSD performance and maximum-acceptable per-channel data throughput rates, limited by pulse pile-up and the processing rate of the electronics components of the system) and b) the affordability of a system due to the number of total channels of data to be collected and processed. As a first estimate, it appears that a system comprised of two rows of detectors 5" Ø $\times$ 3" would yield a working prototype system with excellent performance capabilities for assaying Pu-containing items and capable of handling high signal rates likely when measuring items with Pu and other actinides. However, it is still likely that gamma-ray shielding will be needed to reduce the total signal rate in the detectors. As a first step prior to working with these larger-sized detectors, it may be practical to perform scoping studies using small detectors, such as already-on-hand 3" Ø $\times$ 3" detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗