Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THERMOCOUPLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

High-Precision Temperature Control of a Crystal Growth Furnace at 1,500 C

For crystal growth of semiconductor materials a short-term temperature stability of 0.1 C at 1500 C is one of the essential parameters to be addressed for achieving high-quality crystals. Hence, for temperature monitoring and control with high precision in a floating zone furnace two sets of thermo-sensors, type B thermocouples and optical fibre thermometers, have been implemented and successfully operated in the furnace for more than 2000 h. The optical fibre thermometers consist of an optical system made of sapphire (two fibres plus a prism in between for deflection) and transmit the infra-red radiation of the heater to the outside of the hot core of the furnace for pyrometric temperature measurement. A dedicated control algorithm has been set up which controlled the power settings to the individual heaters. Both sensor types showed no degradation after this period and yielded a short-term stability at 1200 C of 0.05 C (optical fibre thermometers), respectively 0.08 C (thermocouples).

Stenzel, Ch.↗

Thermography Used to Test Conductivity of Carbon Based Cloth

Testing of the ability of carbon fiber to radiatively cool a heat source. The carbon fibers are attached to a heat source. The heat conducts into the fiber than along the fiber away from the heat source. The test are done in a vacuum chamber (10-5 Torr typical). The IR camera is viewing the fiber through a ZnSe window. A thermocouple (TC) in contact with the fiber is at the top right hand side of the area of interest and one is near the bottom. Thin shielding fins, seen edge on, are just above the top thermocouple.

Craven, Paul↗

Test Facility Simulation Results for Aerospace Loss-of-Lubrication of Spur Gears

Prior to receiving airworthiness certification, extensive testing is required during the development of rotary wing aircraft drive systems. Many of these tests are conducted to demonstrate the drive system's ability to operate at extreme conditions, beyond that called for in the normal to maximum power operating range. One of the most extreme tests is referred to as the loss-of-lubrication or run dry test. During this test, the drive system is expected to last at least 30 min without failure while the primary lubrication system is disabled for predetermined, scripted flight conditions. Failure of this test can lead to a partial redesign of the drive system or the addition of an emergency lubrication system. Either of these solutions can greatly increase the aircraft drive system cost and weight and extend the schedule for obtaining airworthiness certification. Recent work at NASA Glenn Research Center focused on performing tests, in a relevant aerospace environment, to simulate the behavior of spur gears under loss-of-lubrication conditions. Tests were conducted using a test facility that was used in the past for spur gear contact fatigue testing. A loss-oflubrication test is initiated by shutting off the single into mesh lubricating jet. The test proceeds until the gears fail and can no longer deliver the applied torque. The observed failures are typically plastically deformed gear teeth, due to the high tooth temperatures, that are no longer in mesh. The effect of several different variables to gear tooth condition during loss-of-lubrication have been tested such as gear pitch, materials, shrouding, lubrication condition, and emergency supplied mist lubrication in earlier testing at NASA. Recent testing has focused on newer aerospace gear steels and imbedding thermocouples in the shrouding to measure the air-oil temperatures flung off the gear teeth. Along with the instrumented shrouding, an instrumented spur gear was also tested. The instrumented spur gear had five thermocouples installed at different locations on the gear tooth and web. The data from these two types of measurements provided important information as to the thermal environment during the loss-of-lubrication event. This data is necessary to validate on-going modeling efforts.

Gears↗

Thermal Behavior of Aerospace Spur Gears in Normal and Loss-of-Lubrication Conditions

Testing of instrumented spur gears operating at aerospace rotorcraft conditions was conducted. The instrumented gears were operated in a normal and in a loss-of-lubrication environment. Thermocouples were utilized to measure the temperature at various locations on the test gears and a test utilized a full-field, high-speed infrared thermal imaging system. Data from thermocouples was recorded during all testing at 1 Hz. One test had the gears shrouded and a second test was run without the shrouds to permit the infrared thermal imaging system to take date during loss-of-lubrication operation. Both tests using instrumented spur gears were run in normal and loss-of-lubrication conditions. Also the result from four other loss-of-lubrication tests will be presented. In these tests two different torque levels were used while operating at the same rotational speed (10000 rpm).

Gears↗

Orion EFT-1 Cavity Heating Tile Experiments and Environment Reconstruction

Developing aerothermodynamic environments for deep cavities, such as those produced by micrometeoroids and orbital debris impacts, poses a great challenge for engineers. In order to assess existing cavity heating models, two one-inch diameter cavities were flown on the Orion Multi-Purpose Crew Vehicle during Exploration Flight Test 1 (EFT1). These cavities were manufactured with depths of 1.0 in and 1.4 in, and they were both instrumented. Instrumentation included surface thermocouples upstream, downstream and within the cavities, and additional thermocouples at the TPS-structure interface. This paper will present the data obtained, and comparisons with computational predictions will be shown. Additionally, the development of a 3D material thermal model will be described, which will be used to account for the three-dimensionality of the problem when interpreting the data. Furthermore, using a multi-dimensional inverse heat conduction approach, a reconstruction of a time- and space-dependent flight heating distribution during EFT1 will be presented. Additional discussions will focus on instrumentation challenges and calibration techniques specific to these experiments. The analysis shown will highlight the accuracies and/or deficiencies of current computational techniques to model cavity flows during hypersonic re-entry.

Salazar, Giovanni↗

Dynamic Temperature and Pressure Measurements in the Core of a Propulsion Engine

Dynamic temperature and pressure measurements were made in the core of a TECH977 propulsion engine as part of a NASA funded investigation into indirect combustion noise. Dynamic temperature measurements were made in the combustor, the inter-turbine duct, and the mixer using ten two-wire thermocouple probes. Internal dynamic pressure measurements were made at the same locations using piezoresistive transducers installed in semi-infinite coils. Measurements were acquired at four steady state operating conditions covering the range of aircraft approach power settings. Fluctuating gas temperature spectra were computed from the thermocouple probe voltage measurements using a compensation procedure that was developed under previous NASA test programs. A database of simultaneously acquired dynamic temperature and dynamic pressure measurements was produced. Spectral and cross-spectral analyses were conducted to explore the characteristics of the temperature and pressure fluctuations inside the engine, with a particular focus on attempting to identify the presence of indirect combustion noise.

Turbomachinery Noise↗

Thermal Behavior of Aerospace Spur Gears in Normal and Loss-of-Lubrication Conditions

Testing of instrumented spur gears operating at aerospace rotorcraft conditions was conducted. The instrumented gears were operated in a normal and in a loss-of-lubrication environment. Thermocouples were utilized to measure the temperature at various locations on the test gears and a test utilized a full-field, high-speed infrared thermal imaging system. Data from thermocouples was recorded during all testing at 1 hertz. One test had the gears shrouded and a second test was run without the shrouds to permit the infrared thermal imaging system to take data during loss-of-lubrication operation. Both tests using instrumented spur gears were run in normal and loss-of-lubrication conditions. Also the result from four other loss-of-lubrication tests will be presented. In these tests two different torque levels were used while operating at the same rotational speed (10000 revolutions per minute).

Gears↗

Characterization of Ablation Product Radiation Signatures of PICA and FiberForm

Emission spectroscopy measurements in the post-shock layer in front of low density ablative material samples of different shapes were obtained in the NASA Langley HYMETS arcjet facility. A horizontal line of measurement positions was imaged on the entrance slit of the spectrometer allowing detection of the entire stagnation line in front of the samples. The stagnation line measurements were used to compare the post-shock layer emission signatures in front of PICA and FiberForm. The emission signatures of H, NH, and OH are characteristic for pyrolysis gases and consequently were only observed in front of the PICA samples. CN and C were found in front of both materials and are mainly due to interactions of the carbon fibers with the plasma. In all tests with instrumented samples, the emission of Mn, Cr, and Ni was observed when the thermocouple temperatures reached or exceeded ~1,500 K, strongly indicating erosion of the molten thermocouple tips. Temperatures in the post-shock layer were estimated from comparing the CN band emission to spectral simulation. The resulting rotational and vibrational temperatures were on the order of 7,000 to 9,000 K and close to each other indicating a plasma condition close to equilibrium. In addition to the stagnation line configurations, off-axis lines of observation were investigated to gather information about spalled particles in the flow. From a comparison of measured continuum emission with simulated Planck radiation, average particle temperatures along the measured line of observation were determined for two cases. Particle temperatures between 3,500 and 2,000 K were found. A comprehensive investigation of the entire amount of data set is ongoing.

Winter, Michael↗

Microgravity Experiments of Solid Waste Conversion into Useful Commodities

This Summer I participated in two projects at Kennedy Space Center in Cape Canaveral, Florida. The projects focus on the NASA's Deep Space Gateway applications for future Mars travel. All of these projects use recycling technology to use resources found on Earth and on other planets for fuel and other environmental applications. The first project I took the lead on is “Plasma Arc Gasification.” Plasma is a high temperature and very efficient way to process waste to create usable byproducts. The plasma chamber in temperature is comparable to that of the sun and this energy will help create an environment in which the waste can be recycled properly for not only plant support, but also for possible fuel application as well. I preformed the tests in a quartz tube, which is used to hold the waste (cotton, plastics, nylon, paper and a human waste simulant) and the waste is then combusted using O2 (present in air) into gases such as H2, H2O, CH4 and CO2. I determined which gases are present using a Fourier-transform infrared spectroscopy (FTIR) machine, which analyzes the peaks of the gases using liquid nitrogen. Problems arose in the beginning from the reactor emitting electromagnetic waves (EMI) that interfered with the technology of the experiment, specifically the thermocouples. This was solved through multiple tests with the positioning of the thermocouple power supply further away from the plasma reactor. I worked with another intern, Daniel Santander, who developed a space plant chamber which uses CO2 and H2O (harvested from the plasma reactor) to grow plants in space. The chamber possess a CO2 monitor, which controls the amount of gas that enters the chamber, along with a water integration system to supply the amount of water needed for proper plan growth. This technology will then be used for plant growth in space for the Astronauts on future space flights and possibly on the International Space Station (ISS). The second project I worked on is the “Orbital Syngas / Commodity Augmentation Reactor (OSCAR)” which focuses on the issues experienced in long-duration space flight regarding waste disposal. In previous space flight missions, waste was stored on board and returned to Earth for disposal. This technique is not applicable to long space flight missions to Mars due to the rocket being months away from Earth. OSCAR is using microgravity waste disposal techniques to produce fuels from the recycled waste. The waste is converted to syngas through a thermal degradation process. This process helps create an environmentally friendly way to dispose and reuse trash on board the space craft. Currently waste is being tested in the form of cotton and plastics. OSCAR is designed as a microgravity reactor that is currently being tested in a drop tower rig at Glenn Research Center. I helped design the 3D model for the insulation that will line the reactor. The first few trials, I dissolved the plastic of the mold in acetone. This method worked, but was very costly. I then received a silicone material to construct the mold from Swamp Works here at Kennedy. Through multiple trials with the silicone, this method worked best for developing the end pieces of the insulation for the chamber.

Plasma↗

Analysis of the Honeywell Uncertified Research Engine (HURE) with Ice Crystal Cloud Ingestion at Simulated Altitudes: Public Version

The Honeywell Uncertified Research Engine (HURE), a research version of a turbofan engine that never entered production, was tested in the NASA Propulsion System Laboratory (PSL), an altitude test facility at the NASA Glenn Research Center. The PSL is a facility that is equipped with water spray bars capable of producing an ice cloud consisting of ice particles, having a controlled particle diameter and concentration in the air flow. In preparation for testing of the HURE, numerical analysis of flow and ice particle thermodynamics was performed on the compression system of the turbofan engine to predict operating conditions that could potentially result in a risk of ice accretion due to ice crystal ingestion. The results of those analyses formed the basis of the test matrix. The goal of the test matrix was to have ice accrete in two regions of the compression system: region one, which consists of the fan-stator through the inlet guide vane (IGV), and region two which is the first stator within the high pressure compressor. The predictive analyses were performed with the mean line compressor flow modeling code (COMDES-MELT) which includes an ice particle model. Together these comprise a one-dimensional icing tool. The HURE engine was tested in PSL with the ice cloud over the range of operating conditions of altitude, ambient temperature, simulated flight Mach number, and fan speed with guidance from the analytical predictions. The engine was fitted with video cameras at strategic locations within the engine compression system flow path where ice was predicted to accrete, in order to visually confirm ice accretion when it occurred. In addition, traditional compressor instrumentation such as total pressure and temperature probes, static pressure taps, and metal temperature thermocouples were installed in targeted areas where the risk of ice accretion was expected. The current research focuses on the analysis of the data that was obtained after testing the HURE engine in PSL with ice crystal ingestion. The computational method was enhanced by computing key parameters through the fan-stator at multiple spanwise locations, in order to increase the fidelity with the current mean-line method. In addition, other sources of heat (non-adiabatic walls) were suspected to be the cause of accretion near the splitter-lip and shroud. Since there were no thermocouples near the splitter, a simple order of magnitude heat transfer model was implemented to estimate the wall temperature. Future analyses will require a higher fidelity thermal analysis of the compression system metal walls to accurately calculate the total heat flux to the ice particle. For many data points analyzed, there were differences between the thermodynamic system model and the measured test data that may partially be responsible for uncertainties with the results of the current analyses.

Turbomachinery↗

Simulation Schiaparelli's Entry and Comparison to Aerothermal Flight Data

The European Space Agency recently flew an entry, descent, and landing demonstrator module called Schiaparelli that entered the atmosphere of Mars on the 19th of October, 2016. The instrumentation suite included heatshield and backshell pressure transducers and thermocouples (known as AMELIA - Atmospheric Mars Entry and Landing Investigations and Analysis) and backshell radiation and direct heat flux-sensing sensors (known as COMARS (Combined Aerothermal and Radiometer Sensors Instrument Package) and ICOTOM (narrow band radiometers)). Due to the failed landing of Schiaparelli, only a subset of the flight data was transmitted before and after plasma black-out. The goal of this paper is to present comparisons of the flight data with calculations from NASA simulation tools, DPLR (Data Parallel Line Relaxation) / NEQAIR (NonEQuilibrium AIr Radiation) and LAURA (Langley Aerothermodynamic Upwind Relaxation Algorithm) / HARA (High-temperature Aerothermodynamic RAdiation ). DPLR and LAURA are used to calculate the flowfield around the vehicle and surface properties, such as pressure and convective heating. The flowfield data are passed to NEQAIR and HARA to calculate the radiative heat flux. Comparisons will be made to the COMARS total heat flux, radiative heat flux and pressure measurements. Results will also be shown against the reconstructed heat flux which was calculated from an inverse analysis of the AMELIA thermocouple data performed by Astrium. Preliminary calculations are presented in this abstract.

Brandis, A. M.↗

Thermal Modeling and Correlation of the Space Environments Complex Vacuum Chamber and Cryoshroud

From Presentation: Formerly known as the Space Power Facility (SPF) Located at Plum Brook Station in Sandusky, OH -- Houses large-scale test facilities including the Space Simulation Vacuum Chamber -- Largest vacuum chamber in the world -- 100 ft diameter, 122 ft tall -- Cryoshroud operates between -250 °F and +140 °F -- To be used for Orion EM-1 thermal vacuum test -- Thermal Desktop model of vacuum chamber, cryoshroud, mechanical ground support equipment (MGSE) including fluid model of GN2 -- Primary uses: Predict MGSE temperatures; Predict heat load on GN2 system -- Includes 96 TD Temperature Measures that represent test thermocouples -- Steady state correlation with 3 tests: 2 hot; 1 cold -- Two ISTs performed with no MGSE inside the cryoshroud: Insulated test: operated at 170 °F for 37 hours; Uninsulated test: operated at 170 °F for 14 days -- Only cryoshroud thermocouples were installed

Thermal modeling↗

MEDLI2 Flight Heat Flux Sensor Environment and Planetary Protection Testing

Mars 2020 will fly the Mars Entry, Descent, and Landing Instrumentation II (MEDLI2) sensor suite consisting of a total of seventeen instrumented thermocouple sensor plugs, eight pressure transducers, two total heat flux sensors, and one radiometer embedded in the thermal protection system (TPS). Of the MEDLI2 instrumentation, eleven instrumented thermocouple plugs and seven pressure transducers will be installed on the heatshield of the Mars 2020 vehicle while the rest will be installed on the backshell. The goal of the MEDLI2 instrumentation is to directly inform the large performance uncertainties that contribute to the design and validation of a Mars entry system. A better understanding of the entry environment and TPS performance could lead to reduced design margins enabling greater payload mass-fraction and smaller landing ellipses. The MEDLI2 total heat flux sensors and radiometer are new instruments that were not flown on the Mars Science Laboratory mission. These sensors directly measure the surface heat flux and radiation at specific backshell locations. The total heat flux sensors use a Schmidt-Boelter sensing element. The radiometer version uses a sapphire window placed over the Schmidt-Boelter sensing element to separate the radiative component of the total heat flux. MEDLI2 recently planned and executed protoflight environmental testing as well planetary protection measures on the flight and flight-spare total heat flux sensors and radiometers. This testing is required to provide confidence in the performance of the flight-lot sensors when exposed to flight-like environments, and to reduce the risk of biological contamination on the planet of Mars with microbes from Earth.

MEDLI2 FLIGHT HEAT FLUX SENSOR ENVIRONMENT AND PLA↗

Reconstruction of Schiaparelli and Comars Flight Data

ESA recently flew an entry, descent, and landing demonstrator module called Schiaparelli that entered the atmosphere of Mars on the 19th of October, 2016. The instrumentation suite included heatshield and backshell pressure transducers and thermocouples (known as AMELIA) and backshell radiation and direct heatflux-sensing sensors (known as COMARS and ICOTOM). Due to the failed landing of Schiaparelli, only a subset of the flight data was transmitted before and after plasma black-out. The goal of this paper is to present comparisons of the flight data with calculations from NASA simulation tools, DPLR/NEQAIR and LAURA/HARA. DPLR and LAURA are used to calculate the flowfield around the vehicle and surface properties, such as pressure and convective heating. The flowfield data are passed to NEQAIR and HARA to calculate the radiative heat flux. Comparisons will be made to the COMARS total heat flux, radiative heat flux and pressure measurements. Results will also be shown against the reconstructed heat flux which was calculated from an inverse analysis of the AMELIA thermocouple data performed by Astrium. Preliminary calculations are presented in this abstract. The aerodynamics of the vehicle and certain as yet unexplained features of the inverse analysis and forebody data will be investigated.

Schiaparelli↗

Thermal History Mapping Technology for Turbine Engine Diagnostics

The infusion of ceramic matrix composites (CMCs) in next generation gas turbines represents daunting challenges as the failure of protective coating, known as Environmental Barrier Coating (EBC), means little remnant life of CMC components. Consequently reliable lifing is critical to the success of CMC components. Accurate thermal mapping of EBC in rig and engine test is of paramount importance because temperature is the most critical variable for EBC life. Current temperature measurement technologies include thermocouples, pyrometers, IR cameras, and thermal paints. Thermocouples require a passage to access the components and pyrometers and IR cameras require line-of-sight. Thermal paints are based on color-sensitive pigments that visually indicate the temperature that a component experienced. Thermal paints do not require line-of-sight, however, they have a low resolution and a limited temperature capability (~1400°C). Thermal history coating is based on oxide ceramic which luminesces when excited with a light source. The luminescence changes when the material's structure changes triggered by heat impact. The maximum temperature to which the material was exposed can be determined from the luminescence change. This paper describes the principles of this new technique and demonstrates its capabilities for EBCs exposed to excess of 1500°C.

Lee, Kang N.↗

Bayesian Inference and the Effects of Varying Uncertainty Models in Charring Ablator Calibration and Uncertainty Quantification Problems

The Mars Science Laboratory (MSL) vehicle utilized a heat shield constructed from NASA’s Phenolic-Impregnated Carbon Ablator (PICA) material to protect the main structure from the high enthalpy environment encountered during hypersonic atmospheric entry. During the vehicle’s descent through Martian atmosphere, multiple thermocouples embedded within the heat shield captured in-depth material temperature data that allow for studies to be conducted on current material response reconstruction tools. In the present work, material temperature data obtained from thermocouples within the MISP-4 plug (MEDLI (Mars Science Laboratory Entry, Descent, and Landing Instrument) Integrated Sensor Plug) are utilized in the calibration of Theoretical Ablative Composite for Open Testing (TACOT) model parameters in conjunction with NASA’s Porous material Analysis Toolbox (PATO) through Bayesian inference where uncertainty due to parametric, modeling, and experimental sources is simultaneously quantified. Prior to the study, a sensitivity analysis is performed through computation of the robust Sobol indices in an effort to study the relationship between input space and model response and to reduce the dimensionality of the statistical inverse problem. The Bayesian inference methodology necessitates an a-priori choice to be made for the uncertainty model for which numerous possibilities are available. Across most works, however, only basic additive or multiplicative models are utilized with pre-defined magnitudes of uncertainty based on a-priori knowledge or to-be-calibrated multipliers of static covariance matrix structures. The present effort explores the effects of informed uncertainty models, ones with temporal dependence that are simultaneously calibrated through Bayesian inference, on calibrated results for parameters that make up the uncertain input space.

Sensitivity Analysis↗

Evaluation of Temperature Gradients During Cure of a Thick Carbon Fiber/Epoxy Composite

The purpose of this study is to evaluate the development of thermal gradients throughout thick (1") carbon fiber composites and determine the effect of internal temperature distribution during cure on the observed mechanical properties in those composites. Composites up to 1.5" thick (56 plies) were fabricated with T700S/TC380 braided prepreg from Tencate following a modified vacuum bag layup procedure to include embedded thermocouples within the plies of the composite. Composite panels were cured in a programmable oven with thermocouple reading embedded throughout the panel thickness. Maximum temperature gradients measured between regions of the composite did not exceed 10 degrees C for any given composite thickness. The most significant temperature variation was measured between the mid-thickness plies and the tool-side surface plies. Although through thickness temperature variation during cure was small, a measureable variation in coupon glass transition temperature was recorded between the tool side plies and the remainder of the part, prior to post cure. Thermal and mechanical behavior of coupons taken from segments through the thickness of the part were comparable following a post-cure cycle.

Miller, Sandi↗

Revisiting MEDLI with Improved Modeling and Simulation Tools

The thermal protection system (TPS) of the Mars 2020 capsule will carry a suite of sensors called MEDLI2 (Mars Entry, Descent, and Landing Instrument 2). This suite consists of pressure sensors/transducers and thermocouple plugs meant to measure atmospheric properties, vehicle attitude, TPS performance, etc. While the suite is similar to that carried on the successful MSL (Mars Science Laboratory) mission in 2012, it now includes pressure sensors, thermocouple plugs, and radiometers on the backshell as well. An analysis plan is therefore necessary to help with the interpretation of flight measurements.

Atmospheric Entry↗