Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TANK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Evaluation of Long Term Microbial Regrowth in Slosh Water Tanks From the International Space Station

The NASA Launch Services Program (LSP) maintained the SPHERES-Slosh experiment aboard the International Space Station (ISS) between 2013 and 2019. The purpose of the Slosh experiment was to examine how liquids move inside fuel tanks in a microgravity environment. These tanks were similar to water storage tanks planned for use aboard future space systems, where large dormant periods between crew-use will provide similar conditions for biological growth or chemical leaching. The water within the SLOSH tanks remained undisturbed for over five years after testing concluded, providing a unique sample for stored water under microgravity conditions without prior protocols for microbial control such as sterilization or addition of biocides. The Slosh storage tanks were returned to Kennedy Space Center (KSC) aboard SpaceX CRS-18 mission in November 2019. Upon return of the tanks, the water within each tank was analyzed to determine how the water chemistry and biology changed during its tenure in microgravity. The data obtained and described within this publication provided a basis and reasoning for planning water storage and purification treatment methods aboard ISS, Gateway, and future space habitats. Results demonstrated that low microbial concentrations were present within the water, as expected since no biocide treatment was employed, yet no extensive biofilm formation was observed after 5 years even in the presence of microbial food sources such as the polycarbonate structure and food color additives. This experimentation demonstrates that future biofilm studies should be performed on this type of experimental setup with proper controls aboard ISS to examine microbial regrowth to improve microbial control within space water systems.

Luke B. Roberson↗

The ZBOT-NC Experiment - Effects of Non-Condensable Gases on Propellant Tank Pressurization and Pressure Control

Introduction Integral to all phases of NASA’s projected planetary expeditions is affordable and reliable cryogenic fluid storage for use in propellant or life support systems. It is greatly advantageous to develop innovative vent-less pressure control designs based on cooling/mixing of the bulk tank fluid to allow storage of the cryogenic fluid with zero or reduced boil-off. The presence of noncondensable gases, can interfere with the condensation at the interface impacting tank pressure control during subcooled jet mixing especially in microgravity. The Zero-Boil-Off Tank (ZBOT) Experiments are a series of small-scale experiments aboard the International Space Station (ISS) that use a transparent volatile simulant fluid in a transparent sealed tank to delineate various fundamental fluid flow, heat and mass transport, and phase change phenomena associated with storage tank pressurization and pressure control in microgravity. The ZBOT-1 experiment was performed on the ISS 2017-2018 timeframe and collected data to validate a state-of-the-art CFD model for tank pressurization and pressure control for a pure system. The ZBOT-NC Experiment is the second experiment in the series to be performed on the International Space Station (ISS) in 2025. Its goal is to investigate the effects of noncondensable gases on interfacial evaporation and condensation during self -pressurization and jet-mixing pressure control in microgravity for a two-component system. Materials & Methods In this work, we will describe the detailed features of the ZBOT-NC experimental hardware and Diagnostics that includes nonintrusive Quantum Dot Thermometry (QDT) for whole field temperature measurement. All microgravity pressurization and pressure control tests will be performed for both the pure and the two-components systems with Xenon and Neon as the two noncondensable gases spanning small and large molecular weights and sizes. The two-phase CFD model that is developed as part of the project will be also presented and discussed. Results Ground-based pressurization and jet mixing experiments and CFD simulation results are compared to each other to validate both the fidelity of the CFD model predictions and the accuracy of the QDT measurement. Model simulations for noncondensable gas effects will also be compared against large Cryogenic LH2-GHe experiments to indicate the noncondensable gas effects on tank pressure control during jet mixing in 1G. Finally, CFD results will be presented to predict the effects of the noncondensable gas during subcooled jet mixing during the ZBOT-NC in advance of the microgravity experiment in 2015.

Evaporation Condensation↗

Hanford Tank Waste - Near Source Treatment of Low Activity Waste

Abstract only. Treatment and disposition of Hanford Site waste as currently planned consists of 100+ waste retrievals, waste delivery through up to 8+ miles of dedicated, in-ground piping, centralized mixing and blending operations- all leading to pre-treatment combination and separation processes followed by vitrification at the Hanford Tank Waste Treatment and Immobilization Plant (WTP). The sequential nature of Tank Farm and WTP operations requires nominally 15-20 years of continuous operations before all waste can be retrieved from many Single Shell Tanks (SSTs). Also, the infrastructure necessary to mobilize and deliver the waste requires significant investment beyond that required for the WTP. Treating waste as closely as possible to individual tanks or groups- as allowed by the waste characteristics- is being investigated to determine the potential to 1) defer, reduce, and/or eliminate infrastructure requirements, and 2) significantly mitigate project risk by reducing the potential and impact of single point failures. The inventory of Hanford waste slated for processing and disposition as LAW is currently managed as high-level waste (HLW), i.e., the separation of fission products and other radionuclides has not commenced. A significant inventory of this waste (over 20M gallons) is in the form of precipitated saltcake maintained in single shell tanks, many of which are identified as potential leaking tanks. Retrieval and transport (as a liquid) must be staged within the waste feed delivery capability established by site infrastructure and WTP. Near Source treatment, if employed, would provide for the separation and stabilization processing necessary for waste located in remote farms (wherein most of the leaking tanks reside) significantly earlier than currently projected. Near Source treatment is intended to address the currently accepted site risk and also provides means to mitigate future issues likely to be faced over the coming decades. This paper describes the potential near source treatment and waste disposition options as well as the impact these options could have on reducing infrastructure requirements, project cost and mission schedule.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Development of the Corrosion Control Limits for Direct Feed Low-Activity Waste Melter-Off Gas Returns to Hanford Tank Farms - 18196

The Savannah River National Laboratory has been developing a corrosion model to facilitate implementation of Hanford's Direct Feed Low Waste (DFLAW) flowsheet. Laboratory testing and statistical analysis have been used to determine the necessary corrosion controls for returning effluent from the Hanford Waste Treatment and Immobilization Plant's Low Activity Waste Vitrification melter off-gas treatment system to the tank farms. The stream compositions are projected to contain components at relative concentrations that are significantly more corrosive toward carbon steel, specifically halide and sulfate anions, than the current waste compositions in the tank farms. Administrative programs are in place to mitigate potential corrosion mechanisms and thereby maintain the structural and leak integrity functions of these waste tanks throughout their intended service life. Waste chemistry and temperature control are the means by which corrosion degradation of the waste tanks is minimized. The current administrative specification for chemical composition and temperature for the underground carbon steel waste tanks is not designed to control the higher halide or sulfate composition. The content of the DFLAW waste streams will be diverse and depend on several factors, such as the melter feed composition and melter idle time. Other factors, such as effluent management of the off gas water collections, will impact the variability of the return streams even more. The work performed by the Savannah River National Laboratory has confirmed that the halide ions are the most aggressive species in the return stream compositions projected using a flowsheet simulation, and nitrite is the most effective inhibitor at pH 10 and 40 deg. C. This test program has employed statistically designed test matrices to determine the dependent variables and the interaction terms between the variables that are significant for the corrosion model and definition of the corrosion control specifications. The first phase of testing focused on identifying aggressive species in off-gas condensate return compositions that present a propensity for localized corrosion attack, namely pitting corrosion. The second phase of testing focused on developing a corrosion model from the interaction terms that will predict the susceptibility of pitting in the double shell tank system based on waste composition and the required amount of corrosion inhibitor. The data collected from this testing program in conjunction with other testing programs, both at the Savannah River Site and the Hanford Site, along with operations knowledge, has determined the chemistry ranges and chemical species requirements for corrosion control in the Hanford double-shell tank system for the effluents generated in the Hanford Waste Treatment and Immobilization Plant's Low Activity Waste facility during the DFLAW phase of operations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a Trace Detection Method for Mercury Speciation in Hanford Tank Waste - 19014

The U.S. Department of Energy's (DOE) Hanford Site in southeast Washington State stores 56 million gallons of chemical and radioactive waste stored in underground tanks. Mercury species in liquid and solid fractions of Hanford tank waste pose a risk to the implementation and execution of DoE's River Protection Project mission due to mercury concentration limits imposed under waste acceptance criteria, toxicity characteristic leaching procedure restrictions for secondary waste disposal, and air emission permits. Although there is currently no processing of tank waste at Hanford, waste processing is imminent, and representative mercury inventory tracking will be important to anticipate and mitigate stack emissions and secondary liquid waste disposal issues. A methodology to accurately determine total mercury and mercury speciation in Hanford tank waste, while maintaining low mercury detection limits, currently does not exist at Hanford. Moreover, the mercury species in the waste solids are unknown and may be waste type-specific. The development of an analytical method to separate and speciate mercury in tank waste was undertaken by the Pacific Northwest National Laboratory (PNNL) while leveraging an existing non-radiological, ultra-trace mercury detection technique frequently performed at PNNL's Marine Sciences Laboratory in Sequim, Washington. The ultimate goal of this work is to develop an analytical method to obtain detailed mercury speciation information and update flowsheet modeling assumptions related to mercury partitioning at Hanford. The first phase of testing was completed in the development of an analytical methodology for the low-level determination of total mercury, elemental mercury, methylmercury, and dimethylmercury in Hanford tank waste. This paper presents Phase I testing which focused on determining whether mercury species can be preconcentrated from aqueous Hanford tank waste solution onto a solid substrate, while simultaneously eliminating or very significantly reducing the parent radionuclide activity. This was demonstrated by developing protocols for the separation and preconcentration of total mercury and methylmercury onto solid substrates, then measuring the substrates for radiological content at PNNL's Radiochemical Processing Laboratory on the Hanford Site. The mercury content was successfully separated onto stable substrates and the radionuclide activity reduction was significant enough that the preconcentrated samples could be subjected to quantification using far less restrictive handling and radiological controls than would be required for the parent sample (i.e., contamination area fume hood vs. hot cell). This mercury separation method required no sample dilution, which enables maximum mercury detectability, while still allowing mercury speciation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Update on Integrity Monitoring, Prediction and Assessment, Corrosion Control, and Repair of the Hanford Storage Tanks

DOE has launched a multi-year research program with the focus of preserving and increasing available volume for waste storage at Hanford. The long-term availability and operability of the Hanford Double Shell Tanks (DST) is critical to the completion of the Hanford mission. Maintaining the integrity of the tank will involve having a technology for repair or refurbishment of a DST should the tank function be compromised by degradation, monitoring the tank for indications of accelerated degradation, developing a means for mitigating accelerated degradation, and evaluating options for increasing the storage capacity in the tank farm without constructing new tanks. The project work was started in the middle of 2024; significant progress has been made in the following four areas: (i) tank refurbishment using a high performance grout and an epoxy sealant layer system, (ii) developing a chemically and radiologically stable reference electrode, (iii) designing and implementing a cathodic protection system to mitigate underside corrosion of DST secondary shells, and (iv) exploring evaporation to increase waste storage capacity.

Shukla, Pavan [Savannah River National Laboratory ↗

T-TY Tank Farm Interim Surface Barrier Demonstration—Vadose Zone Monitoring Plan

The Hanford Site has 149 underground single-shell tanks that store hazardous radioactive waste. Many of these tanks and their associated infrastructure (e.g., pipelines, diversion boxes) have leaked. Some of the leaked waste has entered the groundwater. The largest known leak occurred from the T-106 Tank of the 241-T Tank Farm in 1973. Five tanks are assumed to have leaked in the TY Farm. Many of the contaminants from those leaks still reside within the vadose zone within the T and TY Tank Farms. The Department of Energy’s Office of River Protection seeks to minimize the movement of these contaminant plumes by placing interim barriers on the ground surface. Such barriers are expected to prevent infiltrating water from reaching the plumes and moving them further. The soil water regime is monitored to determine the effectiveness of the interim surface barriers. Soil-water content and water pressure are monitored using off-the-shelf equipment that can be installed by the hydraulic hammer technique. Four instrument nests were installed in the T Farm in fiscal year (FY) 2006 and FY2007; two nests were installed in the TY Farm in FY2010. Each instrument nest contains a neutron probe access tube, a capacitance probe, and four heat-dissipation units. A meteorological station has been installed at the north side of the fence of the T Farm. This document summarizes the monitoring methods, the instrument calibration and installation, and the vadose zone monitoring plan for interim barriers in T farm and TY Farm.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization Results of SRS Tank 26 Samples FTF-26-19-12 and -13

Savannah River Remediation (SRR) has requested that the Savannah River National Laboratory (SRNL) characterize several samples from the Savannah River Site (SRS) Tank Farm in preparation for Sludge Batch (SB) 10. This report documents the characterization of Tank 26 material received by SRNL in May of 2019. SRR pulled 2 x 200 mL samples (FTF-26-19-12 and FTF-26-19-13) with Tank 26 slurry pumps at 60 inches. Two samples were taken to ensure SRNL has adequate material for the requested analyses. Because both samples were taken at the same time and at the same tank level, SRNL combined the two Tank Farm samples into one sample prior to analyses. Results presented in this report include: weight percent solids, density, elemental composition of supernate and slurry, Cs-137 in supernate and slurry, and slurry total alpha and beta. The sample contained higher than expected total sulfur with a significant insoluble fraction, prompting SRR-E to request a washing study to predict how sulfur will be removed during Tank Farm washing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Closure Report for Corrective Action Unit 121: Storage Tanks and Miscellaneous Sites, Nevada Test Site, Nevada

Corrective Action Unit (CAU) 121 is identified in the Federal Facility Agreement and Consent Order (FFACO) (1996, as amended February 2008) as Storage Tanks and Miscellaneous Sites. CAU 121 consists of the following three Corrective Action Sites (CASs) located in Area 12 of the Nevada Test Site, which is approximately 65 miles northwest of Las Vegas, Nevada: (1) CAS 12-01-01, Aboveground Storage Tank; (2) CAS 12-01-02, Aboveground Storage Tank; and (3) CAS 12-22-26, Drums; 2 AST's. CAU 121 closure activities were conducted according to the FFACO and the Streamlined Approach for Environmental Restoration Plan for CAU 121 (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office, 2007). Field work took place from February through September 2008. Samples were collected to determine the path forward to close each site. Closure activities were completed as defined in the plan based on sample analytical results and site conditions. No contaminants of concern (COCs) were present at CAS 12-01-01; therefore, no further action was chosen as the corrective action alternative. As a best management practice (BMP), the empty aboveground storage tank (AST) was removed and disposed as sanitary waste. At CAS 12-01-02, polychlorinated biphenyls (PCBs) were present above the preliminary action level (PAL) in the soil beneath the AST that could possibly have originated from the AST contents. Therefore, PCBs were considered COCs, and the site was clean closed by excavating and disposing of soil containing PCBs. Approximately 5 cubic yards (yd{sup 3}) of soil were excavated and disposed as petroleum hydrocarbon PCB remediation waste, and approximately 13 yd3 of soil were excavated and disposed as PCB remediation waste. Cleanup samples were collected to confirm that the remaining soil did not contain PCBs above the PAL. Other compounds detected in the soil above PALs (i.e., total petroleum hydrocarbons [TPH] and semi-volatile organic compounds [SVOCs]) were determined to not likely have originated from the tank. Additional sample results showed that the compounds were likely present as a result of degraded asphalt around the adjacent, active water tank and not from the abandoned AST; therefore, they were not considered COCs. As a BMP, the empty AST was removed and disposed as sanitary waste. No COCs were present at CAS 12-22-26; therefore, no further action was chosen as the corrective action alternative. Although TPH was present at concentrations that exceeded the PAL, the volatile organic compound and SVOC hazardous constituents of TPH did not exceed the final action levels (FALs); therefore, TPH was not considered a COC. As a BMP, the empty AST was removed and disposed as sanitary waste. Closure activities generated sanitary waste, petroleum hydrocarbon PCB remediation waste, PCB remediation waste, and hazardous waste. Waste was appropriately managed and disposed. Waste that is currently staged on site is being appropriately managed and will be disposed under approved waste profiles in permitted landfills. Waste minimization activities included waste characterization sampling and segregation of waste streams.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Enriched Uranyl Nitrate in Nested Annular Tank Array

Two series of experiments were performed at the Rocky Flats Critical Mass Laboratory during the 1980s using highly enriched (93%) uranyl nitrate solution in annular tanks. [1, 2] Tanks were of typical sizes found in nuclear production plants. Experiments looked at tanks of varying radii in a co-located set of nested tanks, a 1 by 2 array, and a 1 by 3 array. The co-located set of tanks had been analyzed previously [3] as a benchmark for inclusion within the International Handbook of Evaluated Criticality Safety Benchmark Experiments. [4] The current study represents the benchmark analysis of the 1 by 3 array of a series of nested annular tanks. Of the seventeen configurations performed in this set of experiments, twelve were evaluated and nine were judged as acceptable benchmarks.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The simultaneous removal of technetium and iodine from Hanford tank waste

The simultaneous removal of radionuclides technetium-99 and iodine-129 from an actual decontaminated Hanford tank waste sample (a mixture of decontaminated waste from tanks 241-AP-105 and 241-AP-107) was demonstrated for the first time in this work. A series of commercially available ion exchange resins were evaluated in batch contact tests in the tank waste, and all showed removal of both Tc and I. The highest Tc removal was observed for Purolite A530e while the highest iodine removal was observed for ResinTech SIR-110-MP. Batch tests in simulated tank waste with these two resins showed that the SIR-110-HP-MP had consistently higher K d for both pertechnetate and iodide and much higher K d than previous works on Tc removal from Hanford waste. As such, the SIR-110-MP was evaluated in a dual -column (lead/lag) test processing 5.2L of the tank waste mixture showing 60% breakthrough of Tc on the lead column and no significant breakthrough on the lag after 625 bed volumes (BV, 6 mL size) while significant iodine breakthrough (>50%) occurred after 28 BV. The limited iodine uptake was attributed to the column conditions generating mass transfer limitations. A fraction of the Tc and I was not captured by the resin (<10%) in either the batch tests or column tests. The iodine fraction was identified to be an iodide, likely organo-iodide. The fraction of the Tc was identified as a non-pertechnetate species, which is the first time non-pertechnetate has been identified in AP-105 and AP-107 tanks, although the exact species is still unknown.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dehumidification energy storage using a stratified liquid desiccant tank

Liquid desiccants can play an important role in reducing dehumidification energy requirements in the built environment. Because they are in a liquid state, the desiccant can be easily stored and then used to dehumidify buildings during peak energy consumption periods. By maintaining stratification between concentrated and diluted desiccant solutions, a single tank can be used to store liquid desiccant for energy storage purposes. Using a stratified tank instead of separate tanks for dilute and concentrated solutions will reduce storage costs and increase energy storage densities for liquid desiccant systems. This paper describes the experimental validation and one-dimensional modeling of a stratified liquid desiccant tank. The stratified tank prototype developed achieved 80 % of the theoretical energy storage density based on an imposed desiccant concentration change. Here, the stratified tank model was able to reasonably reproduce the experimental results. Using this model, the impact of varying operational conditions on the energy density of the stratified liquid desiccant energy storage was evaluated. Depending on the operating conditions, stratified liquid desiccant energy storage using aqueous LiCl up to 40 wt% can achieve energy storage densities in excess of 330 kWh/m 3 .

25 ENERGY STORAGE↗

Analytical Solutions for Seismic Fluid-Structure Interaction of Head-Supported Cylindrical Tanks

Fluid-structure interaction (FSI) of earthquake shaking is a design consideration in the civil, nuclear, chemical, and mechanical industries. Preliminary sizing of structures and components in these industries will often use analytical solutions because there is insufficient information to warrant the analysis of numerical models. Here, this study extends prior analytical work on seismic FSI of base-supported tanks in the 1980s to accommodate head-supported tanks with geometries similar to those proposed for new-build, liquid (fluid)-filled, advanced reactors. Analytical solutions are derived for flexible, head-supported, cylindrical tanks subjected to small-amplitude, unidirectional, horizontal seismic motion, and address frequencies of lateral motions of the tank, hydrodynamic pressures, frequencies of waves, wave heights, and reactions at the head support. Solutions are presented for a range of tank dimensions and could be used for a) preliminary design of head-supported cylindrical tanks and their supporting structures with idealized seismic input, and b) verification of numerical models to be used for final seismic analysis, design, and probabilistic risk assessment.

42 ENGINEERING↗

PROBABILITY BASED CORROSION CONTROL FOR WASTE TANKS - PART II

As part of an ongoing study to evaluate the discontinuity in the corrosion controls at the SRS tank farm, a study was conducted this year to assess the minimum concentrations below 1 molar nitrate, see Figure 1. Current controls on the tank farm solution chemistry are in place to prevent the initiation and propagation of pitting and stress corrosion cracking in the primary steel waste tanks. The controls are based upon a series of experiments performed with simulated solutions on materials used for construction of the tanks, namely ASTM A537 carbon steel (A537). During FY09, an experimental program was undertaken to investigate the risk associated with reducing the minimum molar nitrite concentration required to confidently inhibit pitting in dilute solutions (i.e., less than 1 molar nitrate). The experimental results and conclusions herein provide a statistical basis to quantify the probability of pitting for the tank wall exposed to various solutions with dilute concentrations of nitrate and nitrite. Understanding the probability for pitting will allow the facility to make tank-specific risk-based decisions for chemistry control. Based on previous electrochemical testing, a statistical test matrix was developed to refine and solidify the application of the statistical mixture/amount model to corrosion of A537 steel. A mixture/amount model was identified based on statistical analysis of recent and historically collected electrochemical data. This model provides a more complex relationship between the nitrate and nitrite concentrations and the probability of pitting than is represented by the model underlying the current chemistry control program, and its use may provide a technical basis for the utilization of less nitrite to inhibit pitting at concentrations below 1 molar nitrate. FY09 results fit within the mixture/amount model, and further refine the nitrate regime in which the model is applicable. The combination of visual observations and cyclic potentiodynamic polarization scans indicates a potential for significant inhibitor reductions at nitrate concentrations near 1.0 M without a significant increase in corrosion risk. The complete data sets from FY08 and FY09 testing have determined the statistical basis to confidently inhibit against pitting using nitrite inhibition with the current pH controls. Future testing will complete the spectrum of nitrate concentrations around 1 molar. These results will be combined to provide a complete spectrum for corrosion controls with a risk based component.

36 MATERIALS SCIENCE↗

ANALYSIS OF SAMPLES FROM TANK 5F CHEMICAL CLEANING

The Savannah River Site (SRS) is preparing Tank 5F for closure. The first step in preparing the tank for closure is mechanical sludge removal. Following mechanical sludge removal, SRS performed chemical cleaning with oxalic acid to remove the sludge heel. Personnel are currently assessing the effectiveness of the chemical cleaning. SRS personnel collected liquid samples during chemical cleaning and submitted them to Savannah River National Laboratory (SRNL) for analysis. Following chemical cleaning, they collected a solid sample (also known as 'process sample') and submitted it to SRNL for analysis. The authors analyzed these samples to assess the effectiveness of the chemical cleaning process. The conclusions from this work are: (1) With the exception of iron, the dissolution of sludge components from Tank 5F agreed with results from the actual waste demonstration performed in 2007. The fraction of iron removed from Tank 5F by chemical cleaning was significantly less than the fraction removed in the SRNL demonstrations. The likely cause of this difference is the high pH following the first oxalic acid strike. (2) Most of the sludge mass remaining in the tank is iron and nickel. (3) The remaining sludge contains approximately 26 kg of barium, 37 kg of chromium, and 37 kg of mercury. (4) Most of the radioactivity remaining in the residual material is beta emitters and {sup 90}Sr. (5) The chemical cleaning removed more than {approx} 90% of the uranium isotopes and {sup 137}Cs. (6) The chemical cleaning removed {approx} 70% of the neptunium, {approx} 83% of the {sup 90}Sr, and {approx} 21% of the {sup 60}Co. (7) The chemical cleaning removed less than 10% of the plutonium, americium, and curium isotopes. (8) The chemical cleaning removed more than 90% of the aluminium, calcium, and sodium from the tank. (9) The cleaning operations removed 61% of lithium, 88% of non-radioactive strontium, and 65% of zirconium. The {sup 90}Sr and non-radioactive strontium were measured by different methods, and the differences in the fraction removed are not statistically significant. (10) Chemical cleaning removed 10-50% of the barium, chromium, iron, magnesium, manganese, and silicon. (11) Chemical cleaning removed only {approx}1% of the nickel.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SUMMARY PLAN FOR BENCH-SCALE REFORMER AND PRODUCT TESTING TREATABILITY STUDIES USING HANFORD TANK WASTE

This paper describes the sample selection, sample preparation, environmental, and regulatory considerations for shipment of Hanford radioactive waste samples for treatability studies of the FBSR process at the Savannah River National Laboratory and the Pacific Northwest National Laboratory. The U.S. Department of Energy (DOE) Hanford tank farms contain approximately 57 million gallons of wastes, most of which originated during the reprocessing of spent nuclear fuel to produce plutonium for defense purposes. DOE intends to pre-treat the tank waste to separate the waste into a high level fraction, that will be vitrified and disposed of in a national repository as high-level waste (HLW), and a low-activity waste (LAW) fraction that will be immobilized for on-site disposal at Hanford. The Hanford Waste Treatment and Immobilization Plant (WTP) is the focal point for the treatment of Hanford tank waste. However, the WTP lacks the capacity to process all of the LAW within the regulatory required timeframe. Consequently, a supplemental LAW immobilization process will be required to immobilize the remainder of the LAW. One promising supplemental technology is Fluidized Bed Steam Reforming (FBSR) to produce a sodium-alumino-silicate (NAS) waste form. The NAS waste form is primarily composed of nepheline (NaAlSiO{sub 4}), sodalite (Nas[AlSiO{sub 4}]{sub 6}Cl{sub 2}), and nosean (Na{sub 8}[AlSiO{sub 4}]{sub 6}SO{sub 4}). Semivolatile anions such as pertechnetate (TcO{sub 4}{sup -}) and volatiles such as iodine as iodide (I{sup -}) are expected to be entrapped within the mineral structures, thereby immobilizing them (Janzen 2008). Results from preliminary performance tests using surrogates, suggests that the release of semivolatile radionuclides {sup 99}Tc and volatile {sup 129}I from granular NAS waste form is limited by Nosean solubility. The predicted release of {sup 99}Tc from the NAS waste form at a 100 meters down gradient well from the Integrated Disposal Facility (IDF) was found to be comparable to immobilized low-activity waste glass waste form in the initial supplemental LAW treatment technology risk assessment (Mann 2003). To confirm this hypothesis, DOE is funding a treatability study where three actual Hanford tank waste samples (containing both {sup 99}Tc and {sup 125}I) will be processed in Savannah River National Laboratory's (SRNL) Bench-Scale Reformer (BSR) to form the mineral product, similar to the granular NAS waste form, that will then be subject to a number of waste form qualification tests. In previous tests, SRNL have demonstrated that the BSR product is chemically and physically equivalent to the FBSR product (Janzen 2005). The objective of this paper is to describe the sample selection, sample preparation, and environmental and regulatory considerations for treatability studies of the FBSR process using Hanford tank waste samples at the SNRL. The SNRL will process samples in its BSR. These samples will be decontaminated in the 222-S Laboratory to remove undissolved solids and selected radioisotopes to comply with Department of Transportation (DOT) shipping regulations and to ensure worker safety by limiting radiation exposure to As Low As Reasonably Achievable (ALARA). These decontamination levels will also meet the Nuclear Regulatory Commission's (NRC's) definition of low activity waste (LAW). After the SNRL has processed the tank samples to a granular mineral form, SRNL and Pacific Northwest National Laboratory (PNNL) will conduct waste form testing on both the granular material and monoliths prepared from the granular material. The tests being performed are outlined in Appendix A.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of the Tank 5F Feed and Bleed Residual Solids

Savannah River Remediation (SRR) is preparing Tank 5F for closure. As part of Tank 5F Closure Mechanical Cleaning, SRR conducted a 'Feed and Bleed' process in Tank 5F. Following this 'Feed and Bleed' Mechanical Cleaning in Tank 5F, SRR collected two tank heel samples (referred to as sample 1 and sample 2) under Riser 5 to determine the composition of the material remaining in the tanks. This document describes sample analysis results. The conclusions from this analysis follow. (1) The anions measured all had a concentration less than 250 mg/kg, except for oxalate, which had a concentration of 2100-2400 mg/kg. (2) The measured cations with the highest concentration were iron (432,000-519,000 mg/kg), nickel (54,600-69,300 mg/kg), and manganese (35,200-42,100 mg/kg). All other cations measured less than 13,000 mg/kg. (3) The radionuclides present in the highest concentration are {sup 90}Sr (3.0 x 10{sup 10} dpm/g), {sup 137}Cs (6.8 x 10{sup 8} dpm/g), and {sup 241}Am (1.4 x 10{sup 8} - 1.8 x 10{sup 8} dpm/g). (4) The particle size analysis shows a large fraction of particles greater than 100 {micro}.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental and Modeling Study of the Flammability of Fuel Tank Headspace Vapors from Ethanol/Gasoline Fuels; Phase 3: Effects of Winter Gasoline Volatility and Ethanol Content on Blend Flammability; Flammability Limits of Denatured Ethanol

This study assessed differences in headspace flammability for summertime gasolines and new high-ethanol content fuel blends. The results apply to vehicle fuel tanks and underground storage tanks. Ambient temperature and fuel formulation effects on headspace vapor flammability of ethanol/gasoline blends were evaluated. Depending on the degree of tank filling, fuel type, and ambient temperature,fuel vapors in a tank can be flammable or non-flammable. Pure gasoline vapors in tanks generally are too rich to be flammable unless ambient temperatures are extremely low. High percentages of ethanol blended with gasoline can be less volatile than pure gasoline and can produce flammable headspace vapors at common ambient temperatures. The study supports refinements of fuel ethanol volatilityspecifications and shows potential consequences of using noncompliant fuels. E85 is flammable at low temperatures; denatured ethanol is flammable at warmer temperatures. If both are stored at the same location, one or both of the tanks' headspace vapors will be flammable over a wide range of ambient temperatures. This is relevant to allowing consumers to splash -blend ethanol and gasoline atfueling stations. Fuels compliant with ASTM volatility specifications are relatively safe, but the E85 samples tested indicate that some ethanol fuels may produce flammable vapors.

02 PETROLEUM↗