Advanced District Energy Controls for Improved Efficiency and Resilience
District energy systems efficiently provide thermal energy to multiple buildings and facilities through a network of shared infrastructure.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
District energy systems efficiently provide thermal energy to multiple buildings and facilities through a network of shared infrastructure.
The Idaho National Laboratory (INL) resilience framework has been developed to broadly apply to EEDS so that all elements of systems that contain distributed wind can be part of the resilience evaluation. The users or audience for this framework can include any stakeholders associated with the EEDS. Not all electrical energy systems have the same stakeholders; customers, owners, and operators are generally present but have different interests. Considering the broad electrical grid, customers, regulators, investors, utility planners, engineers, and operators each have an interest in system resilience driven from different motivating factors. This document focuses on the planning stage of the framework. In this document, each step is explained briefly before demonstrating its application to the St. Mary’s-Mt. Village system. The framework can be used for many types of resilience planning. It can be used to evaluate current overall resilience, or the resilience of certain subsystems. It can be used to explore existing resilience weak points and propose mitigations. It can also be used to evaluate the resilience benefits of a new investment. We use the latter application for this case study. Although the wind turbine in St. Mary’s has already been installed, the resilience benefits that the turbine provided were not well defined. It was installed with the main objective to generate electric power from a renewable resource in an effort to reduce the local dependency on fuel oil as the sole source of electric power generation, which is a resilience goal on its own, but there are other ways in which the turbine can add resilience to the system, as well as scenarios of interest to analyze how resilient the wind turbine itself is against different hazards. In this case study, we analyze the operation of the St. Mary’s power system both with the wind installed and without the wind installed during different resilience hazards of interest. This allows us to compare the performance with wind and without wind and to quantify the resilience benefits provided by wind. Our MIRACL partners at PNNL will then take the resilience benefits and assign value to the resilience provided by wind based on costs and costs avoided in the different scenarios.
The use of stationary electrochemical energy storage systems utilizing lithium-ion batteries has increased rapidly as the production scale and price for lithium-ion batteries has decreased. These energy storage systems are crucial for maintaining grid resiliency, especially for grids operating with high penetration of renewable energy generation assets or for with a variety of distributed energy generation and storage systems. One challenging factor for the development of battery energy storage systems is estimating the proper sizing, in terms of both power and energy, that minimizes total costs over the lifetime of the systems; this calculation is difficult in simple cases, where a battery is costed independently, but is extremely challenging when building loads and electrical generation by photovoltaic resources are also considered. REopt is a techoeconomic optimization tool developed by NREL to address these challenges. Previously, battery degradation has been priced by simply assuming a 10-year replacement schedule for battery systems. However, this does not account for varying degradation trends observed across real-world batteries, or allow for batteries to be operated in a degradation-aware manner that optimizes battery dispatch based on operating costs. This work incorporates a battery life model into REopt. This battery life model is simple, so that it may be solvable within the constrains of a mixed-integer linear optimization problem, but is fit to accelerated aging data recorded in the lab. To achieve the best possible accuracy for lifetime estimates given these constraints, parameters for the battery life model in REopt are estimated by fitting 20-year simulations of battery life after identifying state-space battery degradation model from accelerated aging data. Comparisons of battery life predicted in REopt and from the state-space battery degradation model to ensure validity of lifetime estimates made by REopt. Battery life and cost is optimized by controlling three decision to minimize system life cost: battery sizing, daily state-of-charge, and daily energy-throughput. The cost of battery degradation as a function of these control variables is then estimated assuming two possible maintenance strategies: replacement, where the entire battery system is replaced if cell reach an end-of-life capacity threshold; and augmentation, which establishes a fund to pay for continual purchase of new batteries to maintain the initial energy capacity of the system. These two strategies offer conservative (for replacement) and optimistic (for augmentation) bounds for total system cost. The degradation cost incurred by these strategies is then used to control battery dispatch decisions, operating the battery in a degradation-aware manner that maximizes battery lifetime while also providing energy when favorable. Because the mixed-integer linear program has perfect foresight of future energy needs, batteries with degradation costs are always operated using 'just-in-time' charging, which is unrealistic, as no energy is left in the storage system to perform other energy services or to serve as emergency back-up power. To combat this, an inequality constraint on the average annual state-of-charge is imposed, and the sensitivity of system cost to average stored energy, e.g., the cost of system resiliency, can be quantified. Analysis of results has several conclusions, for instance, oversizing of battery storage systems is not a cost burden when battery storage is an optimal solution, as any additional battery capacity can simply be utilized to avoid costs of purchasing energy from a utility.
The success of a future clean hydrogen infrastructure will depend on technology performance, operating conditions, and system configuration, which will be integrated to meet specific end-use requirements. We introduce a Systems-to-Atoms framework to cosimulate material, device, and system design for clean hydrogen storage and transport. Here we present a demonstration scenario in which hydrogen is distributed using a liquid organic hydrogen carrier to 700 bar refueling stations. Cross-scale analysis on hydrogen release at the refueling station reveals that while a high reaction pressure (up to 100 bar) may not enhance the catalyst performance, it can lead to system-level cost savings (up to 5% of total refueling station cost) due to savings in downstream gas compression. Further, a typically low-performing dehydrogenation catalyst material (e.g., copper) may be preferred over a high-performing catalyst (e.g., palladium) at different operating conditions when considering overall system affordability and supply chain resilience.
This report documents an energy system planning study for the village of Ouzinkie, Alaska, conducted by the U.S. Department of Energy's (DOE) Energy Transitions Initiative Partnership Project (ETIPP). Ouzinkie is a small remote community located on Spruce Island, Alaska, in the Kodiak Archipelago. The Ouzinkie community is served by a local electrical system powered by a combination of diesel generators and a hydroelectric turbine. Due to aging assets, however, the power system reliability has declined in recent years, while the cost of operating the diesel generators has increased significantly. To address these problems, Ouzinkie asked ETIPP to provide technical assistance to develop an updated integrated plan for improvements to the Ouzinkie power system, in order to transition to a more reliable and resilient system powered by renewable energy resources.
Abstract Behind the meter rooftop solar plus storage (PVESS) has the potential to benefit the hosting customers by providing affordability, environmental, and reliability and resilience value. Whereas the bill reduction and environmental benefits of PVESS are well studied, its monetary resilience benefits are less understood. The increasing trend of power interruptions driven by extreme weather events heightens the need to understand these benefits. This study leverages various publicly available datasets to perform a cost benefit analysis of adding to determine the resilience value of PVESS for a typical single family home in each county in the continental U.S. We find that PVESS is very effective to technically mitigate interruptions across the country. However, the monetary benefits in the base case only cover about 14% of battery costs, with no county exceeding 60%. This is somewhat expected, given that PVESS provide other monetary benefits that are not part of this analysis. Through sensitivities, we find that higher frequency of extreme weather events roughly triples the resilience value of PVESS and that higher values of lost load double the same metric. Our sensitivity analysis shows that the benefit cost ratio of PVESS for customers living in areas with higher-than-average frequency of long duration interruptions and value of lost load is already above one even without considering other value streams. We conclude with recommendations that regulators and utilities could implement to enable customers to calculate and capture the resilience value of PVESS more efficiently.
Transient stability assessment (TSA) is a cornerstone for resilient operations of todays interconnected power grids. This paper is a confluence of quantum computing, data science and machine learning to potentially address the power system TSA issue. Here, we devise a quantum TSA (QTSA) method to enable scalable and efficient data-driven transient stability prediction for bulk power systems, which is the first attempt to tackle the TSA issue with quantum computing. Our contributions are three-fold: 1) A high expressibility, low-depth (HELD) quantum circuit is designed for accurate and noise-resilient TSA; 2) A quantum natural gradient descent algorithm is developed for efficient HELD circuit training; 3) A systematical analysis on QTSAs performance under various quantum factors is per-formed. QTSA underpins a foundation of quantum-enabled and data-driven power grid stability analytics. It renders the intractable TSA straightforward and effortless in the Hilbert space, and therefore provides stability information for power system operations. Extensive experiments on quantum simulators and real quantum computers verify the accuracy, noise-resilience, scalability and universality of QTSA.
We report a distribution service restoration algorithm as a fundamental resilient paradigm for system operators provides an optimally coordinated, resilient solution to enhance the restoration performance. The restoration problem is formulated to coordinate distribution generators and controllable switches optimally. A model-based control scheme is usually designed to solve this problem, relying on a precise model and resulting in low scalability. To tackle these limitations, this work proposes a graph-reinforcement learning framework for the restoration problem. We link the power system topology with a graph convolutional network, which captures the complex mechanism of network restoration in power networks and understands the mutual interactions among controllable devices. Latent features over graphical power networks produced by graph convolutional layers are exploited to learn the control policy for network restoration using deep reinforcement learning. The solution scalability is guaranteed by modeling distributed generators as agents in a multi-agent environment and a proper pre-training paradigm. Comparative studies on IEEE 123-node and 8500-node test systems demonstrate the performance of the proposed solution.
Energy poverty, defined as a lack of access to reliable electricity and reliance on traditional biomass resources for cooking, affects over a billion people daily. The World Health Organization estimates that household air pollution from inefficient stoves causes more premature deaths than malaria, tuberculosis, and HIV/AIDS. Increasing demand for energy has led to dramatic increases in emissions. The need for reliable electricity and limiting emissions drives research on Resilient Hybrid Energy Systems (RHESs), which provide cleaner energy through combining wind, solar, and biomass energy with traditional fossil energy, increasing production efficiency and reliability and reducing generating costs and emissions. Microgrids have been shown as an efficient means of implementing RHESs, with some focused mainly on reducing the environmental impact of electric power generation. The technical challenges of designing, implementing, and applying microgrids involve conducting a cradle-to-grave Life Cycle Analysis (LCA) to evaluate these systems’ environmental and economic performance under diverse operating conditions to evaluate resiliency. A sample RHES was developed and used to demonstrate the implementation in rural applications, where the system can provide reliable electricity for heating, cooling, lighting, and pumping clean water. The model and findings can be utilized by other regions around the globe facing similar challenges.
Active distribution system resources have the potential to support the bulk power system (BPS) during abnormal conditions, increasing reliability and resilience of power systems and end-use customers. This paper investigates for the first time the BPS voltage support provided by networked microgrids at the feeder level. A peer-to-peer (P2P) communication control framework is introduced to enable the coordination of multiple microgrids in a mixed ownership environment. This allows the microgrids to run a consensus algorithm (CA) to distributedly determine their own reactive power injections. Thus, the reactive power injection contribution is realized in a fair manner by having the same ratio of reactive power injection to the reactive power headroom for all microgrids. The CA implementation and performance within the P2P network framework are demonstrated on the IEEE 39-bus testcase system with 10 microgrids part of the distribution feeder assumed to be connected to one of the BPS buses.
Society and modern life are dependent on critical infrastructure that is composed of expensive, special purpose devices that have long life cycles and may be in use for decades before being replaced. There are an abundance of organizations and individuals doing vulnerability analysis on a variety of systems, but what makes the Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program unique and valuable is its strategic focus on high-priority critical infrastructure, close partnership with vendors, and ability to leverage bills of materials (BOMs) to identify and relate vulnerabilities to affected systems. Creating a bill of materials is a formal way of understanding and documenting the components of a system, including everything from integrated circuits to operating systems to third-party libraries. This is beneficial for connecting known vulnerabilities to affected devices, since vulnerabilities in a specific component are often not mapped to all systems that use that vulnerable component. Additionally, CyTRICS finds novel vulnerabilities through its vulnerability testing process and works closely with vendor partners to provide vulnerability reports so that affected systems can be patched in a timely manner. This presentation will describe the interrelated technical processes CyTRICS uses to create bills of materials and conduct vulnerability analysis.
INL, PNNL, and NREL, with support from our academic and industry partners, hosted a 2-day webinar to learn more about the benefits of hybrid energy systems, considerations for designing the right system for communities, and practical tools that can help with the design and development process. In Day 1 of this webinar, the focus was on why users might want to consider hybrid energy systems, and frameworks that could help inform design decisions for hybrid systems, including a valuation framework, resilience framework, and hybrid system design optimization framework.
In this paper, we present the capabilities of the CLAIRE System which provides resilient communications for NASA in presence of interference and congestion for a heterogeneous multi-vendor network. CLAIRE increases mission science data return to improve resource efficiencies and ensures resilience in the unpredictable space environment for NASA missions and communication networks. CLAIRE provides technology / waveform agnostic cognitive control plane that is instantiated at the Application Layer (APP) so that it can ride on NASA’s HDTN bundle protocol or any other protocol stack that is used by the network. The cognitive control plane is instantiated using Heartbeats (HTBTs). CLAIRE is assisted by Wideband UHF-Ka Band RF Sensing that leverages advances in the Direct Digital Transceiver (DDTRX) technology. The Wideband RF Sensing is driven by statistical signal processing and machine learning algorithms. Interference is mitigated using Dynamic Spectrum Access (DSA). Finally, CLAIRE addresses congestion using spectrum aware packet forwarding algorithm. CLAIRE provides an extensible protocol that allows passing of RF spectrum situational awareness, cross-layer sensing, delay tolerant networking and dynamic spectrum access information that can help with network optimization. Cross-Layer Sensing (CLS) and CLAIRE Decision Engine (CDE) enable spectrum and delay aware packet forwarding and Dynamic Spectrum Access during cases of severe interference.
Resilience curves track the accumulation and restoration of outages during an event on an electric distribution grid. We show that a resilience curve generated from utility data can always be decomposed into an outage process and a restore process and that these processes generally overlap in time. We use many events in real utility data to characterize the statistics of these processes, and derive formulas based on these statistics for resilience metrics such as restore duration, customer hours not served, and outage and restore rates. The formulas express the mean value of these metrics as a function of the number of outages in the event. We also give a formula for the variability of restore duration, which allows us to predict a maximum restore duration with 95% confidence. Overall, we give a simple and general way to decompose resilience curves into outage and restore processes and then show how to use these processes to extract resilience metrics from standard distribution system data.
Rapid advances in artificial intelligence are enabling automated systems to operate in an increasingly autonomous manner in domains that previously required the involvement of human operators. Examples are rail transport systems, self-driving cars, and warehouse delivery systems. From time to time, such automation encounters operational conditions that fall outside a “competency box” within which the system has been designed to operate. Human operators add resilience because they can see and act outside the competency box of scenarios and environments for which the system was designed. The system’s competencies can be expanded over time with modifications to software, sensors, etc.; however, it is unclear at what point the competency box becomes large enough to safely eliminate the role of the human operator. One area where advanced automation may be applied is Urban Air Mobility (UAM). Current UAM concepts envision fleets of highly automated air vehicles providing on-demand transport for people and goods. A phased development of UAM has been proposed, beginning with on-board pilots and transitioning to a future state where automated vehicles operate with minimal human involvement. Proponents of UAM note that this final state reduces cost as well as eliminating pilot error, identified as a contributing factor in many aircraft accidents. However, eliminating human involvement also risks eliminating their positive contributions to system resilience. Here we examine Concepts of Operation proposed for future UAM systems and explore how humans can best be incorporated to maintain resilience while minimizing cost and risk. A human-autonomy teaming approach is suggested.
Across recent years, there has been a growing prevalence of extreme weather events throughout the United States, posing significant challenges to the reliable and resilient operation of power systems. Specifically, summer droughts threaten to severely reduce available generation capacity to meet regional electricity demand, potentially leading to power outages. This underscores the importance of accurate resource adequacy (RA) assessment to ensure the reliable operation of the nation’s energy infrastructure. Accurately evaluating the usable capacity of regional generation fleets is a challenging undertaking due to the intricate interactions between power systems and hydro-climatic systems. Here, this paper proposes a systematic and analytical framework to evaluate the impacts of extreme summer drought events on the available capacity of various generating technologies, incorporating both meteorological and hydrologic factors. The framework provides detailed plant-level capacity derating models for hydroelectric, thermoelectric, and renewable power plants, facilitating evaluations with high temporal and spatial resolution. The application of the proposed impact assessment framework to the 2025 generation fleet of the real-world power system within the PJM and SERC regions of the United States yields insightful results. By analyzing the daily usable capacity of 6,055 at-risk generators across the study region, it shows that the summer capacity deration is most significant for hydroelectric and once-through thermal power plants, followed by recirculating thermal power plants and combustion turbines. In the event of the recurrence of the 2007 southeastern summer drought event in the near future, the generation fleet could experience a substantial reduction in available capacity, estimated at approximately 8.5 GW, compared to typical summer conditions. The sensitivity analysis reveals that the usable capacity of the generation fleet would suffer an even more significant decrease under conditions of increasingly severe summer droughts. The proposed approach and the findings of this study provide valuable methodologies and insights, empowering stakeholders to bolster the resilience of power systems against the potentially devastating effects of future extreme drought events.
Accurate and speedy detection of power system events is critical to enhancing the reliability and resiliency of power systems. Although supervised deep learning algorithms show great promise in identifying power system events, they require a large volume of high-quality event labels for training. This paper develops a bidirectional anomaly generative adversarial network (GAN)-based algorithm to detect power system events using streaming PMU data, which does not rely on a huge amount of event labels. By introducing conditional entropy constraint in the objective function of GAN and graph signal processing-based PMU sorting technique, our proposed algorithm significantly outperforms state-of-the-art event detection algorithms in terms of accuracy. To facilitate the adoption of the proposed algorithm, a prototype online platform is also developed using Apache Hadoop, Kafka, and Spark to enable real-time event detection. Here, the accuracy and computational efficiency of the proposed algorithm are validated using a large-scale real-world PMU dataset from the Eastern Interconnection of the United States.
The vision of the ‘Smart Grid’ anticipates a distributed real-time embedded system that implements various monitoring and control functions. As the reliability of the power grid is critical to modern society, the software supporting the grid must support fault tolerance and resilience of the resulting cyber-physical system. This paper describes the fault-tolerance features of a software framework called Resilient Information Architecture Platform for Smart Grid (RIAPS). The framework supports various mechanisms for fault detection and mitigation and works in concert with the applications that implement the grid-specific functions. The paper discusses the design philosophy for and the implementation of the fault tolerance features and presents an application example to show how it can be used to build highly resilient systems.