Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Synchronization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Pioneer Design of Non-contact Synchronized Measurement Devices Using Electric and Magnetic Field Sensors

Here, traditional synchrophasors rely on CTs and PTs physically connected to transmission lines or buses to acquire input signals for phasor measurement. However, it is challenging to install and maintain traditional phasor measurement units in some remote areas due to lack of facilities. Since transmission lines naturally generate alternating electrical and magnetic fields in the surrounding atmosphere, this paper presents two innovative designs for non-contact synchronized measurement devices (NCSMD), including an electric field sensor based non-contact SMD (E-NCSMD) and a magnetic field sensor based non-contact SMD (M-NCSMD). Compared with conventional synchrophasors, E-NCSMD and M-NCSMD are much more flexible to be deployed and have much lower costs, making E-NCSMDs and M-NCSMD highly accessible and useful for a wide array of phasor measurement applications. Laboratory and field experiment results verified the effectiveness of the designs of both E-NCSMD and M-NCSMD.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimization of Air-Gap Profile in Interior Permanent-Magnet Synchronous Motors for Torque Ripple Mitigation

Interior permanent magnet synchronous motors (IPMSMs) have been widely used due to their high efficiency and high power density. Minimization of torque pulsation resulting in vibration and acoustic noise is one of the important design considerations for IPMSMs. In this paper, a grid on/off search method for the rotor profile is proposed to mitigate torque pulsation. Selection of the rotor profile is due to the fact that air-gap is the most sensitive parameter in electric machines wherein changes in flux densities can cause substantial differences in the distribution of forces. A layer comprised of 20 partitions with a 0.1 mm thickness and 3 degrees wide grids have been introduced to the rotor surface for each pole and the possible geometries have been analyzed using finite element method (FEM) in ANSYS Maxwell. An optimal design was found that has the lowest torque ripple with a higher average torque compared to the original design. Genetic algorithm (GA) has also been applied to the method to automate the coupling between Maxwell and Matlab thereby saving the simulation time. Finally, complete structural analysis has been done for both of the original and optimal designs to verify the superiority and feasibility of the proposed design.

42 ENGINEERING↗

On the role of flexoeffect in synchronization of electroconvective roll oscillations in nematics

We describe the dynamics of zigzag oscillations in a system of convective rolls in a nematic liquid crystal above the electroconvection threshold under the action of an ac voltage with a biased position of the mean value. It is found that an increase in the contribution from the constant component leads to a substantial increase in the spatiotemporal ordering of zigzag rolls and their synchronization with the homogeneous twist mode. The results confirm the flexoelectric mechanism of locking.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Intermittency at the Boundary of Generalized Synchronization in Mutually Coupled Systems with Complex Attractor Topology

The mechanisms of occurrence and characteristics of intermittency at the boundary of generalized synchronization in mutually coupled systems with complex (two-sheet) chaotic attractor topology are investigated. It has been established that the occurrence of intermittency in this case is due to the imaging point jump from one sheet of the chaotic attractor to another. At the same time, distributions of laminar phase durations and dependences of average laminar phase durations on the supercriticality parameter obey exponential laws.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Establishment of a Chaotic Synchronous Response in the Presence of a Phase Filter in a Communication Channel

The problem of establishment of a chaotic synchronous response between two chaotic self-sustained oscillator systems under the conditions of phase filtration of the chaotic signal transferred via a channel from the master to slave system is considered. The characteristics of the phase filter are equivalent to those of a filter present in a communication channel with multipath propagation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Diagnostic Technique for Generalized Synchronization in Systems with a Complex Chaotic Attractor Topology

A diagnostic technique is proposed for the mode of generalized synchronization in systems with a complex chaotic attractor topology based on consideration of tubes of trajectories in the phase space of interacting systems. The method functionality is tested by the numerical simulation of two mutually coupled modified Lorentz systems: one in the chaotic state, and another in the hyperchaotic state. The results are compared to the data obtained by calculating the Lyapunov exponent spectrum and show good agreement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Virtual Synchronous Machine Grid-Forming Inverter Model Specification (REGFM_B1)

This report describes a generic virtual synchronous machine (VSM) grid-forming inverter (GFM) model - REGFM_B1. The initial model specification was proposed by Pacific Northwest National Laboratory (PNNL), General Electric (GE), and Electric Power Research Institute (EPRI). Siemens Gamesa Renewable Energy (SGRE) also provided inputs to the specification. The model specification has been revised multiple times based on the discussions between all the contributors listed in this report. This work was funded by the Universal Interoperability for Grid-Forming Inverters (UNIFI) Consortium. This generic model is developed to help the utility industry understand the concept of VSM GFMs. The model could be used to represent equipment for long-term planning studies where vendor-specific models are not available. As equipment mature and improve, generic models will be updated to capture the new functionalities of GFMs. It is not intended that these models will always remain representative of all future GFM technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Recent Advances in Precision Clock Synchronization Protocols for Power Grid Control Systems

With the advent of a new Precision Time Protocol specification, new opportunities abound for clock synchronization possibilities within power grid control systems. The third iteration of the Institute of Electrical and Electronics Engineers Standard 1588 specification provides several new features specifically aimed at complex, wide-area deployments in which situational awareness and control require precise time agreement. This paper describes the challenges faced by existing technology, introduces the new time distribution specification, and provides examples to explain how it represents a game-changing innovation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigation on Tuning Power–Frequency Droop for Improved Grid–Forming Inverter and Synchronous Generator Transient Load Sharing

Poor transient load sharing has been observed during the parallel operation of synchronous generators (SGs) and droop-controlled grid-forming (GFM) inverter-based resources (IBRs) in islanded microgrids. This can result in overcurrent protections, causing the inverters to trip, which leads to the collapse of voltage and frequency. In this article, small-signal analysis supported by electromagnetic transients (EMTs) simulation is performed on a detailed model of a microgrid containing IBRs and an SG to identify underdamped modes and their sensitivities to the power–frequency (P-F) droop parameter. Further EMT simulation of a more complex microgrid model with multiple GFM IBRs and SGs is performed to determine whether trends identified from the modal analysis extend to cases where the number of SGs in operation may vary. The objective is to investigate the effectiveness of tuning this parameter to reduce the likelihood of overcurrents in response to load and generation disturbances. The work uncovers both fast and slow modes of concern. Primarily, the findings show that increasing the P-F droop value improves the damping of the slower mode while degrading the damping of the faster mode, leading to an upper limit on the damping improvement of the GFM IBR output current. In EMT simulations of the more complex microgrid, the greatest damping improvement still exhibits significant maximum overshoot. Furthermore, the optimal value of the P-F droop parameter is sensitive to the number of SGs in operation. The conclusion is that tuning the P-F droop parameter is not an effective means to avoid the overcurrent tripping of GFM IBRs during response to large load or generation disturbances when operating in parallel to SGs in islanded microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamically Reconfigurable Data Readout of Pixel Detectors for Automatic Synchronization with Data Acquisition Systems

Reconfigurable detectors with dynamically selectable sensing and readout modes are highly desirable for implementing edge computing as well as enabling advanced imaging techniques such as foveation. The concept of a camera system capable of simultaneous passive imaging and dynamic ranging in different regions of the detector is presented. Such an adaptive-autonomous detector with both spatial and temporal control requires programmable window of exposure (time frames), ability to switch between readout modes such as full-frame imaging and zero-suppressed data, modification of the number of pixel data bits and independent programmability for distinct detector regions. In this work, a method is presented for seamlessly changing time frames and readout modes without data corruption while still ensuring that the data acquisition system (DAQ) does not need to stop and resynchronize at each change of setting, thus avoiding significant dead time. Data throughput is maximized by using a minimum unique data format, rather than lengthy frame headers, to differentiate between consecutive frames. A data control and transmitter (DCT) synchronizes data transfer from the pixel to the periphery, reconfigures the data to transmit it serially off-chip, while providing optimized decision support based on a DAQ definable mode. Measurements on a test structure demonstrate that the DCT can operate at 1 GHz in a 65 nm LP CMOS process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data-driven Optimal Control Strategy for Virtual Synchronous Generator via Deep Reinforcement Learning Approach

This paper aims at developing a data-driven optimal control strategy for virtual synchronous generator (VSG) in the scenario where no expert knowledge or requirement for system model is available. Firstly, the optimal and adaptive control problem for VSG is transformed into a reinforcement learning task. Specifically, the control variables, i.e., virtual inertia and damping factor, are defined as the actions. Meanwhile, the active power output, angular frequency and its derivative are considered as the observations. Moreover, the reward mechanism is designed based on three preset characteristic functions to quantify the control targets: (1) maintaining the deviation of angular frequency within special limits; (2) preserving well-damped oscillations for both the angular frequency and active power output; (3) obtaining slow frequency drop in the transient process. Next, to maximize the cumulative rewards, a decentralized deep policy gradient algorithm, which features model-free and faster convergence, is developed and employed to find the optimal control policy. With this effort, a data-driven adaptive VSG controller can be obtained. By using the proposed controller, the inverter-based distributed generator can adaptively adjust its control variables based on current observations to fulfill the expected targets in model-free fashion. Finally, simulation results validate the feasibility and effectiveness of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗