Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Stators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Overall and blade-element performance of a transonic compressor stage with multiple-circular-arc blades at tip speed of 419 meters per second

A 50-centimeter-diameter axial-flow transonic compressor stage with multiple-circular-arc blades was designed and tested to study the effects of blade shape on efficiency and stall margin. At design speed, peak efficiency of 0.80 occurred at an equivalent weight flow of 29.0 kilograms per second. Measured total pressure ratio and total temperature ratio at peak efficiency were 1.69 and 1.20, respectively. The stall margin at design speed and an equivalent weight flow of 29.0 kilograms per second was 9 percent. The measured stall margin at design weight flow and speed was 15 percent. A comparison of rotor performance made with and without the stator showed a decrease in pressure ratio, peak efficiency, and maximum weight flow with the addition of the stator.

Kovich, G.↗

Performance of a 1.20 pressure ratio STOL fan stage at three rotor blade setting angles

A model of a short takeoff and landing (STOL) fan stage was testedin a single-stage compressor research facility. Surveys of the airflow conditions ahead of the rotor, between the rotor and stator, and behind the stator were made over the stable operating range of the stage. At the design speed of 213.3 meters per second and a weight flow of 31.2 kilograms per second, the stage pressure ratio of 1.15 was less than the design value of 1.2. The stage was tested with the rotor blades reset for more flow. Design pressure ratio was achieved and surpassed with the minus 5 deg and minus 7 deg resets, respectively. The stage efficiency was 0.88 for the minus 5 deg reset and 0.85 for the minus 7 deg reset.

Lewis, G. W., Jr.↗

Rotor windage losses for Lundell alternators.

A range of experimental data was generated to permit accurate calculation of the windage power loss for Lundell alternator design. Windage tests were conducted on two concentric rotor-stator configurations in ambient air, producing Reynolds numbers as high as 100,000. Cylindrical rotors 10 and 12 inches in diameter were operated up to 24,000 rpm, and an 8 inch diameter Lundell rotor was operated up to 36,000 rpm. Gap-to-radius ratios of 0.01, 0.02 and 0.04 were tested. Tests were also conducted with axial slots machined on the stator surfaces to simulate alternator winding slots. Using the data obtained, a method was developed to calculate the windage loss for any Lundell alternator given the geometry and cavity conditions.

Gorland, S. H.↗

Design and performance of a high-pressure-ratio, highly loaded axial-flow transonic compressor space

A 50-cm-diam. axial-flow transonic compressor stage with multiple-circular-arc blades was designed and tested. At design speed, a rotor peak efficiency of 0.85 occurred at an equivalent weight flow of 29.3 kg/sec. Stage peak efficiency was 0.79 at 28.6 kg/sec. Stage total pressure ratio at peak efficiency was 1.84. The stall margin at design speed was 5 percent. Rotor and stator losses were higher than predicted. The stator choked at design flow.

Lewis, G. W., Jr.↗

Overall and blade-element performance of a 1.20-pressure-ratio fan stage at design blade setting angle

A 51-cm-diam. model of a short-haul fan stage was tested. Surveys of the air flow conditions ahead of the rotor, between the rotor and stator, and behind the stator were made over the stable operating range of the stage. At the design speed of 213.3 m/sec and weight flow of 26.7 kg/sec, the stage pressure ratio and efficiency are 1.18 and 0.87, respectively. The rotor peak efficiency of 0.92 occurred at flow rate of 30.5 kg/sec. Peak stage efficiency of 0.09 was obtained at 110 percent speed at a pressure ratio of 1.218 and a weight flow of 30.2 kg/sec. Maximum stage pressure ratio is 1.269 at 120 percent speed.

Lewis, G. W., Jr.↗

Transonic compressor technology advancements

The highlights of the NASA program on transonic compressors are presented. Effects of blade shape and throat area on losses and flow range are discussed. Some effects of casing treatment on stall margin are presented. Results of tests with varying solidity are also presented. High Mach number, highly loaded stators are discussed and some results of stator hub slit suction are presented.

Benser, W. A.↗

Cold-air experimental investigation of a turbine with blade trailing edge coolant ejection. 1: Single-stage turbine

Tests were made on a 0.762-meter-tip-diameter research turbine to determine the effect of blade coolant flow on its aerodynamic performance. Both stator and rotor blades had trailing-edge slots for coolant ejection. The turbine was tested over a range of speed and pressure ratio. High primary efficiencies, calculated on the basis of primary air only, were obtained. The efficiency attained was identical to that reported for the turbine from a previous investigation were only slotted stator blades where incorporated in the turbine and tested. And it also compares with results for the turbine with solid blading. Independently varying the rotor coolant flow showed that rotor cooling imposed a severe penalty on turbine efficiency. The thermodynamic efficiency, which accounts for the ideal energies of both blade coolant flows, decreased linearly with rotor coolant at a rate of about 0.7 percent per percent rotor coolant fraction.

Schum, H. J.↗

NASA vane alloy boasts high-temperature strength

The higher inlet-gas temperatures in new aircraft turbine engines make it necessary to use improved superalloys in engine design. Such superalloys are provided by WAZ alloys. NASA has explored the Ni-W-Al system in an attempt to find higher-strength nickel-based alloys for use as stator vane materials. Critical performance goals have been met with the new alloy WAZ-16. With suitable protective coatings, WAZ-16 appears to have considerable potential for high-temperature stator vane applications.

Waters, W. J.↗

The effect of circumferential distortion on fan performance at two levels of blade loading

Single stage fans designed for two levels of pressure ratio or blade loading (rotor tip D-factor of 0.43 and 0.54) were subjected to screen-induced circumferential distortions of 90-degree extent. Both fan rotors were designed for a blade tip speed of 425 m/sec, blade solidity of 1.3 and a hub-to-tip radius ratio of 0.5. Circumferential measurements of total pressure, temperature, static pressure, and flow angle were obtained at the hub, mean and tip radii at five axial stations (three between the screen and rotor and behind rotor and stator blade rows). Rotor loading level did not appear to have a significant influence on rotor response to distorted flow. Losses in overall pressure ratio due to distortion were most severe in the stator hub region of the more highly loaded stage. At the near stall operating condition tip and hub regions of (either) rotor demonstrated different response characteristics to the distorted flow. No effect of loading was apparent on interactions between rotor and upstream distorted flow fields.

Hartmann, M. J.↗

Overall and blade element performance of a 1.20 pressure ratio fan stage with rotor blades reset -7 deg

A 51-cm-diam model of a fan stage for short haul aircraft was tested in a single stage compressor research facility. The rotor blades were set 7 deg toward the axial direction (opened) from the design setting angle. Surveys of the air flow conditions ahead of the rotor, between the rotor and stator, and behind the stator were made over the stable operating range of the stage. At the design speed and a weight flow of 30.9 kg/sec, the stage pressure ratio and efficiency were 1.205 and 0.85, respectively. The design speed rotor peak efficiency of 0.90 occurred at a flow rate of 32.5 kg/sec.

Lewis, G. W., Jr.↗

Overall and blade element performance of a 1.20-pressure-ratio fan stage with rotor blades reset -5 deg

A 51-cm-diam model of a fan stage for a short haul aircraft was tested in a single stage-compressor research facility. The rotor blades were set 5 deg toward the axial direction (opened) from design setting angle. Surveys of the air flow conditions ahead of the rotor, between the rotor and stator, and behind the stator were made over the stable operating range of the stage. At the design speed of 213.3 m/sec and a weight flow of 31.5 kg/sec, the stage pressure ratio and efficiency were 1.195 and 0.88, respectively. The design speed rotor peak efficiency of 0.91 occurred at the same flow rate.

Lewis, G. W., Jr.↗

Single-stage experimental evaluation of low aspect ratio, highly loaded blading for compressors. Part 9: Stage F and stage G, volume 1

Two single-stage, 0.77 hub/tip ratio axial-flow compressors were tested to evaluate the effectiveness of low aspect ratio blading as a means of obtaining higher stage loadings. One compressor, designated Stage F, was comprised of circular arc blading with an aspect ratio of 0.9 for both the rotor and stator. This compressor was tested with uniform inlet flow, hub radial, tip radial, and 180 deg arc circumferential inlet distortion. The second compressor, designated Stage G, was comprised of multiple circular arc blading with an aspect ratio of 1.0 for both the rotor and stator. This compressor was tested with uniform inlet flow only. Design rotor tip speeds for Rotor F and Rotor G were 285 m/sec (934 ft/sec) and 327 m/sec (1,074 ft/sec) respectively. Both stages operated at high loading levels with adequate efficiency and operating range. The peak efficiencies and corresponding average stage diffusion factors for Stages F and G at design rotor speed were 86.4% and 84.1% and 0.59 and 0.55 respectively. The surge margin at peak efficiency for Stage F was 12.6% and the corresponding value for Stage G was 16.5%. Both stages experienced a loss in efficiency with increasing rotor speed; however, the multiple circular arc rotor delayed the characteristic loss in efficiency within increasing Mach number to higher Mach number.

Cheatham, J. G.↗

Cooled-turbine aerodynamic performance prediction from reduced primary to coolant total-temperature-ratio results

The prediction of the cooled aerodynamic performance, for both stators and turbines, at actual primary to coolant inlet total temperature ratios from the results obtained at a reduced total temperature ratio is described. Theoretical and available experimental results were compared for convection film and transpiration cooled stator vanes and for a film cooled, single stage core turbine. For these tests the total temperature ratio varied from near 1.0 to about 2.7. The agreement between the theoretical and the experimental results was, in general, reasonable.

Goldman, L. J.↗

Losses in radial inflow turbines

A study was conducted to determine experimentally and theoretically the losses in radial inflow turbine nozzles. Extensive experimental data was obtained to investigate the flow behavior in a full-scale radial turbine stator annulus. A theoretical model to predict the losses in both the vaned and vaneless regions of the nozzle was developed. In this analysis, the interaction effects between the stator and the rotor are not considered. It was found that the losses incurred due to the end wall boundary layers can be significant, especially if they are characterized by a strong crossflow. The losses estimated using the analytical study are compared with the experimentally determined values.

Khalil, I. M.↗

Advanced acoustic and aerodynamic 20-inch fan program

The aerodynamic analyses, mechanical analyses, and stress tests of a 20-inch diameter advanced fan design intended for acoustic investigation by NASA-LeRC are discussed. A high tip speed transonic fan rotor was scaled directly to 20.0 inches (0.508 m) from a 28.74-inch (0.73-m) diameter rotor. A new stator was designed and fabricated for the fan and incorporated with a test rig housing and adapter hardware for installation in the NASA-LeRC Jet Noise Facility for acoustic evaluation. The stator was designed to allow mounting at three axial locations, and the fan, housing, and adapters are reversible so that either the inlet or the exhaust ends of the assembly face the open room of the test facility. Excellent aerodynamic performance is predicted, and a low noise signature is expected since the unique aerodynamic design features of this fan are directly conductive to producing minimum sound power.

Erwin, J. R.↗

Detailed design of a quiet high flow fan

A single stage fan was designed to demonstrate the noise abatement properties of near-sonic inlet flow and long-chord stator vanes for the reduction of both upstream and downstream propagated fan source noise. It is designed to produce a pressure ratio of 1.653:1 with an adiabatic efficiency of 83.9%. The fan has a 508 mm inlet diameter with a hub/tip ratio of 0.426 and a design tip speed of 533.4 m/sec. The design inlet specific flow rate is 219.71 kg/sec sq m and there are 10 tandem stator vanes with a combined aspect ratio of 0.54.

Soltau, J. D.↗

Cold air performance of a 12.766-centimeter-tip-diameter axial-flow cooled turbine. 2: Effect of air ejection on turbine performance

An air cooled version of a single-stage, axial-flow turbine was investigated to determine aerodynamic performance with and without air ejection from the stator and rotor blades surfaces to simulate the effect of cooling air discharge. Air ejection rate was varied from 0 to 10 percent of turbine mass flow for both the stator and the rotor. A primary-to-air ejection temperature ratio of about 1 was maintained.

Haas, J. E.↗

Acoustic performance of two 1.83-meter-diameter fans designed for a wind-tunnel drive system

A parametric study was made of the noise generated by two 1.83-m (6-ft) diameter fans operating up to a maximum pressure ratio of 1.03. One fan had 15 rotor blades, 23 stator blades, and a maximum rotational speed of 1200 rpm. The other fan had 9 rotor blades, 13 stator blades, and a maximum speed of 2,000 rpm. The fans were approximately 1/7-scale models of the 12.2-m (40-ft) diameter fans proposed for repowering the NASA-Ames 40- by 80 foot wind tunnel. The fans were operated individually in a 23.8-m (78-ft) long duct. Sound pressure levels in the duct were used to determine radiated acoustic power as fan speed, blade angle, and mass flow were varied. Results show that the low speed fan was slightly quieter than the high speed fan and, when scaled to full scale, would be 16 db quieter than the present wind tunnel fans. The fan noise varied directly with thrust regardless of whether thrust was varied by rotational speed or blade setting for the ranges studied.

Soderman, P. R.↗