Advanced Methods for Determining Prediction Uncertainty in Model-Based Prognostics with Application to Planetary Rovers

Prognostics is centered on predicting the time of and time until adverse events in components, subsystems, and systems. It typically involves both a state estimation phase, in which the current health state of a system is identified, and a prediction phase, in which the state is projected forward in time. Since prognostics is mainly a prediction problem, prognostic approaches cannot avoid uncertainty, which arises due to several sources. Prognostics algorithms must both characterize this uncertainty and incorporate it into the predictions so that informed decisions can be made about the system. In this paper, we describe three methods to solve these problems, including Monte Carlo-, unscented transform-, and first-order reliability-based methods. Using a planetary rover as a case study, we demonstrate and compare the different methods in simulation for battery end-of-discharge prediction.

prognosis↗

Mid-Air Range-Visual-Inertial Estimator Initialization for Micro Air Vehicles

Monocular Visual-Inertial Odometry (VIO) has become ubiquitous for navigation of autonomous Micro Air Vehicles (MAVs). Yet, state-of-the-art VIO is still very failure- prone, which can have dramatic consequences. To prevent this, VIO must be able to re-initialize in mid-air, either during a free fall or on a constant horizontal velocity trajectory after attitude control has been re-established. However, for both of these trajectories, the visual scale cannot be observed with VIO batch initializers because of the absence of acceleration change. We propose to use a small and lightweight laser range finder and a scene facet model to initialize vision-based navigation at the right scale under any motion condition and over any scene structure. This new range constraint is integrated into a visual-inertial bundle adjustment initializer. We demonstrate in simulation and real data how this approach can address mid-air state estimation failure in real-time and analyze the sensitivity of estimators to initial state errors.

Brockers, Roland↗

Coordinated Inverter Control to Increase Dynamic PV Hosting Capacity: A Real-Time Optimal Power Flow Approach

High penetrations of distributed photovoltaics (PV) could cause adverse grid impacts, such as voltage violations. The recent development in inverter technologies provides the opportunity to develop control systems to realize effective PV governance and thus to improve dynamic PV hosting capacity for distribution grids. In this paper, a novel distributed energy resource management system (DERMS) solution is proposed by adopting the real-time optimal power flow (OPF) approach for coordinated control of the distributed PV inverters. The proposed approach eliminates the dependence on load knowledge via measurement feedback correction, and it can be implemented in real time. One challenge is that the technique is sensitive to the data availability and integrity of voltage measurements. Therefore, a decentralized DERMS approach is developed by leveraging the concepts of state estimation. The framework and the effectiveness of the solution approach are numerically demonstrated on a real distribution feeder in Southern California.

14 SOLAR ENERGY↗

On the Use of Smart Meter Data to Estimate the Voltage Magnitude on the Primary Side of Distribution Service Transformers

This paper develops a novel method to estimate the voltage magnitude on the primary side of distribution service transformers. The proposed method relies exclusively on smart meters, and therefore it is fully data-driven. This is an important feature because electric utilities have detailed models of only the primary network - that is, the network between the distribution substation and the primary side of service transformers that are installed closer to end-customer sites. The network that connects the secondary side of service transformers to end-customer sites, referred to as the secondary network, is simply represented by a lumped load. For each secondary network, the proposed method uses data acquired from only 2 smart meters: the closest and the farthest-in the sense of electrical distance - from the service transformer. As a reference to this feature, the proposed method is named SM2Vp. To our knowledge, this is the first time a method is shown to provide actionable information for realtime operation and control of power distribution grids using only two smart meters per secondary network. This is important because utilities have experienced barriers in managing and using large data sets for real-time operation and control. SM2Vp is primarily intended to provide pseudo-measurements for distribution system state estimation, but it can also be used directly for voltage control schemes. The performance of SM2Vp is demonstrated by numerical simulations carried out on three secondary network synthetic models and by using field data provided by a utility partner serving customers in southwestern California. A maximum relative error of approximately 3.9% or less is observed for the primary voltage magnitude estimates in all numerical experiments.

distribution service transformer↗

Phasor Measurement Unit and Its Application in Modern Power Systems

The introduction of phasor measuring units (PMUs) in power systems significantly improves the possibilities for monitoring and analyzing power system dynamics. Synchronized measurements make it possible to directly measure phase angles between corresponding phasors in different locations within the power system. Improved monitoring and remedial action capabilities allow network operators to utilize the existing power system in a more efficient way. Improved information allows fast and reliable emergency actions, which reduces the need for relatively high transmission margins required by potential power system disturbances. In this chapter, the applications of PMU in modern power systems are presented. Specifically, the topics touched in this chapter include state estimation, voltage and transient stability, oscillation monitoring, event and fault detection, situation awareness, and model validation. A case study using Characteristic Ellipsoid method based on PMU to monitor power system dynamic is presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On the Use of Smart Meter Data to Estimate the Voltage Magnitude on the Primary Side of Distribution Service Transformers: Preprint

This paper develops a novel method to estimate the voltage magnitude on the primary side of distribution service transformers. The proposed method relies exclusively on smart meters, and therefore it is fully data-driven. This is an important feature because electric utilities have detailed models of only the primary network--that is, the network between the distribution substation and the primary side of service transformers that are installed closer to end-customer sites. The network that connects the secondary side of service transformers to end-customer sites, referred to as the secondary network, is simply represented by a lumped load. For each secondary network, the proposed method uses data acquired from only 2 smart meters: the closest and the farthest--in the sense of electrical distance--from the service transformer. As a reference to this feature, the proposed method is named SM2Vp. To our knowledge, this is the first time a method is shown to provide actionable information for real-time operation and control of power distribution grids using only two smart meters per secondary network. This is important because utilities have experienced barriers in managing and using large data sets for real-time operation and control. SM2Vp is primarily intended to provide pseudo-measurements for distribution system state estimation, but it can also be used directly for voltage control schemes. The performance of SM2Vp is demonstrated by numerical simulations carried out on three secondary network synthetic models and by using field data provided by a utility partner serving customers in southwestern California. A maximum relative error of approximately 3.9% or less is observed for the primary voltage magnitude estimates in all numerical experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Value of Faster Computation for Power Grid Operation

As a result of the grid evolution meeting the information revolution, the power grid is becoming far more complex than it used to be. How to feed data in, perform analysis, and extract information in a real-time manner is a fundamental challenge in today’s power grid operation, not to mention the significantly increased complexity in the smart grid environment. Therefore, high performance computing (HPC) becomes one of the advanced technologies used to meet the requirement of real-time operation. This paper presents benefit case studies to show the value of fast computation for operation. Two fundamental operation functions, state estimation (SE) and contingency analysis (CA), are used as examples. In contrast with today’s tools, fast SE can estimate system status in a few seconds—comparable to measurement cycles. Fast CA can solve more contingencies in a shorter period, reducing the possibility of missing critical contingencies. The benefit case study results clearly show the value of faster computation for increasing the reliability and efficiency of power system operation.

high performance computing↗

Telescope Multi-Field Wavefront Control with a Kalman Filter

An effective multi-field wavefront control (WFC) approach is demonstrated for an actuated, segmented space telescope using wavefront measurements at the exit pupil, and the optical and computational implications of this approach are discussed. The integration of a Kalman Filter as an optical state estimator into the wavefront control process to further improve the robustness of the optical alignment of the telescope will also be discussed. Through a comparison of WFC performances between on-orbit and ground-test optical system configurations, the connection (and a possible disconnection) between WFC and optical system alignment under these circumstances are analyzed. Our MACOS-based computer simulation results will be presented and discussed.

optical state estimation and correction↗

Computational Challenges for Power System Operation

As the power grid technology evolution and information technology revolution converge, power grids are witnessing a revolutionary transition, represented by emerging grid technologies and large scale deployment of new sensors and meters in networks. This transition brings opportunities, as well as computational challenges in the field of power grid analysis and operation. This paper presents some research outcomes in the areas of parallel state estimation using the preconditioned conjugated gradient method, parallel contingency analysis with a dynamic load balancing scheme and distributed system architecture. Based on this research, three types of computational challenges are identified: highly coupled applications, loosely coupled applications, and centralized and distributed applications. Recommendations for future work for power grid applications are also presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Hybrid Data-Driven and Model-Based Anomaly Detection Scheme for DER Operation

This paper proposes a hybrid data and model-based anomaly detection scheme to secure the operation of distributed energy resources (DERs) in distribution grids. Data-driven autoencoders are set up at the edge device level and they use local DER operational data as inputs. The abnormal statuses are detected by analyzing reconstruction errors. In parallel, modelbased state estimation (SE) is set up at the central level and it uses system-wide models and measurements as data inputs. The anomalies are identified by analyzing measurement residuals. The hybrid scheme preserves the benefits of both data-driven and model-based analyses and thus improves the robustness and the accuracy of anomaly detection. Numerical tests based on the model of a real distribution feeder in Southern California highlight the proposed scheme's effectiveness and benefits.

anomaly detection↗

A Hybrid Data-Driven and Model-Based Anomaly Detection Scheme for DER Operation: Preprint

This paper proposes a hybrid data and model-based anomaly detection for securing the operation of distributed energy resources (DERs) in distribution grids. Data-driven autoencoders (AE) are set up at the edge level by taking local DER data and detect anomalous operations by leveraging the reconstruction ability. In parallel, model-based state estimation (SE) is running at the system level by taking system models and measurements, the anomalies are identified by analyzing the measurements residual. The hybrid scheme preserves the benefits of both data-driven and model-based analysis and thus improves the robustness and accuracy of anomaly detection. It can be established by getting full use of the existing infrastructures in distribution grids. Numerical tests on a realistic distribution feeder in Southern California highlight the effectiveness as well as benefits of the proposed scheme.

anomaly detection↗

Experimental validation of a Kalman observer using linearized OpenFAST and a fully instrumented 1:70 model

Abstract To enable real‐time monitoring and control strategies for floating offshore wind turbines, accurate information about the state of the system is needed. This paper details the application of a Kalman filter to the UMaine VolturnUS‐S floating wind platform to provide accurate state estimates in real time using minimal system measurements. The midfidelity nonlinear simulation tool OpenFAST was used to generate the underlying linear state‐space model for the Kalman filter. This linear model and its limitations are demonstrated through comparison with experimental data collected on a 1:70 froude‐scaled model of the floating platform and tower. Using a selection of five measurements from the real system, a Kalman filter was developed to provide estimates for the remaining system states and measurements. These estimates were then validated against the experimental values collected from testing of the scale model. Validation of the Kalman filter produced accurate estimates of surge, heave, and tower base bending moment, measurements of which were not available to the Kalman filter. Performance of the Kalman filter was tested and validated over a range of sea conditions from rated wind speed to storm events and demonstrated robustness in the Kalman filter to maintain accuracy across all operating conditions despite significant error in the underlying linear model for extreme conditions.

17 WIND ENERGY↗

Hierarchical Speed Planner for Automated Vehicles: A Framework for Lagrangian Variable Speed Limit in Mixed-Autonomy Traffic

Here, this article presents a novel hierarchical speed planning framework for variable speed limits in mixed-autonomy traffic environments, leveraging server-side macroscopic control and vehicle-side microscopic execution. The framework integrates real-time traffic state estimation (TSE) and reinforcement learning (RL)-based control to mitigate congestion and improve traffic flow. A TSE enhancement module combines macroscopic data from sources like INRIX with high-resolution observations from connected autonomous vehicles (CAVs), enabling predictive modeling to address latency and noise. The target speed design module employs kernel smoothing and a buffer zone strategy to optimize traffic density and flow around bottlenecks. The proposed system was validated in the largest open-road test to date with 100 CAVs, demonstrating an overall 8% traffic density decrease, with a specific decrease of 7% upstream, 10% downstream, and a 52% decrease during the congestion formation phase at bottlenecks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Voltage Stability Constrained Moving Target Defense Against Net Load Redistribution Attacks

Moving target defense (MTD) using distributed flexible AC transmission system (D-FACTS) devices is a promising defense strategy to detect stealthy false data injection (FDI) attacks against the power system state estimation. However, all existing studies myopically perturb the reactance of D-FACTS lines without considering the system voltage stability. In this paper, we first illustrate voltage instability induced by MTDs in a three-bus system. To address this issue, we further propose a novel MTD framework that explicitly considers system voltage stability by using continuation power flow and voltage stability indices. We mathematically derive the sensitivity matrix of voltage stability index to line impedance, on which an optimization problem for maximizing voltage stability index is formulated. This framework is tested on the IEEE 14-bus and the IEEE 118-bus transmission systems, in which net load redistribution attacks are launched by sophisticated attackers. Here, the simulation results show the effectiveness of the proposed framework in circumventing the voltage instability while maintaining the detection effectiveness of MTD. We conduct case studies with and without the proposed framework under different MTD planning and operational methods. The impacts of the proposed two methods on attack detection effectiveness and system economic metrics are also revealed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive filtering with correlated state noise

An adaptive filter which uses a minimum variance criteria to estimate state noise covariance is presented. It is not necessary to assume white state noise in order to implement the filter. Simulation results are given which demonstrate that the filter tracks a satellite in the presence of modeling errors better than a conventional minimum variance filter with state noise. It is also shown that the propagated convariance matrix of the filter is an accurate indicator of the filter's performance.

Argentiero, P.↗