Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Software assurance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

The Aviation Performance Measuring System (APMS): An Integrated Suite of Tools for Measuring Performance and Safety

This is a report of work in progress. In it, I summarize the status of the research and development of the Aviation Performance Measuring System (APMS) for managing, processing, and analyzing digital flight-recorded data, The objectives of the NASA-FAA APMS research project are to establish a sound scientific and technological basis for flight-data analysis, to define an open and flexible architecture for flight-data analysis systems, and to articulate guidelines for a standardized database structure on which to continue to build future flight-data-analysis extensions. APMS offers to the air transport community an open, voluntary standard for flight-data-analysis software; a standard that will help to ensure suitable functionality and data interchangeability among competing software programs. APMS will develop and document the methodologies, algorithms, and procedures for data management and analyses to enable users to easily interpret the implications regarding safety and efficiency of operations. APMS does not entail the implementation of a nationwide flight-data-collection system. It is intended to provide technical tools to ease the large-scale implementation of flight-data analyses at both the air-carrier and the national-airspace levels in support of their Flight Operations and Quality Assurance (FOQA) Programs and Advanced Qualifications Programs (AQP). APMS cannot meet its objectives unless it develops tools that go substantially beyond the capabilities of the current commercially available software and supporting analytic methods that are mainly designed to count special events. These existing capabilities, while of proven value, were created primarily with the needs-of aircrews in mind. APMS tools must serve the needs of the government and air carriers, as well as aircrews, to fully support the FOQA and AQP programs. They must be able to derive knowledge not only through the analysis of single flights (special-event detection), but also through statistical evaluation of the performance of large groups of flights. This paper describes the integrated suite of tools that will assist analysts in evaluating the operational performance and safety of the national air transport system, the air carrier, and the aircrew.

Statler, Irving C.↗

Developing A Dependable Multi-Agent Rover Swarm Using cFS

The future of space exploration lies in cooperative autonomous systems. Ensuring their high integrity remains a challenge. The Robust Software Engineering group at NASA Ames Research Center has been developing the Troupe project to explore the challenges with developing and assuring high integrity of cooperative autonomous robotic systems. In particular, Troupe aims to develop a swarm of autonomous rovers capable of mapping unknown terrain and assure their high integrity using the advanced V&V tools developed in the group. In this paper, we present the evolution of the design of Troupe. We focus on the lessons learned in developing and assuring the rover swarm using core Flight System (cFS). In particular, we discuss the benefits and challenges in applying model-based development to develop the rover swarm.

space systems↗

Developing A Dependable Multi-Agent Rover Swarm Using cFS

The future of space exploration lies in cooperative autonomous systems. Ensuring their high integrity remains a challenge. The Robust Software Engineering group at NASA Ames Research Center has been developing the Troupe project to explore the challenges with developing and assuring high integrity of cooperative autonomous robotic systems. In particular, Troupe aims to develop a swarm of autonomous rovers capable of mapping unknown terrain and assure their high integrity using the advanced V&V tools developed in the group. In this paper, we present the evolution of the design of Troupe. We focus on the lessons learned in developing and assuring the rover swarm using core Flight System (cFS). In particular, we discuss the benefits and challenges in applying model-based development to develop the rover swarm.

space systems↗

Reducing software security risk through an integrated approach research initiative model based verification of the Secure Socket Layer (SSL) Protocol

This document discusses the verification of the Secure Socket Layer (SSL) communication protocol as a demonstration of the Model Based Verification (MBV) portion of the verification instrument set being developed under the Reducing Software Security Risk (RSSR) Trough an Integrated Approach research initiative. Code Q of the National Aeronautics and Space Administration (NASA) funds this project. The NASA Goddard Independent Verification and Validation (IV&V) facility manages this research program at the NASA agency level and the Assurance Technology Program Office (ATPO) manages the research locally at the Jet Propulsion Laboratory (California institute of Technology) where the research is being carried out.

software security↗

SU-E-P-05: Is Routine Treatment Planning System Quality Assurance Necessary?

Purpose: To evaluate the variation of dose calculations using a treatment planning system (TPS) over a two year period and assessment of the need for TPS QA on regular intervals. Methods: Two phantoms containing solid water and lung- and bone-equivalent heterogeneities were constructed in two different institutions for the same brand treatment planning system. Multiple plans, consisting of photons and electron beams, including IMRT and VMAT ones, were created and calculated on the phantoms. The accuracy of dose computation in the phantoms was evaluated at the onset by dose measurements within the phantoms. The dose values at up to 24 points of interest (POI) within the solid water, lung, and bone slabs, as well as mean doses to several regions of interest (ROI), were re-calculated over a two-year period which included two software upgrades. The variations in POI and ROI dose values were analyzed and evaluated. Results: The computed doses vary slightly month-over-month. There are noticeable variations at the times of software upgrade, if the upgrade involves remodeling and/or re-commissioning of the beams. The variations are larger in certain points within the phantom, usually in the buildup region or near interfaces, and are almost non-existent for electron beams. Conclusion: Routine TPS QA is recommended by AAPM and other professional societies, and is often required by accreditation organizations. The frequency and type of QA, though, is subject to debate. The results presented here demonstrate that the frequency of these tests could be at longer intervals than monthly. However, it is essential to perform TPS QA at the time of commissioning and after each software upgrade.

60 APPLIED LIFE SCIENCES↗

Optical imaging analysis of microscopic radiation dose gradients in Gafchromic EBT film using a digital microscope

By providing superior localization and immobilization, stereotactic radiosurgery (SRS) is capable of delivering millimeter spheres of dose to intracranial targets with submillimeter precision. Several authors have proposed new SRS solutions to dramatically reduce beam penumbra to hundreds of microns. These solutions require new quality assurance methods capable of penumbra measurement at the micron scale. This article examines the capability of a digital microscope, with translation stage and associated software, to resolve dose gradients in Gafchromic EBT film at this level. To produce very steep penumbra, films were irradiated in phantom beneath pinhole collimators using lower energy x rays (100 kVp, 300 kVp, and Iridium-192) and minimal geometric penumbra contribution. For film analysis, a method was developed which improved the signal to noise ratio by finding the center of the irradiation spot, generating several radial dose profiles and averaging these to obtain the final off-axis dose profile. Optical density was converted to dose using a calibration curve. The experimentally determined off-axis dose profiles were compared with MCNP Monte Carlo simulations which replicated the irradiation geometry and served to validate our measured data. The measured 80%-20% penumbral widths were 46 {mu}m{+-}26 {mu}m (100 kVp, 2 mm field size), 69 {mu}m{+-}27 {mu}m (300 kVp, 2 mm field size), and 241 {mu}m{+-}31 {mu}m (Ir-192, 1 mm field size). These penumbral widths agreed with Monte Carlo simulations within experimental uncertainty. Our findings suggest that reading Gafchromic EBT films using a digital microscope with translation stage is suitable for the quality assurance of very sharp penumbra able to resolve gradients to within at least 30 {mu}m.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Monte Carlo approach to validation of FFF VMAT treatment plans for the TrueBeam linac

Purpose: To commission and benchmark a vendor-supplied (Varian Medical Systems) Monte Carlo phase-space data for the 6 MV flattening filter free (FFF) energy mode on a TrueBeam linear accelerator for the purpose of quality assurance of clinical volumetric modulated arc therapy (VMAT) treatment plans. A method for rendering the phase-space data compatible with BEAMnrc/DOSXYZnrc simulation software package is presented. Methods: Monte Carlo (MC) simulations were performed to benchmark the TrueBeam 6 MV FFF phase space data that have been released by the Varian MC Research team. The simulations to benchmark the phase space data were done in three steps. First, the original phase space which was created on a cylindrical surface was converted into a format that was compatible with BEAMnrc. Second, BEAMnrc was used to create field size specific phase spaces located underneath the jaws. Third, doses were calculated with DOSXYZnrc in a water phantom for fields ranging from 1 Multiplication-Sign 1 to 40 Multiplication-Sign 40 cm{sup 2}. Calculated percent depth doses (PDD), transverse profiles, and output factors were compared with measurements for all the fields simulated. After completing the benchmarking study, three stereotactic body radiotherapy (SBRT) VMAT plans created with the Eclipse treatment planning system (TPS) were calculated with Monte Carlo. Ion chamber and film measurements were also performed on these plans. 3D gamma analysis was used to compare Monte Carlo calculation with TPS calculations and with film measurement. Results: For the benchmarking study, MC calculated and measured values agreed within 1% and 1.5% for PDDs and in-field transverse profiles, respectively, for field sizes >1 Multiplication-Sign 1 cm{sup 2}. Agreements in the 80%-20% penumbra widths were better than 2 mm for all the fields that were compared. With the exception of the 1 Multiplication-Sign 1 cm{sup 2} field, the agreement between measured and calculated output factors was within 1%. It is of note that excellent agreement in output factors for all field sizes including highly asymmetric fields was achieved without accounting for backscatter into the beam monitor chamber. For the SBRT VMAT plans, the agreement between Monte Carlo and ion chamber point dose measurements was within 1%. Excellent agreement between Monte Carlo, treatment planning system and Gafchromic film dose distribution was observed with over 99% of the points in the high dose volume passing the 3%, 3 mm gamma test. Conclusions: The authors have presented a method for making the Varian IAEA compliant 6 MV FFF phase space file of the TrueBeam linac compatible with BEAMnrc/DOSXYZnrc. After benchmarking the modified phase space against measurement, they have demonstrated its potential for use in MC based quality assurance of complex delivery techniques.

60 APPLIED LIFE SCIENCES↗

WE-G-BRA-02: SafetyNet: Automating Radiotherapy QA with An Event Driven Framework

Purpose: Quality assurance is an essential task in radiotherapy that often requires many manual tasks. We investigate the use of an event driven framework in conjunction with software agents to automate QA and eliminate wait times. Methods: An in house developed subscription-publication service, EventNet, was added to the Aria OIS to be a message broker for critical events occurring in the OIS and software agents. Software agents operate without user intervention and perform critical QA steps. The results of the QA are documented and the resulting event is generated and passed back to EventNet. Users can subscribe to those events and receive messages based on custom filters designed to send passing or failing results to physicists or dosimetrists. Agents were developed to expedite the following QA tasks: Plan Revision, Plan 2nd Check, SRS Winston-Lutz isocenter, Treatment History Audit, Treatment Machine Configuration. Results: Plan approval in the Aria OIS was used as the event trigger for plan revision QA and Plan 2nd check agents. The agents pulled the plan data, executed the prescribed QA, stored the results and updated EventNet for publication. The Winston Lutz agent reduced QA time from 20 minutes to 4 minutes and provided a more accurate quantitative estimate of radiation isocenter. The Treatment Machine Configuration agent automatically reports any changes to the Treatment machine or HDR unit configuration. The agents are reliable, act immediately, and execute each task identically every time. Conclusion: An event driven framework has inverted the data chase in our radiotherapy QA process. Rather than have dosimetrists and physicists push data to QA software and pull results back into the OIS, the software agents perform these steps immediately upon receiving the sentinel events from EventNet. Mr Keranen is an employee of Varian Medical Systems. Dr. Moran’s institution receives research support for her effort for a linear accelerator QA project from Varian Medical Systems. Other quality projects involving her effort are funded by Blue Cross Blue Shield of Michigan, Breast Cancer Research Foundation, and the NIH.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-JeP1-04: Deformable Image Registration Performances in Pelvis Patients: Impact of CBCT Image Quality

Purpose: To investigate the accuracy and robustness, against image noise and artifacts (typical of CBCT images), of a commercial algorithm for deformable image registration (DIR), to propagate regions of interest (ROIs) in computational phantoms based on real prostate patient images. Methods: The Anaconda DIR algorithm, implemented in RayStation was tested. Two specific Deformation Vector Fields (DVFs) were applied to the reference data set (CTref) using the ImSimQA software, obtaining two deformed CTs. For each dataset twenty-four different level of noise and/or capping artifacts were applied to simulate CBCT images. DIR was performed between CTref and each deformed CTs and CBCTs. In order to investigate the relationship between image quality parameters and the DIR results (expressed by a logit transform of the Dice Index) a bilinear regression was defined. Results: More than 550 DIR-mapped ROIs were analyzed. The Statistical analysis states that deformation strenght and artifacts were significant prognostic factors of DIR performances, while noise appeared to have a minor role in DIR process as implemented in RayStation as expected by the image similarity metric built in the registration algorithm. Capping artifacts reveals a determinant role for the accuracy of DIR results. Two optimal values for capping artifacts were found to obtain acceptable DIR results (DICE> 075/ 0.85). Various clinical CBCT acquisition protocol were reported to evaluate the significance of the study. Conclusion: This work illustrates the impact of image quality on DIR performance. Clinical issues like Adaptive Radiation Therapy (ART) and Dose Accumulation need accurate and robust DIR software. The RayStation DIR algorithm resulted robust against noise, but sensitive to image artifacts. This result highlights the need of robustness quality assurance against image noise and artifacts in the commissioning of a DIR commercial system and underlines the importance to adopt optimized protocols for CBCT image acquisitions in ART clinical implementation.

60 APPLIED LIFE SCIENCES↗

IER 498: Godiva-IV CAAS benchmark [Slides]

This presentation discusses the benchmark of the IER 498: Godiva-IV criticality accident alarm system (CAAS). It details the goal of the project which is to create a CAAS benchmark capability for Godiva-IV in order to create a shielding benchmark for NCSP software and data, to add geometrically diverse benchmark/benchmarks to the ICSBEP Handbook, to enable more precise measurements at NCERC, and to help assure CAAS performance is as-stated. It also states that work was completed on CED-1 in 2019 and that future work includes the completion of CED-2 in 2020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated Testing Experience of the Linear Aerospike SR-71 Experiment (LASRE) Controller

System controllers must be fail-safe, low cost, flexible to software changes, able to output health and status words, and permit rapid retest qualification. The system controller designed and tested for the aerospike engine program was an attempt to meet these requirements. This paper describes (1) the aerospike controller design, (2) the automated simulation testing techniques, and (3) the real time monitoring data visualization structure. Controller cost was minimized by design of a single-string system that used an off-the-shelf 486 central processing unit (CPU). A linked-list architecture, with states (nodes) defined in a user-friendly state table, accomplished software changes to the controller. Proven to be fail-safe, this system reported the abort cause and automatically reverted to a safe condition for any first failure. A real time simulation and test system automated the software checkout and retest requirements. A program requirement to decode all abort causes in real time during all ground and flight tests assured the safety of flight decisions and the proper execution of mission rules. The design also included health and status words, and provided a real time analysis interpretation for all health and status data.

Larson, Richard R.↗

Hazard Contribution Modes of Machine Learning Components

Amongst the essential steps to be taken towards developing and deploying safe systems with embedded learning-enabled components (LECs)—i.e., software components that use machine learning (ML)—are to analyze and understand the contribution of the constituent LECs to safety, and to assure that those contributions have been appropriately managed. This paper addresses both steps by, first, introducing the otion of hazard contribution modes (HCMs)—a categorization of the ways in which the ML elements of LECs can contribute to hazardous system states; and, second, describing how argumentation patterns can capture the reasoning that can be used to assure HCM mitigation. Our framework is generic in the sense that the categories of HCMs developed i) can admit different learning schemes, i.e., supervised, unsupervised, and reinforcement learning, and ii) are not dependent on the type of system in which the LECs are embedded, i.e., both cyber and cyber-physical systems. One of the goals of this work is to serve a starting point for systematizing LEC safety analysis towards eventually automating it in a tool.

Smith, Colin↗

SU-E-T-126: Application of PIPSpro and EPID for Quality Assurance of Medical Accelerators

Purpose: The purpose is to study applying PIPSpro and EPID for routine quality assurance of medical accelerators. Methods: (1) The coincidence of Light field and radiation field: Placed the FC-2 phantom on the treatment couch at the 100cm SSD. Using jaw set 10×10 cm{sup 2} or 15×15 cm{sup 2} field. Verified that the light field aligns with the engraved squares on the phantom. Placed the Crosshair Marker phantom on the top of the FC-2 phantom with the cross-hair and spherical marker aligned to the center of the light field. Acquired images with EPID and the images should be exported preferably in DICOM format. Analyzed Follow the recommended procedures in the radiation light field module of PIPSpro software.(2)MLC QA:Set up the MLC phantom on the treatment couch at isocenter. Positioned the EPID imager at the highest possible position without colliding with either the couch or the phantom. Created and delivered four different patterns for testing the MLC leaf position, leaf width, multi-port and leaf transmission. (3)Radiation isocenter test: Included the isocenter of collimator rotation, gantry rotation and couch rotation. Set the jaws of the collimator to create a thin field as 0.4cm x 20cm.Irradiated film or EPID using an equidistant 15° spacing angles with rotating collimator, gantry and couch respectively. Results: We analyzed imagers from EPID and film with PIPSPro software. As a Result, we acquired the specifications of medical accelerators quickly. In the meantime, the results were saved to database for trending and future analysis. Conclusion: Quality assurance of medical accelerator is very important. We used PIPSpro and EPID for routine detection, not only improved our efficiency, but also saved the cost. It is an good method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Daily QA of linear accelerators using only EPID and OBI

Purpose: As treatment delivery becomes more complex, there is a pressing need for robust quality assurance (QA) tools to improve efficiency and comprehensiveness while simultaneously maintaining high accuracy and sensitivity. This work aims to present the hardware and software tools developed for comprehensive QA of linear accelerator (LINAC) using only electronic portal imaging devices (EPIDs) and kV flat panel detectors. Methods: A daily QA phantom, which includes two orthogonally positioned phantoms for QA of MV-beams and kV onboard imaging (OBI) is suspended from the gantry accessory holder to test both geometric and dosimetric components of a LINAC and an OBI. The MV component consists of a 0.5 cm water-equivalent plastic sheet incorporating 11 circular steel plugs for transmission measurements through multiple thicknesses and one resolution plug for MV-image quality testing. The kV-phantom consists of a Leeds phantom (TOR-18 FG phantom supplied by Varian) for testing low and high contrast resolutions. In the developed process, the existing LINAC tools were used to automate daily acquisition of MV and kV images and software tools were developed for simultaneous analysis of these images. A method was developed to derive and evaluate traditional QA parameters from these images [output, flatness, symmetry, uniformity, TPR{sub 20/10}, and positional accuracy of the jaws and multileaf collimators (MLCs)]. The EPID-based daily QA tools were validated by performing measurements on a detuned 6 MV beam to test its effectiveness in detecting errors in output, symmetry, energy, and MLC positions. The developed QA process was clinically commissioned, implemented, and evaluated on a Varian TrueBeam LINAC (Varian Medical System, Palo Alto, CA) over a period of three months. Results: Machine output constancy measured with an EPID (as compared against a calibrated ion-chamber) is shown to be within ±0.5%. Beam symmetry and flatness deviations measured using an EPID and a 2D ion-chamber array agree within ±0.5% and ±1.2% for crossline and inline profiles, respectively. MLC position errors of 0.5 mm can be detected using a picket fence test. The field size and phantom positioning accuracy can be determined within 0.5 mm. The entire daily QA process takes ∼15 min to perform tests for 5 photon beams, MLC tests, and imaging checks. Conclusions: The exclusive use of EPID-based QA tools, including a QA phantom and simultaneous analysis software tools, has been demonstrated as a viable, efficient, and comprehensive process for daily evaluation of LINAC performance.

60 APPLIED LIFE SCIENCES↗

Spacelab software development and integration concepts study report, volume 1

The proposed software guidelines to be followed by the European Space Research Organization in the development of software for the Spacelab being developed for use as a payload for the space shuttle are documented. Concepts, techniques, and tools needed to assure the success of a programming project are defined as they relate to operation of the data management subsystem, support of experiments and space applications, use with ground support equipment, and for integration testing.

Rose, P. L.↗

Real-time remote scientific model validation

This paper describes flight results from the use of a CLIPS-based validation facility to compare analyzed data from a space life sciences (SLS) experiment to an investigator's preflight model. The comparison, performed in real-time, either confirms or refutes the model and its predictions. This result then becomes the basis for continuing or modifying the investigator's experiment protocol. Typically, neither the astronaut crew in Spacelab nor the ground-based investigator team are able to react to their experiment data in real time. This facility, part of a larger science advisor system called Principal Investigator in a Box, was flown on the space shuttle in October, 1993. The software system aided the conduct of a human vestibular physiology experiment and was able to outperform humans in the tasks of data integrity assurance, data analysis, and scientific model validation. Of twelve preflight hypotheses associated with investigator's model, seven were confirmed and five were rejected or compromised.

Frainier, Richard↗

An Optimized Integrator Windup Protection Technique Applied to a Turbofan Engine Control

This paper introduces a new technique for providing memoryless integrator windup protection which utilizes readily available optimization software tools. This integrator windup protection synthesis provides a concise methodology for creating integrator windup protection for each actuation system loop independently while assuring both controller and closed loop system stability. The individual actuation system loops' integrator windup protection can then be combined to provide integrator windup protection for the entire system. This technique is applied to an H(exp infinity) based multivariable control designed for a linear model of an advanced afterburning turbofan engine. The resulting transient characteristics are examined for the integrated system while encountering single and multiple actuation limits.

Watts, Stephen R.↗

Cloud Computing Option for Modeling the Debris Environment

NASA’s Digital Transformation Initiative aims to promote the agency’s adoption of current and evolving digital technologies. Through agency-wide collaboration with other NASA teams, the Office of Safety and Mission Assurance (OSMA) has directed the Orbital Debris Program Office and the Meteoroid Environment Office to integrate cloud computing technologies in their publicly released software models: the Orbital Debris Engineering Model (ORDEM) and the Meteoroid Engineering Model (MEM). Decoupling the user interface from the backend processor was key for the software packages to run on a cloud computing framework. Benefits to this design include horizontal scaling of computing resources, user authentication and authorization, and automated deployment. Both models are hosted on a cloud computing platform supported by the NASA authorized IT security and compliance framework. This paper focuses on the new ORDEM web application, which includes the current features of the publicly released ORDEM software with an upgraded frontend design. The underlying ORDEM processor is run on a cloud container, allowing the user to run multiple spacecraft and telescope/radar mode simulations. Featuresexclusive to the ORDEM web application, such as importing multiple TLEs, auto-generated plotting, and the ability to check runtime progress are discussed. Comparisons between the current ORDEM software and the web application are summarized.

Andrew Vavrin↗