Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Soft computing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Transient structured fluctuations in a two-dimensional system with multiple ordered phases

We report the structure of transient fluctuations in the liquid phase of a two-dimensional system that exhibits several ordered phases with different symmetries. The density-temperature phase diagram of the system studied, composed of particles with a repulsive shouldered soft-core pair interaction, has regions with stable liquid and hexatic phases, a square solid phase, two separate hexagonal solid phases, and a quasi-crystalline phase with 12-fold symmetry. We have examined the character of the structured fluctuations by computing the same-time aperture cross correlation function of particle configurations in several fluid regions near to and far from phase transition lines. The two primary goals of our study are (1) determination if the spectrum of structures of the fluctuations in the liquid is broader than or limited to the motifs exhibited by the ordered phases supported by the system and (2) determination of the density domains in the liquid that support particular transient structured fluctuations. In the system studied, along a low-temperature isotherm in the temperature-density plane that intersects all the ordered phases we find that the liquid phase exhibits structured fluctuations with hexagonal symmetry near both liquid-hexatic transition lines. Along the same isotherm and in the stable liquid between the lower density hexatic-to-liquid and the higher density liquid-to-square solid transitions, we find that transient hexagonal ordered fluctuations dominate the liquid region near the hexatic-to-liquid transition and square ordered fluctuations dominate the liquid region near the liquid-to square solid transition, but both of these structured fluctuations occur at all densities between these transition lines. At a higher temperature, at phase points in the liquid above, but close to the density maximum of an underlying transition, there are ordered fluctuations that can be correlated with the structure of the lower temperature phase. Although it is expected that very close to a liquid-ordered phase boundary a structured fluctuation in the liquid will have the same symmetry as the ordered phase, it is not obvious that structured fluctuations in thermodynamic states deep in the liquid phase will be similarly restricted. The most striking result of our calculations is that no evidence is found in the liquid phase for structured fluctuations with other symmetries than those of the ordered phases of the system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A quality assurance framework for the fully automated and objective evaluation of image quality in cone-beam computed tomography

Purpose: Thousands of cone-beam computed tomography (CBCT) scanners for vascular, maxillofacial, neurological, and body imaging are in clinical use today, but there is no consensus on uniform acceptance and constancy testing for image quality (IQ) and dose yet. The authors developed a quality assurance (QA) framework for fully automated and time-efficient performance evaluation of these systems. In addition, the dependence of objective Fourier-based IQ metrics on direction and position in 3D volumes was investigated for CBCT. Methods: The authors designed a dedicated QA phantom 10 cm in length consisting of five compartments, each with a diameter of 10 cm, and an optional extension ring 16 cm in diameter. A homogeneous section of water-equivalent material allows measuring CT value accuracy, image noise and uniformity, and multidimensional global and local noise power spectra (NPS). For the quantitative determination of 3D high-contrast spatial resolution, the modulation transfer function (MTF) of centrally and peripherally positioned aluminum spheres was computed from edge profiles. Additional in-plane and axial resolution patterns were used to assess resolution qualitatively. The characterization of low-contrast detectability as well as CT value linearity and artifact behavior was tested by utilizing sections with soft-tissue-equivalent and metallic inserts. For an automated QA procedure, a phantom detection algorithm was implemented. All tests used in the dedicated QA program were initially verified in simulation studies and experimentally confirmed on a clinical dental CBCT system. Results: The automated IQ evaluation of volume data sets of the dental CBCT system was achieved with the proposed phantom requiring only one scan for the determination of all desired parameters. Typically, less than 5 min were needed for phantom set-up, scanning, and data analysis. Quantitative evaluation of system performance over time by comparison to previous examinations was also verified. The maximum percentage interscan variation of repeated measurements was less than 4% and 1.7% on average for all investigated quality criteria. The NPS-based image noise differed by less than 5% from the conventional standard deviation approach and spatially selective 10% MTF values were well comparable to subjective results obtained with 3D resolution pattern. Determining only transverse spatial resolution and global noise behavior in the central field of measurement turned out to be insufficient. Conclusions: The proposed framework transfers QA routines employed in conventional CT in an advanced version to CBCT for fully automated and time-efficient evaluation of technical equipment. With the modular phantom design, a routine as well as an expert version for assessing IQ is provided. The QA program can be used for arbitrary CT units to evaluate 3D imaging characteristics automatically.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-176: Results of Images Acquired with Backscattered MV Radiation Using a Pinhole Collimator

Purpose: To ascertain the feasibility of acquiring real time images of small lung tumors from scattered photons while undergoing radiation treatment.There are several methodologies currently used to track tumor location such as MV-cine acquisition and kV fluoroscopy. However, MVcine offers no information parallel to the beam axis while kV fluoroscopy offers little potential for soft tissue discernability while also increasing the patient dose. This study investigates the feasibility of observing an actual simulated tumor while exploring techniques that may improve image quality. Methods: A prototype imager consisting of a gamma camera pinhole collimator and a computed radiography (CR) plate were used in conjunction with a Varian TrueBeam linac. One study consisted of a 2.5 cm diameter solid water cylinder representing a solid tumor imbedded within a lung equivalent material slab. The cylinder with the lung slab was sandwiched between 1 cm lung equivalent slabs and these were sandwiched between 2 slabs of solid water. The top water slab was 1 cm thick. The other imaging study consisted of three different density plugs, 0.46, 1.09, and 1.82 g/cm3 placed on the accelerator couch. The gantry was orientated 70° relative to the CR plate. The slabs and plugs were irradiated with 2000 MU and 500 MU respectively using the 6FFF mode. Results: The solid water plug was visually discernible in the slab phantom. The ratio of the signal coming from the higher density plugs (placed on the treatment couch) to that between the plugs increased from 1.02 to about 3.0 after subtracting the background image acquired with no plugs present. Conclusion: Preliminary results indicate that a lung tumor could be visualized with scattered radiation during treatment. Improvements in discerning an object can be enhanced by filtering out the head leakage and background scattered radiation not emanating from the imaged object.

60 APPLIED LIFE SCIENCES↗

WE-EF-303-10: Single- Detector Proton Radiography as a Portal Imaging Equivalent for Proton Therapy

Purpose: In proton therapy, patient alignment is of critical importance due to the sensitivity of the proton range to tissue heterogeneities. Traditionally proton radiography is used for verification of the water-equivalent path length (WEPL), which dictates the depth protons reach. In this work we propose its use for alignment. Additionally, many new proton centers have cone-beam computed tomography in place of beamline X-ray imaging and so proton radiography offers a unique patient alignment verification similar to portal imaging in photon therapy. Method: Proton radiographs of a CIRS head phantom were acquired using the Beam Imaging System (BIS) (IBA, Louvain-la-Neuve) in a horizontal beamline. A scattered beam was produced using a small, dedicated, range modulator (RM) wheel fabricated out of aluminum. The RM wheel was rotated slowly (20 sec/rev) using a stepper motor to compensate for the frame rate of the BIS (120 ms). Dose rate functions (DRFs) over two RM wheel rotations were acquired. Calibration was made with known thicknesses of homogeneous solid water. For each pixel the time width, skewness and kurtosis of the DRFs were computed. The time width was used to compute the object WEPL. In the heterogeneous phantom, the excess skewness and excess kurtosis (i.e. difference from homogeneous cases) were computed and assessed for suitability for patient set up. Results: The technique allowed for the simultaneous production of images that can be used for WEPL verification, showing few internal details, and excess skewness and kurtosis images that can be used for soft tissue alignment. These latter images highlight areas where range mixing has occurred, correlating with phantom heterogeneities. Conclusion: The excess skewness and kurtosis images contain details that are not visible in the WET images. These images, unique to the time-resolved proton radiographic method, could be used for patient set up according to soft tissues.

60 APPLIED LIFE SCIENCES↗

Technical Note: Radiological properties of tissue surrogates used in a multimodality deformable pelvic phantom for MR-guided radiotherapy

Purpose: Phantom surrogates were developed to allow multimodal [computed tomography (CT), magnetic resonance imaging (MRI), and teletherapy] and anthropomorphic tissue simulation as well as materials and methods to construct deformable organ shapes and anthropomorphic bone models. Methods: Agarose gels of variable concentrations and loadings were investigated to simulate various soft tissue types. Oils, fats, and Vaseline were investigated as surrogates for adipose tissue and bone marrow. Anthropomorphic shapes of bone and organs were realized using 3D-printing techniques based on segmentations of patient CT-scans. All materials were characterized in dual energy CT and MRI to adapt CT numbers, electron density, effective atomic number, as well as T1- and T2-relaxation times to patient and literature values. Results: Soft tissue simulation could be achieved with agarose gels in combination with a gadolinium-based contrast agent and NaF to simulate muscle, prostate, and tumor tissues. Vegetable oils were shown to be a good representation for adipose tissue in all modalities. Inner bone was realized using a mixture of Vaseline and K{sub 2}HPO{sub 4}, resulting in both a fatty bone marrow signal in MRI and inhomogeneous areas of low and high attenuation in CT. The high attenuation of outer bone was additionally adapted by applying gypsum bandages to the 3D-printed hollow bone case with values up to 1200 HU. Deformable hollow organs were manufactured using silicone. Signal loss in the MR images based on the conductivity of the gels needs to be further investigated. Conclusions: The presented surrogates and techniques allow the customized construction of multimodality, anthropomorphic, and deformable phantoms as exemplarily shown for a pelvic phantom, which is intended to study adaptive treatment scenarios in MR-guided radiation therapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Synthase-selected sorting approach identifies a beta-lactone synthase in a nudibranch symbiotic bacterium

Background - Nudibranchs comprise a group of > 6000 marine soft-bodied mollusk species known to use secondary metabolites (natural products) for chemical defense. The full diversity of these metabolites and whether symbiotic microbes are responsible for their synthesis remains unexplored. Another issue in searching for undiscovered natural products is that computational analysis of genomes of uncultured microbes can result in detection of novel biosynthetic gene clusters; however, their in vivo functionality is not guaranteed which limits further exploration of their pharmaceutical or industrial potential. To overcome these challenges, we used a fluorescent pantetheine probe, which produces a fluorescent CoA-analog employed in biosynthesis of secondary metabolites, to label and capture bacterial symbionts actively producing these compounds in the mantle of the nudibranch Doriopsilla fulva. Results - We recovered the genome of Candidatus Doriopsillibacter californiensis from the Ca. Tethybacterales order, an uncultured lineage of sponge symbionts not found in nudibranchs previously. It forms part of the core skin microbiome of D. fulva and is nearly absent in its internal organs. We showed that crude extracts of D. fulva contained secondary metabolites that were consistent with the presence of a beta-lactone encoded in Ca. D. californiensis genome. Beta-lactones represent an underexplored group of secondary metabolites with pharmaceutical potential that have not been reported in nudibranchs previously. Conclusions - Altogether, this study shows how probe-based, targeted sorting approaches can capture bacterial symbionts producing secondary metabolites in vivo.

59 BASIC BIOLOGICAL SCIENCES↗

Wavefront Compensation Segmented Mirror Sensing and Control

The primary mirror of very large submillimeter-wave telescopes will necessarily be segmented into many separate mirror panels. These panels must be continuously co-phased to keep the telescope wavefront error less than a small fraction of a wavelength, to ten microns RMS (root mean square) or less. This performance must be maintained continuously across the full aperture of the telescope, in all pointing conditions, and in a variable thermal environment. A wavefront compensation segmented mirror sensing and control system, consisting of optical edge sensors, Wavefront Compensation Estimator/Controller Soft ware, and segment position actuators is proposed. Optical edge sensors are placed two per each segment-to-segment edge to continuously measure changes in segment state. Segment position actuators (three per segment) are used to move the panels. A computer control system uses the edge sensor measurements to estimate the state of all of the segments and to predict the wavefront error; segment actuator commands are computed that minimize the wavefront error. Translational or rotational motions of one segment relative to the other cause lateral displacement of the light beam, which is measured by the imaging sensor. For high accuracy, the collimator uses a shaped mask, such as one or more slits, so that the light beam forms a pattern on the sensor that permits sensing accuracy of better than 0.1 micron in two axes: in the z or local surface normal direction, and in the y direction parallel to the mirror surface and perpendicular to the beam direction. Using a co-aligned pair of sensors, with the location of the detector and collimated light source interchanged, four degrees of freedom can be sensed: transverse x and y displacements, as well as two bending angles (pitch and yaw). In this approach, each optical edge sensor head has a collimator and an imager, placing one sensor head on each side of a segment gap, with two parallel light beams crossing the gap. Two sets of optical edge sensors are used per segment-to-segment edge, separated by a finite distance along the segment edge, for four optical heads, each with an imager and a collimator. By orienting the beam direction of one edge sensor pair to be +45 away from the segment edge direction, and the other sensor pair to be oriented -45 away from the segment edge direction, all six degrees of freedom of relative motion between the segments can be measured with some redundancy. The software resides in a computer that receives each of the optical edge sensor signals, as well as telescope pointing commands. It feeds back the edge sensor signals to keep the primary mirror figure within specification. It uses a feed-forward control to compensate for global effects such as decollimation of the primary and secondary mirrors due to gravity sag as the telescope pointing changes to track science objects. Three segment position actuators will be provided per segment to enable controlled motions in the piston, tip, and tilt degrees of freedom. These actuators are driven by the software, providing the optical changes needed to keep the telescope phased.

Redding, David C.↗

Towards a fully kinetic 3D electromagnetic particle-in-cell model of streamer formation and dynamics in high-pressure electronegative gases

Streamer and leader formation in high pressure devices is dynamic process involving a broad range of physical phenomena. These include elastic and inelastic particle collisions in the gas, radiation generation, transport and absorption, and electrode interactions. Accurate modeling of these physical processes is essential for a number of applications, including high-current, laser-triggered gas switches. Towards this end, we present a new 3D implicit particle-in-cell simulation model of gas breakdown leading to streamer formation in electronegative gases. The model uses a Monte Carlo treatment for all particle interactions and includes discrete photon generation, transport, and absorption for ultra-violet and soft x-ray radiation. Central to the realization of this fully kinetic particle treatment is an algorithm that manages the total particle count by species while preserving the local momentum distribution functions and conserving charge [D. R. Welch, T. C. Genoni, R. E. Clark, and D. V. Rose, J. Comput. Phys. 227, 143 (2007)]. The simulation model is fully electromagnetic, making it capable of following, for example, the evolution of a gas switch from the point of laser-induced localized breakdown of the gas between electrodes through the successive stages of streamer propagation, initial electrode current connection, and high-current conduction channel evolution, where self-magnetic field effects are likely to be important. We describe the model details and underlying assumptions used and present sample results from 3D simulations of streamer formation and propagation in SF{sub 6}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tumor, Lymph Node, and Lymph Node-to-Tumor Displacements Over a Radiotherapy Series: Analysis of Interfraction and Intrafraction Variations Using Active Breathing Control (ABC) in Lung Cancer

Purpose: To estimate errors in soft tissue-based image guidance due to relative changes between primary tumor (PT) and affected lymph node (LN) position and volume, and to compare the results with bony anatomy-based displacements of PTs and LNs during radiotherapy of lung cancer. Methods and Materials: Weekly repeated breath-hold computed tomography scans were acquired in 17 lung cancer patients undergoing radiotherapy. PTs and affected LNs were manually contoured on all scans after rigid registration. Interfraction and intrafraction displacements in the centers of mass of PTs and LNs relative to bone, as well as LNs relative to PTs (LN-PT), were calculated. Results: The mean volume after 5 weeks was 65% for PTs and 63% for LNs. Systematic and random interfraction displacements were 2.6 to 4.6 mm and 2.7 to 2.9 mm, respectively, for PTs; 2.4 to 3.8 mm and 1.4 to 2.7 mm, respectively, for LNs; and 2.3 to 3.9 mm and 1.9 to 2.8 mm, respectively, for LN-PT. Systematic and random intrafraction displacements were less than 1 mm except in the superoinferior direction. Interfraction LN-PT displacements greater than 3 mm were observed in 67% of fractions and require a safety margin of 12 mm in the lateral direction, 11 mm in the anteroposterior direction, and 9 mm in the superoinferior direction. LN-PT displacements displayed significant time trends (p < 0.0001) and depended on the presence of pathoanatomic conditions of the ipsilateral lung, such as atelectasis. Conclusion: Interfraction LN-PT displacements were mostly systematic and comparable to bony anatomy-based displacements of PTs or LNs alone. Time trends, large volume changes, and the influence of pathoanatomic conditions underline the importance of soft tissue-based image guidance and the potential of plan adaptation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Harnessing ionic complexity: A modeling approach for hierarchical ionic circuit design

Since the 1950s, soft ionic devices have evolved from individual components to an expanding library of sensors, actuators, signal transmitters, and processors. However, integrating these components into complex, multifunctional systems remains challenging due to the nonintuitive and nonlinear interactions between ionic elements. In this work, we address these fundamental challenges by developing a lumped element model that enables interrogation of the physics that governs ionic circuits, as well as rapid design and optimization. Our model captures features specific to ionic charge carriers, while preserving the hierarchical design flexibility and computational efficiency of traditional circuit modeling. We demonstrate that our model can not only fit individual device behavior but also accurately predict the behavior of larger circuits formed by combining those devices. Additionally, we show how our tool utilizes the intrinsic nonlinearities of ionic systems to enable extended functionality, revealing how factors such as ion enrichment, ion leakage, and polymer charge density influence performance. Lastly, we present a fully ionic power supply, sensor, control system, and actuator for a soft robot that adapts its motion in response to environmental salt, illustrating the tool’s potential to accelerate advancements in chemical sensing, biointerfacing, biomimetic systems, and adaptive materials.

42 ENGINEERING↗

Statistical CT noise reduction with multiscale decomposition and penalized weighted least squares in the projection domain

Purposes: The suppression of noise in x-ray computed tomography (CT) imaging is of clinical relevance for diagnostic image quality and the potential for radiation dose saving. Toward this purpose, statistical noise reduction methods in either the image or projection domain have been proposed, which employ a multiscale decomposition to enhance the performance of noise suppression while maintaining image sharpness. Recognizing the advantages of noise suppression in the projection domain, the authors propose a projection domain multiscale penalized weighted least squares (PWLS) method, in which the angular sampling rate is explicitly taken into consideration to account for the possible variation of interview sampling rate in advanced clinical or preclinical applications. Methods: The projection domain multiscale PWLS method is derived by converting an isotropic diffusion partial differential equation in the image domain into the projection domain, wherein a multiscale decomposition is carried out. With adoption of the Markov random field or soft thresholding objective function, the projection domain multiscale PWLS method deals with noise at each scale. To compensate for the degradation in image sharpness caused by the projection domain multiscale PWLS method, an edge enhancement is carried out following the noise reduction. The performance of the proposed method is experimentally evaluated and verified using the projection data simulated by computer and acquired by a CT scanner. Results: The preliminary results show that the proposed projection domain multiscale PWLS method outperforms the projection domain single-scale PWLS method and the image domain multiscale anisotropic diffusion method in noise reduction. In addition, the proposed method can preserve image sharpness very well while the occurrence of 'salt-and-pepper' noise and mosaic artifacts can be avoided. Conclusions: Since the interview sampling rate is taken into account in the projection domain multiscale decomposition, the proposed method is anticipated to be useful in advanced clinical and preclinical applications where the interview sampling rate varies.

60 APPLIED LIFE SCIENCES↗

Entanglement maximization and mirror symmetry in two-Higgs-doublet models

We consider 2-to-2 scatterings of Higgs bosons in a CP-conserving two-Higgs-doublet model (2HDM) and study the implication of maximizing the entanglement in the flavor space, where the two doublets Φ a , a = 1, 2, can be viewed as a qubit: Φ 1 = |0⟩ and Φ 2 = |1⟩. More specifically, we compute the scattering amplitudes for Φ a Φ b → Φ c Φ d and require the outgoing flavor entanglement to be maximal for a full product basis such as the computational basis, which consists of {|00⟩, |01⟩, |10⟩, |11⟩}. In the unbroken phase and turning off the gauge interactions, entanglement maximization results in the appearance of an U(2) × U(2) global symmetry among the quartic couplings, which in general is broken softly by the mass terms. Interestingly, once the Higgs bosons acquire vacuum expectation values, maximal entanglement enforces an exact U(2) × U(2) symmetry, which is spontaneously broken to U(1) × U(1). As a byproduct, this gives rise to Higgs alignment as well as to the existence of 6 massless Nambu-Goldstone bosons. The U(2) × U(2) symmetry can be gauged to lift the massless Goldstones, while maintaining maximal entanglement demands the presence of a discrete Z 2 symmetry interchanging the two gauge sectors. The model is custodially invariant in the scalar sector, and the inclusion of fermions requires a mirror dark sector, related to the standard one by the Z 2 symmetry.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Flying Cages in Traveling Wave Ion Mobility: Influence of the Instrumental Parameters on the Topology of the Host–Guest Complexes

Supramolecular mass spectrometry has emerged in the last decade as an orthogonal method to access, at the molecular level, the structures of noncovalent complexes extracted from the condensed phase to the rarefied gas phase using electrospray ionization. It is often considered that the soft nature of the ESI source confers to the method the capability to generate structural data comparable to those in the condensed phase. In the present paper, using the ammonium ion/cucurbituril combination as a model system, we investigate using ion mobility and computational chemistry the influence of the instrumental parameters on the topology, i.e., internal versus external association, of gaseous host/guest complex ions. MS and theoretical data are confronted to condensed phase data derived from nuclear magnetic resonance spectroscopy to assess whether the instrumental parameters can play an insidious role when trying to derive condensed phase data from mass spectrometry results. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Blow-off momentum from melt and vapor in nuclear deflection scenarios

For Earth-impacting objects that are large in size or have short warning times nuclear explosives are an effective threat mitigation response. Nuclear-based deflection works by means of conservation of momentum: as material is heated by incoming photons and neutrons it is ejected from the body which imparts momentum to the remaining mass of the asteroid. Predicting the complete response of a particular object is difficult, since the ejecta size and velocity distributions rely heavily on the unknown, complicated internal structure of the body. However, lower bounds on the blow-off momentum can be estimated using the melted and vaporized surface material. In this paper, we model the response of a one-dimensional SiO2 surface to monoenergetic soft X-ray, hard X-ray and neutron sources using Arbitrary Lagrangian–Eulerian radiation/hydrodynamic simulations. Errors in the blow-off momentum due to our hydrodynamic mesh resolution are quantified and inform zone sizing that balances numerical discretization error with computational efficiency. We explore deposited energy densities ranging from 1.1 to 200 times the melt energy density for SiO2, and develop an approximate relation that gives the mesh resolution needed for a desired percent error in the blow-off momentum as a function of deposited energy density and melt depth. Using these mesh constraints, the response of our one-dimensional SiO2 surface to the energy sources is simulated, and lower bounds are placed on the melt/vapor blow-off momentum as a function of deposited energy density and source energy type.

79 ASTRONOMY AND ASTROPHYSICS↗

Systematic calibration of an integrated x-ray and optical tomography system for preclinical radiation research

Purpose: The cone beam computed tomography (CBCT) guided small animal radiation research platform (SARRP) has been developed for focal tumor irradiation, allowing laboratory researchers to test basic biological hypotheses that can modify radiotherapy outcomes in ways that were not feasible previously. CBCT provides excellent bone to soft tissue contrast, but is incapable of differentiating tumors from surrounding soft tissue. Bioluminescence tomography (BLT), in contrast, allows direct visualization of even subpalpable tumors and quantitative evaluation of tumor response. Integration of BLT with CBCT offers complementary image information, with CBCT delineating anatomic structures and BLT differentiating luminescent tumors. This study is to develop a systematic method to calibrate an integrated CBCT and BLT imaging system which can be adopted onboard the SARRP to guide focal tumor irradiation. Methods: The integrated imaging system consists of CBCT, diffuse optical tomography (DOT), and BLT. The anatomy acquired from CBCT and optical properties acquired from DOT serve as a priori information for the subsequent BLT reconstruction. Phantoms were designed and procedures were developed to calibrate the CBCT, DOT/BLT, and the entire integrated system. Geometrical calibration was performed to calibrate the CBCT system. Flat field correction was performed to correct the nonuniform response of the optical imaging system. Absolute emittance calibration was performed to convert the camera readout to the emittance at the phantom or animal surface, which enabled the direct reconstruction of the bioluminescence source strength. Phantom and mouse imaging were performed to validate the calibration. Results: All calibration procedures were successfully performed. Both CBCT of a thin wire and a euthanized mouse revealed no spatial artifact, validating the accuracy of the CBCT calibration. The absolute emittance calibration was validated with a 650 nm laser source, resulting in a 3.0% difference between simulated and measured signal. The calibration of the entire system was confirmed through the CBCT and BLT reconstruction of a bioluminescence source placed inside a tissue-simulating optical phantom. Using a spatial region constraint, the source position was reconstructed with less than 1 mm error and the source strength reconstructed with less than 24% error. Conclusions: A practical and systematic method has been developed to calibrate an integrated x-ray and optical tomography imaging system, including the respective CBCT and optical tomography system calibration and the geometrical calibration of the entire system. The method can be modified and adopted to calibrate CBCT and optical tomography systems that are operated independently or hybrid x-ray and optical tomography imaging systems.

60 APPLIED LIFE SCIENCES↗

Image Data Processing System (IDAPS) user manual, S-056 experiment. Volume 1: System description. Volume 2: Batch IDAPS. Volume 3: Interactive IDAPS

Image data processing system (IDAPS) developed to satisfy the image processing requirements of the Skylab S-056 experiment is described. The S-056 experiment was designed to obtain high-resolution photographs of the sun in the far ultraviolet, or soft X-ray, portion of the electromagnetic spectrum. Thirty-five thousand photographs were obtained by the three flights of the program; and, faced with such a massive volume of imagery, the designers of the experiment decided to develop a computer-based system which would reduce the image processing workload. The purpose of the IDAPS User Manual is to give the IDAPS user the necessary information and instructions to effectively utilize the system.

Source record↗

The Soft X-ray Telescope for Solar-A - Design evolution and lessons learned

The Japanese Solar-A satellite mission's Soft X-ray Telescope uses grazing-incidence optics, a CCD detector, and a pair of filter wheels for wavelength selection. A coaxially-mounted visible-light lens furnished sunspot and magnetic plage images, together with aspect information which aids in aligning the soft X-ray images with those from the satellite's Hard X-ray Telescope. Instrument electronics are microprocessor-based, and imbedded in a tightly integrated distributed system. Control software is divided between the instrument microprocessor and the spacecraft control computer.

Bruner, Marilyn E.↗

Towards the clinical implementation of iterative low-dose cone-beam CT reconstruction in image-guided radiation therapy: Cone/ring artifact correction and multiple GPU implementation

Purpose: Compressed sensing (CS)-based iterative reconstruction (IR) techniques are able to reconstruct cone-beam CT (CBCT) images from undersampled noisy data, allowing for imaging dose reduction. However, there are a few practical concerns preventing the clinical implementation of these techniques. On the image quality side, data truncation along the superior–inferior direction under the cone-beam geometry produces severe cone artifacts in the reconstructed images. Ring artifacts are also seen in the half-fan scan mode. On the reconstruction efficiency side, the long computation time hinders clinical use in image-guided radiation therapy (IGRT). Methods: Image quality improvement methods are proposed to mitigate the cone and ring image artifacts in IR. The basic idea is to use weighting factors in the IR data fidelity term to improve projection data consistency with the reconstructed volume. In order to improve the computational efficiency, a multiple graphics processing units (GPUs)-based CS-IR system was developed. The parallelization scheme, detailed analyses of computation time at each step, their relationship with image resolution, and the acceleration factors were studied. The whole system was evaluated in various phantom and patient cases. Results: Ring artifacts can be mitigated by properly designing a weighting factor as a function of the spatial location on the detector. As for the cone artifact, without applying a correction method, it contaminated 13 out of 80 slices in a head-neck case (full-fan). Contamination was even more severe in a pelvis case under half-fan mode, where 36 out of 80 slices were affected, leading to poorer soft tissue delineation and reduced superior–inferior coverage. The proposed method effectively corrects those contaminated slices with mean intensity differences compared to FDK results decreasing from ∼497 and ∼293 HU to ∼39 and ∼27 HU for the full-fan and half-fan cases, respectively. In terms of efficiency boost, an overall 3.1 × speedup factor has been achieved with four GPU cards compared to a single GPU-based reconstruction. The total computation time is ∼30 s for typical clinical cases. Conclusions: The authors have developed a low-dose CBCT IR system for IGRT. By incorporating data consistency-based weighting factors in the IR model, cone/ring artifacts can be mitigated. A boost in computational efficiency is achieved by multi-GPU implementation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗