Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Security monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Data-Enhanced Hierarchical Control to Improve Distribution Voltage with Extremely High PV Penetration

Dynamic, scalable, and interoperable control paradigms are required to enable efficient, secure, reliable, and resilient distribution grid operations with widespread grid integration of renewable energy resources. This paper presents our recent research on developing a novel, holistic, data-enhanced hierarchical control architecture that addresses the formidable challenges faced by emerging distribution grids with increasing penetrations of distributed energy resources. The proposed architecture integrates centralized monitoring and control with distributed grid-edge control and thus effectively deals with multi-spatiotemporal dynamics existing in the grid. Simulation results are provided to demonstrate the effectiveness of the proposed control architecture.

14 SOLAR ENERGY↗

Cyber Resiliency and the Implementation of a Host-Based Intrusion Detection System in an Urban Air Mobility Environment

With the growth in Urban Air Mobility systems and the increasing reliance on interconnected technologies, ensuring the security of these complex components has become critical. As cities evolve into smart urban centers, the vulnerability to cyber threats escalates, possibly endangering citizens safety and the efficiency of transportation networks.In response to these challenges, this paper presents a study on the need for cyber resilient techniques within future air traffic environments. It will pay specific attention to the implementation of a Host-Based Intrusion Detection System (HIDS) utilizing Atomic OSSEC software, tailored specifically to a NASA simulation of an UrbanAirMobility environments’ unique demands. Further, this study seeks to outline the rational for NASA’s recommendation for a HIDS in such environments. It explores the design, development, and deployment of the proposed HIDS, focusing on its adaptability to monitor the hybrid nature of the Urban Air Mobility environment. Leveraging machine learning algorithms and anomaly detection techniques, the HIDS is equipped to continuously monitor and analyze the behavior of individual host systems, vehicles, and devices, thereby providing a proactive approach to threat detection. Implementing a HIDS is a pivotal strategy for enhancing cyber resiliency, as it gives an organization granular visibility into internal system activities, enables rapid detection and response to anomalous behavior and cyber threats, and fortifies the organizations overall cybersecurity posture. Finally, this study aims to provide recommendations and include learned takeaways that the Urban Air Mobility industry should consider. In brief, this paper highlights the significance of host-based intrusion detection in UrbanAirMobility environments and underscores the necessity of tailored security solutions to safeguard against emerging cyber threats.

UAM↗

Pioneer WEC Dashboard

SAND2026-18911O The Pioneer WEC (Wave Energy Converter) Dashboard tool visualizes real-time data from the Pioneer WEC v1 prototype, which supplies power to a mooring in the Coastal Pioneer Array. It offers up-to-date information, performance metrics, and graphical plots that enable users to monitor the prototype's efficiency. Developed using Python and Jekyll, this static website is updated daily and hosted on GitHub. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA0003525.

Michelen Strofer, Carlos [Sandia National Lab. (SN↗

NVBL (National Virtual Biotechnology Laboratory): Pandemic Monitoring and Modeling

This virtual symposium was held to highlight the impact the U.S. Department of Energy’s (DOE) National Virtual Biotechnology Laboratory (NVBL) has had utilizing the unique capabilities of the DOE to tackle the science and technology challenges associated with COVID-19, and to discuss areas in which the NVBL can have impact in the future. With perspectives from Chris Fall, Director, Office of Science, DOE, and William A. Bookless, Principal Deputy Administrator of the National Nuclear Security Administration, the event featured Presentations from lead investigators reporting progress in: Epidemiological modeling, Therapeutics, Testing, Understanding transport of the virus, and Solving issues around supply chain challenges. In addition, keynote speakers from outside the NVBL discussed the upcoming science and technology needs in computing, testing and surveillance, and vaccines. The event was aimed at the S&T community, media, and general public.

Bhaduri, Budhu↗

Solutions Network Formulation Report. The Potential Contribution of the Ocean Surface Topography Mission to the General NOAA Oil Monitoring Environment

Data collected by the OSTM could be used to provide a solution for the GNOME DST. GNOME, developed by NOAA?s Office of Response and Restoration Hazardous Materials Response Division, geospatially models oil spill trajectories using wind, current, river flow, and tidal data. Data collected by the OSTM would supply information about ocean currents and wind speeds. This Candidate Solution is in alignment with the Coastal Management, Water Management, Disaster Management, Public Health, Ecological Forecasting, and Homeland Security National Applications and will benefit society by improving the capabilities of emergency responders who evaluate an oil spill?s probable threat.

Hilbert, Kent↗

Bayesian OED for Seismic Monitoring

SAND2024-13870O The Bayesian OED (Optimal Experiment Design) for Seismic Monitoring code provides the tools to analyze and optimize seismic monitoring networks using Bayesian OED. This method designs a utility function for experiments (network designs) using network analysis and network optimization. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Catanach, Thomas↗

Materials Characterization, Prediction, and Control Project: Characterization of 316L Stainless Steel after Solid Phase Processing using Ultrasonic NDE Method

The Pacific Northwest National Laboratory undertook the Materials Characterization, Prediction, and Control Laboratory Directed Research and Development Project to advance understanding of nuclear material processing and enable multifold acceleration in the development and qualification of new material systems produced via advanced manufacturing methods, such as solid phase processing, for use in national security and advanced energy applications (Smith 2021). A motivation of the Materials Characterization, Prediction, and Control Project was to demonstrate ultrasonic testing as a nondestructive evaluation method to complement traditional destructive methods for characterizing material microstructure with emphasis on grain size determination using a method that may have future applications for real-time inline process monitoring. The objective of the work described in this report is to establish the process and an analysis method for measuring grain sizes of polycrystalline metals with ultrafine grains using ultrasonic shear wave backscattering, building on prior studies on coarser-grained material. The work involves five tasks: Measured ultrasonic backscattering experimentally for a series of 316L stainless steel specimens with various grain sizes made by friction stir processing. Calculated ultrasonic backscattering coefficients from experimental data based on a physical measurement model. Measured ground truth grain sizes of the specimens from electron backscatter diffraction grain boundary images using a generalization of the ASTM E112 (ASTM 2021) intercept method. Built a curve of ultrasonic backscattering coefficients versus the ground truth intercept-based grain sizes to determine the correlation between mean grain sizes and ultrasonic measurements. Demonstrated the ability of using the correlation curve to deduce grain sizes with measured ultrasonic backscattering coefficients for a few 316L stainless steel specimens whose grain sizes were unknown beforehand but were targeted to be an extrapolation to larger grain sizes than used to formulate the correlation curves. Experimental procedures and computational algorithms are developed and validated for these tasks. This work establishes an ultrasonic technique for characterizing material microstructure with ultrafine grains that are often resulted by solid-phase processing. The technique is nondestructive, and it has the potential to be used for real time inline process monitoring. This work successfully demonstrates the viability of an ultrasonic nondestructive evaluation method for microstructural characterization of material having ultrafine grain structure (as small as 1?mm) and produced by an advanced manufacturing method. This includes a demonstration of the method to extrapolate to other conditions. While not demonstrated here, the method is expected to be viable for in-line, or near-inline, process monitoring in advanced manufacturing applications with suitable consideration for access of instrumentation to the material being manufactured.

316 L Stainless Steel↗

Recommended Functionalities for Improving Cybersecurity of Distributed Energy Resources

The current electric grid is transitioning through increasing penetration of distributed energy resources (DERs), which include intermittent renewable generation resources on the distribution side. Both the monitoring and control of DERs require extensive data-exchange and communication networks. These networks lead to cyber vulnerabilities and risks of new kinds of cyberattacks that may be extremely destructive for power system operations. Although current standards, such as IEEE Std. 1547-2018, do not discuss cybersecurity measures for DERs, cybersecurity controls should be developed for securing DER systems at the device level, communications level, and applications level. This paper discusses the current industry's best practices related to DER cybersecurity and proposes recommended functionalities for improving the cybersecurity posture of DERs, specifically at the device/distribution level. These practical recommendations have been discussed and verified with the industry through a DER cybersecurity working group.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity for Distance Relay Protection

This project is a DOE follow-up effort on the CREDC workshop held on September 13, 2018 in Cambridge, MA to discuss cybersecurity of distance relays, which considered the benefits, vulnerabilities and risk mitigations for the use of communication systems in power system protection. The objectives of this project are to define the taxonomy of relay protection and associated communications; define use cases describing approaches to reduce the cyber-attack surface on those protective relays; and evaluate the loss of operational functional capability from changes to communication coverage. Mitigating controls will also be evaluated to understand if there are other approaches to reduce attack surfaces while maintaining communications or partial communications. Distance relays are used to protect transmission lines of approximately 10 to 300 miles in length, by detecting short circuits (i.e., faults) on the lines and then tripping circuit breakers in the substation. Such protection systems are a subset of the power system and they incorporate sensing, logic and communication functions. Protection system exposure to cyberattack could be drastically limited by disconnecting relays from all vulnerable communication systems, but this may adversely impact overall power system performance in the absence of cyberattack. This project began with a use case analysis of protection systems with communications, as summarized in this report. It continued with modeling, testing and evaluation in a miniature power system (MPS), located in the Western Area Power Administration (WAPA) Electric Power Training Center (EPTC). The project also incorporated feedback from two industry meetings held in February and September 2019. The suggested next steps account for and complement the work already underway with DOE/CESER funding: 1. Study the performance of LCD and PC vs. PUTT, which is less reliant on communication system performance and GPS timing references. The PUTT scheme could prove to be more resilient to cyberattack or communications-related disruption. It could also be more tolerant of message re-routing with SDN/SDR communication systems. On the other hand, it will be more vulnerable to false tripping during dynamic events or to loss of the voltage signal. The optimum choice of scheme may depend on the specific power system and risk assessment. This study could provide a new template for evaluation based on business functions. 2. Research and develop new methods to detect and monitor distributed physical attacks, possibly using drones, video sensors, thermal sensors, machine learning and other advanced techniques. This will help mitigate the impact of cyberattack on the protection system, and will also help mitigate the impact of wild fires. 3. Implement a scalable PKI for use in electric utility protection systems. This will encourage widespread adoption of secure authentication methods that are already available, but not widely used at present. This will help secure engineering access to the relays. 4. Investigate the use of SDN in combination with SDR to achieve better cybersecurity and electromagnetic security of the network, incorporating path variability. This would help secure both engineering access and peer-to-peer GOOSE messaging. 5. Perform additional testing, with operator evaluation of “red button” scenarios, PUTT vs. LCD, relay mis-operations, and other cyberattacks in the EPTC. This is an important advantage of testing in the EPTC rather than by computer simulation or even hardware-in-the-loop simulation; the EPTC is already dedicated to managing the situational awareness, operator response times and other human impacts. One of the project objectives was to settle on a common nomenclature for this problem space. We have concluded that the OSI layer model, supplemented by ANSI device numbers and other IEEE standards, is already well-accepted by the industry. The IEEE PSRC knowledge base provides a great deal of public information

24 POWER TRANSMISSION AND DISTRIBUTION↗

Edge at the Pier: EPCAPE Software-Defined Sensing Field Campaign Report

The Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) was aimed to enhance the understanding of cloud and aerosol properties in the region surrounding La Jolla, California. To address challenges in data collection and processing from various instruments, an edge computing device known as Waggle Sage Node (WSN) was deployed at the Ellen Browning Scripps Memorial Pier. WSN is a distributed-sensing platform designed to collect and analyze environmental data at the edge. Sage is a multi-agency-supported project that designs and builds a new kind of national-scale reusable cyberinfrastructure to enable artificial intelligence (AI) at the edge based on the Waggle platform. Sponsors include the U.S. Department of Energy (DOE) Advanced Scientific Computing Research (ASCR), DOE National Nuclear Security Administration (NNSA), DOE Biological and Environmental Research (BER) through DOE Artificial Intelligence for Earth System Predictability (AI4ESP), Argonne Laboratory-Directed Research and Development (LDRD). Sage (https://sagecontinuum.org/) is funded as a National Science Foundation Mid-Scale Research Infrastructure (MSRI) project (https://www.nsf.gov/awardsearch/showAward?AWD_ID=1935984). This robust, multi-architecture edge computing platform facilitated environmental monitoring during the campaign. This report details the scientific objectives, deployment process, and key results of integrating Waggle into the EPCAPE field campaign.

54 ENVIRONMENTAL SCIENCES↗

Livermore's Cube Satellite Evolution: Space Program Innovation: One Small Satellite at a Time

Cube satellites, called CubeSats, are a common type of nanosatellite comprising a modular framework of cube-shaped building block units that measure 10 centimeters per side. Their lower cost and ease of construction compared to large, conventional satellites have made them a popular choice for modern space applications. Lawrence Livermore’s first involvement with CubeSats began nearly a decade ago when scientists developed optical imaging payloads for the Space-Based Telescopes for the Actionable Refinement of Ephemeris project to monitor space debris. More recently, as part of a collaboration with NASA Goddard Space Flight Center, the Laboratory has helped develop the MiniCarb CubeSat for measuring atmospheric greenhouse gases. MiniCarb will be the first to use the innovative, Laboratory-developed CubeSat Next Generation Bus platform, ushering in a new era for the institution’s Space Science and Security Program.

Nanosatellite↗

Evaluating the Impact of Agricultural Soil NOx Emissions on Air Quality Using Advanced Satellite, Ground-based, and Model Data

Soil moisture can also influence the concentration of atmospheric trace gases by moderating the emission of nitrogen oxides (NOx = NO + NO2) from agricultural fields. Human activities can play an important role in controlling the available soil moisture depending on irrigation demand and agricultural management. To further complicate matters, nitrogen fertilizer use has also been found to be a significant source of NOx emissions in agricultural areas. In fact, some of the highest emissions have been reported from fertilized soils in high-temperature agricultural regions, such as the Imperial Valley of California. Since NO2 is an important precursor to ozone formation in the troposphere, which is a leading cause of premature death in humans, it is critical to understand how natural and anthropogenic factors contribute to NOx emissions in these areas. O3 pollution is also a growing threat to global food security due to its detrimental impacts on crop production. This work uses a suite of satellite, ground-based, and model data to investigate how agricultural soil NOx emissions from natural (rainfall) and anthropogenic factors (irrigation, nitrogen fertilizer) govern air quality over California. We evaluate the capabilities of using SMAP retrievals and SMAP Land Information System (LIS) output for monitoring irrigation activities over the major agricultural areas of California by conducting intensive analyses of soil moisture and precipitation data. High-resolution trace gas observations from the new generation TROPOspheric Monitoring Instrument (TROPOMI) sensor are used to characterize and monitor the variability of trace gases and air quality conditions associated with soil NOx emissions. We also synthesize satellite, ground-based, and agriculture data to estimate the separate contributions from rainfall, irrigation, and nitrogen fertilizer practices on soil NOx emissions and associated air quality conditions. Finally, unprecedented hourly trace gas retrievals from the NASA Tropospheric Emissions: Monitoring of Pollution (TEMPO) geostationary satellite sensor are used to monitor the diurnal evolution of NO2 and O3 concentrations from soil NOx emissions.

Aaron R Naeger↗

Cyber risk assessment and investment optimization using game theory and ML-based anomaly detection and mitigation for wide-area control in smart grids

The electric power grid is increasingly becoming susceptible to cyber attacks that exploit vulnerabilities in the smart grid control, information, and physical layers. Successful cyber attacks can have catastrophic impacts on the social and economic well-being of any nation all over the globe. It has, thus, become imperative to secure the smart grid against such adversarial actions to ensure stable, secure, and reliable operation of the grid. The existing research and industry practices prove to be inadequate in terms of providing pragmatic and effective defense methodologies and measures for long-term cybersecurity planning and real-time cybersecurity for grid operation. For example, existing works lack models that incorporate uncertain behavior of cyber-attackers and pragmatic defense measures for cyber risk assessment and cybersecurity investment optimization which often provide unreliable and strictly qualitative solutions to these problems. At the same time, with the growing number of cyber incidents in the grid, there still exists a need to develop attack-resilient algorithms for wide-area monitoring, protection, and control (WAMPAC) applications like the wide-area voltage control systems (WAVCS) for Flexible AC Transmissions Systems (FACTS) that lack in scalable and feasible solutions from the cybersecurity perspective. This dissertation proposes novel models and methodologies for: (1) Cybersecurity planning, and (2) Cybersecurity for system operation. The cybersecurity planning is achieved through cyber risk assessment and cybersecurity resource investment optimization for long-term cybersecurity of the grid using game theory and attack-defense trees. Cybersecurity for system operation consists of development of cyber anomaly detection and mitigation algorithms for flexible AC transmission system (FACTS) controller-based wide-area voltage control systems (WAVCS) using machine learning (ML), and software defined networking-based moving target defense network routing for achieving real-time cyber-physical security for grid operations. This is followed by hardware-in-the-loop (HIL) implementation and evaluation of these attack prevention, detection, and mitigation algorithms and methodologies showcasing their feasibility in a close to real-world environment. For cybersecurity planning, a novel approach involving a combination of game theory and attack defense trees (ADT) for optimal cybersecurity resource allocation in the smart grid is proposed. This methodology involves modeling of the cyber-physical smart grid substations as ADTs, defining attacker costs, defense costs, and attack probabilities for attack access points. Using game theoretical formulation, optimal defense strategies for the defender of the system to invest cybersecurity resources in the grid are obtained. Additionally, a game-theoretic framework is developed for quantitative cyber-physical risk assessment of the grid under a dynamically changing cyber threat space and uncertain behavior of cyber attackers which is further used to optimize investments in the smart grid's cybersecurity resources. The attacker, defender, and the smart grid system are modeled while incorporating attacker-stochasticity and federal guidelines for smart grid cybersecurity. This allows quantification of threat, vulnerabilities, and attack impact of the grid for quantitative risk assessment. The defender's budget to invest in the security resources in the grid is optimized based on the strategies leading to minimum system risk. The evaluation of the proposed solutions highlight the feasibility for practical implementation of these methodologies and algorithms in the smart grid, while taking the federal requirements and guidelines for smart grid security into consideration. For achieving cybersecurity for system operation, attack prevention, detection, and mitigation algorithms and methodologies are developed specifically for FACTS-based WAVCS. Anomaly detection and mitigation in the WAVCS are achieved using algorithms based on machine learning which involves offline training and testing of ML models with CPS datasets incorporating physics-based features that allow accurate distinction between system faults and cyber attacks. For attack prevention, a methodology based on software defined network (SDN)-based moving target defense (MTD) network routing is proposed that enables prevention of Denial of Service (DoS) type attacks on the smart grid communication system. Subsequently, these methodologies and algorithms are implemented and evaluated on an HIL testbed that allows for real-time attack prevention, detection, and mitigation of emulated cyber attacks on the WAVCS in a close to real-world environment. The results show highly accurate and efficient performance of the implemented algorithms and methodologies with the smart grid system operating within the NERC's system operation limits even in the presence of DoS and data integrity cyber attacks. This work opens up future research opportunities in other directions such as (1) Expanding cybersecurity planning methodologies to real-time cyber contingency analysis with different game formulations; and (2) Applying the cybersecurity for system operation algorithms to broader categories of wide-area control applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Passerine Bird Surveys for the Lawrence Livermore National Laboratory Site 200

Pursuant to Subcontract Number B644180 between ECORP Consulting, Inc. (ECORP) and Lawrence Livermore National Security, LLC. (LLNS) at Lawrence Livermore National Laboratory (LLNL), ECORP conducted passerine bird and waterfowl surveys at LLNL Livermore Site 200 (Site 200) during the spring and summer of 2021. While the point-count surveys were considered passerine and waterfowl surveys, other non-passerine species (e.g. raptors, doves, woodpeckers, hummingbirds) were surveyed for as well. LLNL conducts annual monitoring for nesting raptors at the Livermore Site 200. Because of this, raptors were not included as target species in this scope of work. The purpose of the surveys was to document the presence and abundance of all avian species in support of a Site-wide Environmental Impact Statement. Particular focus of the survey was on special status bird species.

54 ENVIRONMENTAL SCIENCES↗

Best Practices for Grid Communications

As the grid evolves, the communications architecture will need to evolve with it. That architecture affords a structured means by which the evolving complexities of the modern electric grid can be managed. This document provides best practices that can be implemented in the grid of today and evolve towards the grid and grid architecture of the future. The evolving grid and its control communications increasingly rely on commercial communications providers and a variety of technologies, from wireless (e.g., 5G, microwave, Wi-Fi) to wireline (fiber, copper) to radio communications (P25, other repeater-based systems), and all these communications systems rely on electric power. A reliable and resilient grid must account for this complex set of interdependencies in its planning activities, especially those involving restoration and recovery. The participation of all relevant parties in both planning and exercising of plans can prevent unexpected conditions that impede the reliable operation and recovery of the grid. Best practices for grid communications include using a Network Management System to document the operational state, define and monitor baselines, detect changes, and accelerate response to abnormalities. If transitioning from SONET to IP/packet-based systems, translating grid requirements into communications requirements for latency, bandwidth and throughput, IP packet delay variation, packet loss, and availability should inform and drive technology planning and selection as well as that communication system’s Quality of Service (QoS) policies and Service Level Agreements (SLAs). Secure and reliable timing is another key component of a reliable and resilient grid that can operate through adverse events. A trusted internal NTP configuration, an integrated and diverse timing delivery system, optimizing the timing architecture based on the transport technologies of the communications system, and using established standards can deliver the level of timing accuracy required by a range of time-sensitive power system applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Slow Scan Telemedicine

Originally developed under contract for NASA by Ball Bros. Research Corporation for acquiring visual information from lunar and planetary spacecraft, system uses standard closed circuit camera connected to a device called a scan converter, which slows the stream of images to match an audio circuit, such as a telephone line. Transmitted to its destination, the image is reconverted by another scan converter and displayed on a monitor. In addition to assist scans, technique allows transmission of x-rays, nuclear scans, ultrasonic imagery, thermograms, electrocardiograms or live views of patient. Also allows conferencing and consultation among medical centers, general practitioners, specialists and disease control centers. Commercialized by Colorado Video, Inc., major employment is in business and industry for teleconferencing, cable TV news, transmission of scientific/engineering data, security, information retrieval, insurance claim adjustment, instructional programs, and remote viewing of advertising layouts, real estate, construction sites or products.

Source record↗

Federal Facility Agreement and Consent Order: Nevada National Security Site Use Restriction Management Plan with ROTC 1

This Use Restriction Management Plan (URMP) provides the information needed to create, modify, and manage use restrictions (URs) for sites on the Nevada National Security Site (NNSS), and sites accessed through the NNSS main gate, that were closed using the corrective action alternative (CAA) of closure in place under the Federal Facility Agreement and Consent Order (FFACO) (1996, as amended). (Note: This pertains to those FFACO sites not managed by the U.S. Department of Energy [DOE], Legacy Management.) The closure in place alternative is used for sites closed with residual contamination at levels requiring corrective action as determined using the FFACO process. The URs contain and control all requirements for long-term monitoring. This URMP also serves as the single repository of the URs implemented under the FFACO that identify use restricted areas and contain the current requirements for inspections, maintenance, and monitoring of the UR. The requirements in these URs replace all requirements listed in previous documentation. This consolidates post-closure monitoring requirements into a single source that ensures completeness and consistency of UR requirements and information. Standardized UR forms were developed to clearly document post-closure requirements that are consistent with current protocols and to ensure consistent information is contained in the URs. Standard notification, summary, and site controls statements were developed for all URs with provisions to insert site-specific options in the text. Current protocols for Industrial Sites and Soils URs are defined in this document and in the Soils Risk-Based Corrective Action (RBCA) Evaluation Process (DOE/EMNV, 2018). The standardized UR forms that have been approved to date are listed in Appendix A. Additional UR forms will be added once the review and approval process has been completed.

54 ENVIRONMENTAL SCIENCES↗

Cyber-Attack Detection for Photovoltaic Farms Based on Power-Electronics-Enabled Harmonic State Space Modeling

Here in this paper, a physics-data-based detection method is proposed to detect a variety of cyber-attacks in Photovoltaic (PV) farms using the power electronics-enabled harmonic state space (HSS) models, which, to our knowledge, is original. At the device level, HSS-based detection is developed to monitor harmonic vectors of individual PV converter with minimum sensor measurements, thus improving accuracy and robustness compared to Kalman Filter-based detection. At the system level that involves multiple PV converters, a clustering approach is developed to investigate attack propagation and accurately locate attack sources within a PV farm. The proposed approach is one of the first attempts to address PV security through interaction between the device and system, maximizing the accuracy and robustness at different levels. To verify the feasibility, a comprehensive attacks model is built, including single attack, coordinated attacks, and replay attacks. Besides, the impacts of irradiance changes are taken into consideration in the test scenarios. With the real-time data acquisition and hardware-in-the-loop testbed, comprehensive test results are provided to verify the feasibility of the proposed detection methodology.

42 ENGINEERING↗