Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Scintillation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Fission signal detection using helium-4 gas fast neutron scintillation detectors

We demonstrate the unambiguous detection of the fission neutron signal produced in natural uranium during active neutron interrogation using a deuterium-deuterium fusion neutron generator and a high pressure {sup 4}He gas fast neutron scintillation detector. The energy deposition by individual neutrons is quantified, and energy discrimination is used to differentiate the induced fission neutrons from the mono-energetic interrogation neutrons. The detector can discriminate between different incident neutron energies using pulse height discrimination of the slow scintillation component of the elastic scattering interaction between a neutron and the {sup 4}He atom. Energy histograms resulting from this data show the buildup of a detected fission neutron signal at higher energies. The detector is shown here to detect a unique fission neutron signal from a natural uranium sample during active interrogation with a (d, d) neutron generator. This signal path has a direct application to the detection of shielded nuclear material in cargo and air containers. It allows for continuous interrogation and detection while greatly minimizing the potential for false alarms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillation of lead tungstate crystal studied with single-electron beam from KUFEL

Lead tungstate (PWO) crystal has a very fast response, high atomic density and high radiation hardness. Therefore, they are suitable to be used for high-energy nuclear data measurements under high-background circumstances. Although a good electron-ion separation with a pulse shape analysis technique is essential, scintillation pulse shapes have not been observed with electron beams of a wide energy range. A single-electron beam technique has been developed at Kyoto University Free Electron Laser (KUFEL), and electron beams of 4-38 MeV are available. During the experiments, single electron beams bombarded a PWO crystal. By using oscilloscope we observed scintillation pulses of a PWO crystal coupled with a photomultiplier tube. Measured spectra were compared with the simulation code of EGS5 to analyze scattering effects. As the result, the pulse amplitudes show good linearity and the pulse shapes are almost constant in the observed energy range.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Light yield quenching and quenching remediation in liquid scintillator detectors

Quenching of light emission from an LAB based scintillator by the addition of organic amines and carboxylic acids is examined. Chemical functional groups of the quenching agents play an important role in this reduction. It is shown that "salt" formation at a 1:1 mole ratio in a mixed amine-acid system, reduces quenching by a factor of ~ 2. Supporting NMR spectra are presented. Finally, this "quenching neutralization" has the potential to reduce the light loss incurred when metals complexed with quenching agents are loaded into organic scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of proton quenching in a plastic scintillator detector

The non-linear energy response of the plastic scintillator EJ-260 is measured with the MicroCHANDLER detector, using neutron beams of energy 5 to 27 MeV at the Triangle Universities Nuclear Laboratory. The first and second order Birks' constants are extracted from the data, and found to be $k_B = (8.70 \pm 0.93)\times 10^{-3}\ {\rm g/cm^2/MeV}$ and $k_C = (1.42 \pm 1.00) \times 10^{-5}\ {\rm (g/cm^2/MeV)^2}$. This result covers a unique energy range that is of direct relevance for fast neutron backgrounds in reactor inverse beta decay detectors. Furthermore, these measurements will improve the energy non-linearity modeling of plastic scintillator detectors. In particular, the updated energy response model will lead to an improvement of fast neutron modeling for detectors based on the CHANDLER reactor neutrino detector technology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Twelve-crystal prototype of Li 2 MoO 4 scintillating bolometers for CUPID and CROSS experiments

An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied depending on the size of phonon NTD-Ge sensors glued to both LMO and Ge absorbers, shape of the Ge light detectors (circular vs. square, from two suppliers), in different light collection conditions (with and without reflector, with aluminum coated LMO crystal surface). The scintillating bolometer array was operated over 8 months in the low-background conditions that allowed to probe a very low, μBq/kg, level of the LMO crystals radioactive contamination by 228 Th and 226 Ra.

47 OTHER INSTRUMENTATION↗

Research and Development of Scintillation fiber Trackers

We are developing the scintillation fiber trackers. This detector is consist of 0.5 mm diameter scintillation fibers and PPDs. This detector has the doughnut shape with outer diameter of 50 cm and inner diameter of 10 cm and thickness of 2 mm. The position resolution is 70 μm. There are no ineffective area. And the cost is several million yen. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-TeP2-08: Evaluation of Plastic Scintillator Detector for Small Field Stereotactic Patient-Specific Quality Assurance

Purpose: To evaluate the performance of a commercial plastic scintillator detector (PSD) for small-field stereotactic patient-specific quality assurance using flattening-filter-free (FFF) beams. Methods: A total of ten spherical targets (volume range:[0.03cc–2cc]) were planned using Dynamic Conformal Arc(DCA-10 plans) and Volumetric Modulated Arc Therapy(VMAT-10 plans) techniques in Eclipse(AAA v.11, 1mm dose calculation grid size). Additionally, 15 previously-treated cranial and spine SRS plans were evaluated (6 DCA, 9 VMAT, volume range:[0.04cc–119.02cc]). All measurements were acquired using Varian Edge equipped with HDMLC. Three detectors were used: PinPoint ion chamber (PTW;active volume 0.015cc), Exradin W1 PSD (Standard Imaging;active volume 0.002cc), and Gafchromic EBT3 film (Ashland). PinPoint and PSD were positioned perpendicular to beam axis in a Lucy phantom (Standard Imaging). Films were placed at isocenter in solid water. Calibration films were delivered for absolute dose analysis. Results: For large spherical targets(>1.5cc) with DCA, all detectors agreed within 1% of AAA calculations. As target volume decreased, PSD measured higher doses than AAA (maximum difference: 3.3% at 0.03cc target), while PinPoint chamber measured lower doses (maximum difference:-3.8% at 0.03cc target). Inter-detector differences between pinpoint and PSD increased with decreasing target size; differences>5% were observed for targets<0.09cc. Similar trends for inter-detector behavior were observed for clinical plans. For target sizes<0.08cc, PSD measured>5% higher dose than PinPoint chamber (maximum difference: 9.25% at 0.04cc target). Film demonstrated agreement of −0.19±1.47% with PSD for all spherical targets, and agreement within −0.98±2.25% for all 15 clinical targets. Unlike DCA, VMAT plans did not show improved AAA-to-detector agreements for large targets. Conclusion: For all targets, the PSD measurements agreed with film within 1.0%, on average. For small volume targets (<0.10cc), PSD agreed with film but measured significantly higher doses (>5%) compared with the pin point ion chamber. The plastic scintillator detector appears to be suitable for accurate measurements of small SRS targets.

60 APPLIED LIFE SCIENCES↗

Multiplicity counting using organic scintillators to distinguish neutron sources: An advanced teaching laboratory

In this advanced instructional laboratory, students explore complex detection systems and nondestructive assay techniques used in the field of nuclear physics. After setting up and calibrating a neutron detection system, students carry out timing and energy deposition analyses of radiation signals. Through the timing of prompt fission neutron signals, multiplicity counting is used to carry out a special nuclear material (SNM) nondestructive assay. Our experimental setup is comprised of eight trans-stilbene organic scintillation detectors in a well-counter configuration, and measurements are taken on a spontaneous fission source as well as two (α,n) sources. By comparing each source's measured multiplicity distribution, the resulting measurements of the (α,n) sources can be distinguished from that of the spontaneous fission source. Such comparisons prevent the spoofing, i.e., intentional imitation, of a fission source by an (α,n) neutron source. This instructional laboratory is designed for nuclear engineering and physics students interested in organic scintillators, neutron sources, and nonproliferation radiation measurement techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AMoRE: Collaboration for searches for the neutrinoless double-beta decay of the isotope of {sup 100}Mo with the aid of {sup 40}Ca{sup 100}MoO{sub 4} as a cryogenic scintillation detector

The AMoRE (Advanced Mo based Rare process Experiment) Collaboration is planning to employ {sup 40}Ca{sup 100}MoO{sub 4} single crystals as a cryogenic Scintillation detector for studying the neutrinoless double-beta decay of the isotope {sup 100}Mo. A simultaneous readout of phonon and scintillation signals is performed in order to suppress the intrinsic background. The planned sensitivity of the experiment that would employ 100 kg of {sup 40}Ca{sup 100}MoO{sub 4} over five years of data accumulation would be T{sub 1/2}{sup 0{nu}} = 3 Multiplication-Sign 10{sup 26} yr, which corresponds to values of the effective Majorana neutrino mass in the range of Left-Pointing-Angle-Bracket m{sub {nu}} Right-Pointing-Angle-Bracket {approx} 0.02-0.06 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FInal Report: First Principles Modeling of Mechanisms Underlying Scintillator Non-Proportionality

This final report presents work carried out on the project “First Principles Modeling of Mechanisms Underlying Scintillator Non-Proportionality” at Lawrence Livermore National Laboratory during 2013-2015. The scope of the work was to further the physical understanding of the microscopic mechanisms behind scintillator nonproportionality that effectively limits the achievable detector resolution. Thereby, crucial quantitative data for these processes as input to large-scale simulation codes has been provided. In particular, this project was divided into three tasks: (i) Quantum mechanical rates of non-radiative quenching, (ii) The thermodynamics of point defects and dopants, and (iii) Formation and migration of self-trapped polarons. The progress and results of each of these subtasks are detailed.

36 MATERIALS SCIENCE↗

Current status on plastic scintillators modifications

Recent developments of plastic scintillators are reviewed, from 2000 to March 2015. All examples are distributed into the main purpose, i.e. the nature of the radionuclide provided with the scope of detection of various radiation particles. The main characteristics of these newly created scintillators and their detection properties are given. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Emergence of Uranium as a Distinct Metal Center for Building Intrinsic X-ray Scintillators

The combination of high atomic number and high oxidation state in U VI materials gives rise to both high X-ray attenuation efficiency and intense green luminescence originating from ligand-to-metal charge transfer. These two features suggest that U VI materials might act as superior X-ray scintillators, but this postulate has remained substantially untested. Now the first observation of intense X-ray scintillation in a uranyl–organic framework (SCU-9) that is observable by the naked eye is reported. Combining the advantage in minimizing the non-radiative relaxation during the X-ray excitation process over those of inorganic salts of uranium, SCU-9 exhibits a very efficient X-ray to green light luminescence conversion. The luminescence intensity shows an essentially linear correlation with the received X-ray intensity, and is comparable with that of commercially available CsI:Tl. SCU-9 possesses an improved X-ray attenuation efficiency (E>20 keV) as well as enhanced radiation resistance and decreased hygroscopy compared to CsI:Tl.

Chemistry↗

Crystal growth and characterization of high performance KSr 2 Br x I 5-x :Eu scintillators

In this work we investigated the effects of replacing some of the matrix iodine atoms in KSr 2 I 5 :Eu with bromine, forming new solid solutions of KSr 2 Br x I (5-x) :Eu (where 0.05 ≤ x ≤ 1). Transparent 15 and 22mm diameter single crystals of KSr 2 Br x I (5-x) :Eu were grown via the vertical Bridgman technique using a two-zone transparent furnace. The scintillation properties of the mixed compounds were investigated and compared to the non-mixed parent compound, KSr 2 I 5 :Eu. The addition of bromine blue-shifted the x-ray excited emission from 450 to 446 nm, increased the light yield by ~11% and decreased the scintillation decay time by suppressing its secondary component (≥3 μs), while maintaining energy resolutions comparable to the reference crystal. Thermoluminescence glow curves showed that the addition of bromine modified the shallow traps located between 25 and 55 K, suggesting that these traps are responsible for lengthening KSI’s decay time. In large sizes (10.3 cm 3 ), KSr 2 Br 0.10 I 4.90 :Eu 2% had light yields up to 79,000 ph/MeV and energy resolutions as low as 3.2% at 662 keV.

36 MATERIALS SCIENCE↗

Europium concentration effects on the scintillation properties of Cs 4 SrI 6 :Eu and Cs 4 CaI 6 :Eu single crystals for use in gamma spectroscopy

Recently discovered scintillators Cs 4 SrI 6 :Eu and Cs 4 CaI 6 :Eu have shown promising properties for gamma-ray detection in homeland security applications, with <4% energy resolution (at 662 keV) and light yields above 50,000 ph/MeV. However, a thorough investigation of the effects of europium concentration has not yet been conducted. In this work, Eu 2+ concentration was varied from 0.5 mol% to 9 mol%, and Ø7 mm single crystals were grown from the melt via the vertical Bridgman method. Scintillation performance was evaluated as a function of Eu 2+ concentration to determine the optimal amount. The observed trend was improved energy resolution and higher light yield with increasing Eu 2+ concentration up to 7 mol%. The best energy resolution achieved was 3.2% for Cs 4 SrI 6 :Eu 7% and 3.6% for Cs 4 CaI 6 :Eu 7%. Their respective light yields were 71,000 ph/MeV and 69,000 ph/MeV.

36 MATERIALS SCIENCE↗

Scintillation, dosimeter and optical properties of MgF2 transparent ceramics doped with Gd3+

Highlights: • We have developed MgF{sub 2}:Gd{sup 3+} transparent ceramics by SPS. • The samples showed luminescence due to the 4f-4f transitions of Gd{sup 3+}. • The 1% Gd-doped sample has high TSL sensitivity equivalent to commercial personal dosimeters. - Abstract: In this study, we have developed MgF{sub 2}:Gd transparent ceramics by spark plasma sintering (SPS) and evaluated the scintillation, dosimeter and optical properties. All the sample were successfully synthesized in a transparent form with relative densities over 99% to that of the single crystal. The samples were confirmed to show scintillation, thermally-stimulated luminescence (TSL) and optically-stimulated luminescence (OSL). The origin of these emissions was due to the 4f-4f transitions of Gd{sup 3+} appearing as a single peak at 310 nm. In particular, the TSL was very sensitive to X-rays, and especially the 1% Gd-doped sample showed a sensitivity as low as 0.1 mGy. The TSL response increases monotonically with the irradiation dose, and the dynamic range was confirmed to be over 0.1–1000 mGy, which was equivalent sensitivity to that of commercial personal dosimeters.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimization of crystal growth and properties of γ-CuI ultrafast scintillator by the addition of LiI

Highlights: • Large and transparent γ-CuI single crystal with the size over 20 mm was successfully obtained for the first time. • The intensities of near-band-edge emissions of γ-CuI single crystal are greatly enhanced by Li and I dopants. • The 430 nm emission decay time is less than 450 ps under pulsed X-ray irradiation. - Abstract: Large-sized γ-CuI single crystals with ultrafast scintillation property were grown in LiI acetonitrile solvent through evaporation technique. The LiI exhibits unique properties to γ-CuI single crystal preparation. One is that it increases the solubility of CuI in the solvent, which gives rise to a largest-sized (23 × 14 × 2 mm{sup 3}) single crystal with the high optical transmission (over 60%) in the wavelength region of 435–800 nm. The other feature is that it acts as an effective isoelectronic dopant and improves the molar ratio of copper to iodine, which greatly enhances the near-band-edge emissions (411 and 432 nm) and suppresses the broadband emission (680 nm). The decay time of the fast emission under pulsed X-ray excitation is shorter than 450 ps. The results will give a guidance for optimizing the properties of γ-CuI single crystal as an ultrafast scintillator.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Plutonium metal vs. oxide determination with the pulse-shape-discrimination-capable plastic scintillator EJ-299-33

Neutron measurements can be used to distinguish plutonium in metal or oxide form, a capability that is of great interest in nuclear nonproliferation, treaty verification, and other applications. This paper describes measurements performed on well-characterized samples of plutonium oxide and plutonium metal using the pulse-shape-discrimination-capable plastic scintillator EJ-299-33. Results are compared to those obtained with a same-sized detector cell using the liquid scintillator EJ-309. The same optimized, digital pulse shape discrimination technique is applied to both detectors and the neutron pulse height distributions are compared. Results show that the EJ-299-33 plastics can be successfully used for plutonium measurements, where the gamma ray to neutron detection ratio is much higher than for typical radioactive sources. Results also show that EJ-299-33 detectors can be used to characterize plutonium samples, specifically to discriminate between plutonium metal and oxide.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An algorithm for charge-integration, pulse-shape discrimination and estimation of neutron/photon misclassification in organic scintillators

Organic scintillators are frequently used for measurements that require sensitivity to both photons and fast neutrons because of their pulse shape discrimination capabilities. In these measurement scenarios, particle identification is commonly handled using the charge-integration pulse shape discrimination method. This method works particularly well for high-energy depositions, but is prone to misclassification for relatively low-energy depositions. A novel algorithm has been developed for automatically performing charge-integration pulse shape discrimination in a consistent and repeatable manner. The algorithm is able to estimate the photon and neutron misclassification corresponding to the calculated discrimination parameters, and is capable of doing so using only the information measured by a single organic scintillator. This paper describes the algorithm and assesses its performance by comparing algorithm-estimated misclassification to values computed via a more traditional time-of-flight estimation. A single data set was processed using four different low-energy thresholds: 40, 60, 90, and 120 keVee. Overall, the results compared well between the two methods; in most cases, the algorithm-estimated values fell within the uncertainties of the TOF-estimated values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗