Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample Handling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Sensing and Sampling of Trace Contaminations by a Dexterous Hexrotor UAV at Nuclear Facilities - 18600

Safe and efficient cleanups are a priority for decontamination and decommissioning of nuclear facilities. The contaminations of byproducts and wastes in such nuclear facilities pose a serious problems while decommissioning, to both the operators and public. Sensing these contaminations and cleaning them is an essential part of the safety procedures. The contaminations might range from low-energy to high-energy byproducts. Sensing these byproducts would require contact based or non-contact based sensing, based on its energy levels. Byproducts such as americium, are low-energy which makes it difficult to sense and sample without contact. Therefore, the workers need to physically swab the surfaces to collect the samples of these contaminations. These tasks pose a great danger for the safety of the human workers which includes the risk to reach greater heights, exposure to the radiation and sampling the entire building. A robotic solution is much more desirable in these cases, where the worker can safely handle the contaminations from a safe area. Use of robotic technologies inside these hazardous environments ensures the safety and enhances the performance. The more suitable robotic solution for reaching great heights and covering large areas of nuclear facilities, are aerial vehicles. Multi-rotor unmanned aerial vehicle (UAV) are chosen for their ability to hover at a position and also fly around in confined spaces. Quadrotors are a common choice of multi-rotor UAVs both research and industry because of its ease to fly and commercial availability. For the applications during the cleanups we need the UAV to not only hover and fly in confined spaces, but also interact with the physical world. Despite of quadrotor's advantages, they are not a best suit as they can't interact with the physical world. The tasks involving physical interactions would require the UAV to apply arbitrary forces and torques in all six degrees of freedom (DOF). As quadrotors are under-actuated and non-holonomic in motion, they cannot exert all the required forces. At Collaborative Robotics Lab, Purdue University, we developed a novel multi-rotor UAV solution, Dexterous Hexrotor, which can exert arbitrary forces and torques in all six DOF, independently and instantaneously. This enables the UAV platform to quickly respond to the external disturbances and precisely hold its position during the mission. The Dexterous Hexrotor serves as a robotic tool for the workers to perform sensing and sampling during the cleanups. Workers can operate Dexterous Hexrotor manually and/or semi-autonomously with human intervention. Manual control requires the worker to fly the Dexterous Hexrotor using a remote control. So the workers should possess knowledge on flying the UAV and to perform physical interaction. A semiautonomous Dexterous Hexrotor requires human input to some extent and requires very less knowledge of flying. The autonomy is designed to operate in flight mode and sampling mode. In flight mode, Dexterous Hexrotor takes off from a 'safe' area, reaches the desired altitude, and fly autonomously towards a sampling point. This sampling point is the target position specified on the 2D reference map. This mode also includes navigation towards the sampling point, avoiding the obstacles in the constrained environment. After reaching a stopping point, Dexterous Hexrotor waits for the human input for a target location to swab and collect samples. The Dexterous Hexrotor is now in sampling mode and waits for the human input. The human operator selects the swabbing location through the live streaming video from onboard camera. Through visual servoing, aided by the map, the UAV will move closer towards the target position. It then transitions to the impact control scheme to perform physical interaction with the wall and collects samples. Once the sample is collected, it autonomously returns back to the takeoff position in 'safe' area for the analysis by mass spectrometry. In this paper, we majorly focus on the physical interaction strategy and the required components which enables the autonomy. Decommissioning of nuclear facilities requires decontamination inside the entire buildings. Decontamination of nuclear facilities involves sensing and sampling the huge buildings, long shafts, etc. Sampling the entire facility is not possible due to the limitation in Dexterous Hexrotor's flight time. But this can be achieved by using a swarm of Dexterous Hexrotors to cover larger areas. The onboard robotic arm can be designed based on the applications such as cleaning, applying sealants, etc. The modularity of the design allows us to switch components as per the requirements of the task. These kind of robotic solutions functioning as tools for the workers, aims to make the work environment safer and playful. (authors)

42 ENGINEERING↗

Combining compositional data sets introduces error in covariance network reconstruction

Microbial communities are diverse biological systems that include taxa from across multiple kingdoms of life. Notably, interactions between bacteria and fungi play a significant role in determining community structure. However, these statistical associations across kingdoms are more difficult to infer than intra-kingdom associations due to the nature of the data involved using standard network inference techniques. We quantify the challenges of cross-kingdom network inference from both theoretical and practical points of view using synthetic and real-world microbiome data. We detail the theoretical issue presented by combining compositional data sets drawn from the same environment, e.g. 16S and ITS sequencing of a single set of samples, and we survey common network inference techniques for their ability to handle this error. We then test these techniques for the accuracy and usefulness of their intra- and interkingdom associations by inferring networks from a set of simulated samples for which a ground-truth set of associations is known. We show that while the two methods mitigate the error of cross-kingdom inference, there is little difference between techniques for key practical applications including identification of strong correlations and identification of possible keystone taxa (i.e. hub nodes in the network). Furthermore, we identify a signature of the error caused by transkingdom network inference and demonstrate that it appears in networks constructed using real-world environmental microbiome data.

59 BASIC BIOLOGICAL SCIENCES↗

An Easy‐to‐Use Custom‐Built Cell for Neutron Powder Diffraction Studies of Rechargeable Batteries

Abstract In operando powder diffraction remains one of the most powerful tools for non‐destructive investigation of battery electrode materials. While in operando X‐ray, especially synchrotron radiation, powder diffraction is by now a routine experimental technique, in operando neutron powder diffraction is still less established. We present a new electrochemical cell for in operando neutron powder diffraction, which is, first and foremost, easy to use, but can also cycle electrode materials under electrochemical conditions close to those achieved using standard laboratory cells. The cell has been designed in multiple sizes, and high‐quality electrochemical and neutron powder diffraction data is presented for sample sizes as low as 48 mg total active material. The cell handles lithium‐ion and sodium‐ion materials equally well, with no difference in how the cell is prepared and assembled. The cell is intended to be used as sample environment at powder diffractometers at the neutron facilities MLZ, ORNL and ACNS.

25 ENERGY STORAGE↗

Powder Handling Device for Analytical Instruments

Method and system for causing a powder sample in a sample holder to undergo at least one of three motions (vibration, rotation and translation) at a selected motion frequency in order to present several views of an individual grain of the sample. One or more measurements of diffraction, fluorescence, spectroscopic interaction, transmission, absorption and/or reflection can be made on the sample, using light in a selected wavelength region.

Sarrazin, Philippe C.↗

Sample Processor for Life on Icy Worlds (SPLIce): Design and Test Results

We report the design, development, and testing of the Sample Processor for Life on Icy Worlds (SPLIce) system, a microfluidic sample processor to enable autonomous detection of signatures of life and measurements of habitability parameters in Ocean Worlds. This monolithic fluid processing-and-handling system (Figure 1; mass 0.5 kg) retrieves a 50-L-volume sample and prepares it to supply a suite of detection instruments, each with unique preparation needs. SPLIce has potential applications in orbiter missions that sample ocean plumes, such as found in Saturns icy moon Enceladus, or landed missions on the surface of icy satellites, such as Jupiters moon Europa. Answering the question Are we alone in the universe? is captivating and exceptionally challenging. Even general criteria that define life very broadly include a significant role for water [1,2]. Searches for extinct or extant life therefore prioritize locations of abundant water whether in ancient (Mars), or present (Europa and Enceladus) times. Only two previous planetary missions had onboard fluid processing: the Viking Biology Experiments [3] and Phoenixs Wet Chemistry Laboratory (WCL) [4]. SPLIce differs crucially from those systems, including its capability to process and distribute L-volume samples and the integration autonomous control of a wide range of fluidic functions, including: 1) retrieval of fluid samples from an evacuated sample chamber; 2) onboard multi-year storage of dehydrated reagents; 3) integrated pressure, pH, and conductivity measurement; 4) filtration and retention of insoluble particles for microscopy; 5) dilution or vacuum-driven concentration of samples to accommodate instrument working ranges; 6) removal of gas bubbles from sample aliquots; 7) unidirectional flow (check valves); 8) active flow-path selection (solenoid-actuated valves); 9) metered pumping in 100 nL volume increments. The SPLIce manifold, made of three thermally fused layers of precision-machined cyclo-olefin polymer, supports all fluidic components (Figure 1) and integrated microchannels (125 x 250 m). Fluid is pumped by a stepper-motor-driven pump (Lee Co.). The functionality of the integrated MEMS pressure sensor (Honeywell) and passive check valves (Figure 2) were tested in conjunction with our newly designed integral bubble traps (Figure 3) and hydrophobic membrane-based concentrator (Figure 4). The concentrator (initially tested as a standalone component) demonstrated 5-fold vacuum-evaporative concentration. Polyethylene fused bead beds (PEFBBs; 50 porosity) store drylyophilized buffers, calibrants, and fluorescent dyes, and also promote mixing of sample with calibrant, dye, or H2O. Software-controlled automated tests demonstrated successful 1) fluid delivery to each component 2) valve and pump synchronization 3) sample aliquot delivery to instrument interface ports, and 4) rehydration of vacuum-dried fluorescent dye. In Figure 5, fluorescein on PEFBBs was rehydrated for 15 min using a pump-delivered water aliquot; it is displaced as H2O enters the bottom of the channel and pushes the dye into a check valve. Ultimately, SPLIce will fluorescently label amino acids in the sample for microchip-based electrophoretic (MCE) chiral separation and detection to seek and quantify key organic bio-signatures [5]; it will also deliver sample to a microfluidic version of WCL (mWCL) to measure soluble ions and redox-active species.

Life detection↗

Combining compositional data sets introduces error in covariance network reconstruction

Microbial communities are diverse biological systems that include taxa from across multiple kingdoms of life. Notably, interactions between bacteria and fungi play a significant role in determining community structure. However, these statistical associations across kingdoms are more difficult to infer than intra-kingdom associations due to the nature of the data involved using standard network inference techniques. We quantify the challenges of cross-kingdom network inference from both theoretical and practical points of view using synthetic and real-world microbiome data. We detail the theoretical issue presented by combining compositional data sets drawn from the same environment, e.g. 16S and ITS sequencing of a single set of samples, and we survey common network inference techniques for their ability to handle this error. We then test these techniques for the accuracy and usefulness of their intra- and inter-kingdom associations by inferring networks from a set of simulated samples for which a ground-truth set of associations is known. We show that while the two methods mitigate the error of cross-kingdom inference, there is little difference between techniques for key practical applications including identification of strong correlations and identification of possible keystone taxa (i.e. hub nodes in the network). Furthermore, we identify a signature of the error caused by transkingdom network inference and demonstrate that it appears in networks constructed using real-world environmental microbiome data.

59 BASIC BIOLOGICAL SCIENCES↗

Aseptic Operations for Post DHMR Processing of MOMA Mass Spectrometer

Mars Organic Molecule Analyzer - Mass Spectrometer (MOMA-MS) is an instrument in the MOMA instrument suite for the European Space Agency (ESA) ExoMars 2020 Rover. The rover is Planetary Protection Mission Category IVb, the first IVb mission since the Viking missions in the 1970s. Within the sample path of the MOMA instrument suite, the hardware surfaces of the must be sanitized to a level of less than 0.03 spore/m sq. To meet this requirement, the MS sample path was subjected to Dry Heat Microbial Reduction (DHMR) to decrease the number of viable spores by 4 orders of magnitude from a measured 88 spores/m sq to 0.009 spores/m sq. Before DHMR, the hardware is handled using standard cleanroom practices. After DHMR, planetary protection filters protect the sample path for most of integration, but when sample path exposure is required, aseptic operations are instituted and exposure times are kept to an absolute minimum. The surface area of exposure is also taken into account to determine safe exposure times. Before work begins, the ISO class 5 aseptic workspace is cleaned and tested for surface and airborne bioburden, and all tools that will contact or be used near sample path surfaces are sterilized. During the exposure activity, sterile garments are worn, sterile gloves are changed as often as necessary, and the environment is monitored with active and passive fallout for bioburden and real time airborne particle counts. Sterile tools are handled by a two person team so that the operator touches only the tool and not the exterior surfaces of the sterilization pouch, and a sterile operating field is established as a safe place to organize tools or parts during the aseptic operations. In cases where aseptic operations are not feasible, localized DHMR is used after exposure. Any breach in the planetary protection cleanliness can necessitate repeating instrument level DHMR, which not only has significant cost and schedule implications, it also become a risk to hardware that is not rated for repeated long exposures to high temperatures.

Spacecraft Design↗

Technology for return of planetary samples

Technological requirements of a planetary return sample mission were studied. The state-of-the-art for problems unique to this class of missions was assessed and technological gaps were identified. The problem areas where significant advancement of the state-of-the-art is required are: life support for the exobiota during the return trip and within the Planetary Receiving Laboratory (PRL); biohazard assessment and control technology; and quarantine qualified handling and experimentation methods and equipment for studying the returned sample in the PRL. Concepts for solving these problems are discussed.

Source record↗

MOSAiC-Colorado State University Ice Spectrometer

This data set contains atmospheric ice nucleating particle (INP) measurements, using Colorado State University&rsquo;s (CSU) Ice Spectrometer (IS), of filter collections taken at the U.S. DOE ARM AMF2 site onboard the R/V Polarstern P-deck during the Multidisciplinary Drifting Observatory for the Study of Arctic Climate (MOSAiC) field campaign. Samples were collected from October 27, 2019 to September 24, 2020. A filter sampler was mounted approximately 15 m above ground level on a railing in proximity to (and approximately 3 m below) the Aerosol Observation System (AOS) inlet. Single-use filter units open to the atmosphere were pre-cleaned and pre-loaded with 47-mm diameter Nuclepore polycarbonate (0.2 &micro;m pore-diameter) filters. Filters were typically drawn for a three-day period, with an average volume of air filtered of 87,000 standard liters. Total volumes were calculated through recorded daily flow rates using a mass flow meter (TSI). After collection, filters were stored and transported frozen until analysis using CSU&rsquo;s IS instrument (McCluskey et al., 2018). Aerosol particles were first re-suspended in 8 mL of 0.1 &micro;m-filtered deionized (DI) water. Aliquots of each suspension, and corresponding 11-fold dilutions, were dispensed into polymerase chain reaction (PCR) trays and placed into the aluminum blocks of the IS. Samples were cooled at approximately 0.33 &deg;C min -1 and freezing detected optically with corresponding temperatures recorded. Cumulative INP concentrations were determined through calculating the number of INPs per mL of suspension (Vali, 1971) and converting to concentration per standard L of air by accounting for the proportion of liquid used and volume of air collected. All samples were corrected for the number of INPs on the average of four field blanks (cleaned, handled, transported, and analyzed in the same way without air flow). Two-tailed, 95% confidence intervals for binomial sampling are provided (Agresti and Coull, 1998). Select samples were also heat treated (95 &deg;C for 20 min) to denature and deactivate biological INPs present and digested in 10% H 2 O 2 at 95 &deg;C under UV-B for 20 min to remove any organic carbon INPs. Agresti, A, and BA Coull. 1998. "Approximate is better than &ldquo;exact&rdquo; for interval estimation of binomial proportions." American Statistics 52: 119&ndash;126. https://doi.org/10.2307/2685469 McCluskey, CS, J Ovadnevaite, M Rinaldi, J Atkinson, F Belosi, D Ceburnis, &hellip; and PJ DeMott. 2018. "Marine and Terrestrial Organic Ice-Nucleating Particles in Pristine Marine to Continentally Influenced Northeast Atlantic Air Masses." Journal of Geophysical Research: Atmospheres 123 (11): 6196&ndash;6212, https://doi.org/10.1029/2017JD028033 Vali, G. 1971. "Quantitative Evaluation of Experimental Results and the Heterogeneous Freezing Nucleation of Supercooled Liquids." Journal of the Atmospheric Sciences 28: 402-209. https://doi.org/10.1175/1520-0469(1971)028<0402:QEOERA>2.0.CO;2

54 ENVIRONMENTAL SCIENCES↗

Plasma-Based Elemental Analyzer for Crewed Transit and Planetary Habitation

As NASA continues to perform research on the ISS and move towards the Moon and Mars, it is important for astronauts to have a technology capable of determining the composition of solid, liquid, and gas samples. Currently, samples are transported back to Earth for analysis, which may impact results due to the time delay of samples waiting to be returned to Earth as well as potential sample contamination from re-entry, change in environment, and various personnel handling. Therefore, researchers at the Applied Chemistry Lab at KSC have developed a proof-of-concept “Plasma-Based Elemental Analyzer,” which has the capability of testing solid, liquid, and gas samples for identification. Currently, the analysis is only qualitative, with quantitative identification left for future work. This technology is similar to ICP-OES, but differs in instrument size and sample preparation. Both technologies use plasma to ionize samples for light emission. The plasma elemental analyzer aims to be portable and lightweight, require only electrical power, and analyze solid, liquid, and gas samples. It does not use acid digestion or a nebulizer, requires less power than ICP-OES, and is able to operate with minimal to no usage of argon gas. Furthermore, the plasma elemental analyzer operates within low power constraints, which makes it feasible for usage on future missions with higher power constraints. The technology was tested at atmospheric pressure using mostly room air as the carrier gas for plasma production in the proof-of-concept study. The results showed the peak signals of the elements with an associated arbitrary signal intensity that allowed for qualitative identification. Solid samples that were tested included inedible biomass from the Golden Heirloom Cherry Tomato plant and Lunar Highlands Simulants (LHS-1). The liquid samples included elements of interest for the space crop production community. This work showed that a system smaller than the traditional ICP-OES equipment is able to be designed and implemented in future use cases, although it requires further development.

Kenneth Engeling↗

Spacecraft thermal control coatings

The Experiment AO 138-6 was located on the trailing edge of the Long Duration Exposure Facility as part of the French Cooperative Payload (FRECOPA) Experiment. It was purely passive in nature: material specimens 2 x 2 cm, independently mounted in sample-holders, with their surface in the same reference plane, were exposed to space. Thirty samples were set in a vacuum-tight canister which was opened in space a few days after LDEF deployment and closed while still in orbit ten months later; twenty-four samples were directly exposed to space for the total flight duration (preflight handling, shuttle bay environment, separation from shuttle, shuttle environment, LEO environment, docking, descent, transfer to KSC). Materials included paints (conductive or nonconductive), SSM's, polymeric films, surface coatings, composite materials, and metals. After sample retrieving, inspection and measurements were carried out in atmospheric laboratory conditions on each sample: observation with binocular lenses and scanning electron microscopy, spectral relectance and transmittance using an integrating sphere in the wavelength range 280-2300 nm, emissivity by the means of a Gier & Dunkle portable reflectometer, electron spectroscopy for chemical analysis-x-ray photoelectron spectroscopy (ESCA-XPS), and Rutherford backscattering spectroscopy (RBS) measurements on some selected samples. The results obtained from flight were compared to laboratory data obtained in UV-irradiation tests when these data were available. As a general statement a good spectral concordance is observed for all samples not in the canister so long as air recoveries are taken into account. For one material, the degradation is more important for the sample in the canister than for those of the same material mounted at the surface of the tray; for most samples in the canister the degradation is slightly higher than the one which can be predicted from laboratory standard irradiations. Contamination problems having been ruled out, the higher temperature experience by the samples on the inside of canister probably explains these phenomena.

Guillaumon, Jean-Claude↗

SPAR data handling utilities

The SPAR computer software system is a collection of processors that perform particular steps in the finite-element structural analysis procedure. The data generated by each processor are stored on a data base complex residing on an auxiliary storage device, and these data are then used by subsequent processors. The SPAR data handling utilities use routines to transfer data between the processors and the data base complex. A detailed description of the data base complex organization is presented. A discussion of how these SPAR data handling utilities are used in an application program to perform desired user functions is given with the steps necessary to convert an existing program to a SPAR processor by incorporating these utilities. Finally, a sample SPAR processor is included to illustrate the use of the data handling utilities.

Giles, G. L.↗

Miniature Piezoelectric Shaker Mechanism for Autonomous Distribution of Unconsolidated Sample to Instrument Cells

To perform in-situ measurements on Mars or other planetary bodies many instruments require powder produced using some sampling technique (drilling/coring) or sample processing technique (core crushing) to be placed in measurement cells. This usually requires filling a small sample cell using an inlet funnel. In order to minimize cross contamination with future samples and ensure the sample is transferred from the funnel to the test cell with minimal residual powder the funnel is shaken. The shaking assists gravity by fluidizing the powder and restoring flow of the material. In order to counter cross contamination or potential clogging due to settling during autonomous handling a piezoelectric shaking mechanism was designed for the deposition of sample fines in instrument inlet funnels. This device was designed to be lightweight, consume low power and demonstrated to be a resilient solid state actuator that can be mechanically and electrically tuned to shake the inlet funnel. In the final design configuration tested under nominal Mars Ambient conditions the funnel mechanism is driven by three symmetrically mounted piezoelectric flexure actuators that are out of the funnel support load path. The frequency of the actuation can be electrically controlled and monitored and mechanically tuned by the addition of tuning mass on the free end of the actuator. Unlike conventional electromagnetic motors these devices are solid state and can be designed with no macroscopically moving parts. This paper will discuss the design and testing results of these shaking mechanisms.

powder movement↗

Sample Preparation Methods for Targeted Single-Cell Proteomics

We compared three cell isolation and two proteomic sample preparation methods for single-cell and near-single-cell analysis. Whole blood was used to quantify hemoglobin (Hb) and glycated-Hb (gly-Hb) in erythrocytes using targeted mass spectrometry and stable isotope-labeled standard peptides. Each method differed in cell isolation and sample preparation as follows: 1) FACS and automated preparation in one-pot for trace samples (autoPOTS); 2) limited dilution via microscopy and a novel rapid one-pot sample preparation method that circumvented the need for the solid-phase extraction, low-volume liquid handling instrumentation and humidified incubation chamber; and 3) CellenONE-based cell isolation and the same one-pot sample preparation method used for limited dilution. Only the CellenONE device routinely isolated single-cells from which Hb was measured to be 540–660 amol per red blood cell (RBC), which was comparable to the calculated SI reference range for mean corpuscular hemoglobin (390–540 amol/RBC). FACSAria sorter and limited dilution could routinely isolate single-digit cell numbers, to reliably quantify CMV-Hb heterogeneity. Finally, we observed that repeated measures, using 5–25 RBCs obtained from N = 10 blood donors, could be used as an alternative and more efficient strategy than single RBC analysis to measure protein heterogeneity, which revealed multimodal distribution, unique for each individual.

59 BASIC BIOLOGICAL SCIENCES↗

An approximate Riemann solver for real gas parabolized Navier-Stokes equations

Under specific assumptions, parabolized Navier-Stokes equations are a suitable mean to study channel flows. A special case is that of high pressure flow of real gases in cooling channels where large crosswise gradients of thermophysical properties occur. To solve the parabolized Navier-Stokes equations by a space marching approach, the hyperbolicity of the system of governing equations is obtained, even for very low Mach number flow, by recasting equations such that the streamwise pressure gradient is considered as a source term. For this system of equations an approximate Roe's Riemann solver is developed as the core of a Godunov type finite volume algorithm. The properties of the approximated Riemann solver, which is a modification of Roe's Riemann solver for the parabolized Navier-Stokes equations, are presented and discussed with emphasis given to its original features introduced to handle fluids governed by a generic real gas EoS. Sample solutions are obtained for low Mach number high compressible flows of transcritical methane, heated in straight long channels, to prove the solver ability to describe flows dominated by complex thermodynamic phenomena.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Inference of experimental radial impurity transport on Alcator C-Mod: Bayesian parameter estimation and model selection

We present a fully Bayesian approach for the inference of radial profiles of impurity transport coefficients and compare its results to neoclassical, gyrofluid and gyrokinetic modeling. Using nested sampling, the Bayesian Impurity Transport InferencE (BITE) framework can handle complex parameter spaces with multiple possible solutions, offering great advantages in interpretative power and reliability with respect to previously demonstrated methods. BITE employs a forward model based on the pySTRAHL package, built on the success of the well-known STRAHL code [Dux, IPP Report, 2004], to simulate impurity transport in magnetically-confined plasmas. In this paper, we focus on calcium (Ca, Z=20) Laser Blow-Off injections into Alcator C-Mod plasmas. Multiple Ca atomic lines are diagnosed via high-resolution X-ray Imaging Crystal Spectroscopy and Vacuum Ultra-Violet measurements. We analyze a sawtoothing I-mode discharge for which neoclassical and turbulent (quasilinear and nonlinear) predictions are also obtained. Here, we find good agreement in diffusion across the entire radial extent, while turbulent convection and density profile peaking are estimated to be larger in experiment than suggested by theory. Efforts and challenges associated with the inference of experimental pedestal impurity transport are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Glycolate Analysis in Tank 22: Developing and Testing Analytical Methods for the Savannah River Site Liquid Waste System

Researchers developed and tested a range of techniques to support a low mg/L Limit of Quantitation (LOQ) of glycolate in radioactive Tank 22 waste solution by Ion Chromatography (IC) and by proton NMR. For the IC method, Dionex OnGuard II cartridges were tested as a means of removing alkali earth and transition metals that can interfere during ion chromatography applications especially when analyzing for low-concentration, chelating analytes. Additionally, concentrations of nitrate in the raw Tank 22 sample (5,000 to 10,000 mg/L) were managed by using reasonable levels of sample dilution. The resulting IC performance quality was enhanced by improving the baseline, increasing sensitivity [Limit of Quantitation (LOQ) of 12 mg/L and Limit of Detection (LOD) of 4.0 mg/L], and resolving analytes into well-defined Gaussian peaks when using the Dionex OnGuard II H⁺ cartridges to remove matrix interferences. High concentrations of nitrate limited the performance of the IC method. To achieve an acceptable baseline, samples with high nitrate content require more dilution, resulting in higher detection limits. Tests on samples with higher concentrations of nitrate (Tank 30 and 32 supernate with approximately 150000 mg/L nitrate) suggested that IC detection limits for glycolate in these samples would be > 500 mg/L. Thus, an LOQ of 12 mg/L is not feasible by this IC method on evaporator feed samples. An alternative method of glycolate analysis, using proton nuclear magnetic resonance (H NMR), was developed by the research team. In initial tests, the H NMR technique provided reasonable quantitation of glycolate in Tank 22 conditions by direct observation of the liquid. The H NMR method may provide improved detection limits for solutions with higher nitrate concentrations. We recommend further development of this analysis for high nitrate LWS samples such as evaporator feed and evaporator drop tank content. A method for pretreatment of samples using crystalline silicotitanate (CST) was developed and tested. The objective of the pretreatment was to facilitate analysis of samples with higher levels of radioactivity. The pretreatment did not influence the glycolate concentration in solution, and the pretreatment is projected to reduce Cs 137 activity in a sample by a factor of 16,200. The double strike CST pretreatment was demonstrated and would allow milliliters of higher activity samples to be transferred from the Shielded Cells and handled in a containment unit for glycolate analysis. The various studies validated IC and H NMR methods for glycolate analysis, defined the range of applicability, and demonstrated key supporting analytical protocols. Based on the results, high quality glycolate analysis of Tank 22 is feasible down to approximately 12 mg/L, with the potential for broader applicability of the methods to other conditions in the Savannah River Site Liquid Waste System (LWS).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Inference of Experimental Radial Impurity Transport on Alcator C-Mod: Bayesian Parameter Estimation and Model Selection.

We present a fully Bayesian approach for the inference of radial profiles of impurity transport coefficients and compare its results to neoclassical, gyrofluid and gyrokinetic modeling. Using nested sampling, the Bayesian Impurity Transport InferencE (BITE) framework can handle complex parameter spaces with multiple possible solutions, offering great advantages in interpretative power and reliability with respect to previously demonstrated methods. BITE employs a forward model based on the pySTRAHL package, built on the success of the well-known STRAHL code [Dux, IPP Report, 2004], to simulate impurity transport in magnetically-confined plasmas. In this paper, we focus on calcium (Ca, Z=20) Laser Blow-Off injections into Alcator C-Mod plasmas. Multiple Ca atomic lines are diagnosed via high-resolution X-ray Imaging Crystal Spectroscopy and Vacuum Ultra-Violet measurements. We analyze a sawtoothing I-mode discharge for which neoclassical and turbulent (quasilinear and nonlinear) predictions are also obtained. We find good agreement in diffusion across the entire radial extent, while turbulent convection and density profile peaking are estimated to be larger in experiment than suggested by theory. Efforts and challenges associated with the inference of experimental pedestal impurity transport are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗