Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Rapid fusion method for the determination of refractory thorium and uranium isotopes in soil samples

Recently, approximately 80% of participating laboratories failed to accurately determine uranium isotopes in soil samples in the U.S Department of Energy Mixed Analyte Performance Evaluation Program (MAPEP) Session 30, due to incomplete dissolution of refractory particles in the samples. Failing laboratories employed acid dissolution methods, including hydrofluoric acid, to recover uranium from the soil matrix. The failures illustrate the importance of rugged soil dissolution methods for the accurate measurement of analytes in the sample matrix. A new rapid fusion method has been developed by the Savannah River National Laboratory (SRNL) to prepare 1-2 g soil sample aliquots very quickly, with total dissolution of refractory particles. Soil samples are fused with sodium hydroxide at 600 ºC in zirconium crucibles to enable complete dissolution of the sample. Uranium and thorium are separated on stacked TEVA and TRU extraction chromatographic resin cartridges, prior to isotopic measurements by alpha spectrometry on cerium fluoride microprecipitation sources. Plutonium can also be separated and measured using this method. Batches of 12 samples can be prepared for measurement in <5 hours.

54 ENVIRONMENTAL SCIENCES↗

Improved sampling technique to collect natural gas from hydrate-bearing pressure cores

High quality gas compositional data are an important factor in interpreting the genetic source of natural gas hosted in hydrate-bearing sediments and other subsurface systems. In order to accurately characterize the composition of gas samples degassed from hydrate-bearing pressure cores, one must use a reproducible sampling technique that minimizes artifacts of the sampling process. Herein, we review sediment core degassing techniques and compare data obtained from a commonly used degassing approach, which we term the standard quantitative degassing (SQD) technique, to our newly developed modified quantitative degassing (MQD) method designed to minimize atmospheric contamination and gas-water interactions. The SQD method allows sample gas to interact with water in a bubbling chamber, which we hypothesize could alter the gas composition following mixing with water or dissolved gases in the bubbling chamber. Whereas, the MQD method allows for the collection of sample gas prior to the bubbling chamber. To compare the SQD and MQD methods, we performed a side-by-side comparison of noble (He, Ne, Ar, Kr, and Xe), major (H 2 , N 2 , O 2 , and CO 2 ), and hydrocarbon (CH 4 , C 2 H 6 , C 3 H 8 , i-C 4 H 10 , C 4 H 10 , i-C 5 H 12 , C 5 H 12 ) gas concentrations and select isotopic compositions obtained using both sample collection techniques. Gas samples were collected from hydrate-bearing pressure cores recovered and maintained under hydrate stable conditions from the northern Gulf of Mexico during the UT-GOM 2 -1 Expedition. The MQD method displayed significantly lower concentrations of atmospheric gases, higher proportions of hydrocarbon gases, lower ratios of C 1 /C 2 + , and heavier stable carbon and hydrogen isotopes of methane than the SQD method. These results demonstrate that the MQD method reduced air contamination and minimized alteration of the hydrocarbon gases. Finally, we conclude this method may be important for future work that seeks to determine the composition of natural gas from pressure cores using quantitative degassing experiments, especially those seeking to measure major (e.g., N 2 ) and noble gases.

58 GEOSCIENCES↗

Moving your laboratories to the field – Advantages and limitations of the use of field portable instruments in environmental sample analysis

The recent rapid progress in technology of field portable instruments has increased their applications in environmental sample analysis. These instruments offer a possibility of cost-effective, non-destructive, real-time, direct, on-site measurements of a wide range of both inorganic and organic analytes in gaseous, liquid and solid samples. Some of them do not require the use of reagents and do not produce any analytical waste. All these features contribute to the greenness of field portable techniques. Several stationary analytical instruments have their portable versions. The most popular ones include: gas chromatographs with different detectors (mass spectrometer (MS), flame ionization detector, photoionization detector), ultraviolet–visible and near-infrared spectrophotometers, X-ray fluorescence spectrometers, ion mobility spectrometers, electronic noses and electronic tongues. The use of portable instruments in environmental sample analysis gives a possibility of on-site screening and a subsequent selection of samples for routine laboratory analyses. They are also very useful in situations that require an emergency response and for process monitoring applications. However, quantification of results is still problematic in many cases. The other disadvantages include: higher detection limits and lower sensitivity than these obtained in laboratory conditions, a strong influence of environmental factors on the instrument performance and a high possibility of sample contamination in the field. This paper reviews recent applications of field portable instruments in environmental sample analysis and discusses their analytical capabilities. - Highlights: • Field portable instruments are widely used in environmental sample analysis. • Field portable instruments are indispensable for analysis in emergency response. • Miniaturization of field portable instruments reduces resource consumption. • In situ analysis is in agreement with green analytical chemistry principles. • Performance requirements in field analysis stimulate technological progress.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Parametric models for samples of random functions

A new class of parametric models, referred to as sample parametric models, is developed for random elements that match sample rather than the first two moments and/or other global properties of these elements. The models can be used to characterize, e.g., material properties at small scale in which case their samples represent microstructures of material specimens selected at random from a population. The samples of the proposed models are elements of finite-dimensional vector spaces spanned by samples, eigenfunctions of Karhunen–Loève (KL) representations, or modes of singular value decompositions (SVDs). The implementation of sample parametric models requires knowledge of the probability laws of target random elements. Numerical examples including stochastic processes and random fields are used to demonstrate the construction of sample parametric models, assess their accuracy, and illustrate how these models can be used to solve efficiently stochastic equations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

LAB4D: A low power, multi-GSa/s, transient digitizer with sampling timebase trimming capabilities

The LAB4D is a new application-specific integrated circuit (ASIC) of the Large Analog Bandwidth Recorder and Digitizer with Ordered Readout (LABRADOR) family, for use in direct wideband radio frequency digitization such as is used in ultrahigh energy neutrino and cosmic ray astrophysics. The LAB4D is a single channel switched-capacitor array (SCA) 12-bit sampler with integrated analog-to-digital converters (ADC), developed in the TSMC 0.25um process. The LAB4D, operating at 3.2GSa/s, contains 4096 total samples arranged in 32 windows, for a total record length of 1280ns. The 3dB bandwidth is approximately 1.3GHz, with a directly-coupled 50ohm input. This represents a factor of 16 increase in the sample depth and an increase in analog bandwidth and sampling depth in comparison to the previous generation LAB3 digitizer. Individually addressable windows allow for sampling and digitization to occur simultaneously, leading to nearly deadtime-free readout for kHz readout rates. All biases and current references are generated via internal digital-to-analog converters (DACs), resulting in a stand-alone digitizer with no additional support circuitry. In addition, the LAB4D contains sample cell timebase trimming capabilities, reducing the intrinsic sample-to-sample time variance to less than 5ps; an improvement of about 80%. This allows the LAB4D to be used in precision timing applications with minimal post-hoc calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An interface for the direct coupling of small liquid samples to AMS

We describe the moving wire interface attached to the 1-MV AMS system at LLNL’s Center for Accelerator Mass Spectrometry for the analysis of nonvolatile liquid samples as either discrete drops or from the direct output of biochemical separatory instrumentation, such as high-performance liquid chromatography (HPLC). Discrete samples containing at least a few 10 s of nanograms of carbon and as little as 50 zmol 14 C can be measured with a 3–5% precision in a few minutes. The dynamic range of our system spans approximately 3 orders in magnitude. Sample to sample memory is minimized by the use of fresh targets for each discrete sample or by minimizing the amount of carbon present in a peak generated by an HPLC containing a significant amount of 14 C. As a result, liquid sample AMS provides a new technology to expand our biomedical AMS program by enabling the capability to measure low-level biochemicals in extremely small samples that would otherwise be inaccessible.

14C↗

Microbiomes of frozen blood plasma samples reveal potential pathogens in wild birds and rodents

The lack of genomic data on pathogens from wildlife severely limits our ability to track transmission patterns and trace the origins of an outbreak. There are currently millions of wildlife samples in biobanks around the world, including blood samples. Blood has traditionally been viewed as a sterile environment in healthy individuals, but recent evidence suggests that this is not the case, especially for wild animals. Our goal was to determine whether frozen plasma samples can be surveyed using 16S sequencing to provide information about potential hosts for pathogens for a more complete understanding of disease systems. We sequenced blood plasma from wild North American deer mice ( Peromyscus maniculatus ) and American kestrels ( Falco sparverius ) that were cryogenically stored for 7 and 13 years, respectively, and compared two DNA extraction kits. The kestrel samples contained a very high number of reads that could not be identified to phylum compared to the mouse samples. The two kits differed in the phyla and genera that were detected, and the Zymo kit, which is optimized for plasma and serum, produced more high-quality reads for both kestrel and mouse samples. We identified several pathogenic genera, including Mycoplasma, Escherichia-Shigella , and Bartonella . Sequencing blood samples for pathogens could potentially have broad applications for identifying important reservoir hosts for pathogen transmission and provide a reduced set of species on which to follow up.

59 BASIC BIOLOGICAL SCIENCES↗

POF-Darts: Geometric adaptive sampling for probability of failure

We introduce a novel technique, POF-Darts, to estimate the Probability Of Failure based on random disk-packing in the uncertain parameter space. POF-Darts uses hyperplane sampling to explore the unexplored part of the uncertain space. We use the function evaluation at a sample point to determine whether it belongs to failure or non-failure regions, and surround it with a protection sphere region to avoid clustering. We decompose the domain into Voronoi cells around the function evaluations as seeds and choose the radius of the protection sphere depending on the local Lipschitz continuity. As sampling proceeds, regions uncovered with spheres will shrink, improving the estimation accuracy. After exhausting the function evaluation budget, we build a surrogate model using the function evaluations associated with the sample points and estimate the probability of failure by exhaustive sampling of that surrogate. In comparison to other similar methods, our algorithm has the advantages of decoupling the sampling step from the surrogate construction one, the ability to reach target POF values with fewer samples, and the capability of estimating the number and locations of disconnected failure regions, not just the POF value. Furthermore, we present various examples to demonstrate the efficiency of our novel approach.

97 MATHEMATICS AND COMPUTING↗

Field Degassing as a New Sampling Method for 14 C Analyses in Old Groundwater

Radiocarbon ( 14 C) activity in groundwater can be used to determine subsurface residence time up to ~40 kyr, providing crucial information on dynamic properties of groundwater and on paleoclimate. However, commonly applied sampling methods for dissolved inorganic carbon (DIC- 14 C) are prone to low level of modern atmospheric contamination, resulting in underestimation of groundwater ages that cluster around 30–40 kyr. We extract CO 2 gas from groundwater using a device originally developed for studies of noble gas radionuclides. Carbon is collected in the gas phase, eliminating the possibility of fostering microbial activities and aqueous chemical reactions during sample storage. This method collects CO 2 - 14 C and radiokrypton ( 81 Kr and 85 Kr) samples simultaneously. The presence of any shorter-lived 85 Kr is used to evaluate the degree of atmospheric contamination during sampling or mixing of young groundwater. Most groundwater samples showed lower CO 2 - 14 C activities than those of DIC- 14 C, presumably due to the absence of atmospheric contamination. Samples with 81 Kr age exceeding 150 kyr have no detectable CO 2 - 14 C except where mixing sources of young groundwater is suspected. Furthermore these field data serve as confirmations for the reliability of the newly presented sample collection and CO 2 - 14 C method, and for the outstanding roles of radiokrypton isotopes in characterizing old groundwater.

54 ENVIRONMENTAL SCIENCES↗

Permutationally Invariant Networks for Enhanced Sampling (PINES): Discovery of Multimolecular and Solvent-Inclusive Collective Variables

The typically rugged nature of molecular free energy landscapes can frustrate efficient sampling of the thermodynamically relevant phase space due to the presence of high free energy barriers. Enhanced sampling techniques can improve phase space exploration by accelerating sampling along particular collective variables (CVs). A number of techniques exist for data-driven discovery of CVs parameterizing the important large scale motions of the system. A challenge to CV discovery is learning CVs invariant to symmetries of the molecular system, frequently rigid translation, rigid rotation, and permutational relabeling of identical particles. Of these, permutational invariance has proved a persistent challenge in frustrating the data-driven discovery of multi-molecular CVs in systems of self-assembling particles and solvent-inclusive CVs for solvated systems. In this work, we integrate Permutation Invariant Vector (PIV) featurizations with autoencoding neural networks to learn nonlinear CVs invariant to translation, rotation, and permutation, and perform interleaved rounds of CV discovery and enhanced sampling to iteratively expand sampling of configurational phase space and obtain converged CVs and free energy landscapes. Here, we demonstrate the Permutationally Invariant Network for Enhanced Sampling (PINES) approach in applications to the self-assembly of a 13-atom Argon cluster, association/dissociation of a NaCl ion pair in water, and hydrophobic collapse of a C 45 H 92 n-pentatetracontane polymer chain. We make the approach freely available as a new module within the PLUMED2 enhanced sampling libraries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Opening doors to physical sample tracking and attribution in Earth and environmental sciences

Physical samples and their associated data and metadata underpin scientific discoveries across disciplines and can enable new science when appropriately archived. However, there are significant gaps in current practices and infrastructure that prevent accurate provenance tracking, reproducibility, and attribution. For most samples, descriptive metadata are often sparse, inaccessible, or absent. Samples and associated data and metadata may also be scattered across numerous physical collections, data repositories, laboratories, data files, and papers with no clear linkage or provenance tracking as new information is generated over time. The Earth Science Information Partners (ESIP) Physical Samples Curation Cluster has therefore developed guidance for scientific authors on ‘Publishing Open Research Using Physical Samples.’ This involved synthesizing existing practices, gathering community feedback, and assessing real-world examples. We identified improvements needed to enable authors to efficiently cite and link Earth science samples and related data, and track their use. Our goal is to help improve discoverability, interoperability, and reuse of physical samples, and associated data and metadata. Though primarily focused on the needs of Earth and environmental sciences, these guidelines are broadly applicable.

58 GEOSCIENCES↗

A Separation Voltage Polarity Switching Method for Higher Sample Loading Capacity and Better Separation Resolution in Transient Capillary Isotachophoresis Separation

A separation voltage polarity switching transient capillary isotachophoresis (PS-tCITP) was developed to overcome a major sample loading volume limitation in transient capillary isotachophoresis (tCITP). The fundamental idea of PS-tCITP is to let sample ions move back and forth in the separation capillary during their initial isotachophoresis focusing stage by switching the polarity of separation voltage, in order to both increase the sample loading volume and improve the separation efficiency as compared to the conventional tCITP method. The experimental evaluation of the novel PS-tCITP method by using two peptide standards at 2 µM concentration showed that the maximum sample loading volume could be increased from 45% of the total separation capillary volume in tCITP to 70% in PS-tCITP, which resulted in a more than 1.5 fold increases in the peptide peak intensity at a given length/volume of the separation capillary. Due to the consecutive focusing of sample volume from each polarity switching of separation voltage, the separation time window at a given sample loading volume was also increased significantly in PS-tCITP as compared to tCITP. Experiment comparison between tCITP and PS-tCITP at 45% sample loading volume using the same setup showed that the migration time difference between the two peptide peaks increased from 0.3 min in tCITP to 0.363 min in PS-tCITP with similar peak widths and heights, resulting in roughly a 21% improvement in separation resolution. The performance advantages of PS-tCITP separation over tCITP separation was further verified by using a mixture of six peptide standards.

Wu, Huanming↗

ZTF-SEDm Type Ia supernova sample for Twins Embedding spectrophotometric standardization

Aims. This paper has two aims: the first aim is to build a large homogeneous spectrophotometric sample of Type Ia supernovae (SNe Ia) from the second data release of the Zwicky Transient Facility (ZTF DR2). We used the spectrum sample from the low-resolution ( R ∼ 100) SEDmachine (SEDm) Integral Field Spectrograph (IFS) that gathered 3069 spectra. This is one of the largest samples of such collections that can attempt to reproduce the Twins Embedding (TE) spectrophotometric standardization method. This is our second objective. The method was developed based on high-quality spectra from 200 SNe Ia of the Nearby Supernova factory (SNfactory) and led to an exceptionally low value of 0.073 mag for the intrinsic scatter. Methods. As the SEDm is not designed as a spectrophotometric instrument, we first improved the flux-calibration accuracy of the SN Ia spectrum sample using the ZTF photometric data, which were calibrated at the percent level. We corrected the spectra for second-order polynomials, fitted by comparing the synthetic photometry in the ZTF g , r , i filters with the light-curve (LC) data. We then applied the three steps of the TE parameterization to a subset of 783 ZTF SN spectra near maximum light while comparing results from SNfactory and ZTF. We finally analyzed the standardization methods based on the TE parameters. Results. The precision of the phase-correction model, which is the first step of the TE, is estimated at 0.01 mag in g band based on ZTF data. Despite the challenge posed by the spectrum-extraction pipeline associated with the SEDm (flux calibration, leftover host signal, low signal-to-noise ratio, and low resolution), we applied a first standardization in color based on the second step of the TE, called read between the lines (RBTL), to the ZTF sample. We reached a Hubble residual scatter of 0.153 mag, all in normalized median absolute deviation, which is to be compared to the ∼0.11 mag obtained with the SNfactory data. The SALT color and stretch standardization reaches a scatter of 0.164 mag for the same ZTF SN Ia sample, and its host steps are ∼0.1 mag and zero for RBTL. When considering the scatter due to the redshift error and flux calibration error, we estimated a RBTL scatter of ∼0.129 mag for this ZTF sample as an upper limit because we identified an additional contribution from a systematic error in color. We tested the standardization based on the nonlinear TE parameters, and, as expected from the low spectrum quality, it did not improve the overall dispersion. Conclusions. We release 1897 flux calibrated spectra of 1607 SNe Ia with an estimated photometric accuracy of 0.07 mag. We further demonstrate that some amount of spectrophotometric SN Ia standardization can be done with limited-quality spectra. The RBTL standardization is more efficient than that of SALT with one parameter less, and the resulting host steps are consistent with zero. This makes it less prone to astrophysical bias. For future spectroscopic surveys, targeting the extraction pipeline for a thorough flux calibration and good signal-to-noise ratio would enable us to compute the full TE standardization, which would further reduce the scatter in the distance estimate.

Ganot, C↗

Microplasma source for optogalvanic spectroscopy of nanogram samples

The demand for analysis of smaller samples in isotopic ratio measurements of rare isotopes is continuously rising with the development of new applications, particularly in biomedicine. Interesting in this aspect are methods based on optogalvanic spectroscopy, which have been reported to facilitate both {sup 13}C-to-{sup 12}C and {sup 14}C-to-{sup 12}C ratio measurements with high sensitivity. These methods also facilitate analysis of very small samples, down to the microgram range, which makes them very competitive to other technologies, e.g., accelerator mass spectroscopy. However, there exists a demand for moving beyond the microgram range, especially from regenerative medicine, where samples consist of, e.g., DNA, and, hence, the total sample amount is extremely small. Making optogalvanic spectroscopy of carbon isotopes applicable to such small samples, requires miniaturization of the key component of the system, namely the plasma source, in which the sample is ionized before analysis. In this paper, a novel design of such a microplasma source based on a stripline split-ring resonator is presented and evaluated in a basic optogalvanic spectrometer. The investigations focus on the capability of the plasma source to measure the optogalvanic signal in general, and the effect of different system and device specific parameters on the amplitude and stability of the optogalvanic signal in particular. Different sources of noise and instabilities are identified, and methods of mitigating these issues are discussed. Finally, the ability of the cell to handle analysis of samples down to the nanogram range is investigated, pinpointing the great prospects of stripline split-ring resonators in optogalvanic spectroscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Automatic sample Dewar for MX beam-line

It is very common for crystals of large biological macromolecules to show considerable variation in quality of their diffraction. In order to increase the number of samples that are tested for diffraction quality before any full data collections at the ESRF*, an automatic sample Dewar has been implemented. Conception and performances of the Dewar are reported in this paper. The automatic sample Dewar has 240 samples capability with automatic loading/unloading ports. The storing Dewar is capable to work with robots and it can be integrated in a full automatic MX** beam-line. The samples are positioned in the front of the loading/unloading ports with and automatic rotating plate. A view port has been implemented for data matrix camera reading on each sample loaded in the Dewar. At last, the Dewar is insulated with polyurethane foam that keeps the liquid nitrogen consumption below 1.6 L/h. At last, the static insulation also makes vacuum equipment and maintenance unnecessary. This Dewar will be useful for increasing the number of samples tested in synchrotrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Attosecond transient absorption instrumentation for thin film materials: Phase transitions, heat dissipation, signal stabilization, timing correction, and rapid sample rotation

We present an extreme ultraviolet (XUV) transient absorption apparatus tailored to attosecond and femtosecond measurements on bulk solid-state thin-film samples, specifically when the sample dynamics are sensitive to heating effects. The setup combines methodology for stabilizing sub-femtosecond time-resolution measurements over 48 h and techniques for mitigating heat buildup in temperature-dependent samples. Single-point beam stabilization in pump and probe arms and periodic time-zero reference measurements are described for accurate timing and stabilization. A hollow-shaft motor configuration for rapid sample rotation, raster scanning capability, and additional diagnostics are described for heat mitigation. Heat transfer simulations performed using a finite element analysis allow comparison of sample rotation and traditional raster scanning techniques for 100 Hz pulsed laser measurements on vanadium dioxide, a material that undergoes an insulator-to-metal transition at a modest temperature of 340 K. Experimental results are presented confirming that the vanadium dioxide (VO 2 ) sample cannot cool below its phase transition temperature between laser pulses without rapid rotation, in agreement with the simulations. The findings indicate the stringent conditions required to perform rigorous broadband XUV time-resolved absorption measurements on bulk solid-state samples, particularly those with temperature sensitivity, and elucidate a clear methodology to perform them.

47 OTHER INSTRUMENTATION↗

The combined force field-sampling problem in simulations of disordered amyloid-β peptides

Molecular dynamics simulations of intrinsically disordered proteins (IDPs) can provide high resolution structural ensembles if the force field is accurate enough and if the simulation sufficiently samples the conformational space of the IDP with the correct weighting of sub-populations. Here, we investigate the combined force field–sampling problem by testing a standard force field as well as newer fixed charge force fields, the latter specifically motivated for better description of unfolded states and IDPs, and comparing them with a standard temperature replica exchange (TREx) protocol and a non-equilibrium Temperature Cool Walking (TCW) sampling algorithm. The force field and sampling combinations are used to characterize the structural ensembles of the amyloid-beta peptides Aβ42 and Aβ43, which both should be random coils as shown recently by experimental nuclear magnetic resonance (NMR) and 2D Förster resonance energy transfer (FRET) experiments. The results illustrate the key importance of the sampling algorithm: while the standard force field using TREx is in poor agreement with the NMR J-coupling and nuclear Overhauser effect and 2D FRET data, when using the TCW method, the standard and optimized protein-water force field combinations are in very good agreement with the same experimental data since the TCW sampling method produces qualitatively different ensembles than TREx. Lastly, we also discuss the relative merit of the 2D FRET data when validating structural ensembles using the different force fields and sampling protocols investigated in this work for small IDPs such as the Aβ42 and Aβ43 peptides.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Heat capacity of microgram oxide samples by fast scanning calorimetry

Quantitative scanning calorimetry on microgram-sized samples opens a broad, new range of opportunities for studying the thermodynamic properties of quantity-limited materials, including those produced under extreme conditions or found as rare accessory minerals in nature. We calibrated the Mettler Toledo Flash DSC 2+ calorimeter to obtain quantitative heat capacities in the range 200–350 °C, using samples weighing between 2 and 11.5 μg. Our technique is applied to a new set of oxide materials to which it has never been used before, without the need for melting, glass transitions, or phase transformations. Heat capacity data were obtained for silica in the high pressure stishovite (rutile) structure, dense post-stishovite glass, standard fused quartz, and for TiO2 rutile. These heat capacities agree within 5%–15% with the literature values reported for rutile, stishovite, and fused SiO2 glass. The heat capacity of post-stishovite glass, made by heating stishovite to 1000 °C, is a newly reported value. After accurate calibrations, measured heat capacities were then used to calculate masses for samples in the microgram range, a substantial improvement over measurement in conventional microbalances, which have uncertainties approaching 50%–100% for such small samples. Since the typical uncertainty of heat capacities measured on 10–100 mg samples in conventional differential scanning calorimetry is typically 7% (1%–5% with careful work), flash differential scanning calorimetry, using samples a factor of 1000 smaller, increases the uncertainty of heat capacity measurements by a factor of <3, opening the door for meaningful measurements on ultra-small, high-pressure samples and other quantity-limited materials.

Instruments & Instrumentation↗