Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SURFACE CONTAMINATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

The TESS–Keck Survey. I. A Warm Sub-Saturn-mass Planet and a Caution about Stray Light in TESS Cameras

We report the detection of a Saturn-size exoplanet orbiting HD 332231 (TOI 1456) in light curves from the Transiting Exoplanet Survey Satellite (TESS). HD 332231—an F8 dwarf star with a V-band magnitude of 8.56—was observed by TESS in Sectors 14 and 15. We detect a single-transit event in the Sector 15 presearch data conditioning (PDC) light curve. We obtain spectroscopic follow-up observations of HD 332231 with the Automated Planet Finder, Keck I, and SONG telescopes. The orbital period we infer from radial velocity (RV) observations leads to the discovery of another transit in Sector 14 that was masked by PDC due to scattered light contamination. A joint analysis of the transit and RV data confirms the planetary nature of HD 332231 b, a Saturn-size (0.867{sub −0.025}{sup +0.027} R{sub J}), sub-Saturn-mass (0.244±0.021 M{sub J}) exoplanet on a 18.71 day circular orbit. The low surface gravity of HD 332231 b and the relatively low stellar flux it receives make it a compelling target for transmission spectroscopy. Also, the stellar obliquity is likely measurable via the Rossiter–McLaughlin effect, an exciting prospect given the 0.14 au orbital separation of HD 332231 b. The spectroscopic observations do not provide substantial evidence for any additional planets in the HD 332231 system, but continued RV monitoring is needed to further characterize this system. We also predict that the frequency and duration of masked data in the PDC light curves for TESS Sectors 14–16 could hide transits of some exoplanets with orbital periods between 10.5 and 17.5 days.

79 ASTRONOMY AND ASTROPHYSICS↗

Total metals, carbon, nitrogen & anion concentration data; Slate River & East River floodplains, Crested Butte, CO; May 2022-October 2022

This data package includes processed and undiluted measurements for metal, total carbon, total nitrogen, and anion concentrations from pore water (groundwater) and surface water samples from the Slate River and East River floodplains of Crested Butte, CO, focus field sites for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between May and October of 2022. These measurements were all recorded at the Arizona Laboratory for Emerging Contaminants (ALEC) at the University of Arizona located in Tucson, AZ. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 4C until measured at ALEC.Analysis by ICP-MS (metals):Measurements for total metals were made on the Agilent 7700x ICP-MS (for total metals) – Agilent Technologies, Santa Clara, CA. The analytical QA/QC protocol was adapted from US EPA Method 200.8 for analysis by ICP-MS. Calibration standards were prepared from multi-element stock solutions (SPEX Certiprep, Metuchen, NJ). Calibration curves include at least 7 points with correlation coefficients > 0.995. The QC protocol includes a continuing calibration blank (CCB), a continuing calibration verification (CCV) solution and at least one quality control sample (QCS) to be analyzed just after calibration and again after every 12 samples and at the completion of the run. The QCS solutions are from an independent source, such as NIST SRM 1643e - Trace elements in water, or QCS solutions from High Purity Standards (Charleston, SC). Acceptable QC responses must be between 90 and 110% of the certified value. Lastly, a suitable internal standard (usually Rh, In, Ga or Ge) is added using on-line addition into the sample line and mixing tee.Analysis by Shimadzu TOC-L (TOC/TN):The TOC-L system is a combustion technique where liquid samples are injected and combusted into CO2 for carbon detection by non-dispersive infrared (NDIR) and NO for detection by chemiluminescence. A calibration curve using five standard solutions between 0.1 and 7 ppm for carbon and 0.05 and 3.5 ppm for nitrogen is made for each type of measurement with a linearity >0.99. All samples, standards, and QC’s are prepared in 24mL scintillation vials that have been baked for 4hrs at 475 Cº and made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.Analysis by Ion Chromatography (Anions):The instrument used is the Thermo Scientific Dionex ICS-6000 using AS+AG22 column set for anion analysis with sodium carbonate eluent. A calibration curve using five standard solutions between 5 and 250 umol/L is made with a linearity >0.99. Standards and QC’s are prepared in 15mL polypropylene conical tubes, pipetted along with the samples into 1.5mL polypropylene vials. Dilutions are made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

Facile Decomposition of Organophosphonates by Dual Lewis Sites on a Fe 3 O 4 (111) Film

Dimethyl methylphosphonate (DMMP) is used as a simulant for toxic nerve agents and pesticides, rendering the understanding of surface chemistry requisite to design effective materials for organophosphonate (catalytic) decomposition at room temperature. In this work, DMMP surface chemistry is studied on an iron oxide surface in a very well-defined environment using temperature-programmed reaction, isotopic labeling, scanning tunneling microscopy, X-ray photoelectron spectroscopy, and density functional theory. DMMP, (CH 3 O) 2 P(O)(CH 3 ), dissociates to yield methoxy and methyl methylphosphonate, (CH 3 O)P(O) 2 (CH 3 ), on the surface at room temperature. At higher temperatures, dimethyl ether is formed via intramolecular reaction, followed by the formation of formaldehyde and methanol from adsorbed methoxy decomposition during temperature-programmed reaction. Ultimately, stochiometric combustion at 870 K produces CO, H 2 C=O, and CO 2 via reaction with lattice oxygen, with PO x remaining on the surface. Excess oxygen from the bulk is required to drive these higher temperature pathways. Neither hydrolysis nor a photoreaction is observed, when exposing the adsorbed DMMP to water or light above the band gap, respectively. No evolution of P-containing species is detected, indicating efficient trapping of this contaminant. The activity for DMMP decomposition at room temperature is reduced by the accumulation of PO x . However, a significant amount of reaction persists after multiple temperature-programmed reaction experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of nitrogen on lithium-induced corrosion and cracking of RAFM steel

The emergence of private fusion enterprises, combined with advancements in U.S. and EU ITER-TBM as well as EU DEMO liquid breeder blanket concepts, has renewed focus on the materials challenges. This study examines the compatibility of reduced activation ferritic/martensitic (RAFM) steel in liquid Lithium (Li) containing various Nitrogen (N) concentrations, tested at 600 and 700 °C for 500 and 1000 h under static conditions. Microstructural characterization revealed the corrosion-induced dissolution and precipitation in Li containing 0.082 and 0.17 wt.% N at 600 °C, while limited dissolution and precipitation were observed in N-gettered Li using zirconium (Zr) and titanium (Ti) foils at 600 °C. Tensile testing at room temperature after Li exposure revealed a decrease in strength and ductility of the RAFM steel as a function of N content in Li. Severe embrittlement was observed after 500 h in Li containing 0.17 wt.% N at 600 °C and after 500 h in hot-gettered Li at 700 °C. Chromium (Cr) depletion from the steel matrix was observed, leading to the formation of M6C-type carbides on the surface identified by electron microscopy (SEM), X-ray diffraction (XRD), in agreement with thermodynamic calculations. These findings highlight the critical materials challenges posed by liquid Li breeder blanket concepts, emphasizing the need for improved strategies to address Li-induced dissolution, precipitation, and steel embrittlement due to N contamination of the coolant.

Romedenne, Marie [ORNL] (ORCID:0000000317936561)↗

A tale of a tail: a tidally disrupting ultra-diffuse galaxy in the M81 group

ABSTRACT We present the discovery of a giant tidal tail of stars associated with F8D1, the closest known example of an ultra-diffuse galaxy (UDG). F8D1 sits in a region of the sky heavily contaminated by Galactic cirrus and has been poorly studied since its discovery two decades ago. The tidal feature was revealed in a deep map of resolved red giant branch stars constructed using data from our Subaru Hyper Suprime-Cam survey of the M81 Group. It has an average surface brightness of μg ∼ 32 mag arcsec−2 and can be traced for over a degree on the sky (60 kpc at the distance of F8D1) with our current imagery. We revisit the main body properties of F8D1 using deep multiband imagery acquired with MegaCam on CFHT and measure effective radii of 1.7–1.9 kpc, central surface brightnesses of 24.7–25.7 mag, and a stellar mass of ∼7 × 107M⊙. Assuming a symmetric feature on the other side of the galaxy, we calculate that 30–36 per cent of F8D1’s present-day luminosity is contained in the tail. We argue that the most likely origin of F8D1’s disruption is a recent close passage to M81, which would have stripped its gas and quenched its star formation. As the only UDG that has so far been studied to such faint surface brightness depths, the unveiling of F8D1’s tidal disruption is important. It leaves open the possibility that many other UDGs could be the result of similar processes, with the most telling signatures of this lurking below current detection limits.

Žemaitis, Rokas (ORCID:0000000285660491)↗

Comparing the response of the indigenous microbial community to crude oil amendment in oxic versus hypoxic conditions

The Caspian Sea is the world’s largest landlocked saline lake which lies between Europe and Asia. This region is particularly known for its large-scale oil reserves, pipelines, and drilling activities, which have contributed to the environmental decline of this lake. In addition to pollution from the petroleum industry, drainage from various river basins brings an influx of residential, industrial, and agricultural effluents that induce eutrophication and hypoxic conditions in deeper, colder waters, creating an oxygen gradient. The temperature and oxygen stratification in this environment has presented a unique opportunity to investigate the potential of the biodegradative processes carried out by the indigenous microbial community. We believe these indigenous microbes possess different metabolic capabilities to degrade oil as they adapted to declining oxygen concentrations and temperatures with increasing depths over a prolonged period. Hence, community structure and composition will vary with depth. Microcosms were set up to observe the indigenous microbial reaction after a 60 ppm native crude oil amendment over 115 days. Surface water microcosms were incubated at 28ºC and aerated while deep water microcosms were incubated at 8ºC under anaerobic conditions. These two environmental conditions represent the temperature and oxygen extremes along the gradient and were selected as we try to simulate the indigenous community’s response to this oil contamination. DNA was extracted and amplified from these microcosms and sequenced. Bioinformatic analysis was performed to track changes in the abundance of taxa present and biodiversity over different time points to show the progression of community structure. All microcosms showed the presence of hydrocarbon-degrading phyla, whose presence is consistent with other reports from oil-enriched environments. However, distinct communities were observed in oxic versus hypoxic microcosms. Orders of Bacteria related to sulfate and nitrogen cycling were found in hypoxic microcosms, indicating a possible mechanism for the anaerobic biodegradation of crude oil. GC-MS analysis of initial and final microcosms also provided evidence of degradation of hydrocarbon fractions in both warm, oxic and cold, hypoxic conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Field-Scale Lysimeter Studies of Glass and Cementitious Waste Forms at the Hanford Site - 20392

The Hanford site Integrated Disposal Facility (IDF) will receive waste forms from vitrification activities at the Hanford Waste Treatment and Immobilization Plant (WTP). The waste form inventory to be disposed of at the IDF will consist of vitrified low-activity waste (LAW) in glass forms and solidified (or encapsulated) secondary wastes in cementitious forms. The IDF is a near-surface burial facility located near Hanford's Waste Treatment and Immobilization Plant in the 200 East Area of the site's Central Plateau. An extensive set of laboratory experimental data has been collected to support IDF performance assessment calculations of the eventual degradation of waste forms and mobility of contaminants. This paper describes the start of a field experiment to generate waste-form performance data on a larger scale (tens of centimeters), over a longer duration (five years or more), and under field conditions representative of the IDF. Results from this study are expected to improve model descriptions of contaminant mobility, reduce uncertainties about the representativeness of laboratory results in the IDF performance assessment, improve stakeholder confidence in the safe disposal of treated waste at the IDF, and facilitate the adoption of informed facility designs with the potential to reduce operational costs. A lysimeter test facility near Hanford's 200 West Area has been repurposed to carry out long-term assessments of waste forms buried in sediments excavated from the IDF. The waste forms are buried in large drainage lysimeters, open caissons that are two meters in diameter and three meters deep. Waste forms are buried in up to six locations in each lysimeter. Samplers collect pore water and drainage water beneath the waste forms and air from the pore space adjacent to waste forms. Sensors measure temperature, soil water content, soil water tension, and drainage flux. One lysimeter containing cementitious waste forms and one containing glass waste forms have been completed, along with a control lysimeter (without waste forms). The cementitious waste forms are Cast Stone grout formulations using a liquid secondary waste simulant and a generic Hanford high-salt simulant, as well as a hydrated lime-based grout formulation using a liquid secondary waste simulant. Technetium-99 and iodine-127 were added as tracers to monitor contaminant mobility. Glass waste forms were fabricated in two formulations (LAWA44 and ORLEC28), with rhenium and molybdenum tracers to monitor waste form degradation. The predicted performance of the waste forms in the lysimeters was modeled prior to installation to determine waste form size, tracer concentration/activity, and locations of sensors and samplers. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Description and Genome Characterization of Three Novel Fungal Strains Isolated from Mars 2020 Mission-Associated Spacecraft Assembly Facility Surfaces—Recommendations for Two New Genera and One Species

National Aeronautics and Space Administration’s (NASA) spacecraft assembly facilities are monitored for the presence of any bacteria or fungi that might conceivably survive a transfer to an extraterrestrial environment. Fungi present a broad and diverse range of phenotypic and functional traits to adapt to extreme conditions, hence the detection of fungi and subsequent eradication of them are needed to prevent forward contamination for future NASA missions. During the construction and assembly for the Mars 2020 mission, three fungal strains with unique morphological and phylogenetic properties were isolated from spacecraft assembly facilities. The reconstruction of phylogenetic trees based on several gene loci (ITS, LSU, SSU, RPB, TUB, TEF1) using multi-locus sequence typing (MLST) and whole genome sequencing (WGS) analyses supported the hypothesis that these were novel species. Here we report the genus or species-level classification of these three novel strains via a polyphasic approach using phylogenetic analysis, colony and cell morphology, and comparative analysis of WGS. The strain FJI-L9-BK-P1 isolated from the Jet Propulsion Laboratory Spacecraft Assembly Facility (JPL-SAF) exhibited a putative phylogenetic relationship with the strain Aaosphaeria arxii CBS175.79 but showed distinct morphology and microscopic features. Another JPL-SAF strain, FJII-L3-CM-DR1, was phylogenetically distinct from members of the family Trichomeriaceae and exhibited morphologically different features from the genera Lithohypha and Strelitziana. The strain FKI-L1-BK-DR1 isolated from the Kennedy Space Center facility was identified as a member of Dothideomycetes incertae sedis and is closely related to the family Kirschsteiniotheliaceae according to a phylogenetic analysis. The polyphasic taxonomic approach supported the recommendation for establishing two novel genera and one novel species. The names Aaosphaeria pasadenensis (FJI-L9-BK-P1 = NRRL 64424 = DSM 114621), Pasadenomyces melaninifex (FJII-L3-CM-DR1 = NRRL 64433 = DSM 114623), and Floridaphiala radiotolerans (FKI-L1-BK-DR1 = NRRL 64434 = DSM 114624) are proposed as type species. Furthermore, resistance to ultraviolet-C and presence of specific biosynthetic gene cluster(s) coding for metabolically active compounds are unique to these strains.

59 BASIC BIOLOGICAL SCIENCES↗

On the provenance of GEMS, a quarter century post discovery

The provenance of GEMS (glass with embedded metal and sulfides) in cometary type interplanetary dust particles is investigated using analytical scanning transmission electron microscopy and secondary ion mass spectrometry. We review the current state of knowledge and closely examine the densities, elemental compositions and distributions, iron oxidation states, and isotopic compositions of a subset of GEMS in chondritic porous interplanetary dust. We find that GEMS are underdense with estimated densities that are 35–65% of compositionally equivalent crystalline aggregates. GEMS low densities result in a lower contribution to the bulk compositions of IDPs than has been assumed based on their volume fraction. We also find that element/Si ratios, assumed to be primary (indigenous), are instead perturbed by contamination and secondary alteration, including pulse heating during atmospheric entry. Fe in pyrrhotite inclusions was oxidized and Mg, S, Ca, and Fe were depleted relative to lithophile Al and Si, resulting in reduction in element/Si ratios. Because they trap outgassing elements, Fe-rich oxide rims that formed on the surface of GEMS are serendipitous “witness plates” to the changes in composition that accompany atmospheric entry. As a result of alteration, GEMS elemental compositions cannot reliably inform about their provenance. Except for highly anomalous oxygen isotope ratios measured in some large GEMS grains that indicate a contribution from circumstellar dust, oxygen isotope compositions are generally poor indicators of provenance. Prior work indicates that most GEMS fall close to the terrestrial oxygen isotope composition, which, however, does not exclude a presolar interstellar origin. Nitrogen isotopic compositions are more diagnostic. Elevated 15 N/ 14 N ratios indicate that GEMS accreted in conjunction with formation of organic matter by ion–molecule reactions in a cold (<50 K) presolar environment like the extreme outer nebula or interstellar medium. Considering all observations, we conclude that GEMS are most likely processed interstellar silicates.

79 ASTRONOMY AND ASTROPHYSICS↗

Hanford Site Composite Analysis: Recharge and Inventory Sensitivity Analyses for the A Trenches, BC Cribs and Trenches, and PUREX Area Vadose Zone Models

The main objectives of the composite analysis (CA) compliance case vadose zone (VZ) facet are to simulate transport of radionuclide releases from the surface to the water table, and to provide radionuclide transfer rates to groundwater for inclusion into the Plateau-to-River (P2R) saturated zone (SZ) model (CP-57037, Model Package Report: Plateau to River Groundwater Model, Version 8.3). The CA compliance case approach to address the scale and distribution of contaminant sources in the VZ facet is to subdivide the Hanford Site Central Plateau into 26 models that contain contaminant sources and liquid discharges likely to commingle during migration through the VZ to the water table

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development and Field Testing Novel Natural Gas Surface Process Equipment for Replacement of Water as Primary Hydraulic Fracturing Fluid (Final Report)

Southwest Research Institute® (SwRI ® ), Schlumberger Technology Corporation (SLB), and Chevron Corporation ® (Chevron) developed a novel, optimized, and lightweight process for natural gas (NG) to replace water as a low-cost fracturing medium with a low environmental impact. Hydraulic fracturing is used to increase oil and NG production by injecting high-pressure fluid, primarily water, into a rock formation, which fractures the rock and releases trapped oil and NG. This method was developed to increase yield and make feasible production areas that would not otherwise be viable for large-scale oil and NG extraction using traditional drilling technologies. Since the fracturing fluid is composed of approximately 90% water, one of the principal drawbacks to hydraulic fracturing is its excessive water use and associated large environmental footprint. According to recent data collected at fracture sites within the United States, fracturing applications in North America can consume as much as 9 million gallons of water per well. During the fracturing process, some of the fracturing fluid is permanently lost and the portion that is recovered is contaminated by both fracturing chemicals and dissolved solids from the formation. The recovered water or flow-back represents a significant environmental challenge, as it must be treated before it can be reintroduced into the natural water system. Although there is some recycling for future fracturing, the majority of the flow-back water is hauled from the well site to a treatment facility or to an injection well for permanent underground disposal. To mitigate these issues, an optimized, lightweight and modular surface process using NG to replace a majority of the water was developed as a cost-effective and environmentally clean fracturing fluid. Using NG will result in significantly less consumption since the gas that is injected as a fracturing fluid will be mixed with the formation gas and extracted as if it were from the formation itself. This process will minimize the collection, waste, and treatment of large amounts of water and will reduce the environmental impact of transporting and storing the fracturing fluid. There are two major steps involved in utilizing NG as the primary fracturing medium: (1) increasing the supply pressure of NG to wellhead pressures suitable for fracturing and (2) mixing the required chemicals and proppant needed for the fracturing process at these elevated pressures. The second step (NG-proppant mixing at elevated pressures) still requires demonstration; but very similar processes have been demonstrated in the field with other gases such as nitrogen (N 2 ) and carbon dioxide (CO 2 ). However, the first step (a compact, on-site unit for generating high-pressure NG at costs feasible for fracturing) has not been developed and is currently not commercially available. Due to the inherent compressibility of NG, more energy is required to compress the gas than what is required to pump water (or other incompressible liquids) to the very high pressure required for downhole injection. This project aimed to develop a novel, hybrid method to overcome this challenge. The project accomplishments and findings are discussed in this report. Ultimately, the research and development efforts described herein demonstrate that fracturing with NG foam is a feasible alternative to using water.

02 PETROLEUM↗

Hanford Site Composite Analysis: LLBG-200-W B Vadose Zone Model

The objectives of the vadose modeling for the updated Hanford Site Composite Analysis (CA) are to simulate the flow and transport of water and radionuclide releases from the surface to the water table and to provide radionuclide transfer rates to the CA saturated zone model (CP-57037, Model Package Report: Plateau to River Groundwater Model, Version 8.3). Water additions include natural recharge and water discharged to the ground as a result of industrial processes associated with Hanford Site operations. Contaminant sources include radionuclides in water discharged to the ground during operations and radionuclides disposed “dry” in solid waste burial grounds or other means. The following 16 radionuclides were selected for this modeling effort: carbon-14 (C-14), chlorine-36 (Cl-36), tritium (H-3), iodine-129 (I-129), neptunium-237 (Np-237), rhenium-187 (Re-187), strontium-90 (Sr-90), technetium-99 (Tc-99), uranium-232 (U-232), uranium-233 (U-233), uranium-234 (U-234), uranium-235 (U-235), uranium-236 (U-236), uranium-238 (U-238), radium-226 (Ra-226), and thorium-230 (Th-230). The simulation time starts in 1943 and ends at 12070, which is 10,000 years after assumed Hanford Site closure in 2070. The parallel version of the Subsurface Transport Over Multiple Phases (STOMP 1 ) simulator, officially named the exascale Subsurface Transport Over Multiple Phases (eSTOMP), is used to simulate flow and transport for the vadose models. The documentation for the STOMP code is comprehensive. The theoretical and numerical approaches applied in the STOMP code are documented in a published theory guide (PNNL-12030, STOMP Subsurface Transport Over Multiple Phases Version 2.0 Theory Guide). The code has undergone a rigorous verification procedure against analytical solutions, laboratory-scale experiments, and field-scale demonstrations. The application guide (PNNL-11216, STOMP Subsurface Transport Over Multiple Phases Application Guide) provides instructive examples in the application of the code to classical groundwater problems. The user’s guide (PNNL-15782, STOMP: Subsurface Transport Over Multiple Phases Version 4.0: User’s Guide) describes the general use, input file formatting, compilation, and execution of the code. The primary output of the vadose zone modeling is radionuclide transfer rates to the groundwater for input into the saturated zone model. The rates will be summed over the 100 by 100 m saturated zone model grid cells that fall within the vadose zone model source domain.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Exploring Approaches for Accelerated Mass Spectrometric Detection of Fluorochemicals from Aqueous Solutions Using Indirect, Adsorbent-Facilitated Desorption Ionization

There is a growing need for rapid, low-cost analytical tools to screen water supplies for persistent contaminants. Due to their ubiquitous presence in the environment and their detrimental effects on human health, there is a public interest in widespread testing for perfluoroalkyl substances (PFAS). However, the most common methods for PFAS analysis can be time-intensive, requiring a preconcentration step followed by liquid chromatography–mass spectrometry (LC–MS), and are cost-prohibitive for most members of the public. To address these challenges, this study explores a novel method for rapid analysis of aqueous analytes by concentrating analytes on solid adsorbents and detecting them using mass spectrometric analysis via desorption ionization directly from the adsorbent surface. We demonstrate this general approach of indirect solution analysis (ISA) with desorption electrospray ionization (ISA-DESI) and laser desorption ionization (ISA-LDI). Various adsorbent materials were screened, including commercial mesoporous carbons, alumina, and metal–organic frameworks (MOFs). Using ISA-DESI, we consistently detect concentrations as low as 5–100 parts per trillion (ppt) for perfluorooctanoic acid (PFOA) and 10–100 ppt for perfluoroundecanoic acid (PFUnDA). This approach enables rapid detection in under 5 min, making it suitable for applications requiring trace detection with fast response times. We further demonstrate the use of ISA-DESI on a range of environmentally relevant contaminants. Advantages of this indirect solution analysis approach include simplified sample preparation, accelerated analysis, and low cost with readily available materials, making it a promising tool to accelerate mass spectrometric PFAS detection for identifying contaminated sites, performing laboratory studies, and monitoring industrial waste streams.

Bays, Nathan Robert [Sandia National Laboratories ↗

ZnO/CuO nanostructures anchored over Ni/Cu tubular films via pulse electrodeposition for photocatalytic and antibacterial applications

In this work, we report the fabrication of Ni and Cu tubular substrates and the synthesis of ZnO/CuO nanocomposite on them through the process of pulse electrodeposition. The systematic variation in CuO incorporation in the ZnO matrix and the processing technique were noticed to affect the structural, optical, photocatalytic, and anti-bacterial properties, which are well in accordance with the Field Emission-Scanning Electron Microscope, X-ray Diffraction, Fourier transform Infrared Spectroscopy and UV-Differential reflectance spectroscopy results. The remediation capabilities of the photocatalytic substrates were assessed through the degradation of methylene blue (MB) dye under solar irradiation. Optimized CuO incorporation within the ZnO nanorods resulted in the degradation of a 20 ppm of MB dye solution within 40 min and a higher concentration of 50 ppm within 95 min. The Ni and Cu electroformed tubes as substrates provided not only a reusable supporting frame but also a large surface-area for the growth of ZnO/CuO nanocomposite. The current study also dealt with the anti-bacterial efficacy of the above-mentioned substrates against E.coli. Hence, the Ni and Cu tubular thin film substrates with nanorods of ZnO/CuO composite were explored for the removal of organic as well as biological contaminants from waste water.

36 MATERIALS SCIENCE↗

Iodine Air Sampling: Installation and Preliminary Results

The F-Area wetlands are a known sink for radioiodine generated at the Savannah River Site (SRS). Wastewater containing iodine-129 ( 129 I) was discharged into the F-Area Seepage Basins for disposal, but the acidity of the wastewater mobilized some of the contaminants from the basin soil through the vadose zone and into the groundwater; ultimately creating a groundwater plume that extends towards Fourmile Branch and its associated wetland areas. Dissolved radioiodine specifically has migrated to the nearby F-Area wetlands, where it persists as a contaminant of concern. Accumulation and resurfacing of 129 I in the wetlands and nearby areas creates a potential secondary source zone where changes in biogeochemical conditions could result in the release of this sequestered 129 I to the air. Monitoring data has indicated that 129 I has a seasonal behavior at several surface water stations, with high concentrations during summertime and low concentrations during wintertime. Still, it is not known which factors control the seasonal behavior of 129 I. Further, it has been reported that 129 I contributed approximately 23% to the 2019 SRS offsite air pathway dose to the representative person for that year (SRNS, 2020), but air measurements of 129 I have never been taken in the F-Area wetlands. Because air emissions of 129 I from the wetlands have never been investigated, it is not known if this could be a potential release pathway that needs to be included in the site conceptual model. To address these unknowns, the Savannah River National Laboratory (SRNL) has an applied research task to investigate whether 129 I in the wetlands is emitted to the air and, if so, whether air concentrations exhibit seasonal variation. This report presents information about the system recently installed in the F-Area wetlands for measuring 129 I, as well as analysis results for samples collected June through August 2023. Quantification of this constituent will provide a better understanding of the contribution of airborne 129 I from the F-Area wetlands to the offsite dose and better inform ongoing and future remedial actions.

54 ENVIRONMENTAL SCIENCES↗

Large Area Airborne Contamination Monitoring

Current D&D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries. Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne plutonium, putting numerous workers at risk for radiological assimilations. Forty-two Hanford workers had positive bioassay results for plutonium uptake. Work areas determined to be free of airborne contamination as measured by state-of-the-art continuous alpha monitoring (CAM) systems were later discovered not to be. Airborne contamination was scattered to a such degree that CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required. A $\$ 19,000$ state of the art portable CAM system used at both Hanford and at SRS screens air for alpha activity at the rate of 1 CFM. This research project will explore the feasibility of using commercially available air purifying systems to screen significantly larger volumes of air for airborne actinide contamination. Commercial household HEPA based air purifying units screen large volumes of air, a simple $\$ 300$ unit being looked at for this study could screen a volume of air that would require over 300 of the $\$ 19,000$ CAMs. The goal of the project was to determine the feasibility of building a detection system capable of screening the air purifiers pre-filters and HEPA filters for any actinide bearing hot particles that have been captured. The simplest technologies available to Field-Radiological-Protection personnel are hand-held alpha field survey meters. With the size and the corrugated structure of these HEPA filters, hand screening is not practical. This project researched alternatives capable of automating this function. Two potential technologies were examined. One technology evaluated was the measurement of xray emissions from the actinides, taking advantage of the higher emission rates of the L x-rays compared to the gamma emissions of isotopes such as Pu-238 or Pu-239. High resolution to low resolution systems were evaluated. Branching ratio data on the actinides in the literature is incomplete, and a study was initiated to measure branching ratios of the various L emissions of a number of the plutonium isotopes. A Monte Carlo simulation was also run to calculate the effect the attenuating HEPA media would have on x-ray measurements on spectrometers centered in each quadrant above the surface of the HEPA. The second technology evaluated was measuring the light from a scintillating media applied to the surface of the HEPA filter using a ThorLabs Scientific-Grade Digital Camera Model 8051M. A light tight enclosure capable of holding the 2’x2’x1” HEPA filter was fabricated. Numerous scintillation media were evaluated for both the sensitivity and for resolution of measuring alpha activity. Figure 1 shows images of a 4”x4” section of HEPA filter with a 3 x 3 grid of Pu-238 contamination loaded inside the crevices of the HEPA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Review of "ML for Surface Complexation Model Development"

The presentation given by Jadallah Zouabe on “ML for Surface Complexation Model Development”was extremely informative, but lacked some explanation of details that made the latter half hard to follow as someone outside of the field. He began his presentation with an anecdote to spilling milk or ink on the floor and seeing it spread, cleverly connecting that to the spread of contamination in the real world. He then explained the importance of being able to model contamination, as it allows specialists to see the potential effects on different areas and environments in the coming years. Heal so made it clear that the main issue trying to be addressed here is how expensive modelling is and that their goal is to make computationally cheaper models. The introduction was overall very well formulated and attention-grabbing, but it seemed to take up too much of the presentation time, as after this point the presentation lacked details and explanations.

54 ENVIRONMENTAL SCIENCES↗

Characterization of Contaminants and Mobility in WMA A-AX Boreholes D0006 and D0008

This study was initiated to determine if subsurface contaminants in the A-AX vadose zone at the Hanford site (boreholes D0006 and D0008) caused corrosion of nearby stainless steel well casings (299-E-24-19, 299-E25-46, and 299-E25-236) and, based on the type and distribution of contaminants, determine if contaminants are from one or more sources including a) the A-104 and/or A-105 tanks, b) the 242A evaporator, and c) the 200-E-286 ditch. A tiered approach was used for characterizing contaminants in vadose zone sediments starting with mobile and total contaminant concentrations (Tier 1), characterizing contaminant speciation (Tier 2), and measuring contaminant leaching (Tier 3). Total and mobile contaminant measurements at seven depths showed elevated sulfate and nitrate in all samples (130 to 280 ft depth), elevated chloride in five depths, and no elevated radionuclides except I-129 in D0006 at 206 to 208 ft depth. If these contaminants were initially acidic, stainless-steel corrosion would occur. However, because sediments likely have a high acid neutralization capacity, an acidic spill would have been neutralized within tens of feet, so casing corrosion would likely occur in shallow sediments. GEL labs data also shows low (but above natural) chromate from shallow to 170 ft depth, then higher chromate to 280 ft, suggesting a surface Cr spill or casing corrosion. GEL labs data also showed evidence of more than one plume, with deep nitrate, sulfate, and chloride migration, but only shallow tritium migration. Tritium should migrate nearly unretarded in the subsurface like nitrate and chloride. Elevated aqueous cations and anions in the D0006 206 to 208' depth pore water (SO 4 2- , NO 3 - , Na + , K + , Ca 2+ , Mg 2+ , Si) could be the result of acid disposal and calcite dissolution at shallow depth, with deeper migration of SO 4 2- , NO 3 - from acids and Ca 2+ and Mg 2+ from calcite. Elevated Si (160 mg/L) indicates dissolution of clays or other silicates, which can also occur in acids. Acid extractable metals did show elevated Cr (but not Fe, Ni, Mo, and Mn) above natural levels, which may indicate stainless-steel well corrosion or transport of metals from a shallow spill. The elevated I-129 in D0006 at 206 to 208' depth was low with 0.34 μg/g in pore water and 1.5 μg/g total extractable I-129 in the sediment, which indicates significant fraction of I-129 was bound in one or more precipitates. Although total I-129 was below detection limits in most extractions due to high molybdate interference, I-127 analysis provided some insight into potential precipitate phases. Total I-127 was mainly extracted by acetate or acetic acid (67%), which may be iodine in calcite. Inorganic carbon measurement identified 1.65% calcite, and total organic carbon (TOC) was below detection limits, so iodine was not associated with organic matter. Nearly all the I-127 was present as iodide. In 1-D leach experiments, I-127 as iodide leached from the sediment within 2 pore volumes. Due to high and dynamic molybdate leaching from the sediment and interference with I-129 analysis, there were few quantifiable I-129 measurements. The calculated molybdate release rates from the sediment suggested Mo was being released from the same precipitate phase, such as molybdate incorporated into calcite. Overall, because there was little radioactive contamination measured in D0006 and D0008 boreholes, potential releases from A-104 and A-105 did not reach this location south of the A tank farm. Elevated cations and anions found in D0006 and D0008 at depth as the result of acidic disposal could cause shallow stainless steel casing corrosion. The nearby 242A evaporator generally contained alkaline waste and tritium, but the nearby 200-E-286 ditch generally contained high Cl - liquid effluent, so these are unlikely to be acidic sources.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗