Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

A CHALLENGING VIEW OF THE 2015 SUMMER V404 CYG OUTBURST AT HIGH ENERGY WITH INTEGRAL /SPI: THE FINALE

During its strong outburst of 2015 June/July, the X-ray transient V404 Cygni (=GS2023+338) was observed up to a level of 50 Crab in the hard X-ray domain. We focus here on a particularly intense episode preceeding a definitive decline of the source activity. We benefit from large signal-to-noise ratios to investigate the source spectral variability, on a timescale of five minutes. A hardness–intensity study of three broad bands reveals clearly different behaviors at low and high energy (below and above ∼100 keV). In particular, on two occasions, the source intensity varies by a factor of 3–4 in amplitude while keeping the same spectral shape. On the other hand, at the end of the major flare, the emission presents a clear anticorrelation between flux and hardness. These behaviors strongly suggest the presence of two spectral components related to emission processes varying in a largely independent way. The first component ( E < 100–150 keV) is classically identified with a Comptonizing thermal electron population, and requires either an unusual seed photon population or a specific geometry with strong absorbing/reflecting material. The second component is modeled by a cutoff power-law, which could correspond to a second hotter Comptonizing population or another mechanism (synchrotron, non-thermal Comptonization...). In the framework of such a model, hardness–intensity and flux–flux diagrams clearly demonstrate that the source evolution follows a well-organized underlying scheme. They reveal unique information about the hard X-ray emission processes and connections between them.

79 ASTRONOMY AND ASTROPHYSICS↗

Line Identification of Atomic and Ionic Spectra of Holmium in the Near-UV. II. Spectra of Ho ii and Ho iii

Fourier Transform spectra of holmium (Ho) in the UV spectral range from 31,530 to 25,000 cm{sup −1} (317 to 400 nm) have been investigated, particularly focusing on the ionic lines. The distinction between the different degrees of ionization (I, II, and III) is based on differences in signal-to-noise ratios from two Ho spectra, which have been measured with different buffer gases, i.e., neon and argon. Based on 106 known Ho ii and 126 known Ho iii energy levels, 97 lines could be classified as transitions of singly ionized Ho and 9 lines could be classified as transitions of doubly ionized Ho. Of the 97 Ho ii lines, 6 have not been listed in the extant literature. Another 215 lines have been assigned to Ho ii, though they could not be classified on the basis of the known energy levels.

74 ATOMIC AND MOLECULAR PHYSICS↗

Co-Registration of MEG and ULF MRI using a 7 channel low-Tc SQUID system

In human brain imaging, e.g. pre-surgical mapping, it is highly desired to obtain images with high spatial and temporal resolution. However, no single imaging device is capable of producing both a high spatial resolution anatomical image and a high temporal resolution functional image. During the last couple of years significant efforts have been directed towards magnetic resonance imaging (MRI) in fields comparable to the Earth's field, i.e. microtesla fields, or lower fields. The fields in this range are called ultra-low fields (ULF). Interestingly, the idea of magnetic resonance at microtesla fields is more than 50 years old. In ULF MR it is essential to use pre-polarization to increase the signal-to-noise ratio of the signal from the precessing spins, since the magnetization from the measurement field alone is very small. Even with the present level of prepolarization the ULF images are not as highly resolved as their high-field counterparts. By using a 7 channel system equipped with low transition temperature (T{sub c}) Superconducting QUantum Interference Devices (SQUIDs) to perform both ULF MRI and magnetoencephalography (MEG), it is possible to coregister a lower resolution ULF MR image and an MEG image obtained during one run. Thereby, the MEG data is aligned to the ULF MR image after performing a calibration run with a phantom. The ULF MR image can then be used to align the MEG data onto a high-field MR image. Recently, our group presented the first brain images obtained by ULF MRI. The MR imaging was combined with an MEG session performed a posteriori. The subject's head was moved in between the MRI run and the MEG run and no reference coils were used to quantify the translation. The main reason for the translation of the head was to improve the coverage of the auditory evoked response. In this paper, we report interleaved ULF MRI and MEG measurements co-registered in the same system.

42 ENGINEERING↗

A measurement of the cosmic microwave background gravitational lensing potential from 100 square degrees of SPTPOL data

We present a measurement of the cosmic microwave background (CMB) gravitational lensing potential using data from the first two seasons of observations with SPTpol, the polarization-sensitive receiver currently installed on the South Pole Telescope. The observations used in this work cover 100 deg{sup 2} of sky with arcminute resolution at 150 GHz. Using a quadratic estimator, we make maps of the CMB lensing potential from combinations of CMB temperature and polarization maps. We combine these lensing potential maps to form a minimum-variance (MV) map. The lensing potential is measured with a signal-to-noise ratio of greater than one for angular multipoles between 100<L<250. This is the highest signal-to-noise mass map made from the CMB to date and will be powerful in cross-correlation with other tracers of large-scale structure. We calculate the power spectrum of the lensing potential for each estimator, and we report the value of the MV power spectrum between 100<L<2000 as our primary result. We constrain the ratio of the spectrum to a fiducial ΛCDM model to be A{sub MV} = 0.92 ± 0.14 (Stat.) ± 0.08 (Sys.). Restricting ourselves to polarized data only, we find A{sub POL} = 0.92 ± 0.24 (Stat.) ± 0.11 (Sys.). This measurement rejects the hypothesis of no lensing at 5.9σ using polarization data alone, and at 14σ using both temperature and polarization data.

79 ASTRONOMY AND ASTROPHYSICS↗

The minimum crystal size needed for a complete diffraction data set

A formula for absolute scattering power is derived to include spot fading arising from radiation damage and the crystal volume needed to collect diffraction data to a given resolution is calculated. In this work, classic intensity formulae were united with an empirical spot-fading model in order to calculate the diameter of a spherical crystal that will scatter the required number of photons per spot at a desired resolution over the radiation-damage-limited lifetime. The influences of molecular weight, solvent content, Wilson B factor, X-ray wavelength and attenuation on scattering power and dose were all included. Taking the net photon count in a spot as the only source of noise, a complete data set with a signal-to-noise ratio of 2 at 2 Å resolution was predicted to be attainable from a perfect lysozyme crystal sphere 1.2 µm in diameter and two different models of photoelectron escape reduced this to 0.5 or 0.34 µm. These represent 15-fold to 700-fold less scattering power than the smallest experimentally determined crystal size to date, but the gap was shown to be consistent with the background scattering level of the relevant experiment. These results suggest that reduction of background photons and diffraction spot size on the detector are the principal paths to improving crystallographic data quality beyond current limits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Speech Intelligibility Advantages using an Acoustic Beamformer Display

A speech intelligibility test conforming to the Modified Rhyme Test of ANSI S3.2 "Method for Measuring the Intelligibility of Speech Over Communication Systems" was conducted using a prototype 12-channel acoustic beamformer system. The target speech material (signal) was identified against speech babble (noise), with calculated signal-noise ratios of 0, 5 and 10 dB. The signal was delivered at a fixed beam orientation of 135 deg (re 90 deg as the frontal direction of the array) and the noise at 135 deg (co-located) and 0 deg (separated). A significant improvement in intelligibility from 57% to 73% was found for spatial separation for the same signal-noise ratio (0 dB). Significant effects for improved intelligibility due to spatial separation were also found for higher signal-noise ratios (5 and 10 dB).

acoustic beamforming↗

Turbo code carrier synchronization losses (Radio Losses)

In this paper the radio loss results for (8920,1/3), (8920,1/6), (1783,1/3) and (1784,1/6) codes are presented. These radio losses were calculated through simulations for a range of data rates. These simulations included both suppressed carrier modulation and residual carrier modulation cases. The radio losses were calculated for a frame error rate of 3 x 10^-4 for (8920,1/3) and (8920,1/6) codes and 3 frame error rate of 6 x 10^-5 for (1764,1/3) and (1784,1/6) codes. The simulations for the residual carrier case were run for loop signal to noise ratios of 13dB, 15dB and 17dB with a loop bandwidth of 10Hz. The simulations for the suppressed carrier case were run for a loop of signal to noise ratio of 17dB. The results of these simulations indicate that the radio losses for turbo codes are low enough to warrant their use in deep space links (maximum of 1dB loss at 17dB loop signal to noise ratio for residual carrier and 1.3dB loss at 17dB loop signal to noise ratio for suppressed carrier at high data rates). Furthermore, these results indicate that by normalizing the radio losses for frame size, loop bandwidth and the loop signal to noise ratio, a single curve could be used for calculating the radio loss for any given data rate at any given loop signal to noise ratio.

suppressed carrier↗

Spacecraft ion beam noise effects

An estimate of the antenna noise temperature and the uplink signal-to-noise ratio has been made for Bremsstrahlung radiation emitted by a spacecraft ion beam; a worst-case situation in which the spacecraft antenna is located in the exit plane of the ion beam and directed at varying angles into the ion beam is assumed. Numerical results of the antenna noise temperature versus antenna pointing angle are given for a typical set of ion beam and antenna pattern parameters. The uplink signal-to-noise ratio due to the ion beam noise alone is given in terms of a critical range in AU at which a typical ranging transmission is received with S/N = 0 db. The effects of the ion beam divergence angle and antenna distance on the ion beam are also presented. Results of the study show typical increases in the antenna noise temperature of about 0.2 K and critical ranges of the order of 3-5 AU. An ion engine thus generally introduces an undetectable level of noise into a spacecraft receiver.

Anenberg, G. L.↗

A comparison of earthquake backprojection imaging methods for dense local arrays

Backprojection imaging has recently become a practical method for local earthquake detection and location due to the deployment of densely sampled, continuously recorded, local seismograph arrays. While backprojection sometimes utilizes the full seismic waveform, the waveforms are often pre-processed and simplified to overcome imaging challenges. Real data issues include aliased station spacing, inadequate array aperture, inaccurate velocity model, low signal-to-noise ratio, large noise bursts and varying waveform polarity. We compare the performance of backprojection with four previously used data pre-processing methods: raw waveform, envelope, short-term averaging/long-term averaging and kurtosis. Our primary goal is to detect and locate events smaller than noise by stacking prior to detection to improve the signal-to-noise ratio. The objective is to identify an optimized strategy for automated imaging that is robust in the presence of real-data issues, has the lowest signal-to-noise thresholds for detection and for location, has the best spatial resolution of the source images, preserves magnitude, and considers computational cost. Imaging method performance is assessed using a real aftershock data set recorded by the dense AIDA array following the 2011 Virginia earthquake. Our comparisons show that raw-waveform backprojection provides the best spatial resolution, preserves magnitude and boosts signal to detect events smaller than noise, but is most sensitive to velocity error, polarity error and noise bursts. On the other hand, the other methods avoid polarity error and reduce sensitivity to velocity error, but sacrifice spatial resolution and cannot effectively reduce noise by stacking. Of these, only kurtosis is insensitive to large noise bursts while being as efficient as the raw-waveform method to lower the detection threshold; however, it does not preserve the magnitude information. For automatic detection and location of events in a large data set, we therefore recommend backprojecting kurtosis waveforms, followed by a second pass on the detected events using noise-filtered raw waveforms to achieve the best of all criteria.

58 GEOSCIENCES↗

Coupled Receiver/Decoders for Low-Rate Turbo Codes

been proposed for receiving weak single- channel phase-modulated radio signals bearing low-rate-turbo-coded binary data. Originally intended for use in receiving telemetry signals from distant spacecraft, the proposed receiver/ decoders may also provide enhanced reception in mobile radiotelephone systems. A radio signal of the type to which the proposal applies comprises a residual carrier signal and a phase-modulated data signal. The residual carrier signal is needed as a phase reference for demodulation as a prerequisite to decoding. Low-rate turbo codes afford high coding gains and thereby enable the extraction of data from arriving radio signals that might otherwise be too weak. In the case of a conventional receiver, if the signal-to-noise ratio (specifically, the symbol energy to one-sided noise power spectral density) of the arriving signal is below approximately 0 dB, then there may not be enough energy per symbol to enable the receiver to recover properly the carrier phase. One could solve the problem at the transmitter by diverting some power from the data signal to the residual carrier. A better solution . a coupled receiver/decoder according to the proposal . could reduce the needed amount of residual carrier power. In all that follows, it is to be understood that all processing would be digital and the incoming signals to be processed would be, more precisely, outputs of analog-to-digital converters that preprocess the residual carrier and data signals at a rate of multiple samples per symbol. The upper part of the figure depicts a conventional receiving system, in which the receiver and decoder are uncoupled, and which is also called a non-data-aided system because output data from the decoder are not used in the receiver to aid in recovering the carrier phase. The receiver tracks the carrier phase from the residual carrier signal and uses the carrier phase to wipe phase noise off the data signal. The receiver typically includes a phase-locked loop (PLL) or Costas loop that requires no delay or perhaps a single sample delay. The lower part of the figure depicts a basic coupled receiver/decoder . a data-aided system that would implement an iterative receiving/decoding process. The receiver would include a PLL or a Wiener filter that, to the extent possible, would track the residual carrier signal, wipe phase noise off the data signal, then send the result to the turbo decoder. Recovery of timing could be effected by, for example, a digital transition tracking loop (DTTL) or other, similar loop. The first iteration of turbo decoding would yield soft data symbols, which would be sent back to the receiver for use in softly wiping off the data signal in an effort to recover the residual carrier signal. The wiped signal would contain a relatively large carrier-phase component that could be tracked by use of a second Wiener filter.

Hamkins, Jon↗

Scaling of muon remote sensing signals

Few hundred MeV muon beams can penetrate vessels, detect nuclear materials, and differentiate between them from distances of several hundred meters. A companion report provides point estimates of the beam and detector parameters required to do so. This note varies the most sensitive parameters to examine performance over a range of scenarios. In the process it examines the results of the IDA analysis of muon interrogation, finding no serious discrepancies in the cases and parameters it examined, although some parameters are admittedly somewhat arbitrary. This note concentrates on the sensitivity of performance to beam size and to signature path length in targets, i.e., the sizes of the targets and vessels. The main results are shown in the figures. The companion report provides a useful framework for analysis, although it concentrates on a few, perhaps atypical examples. This note uses that framework to explore the beam and standoff requirements for a wider range of engagements. It primarily studies the impact of beam radius and area at varying and constant and fixed dose, and varying vessel thickness. The first two figures show quite distinct variations of signal gammas, background levels, and signal to noise ratios, but their main result is that the signal to noise ratios greater than unity essential for practical application can be achieved at beam radii up to about 1 m. Imposition of required dose limits in Fig. 2 has little impact on that result. The third figure indicates that adequate signal to noise ratios are achievable for thicknesses up to 4-5 m. Those ranges could be improved by smaller beams and other improvements, but exploring them in detail should probably await the improvement of the elements of the model that are stressed for thicker vessels.

99 GENERAL AND MISCELLANEOUS↗

A Background Noise Reduction Technique Using Adaptive Noise Cancellation for Microphone Arrays

Background noise in wind tunnel environments poses a challenge to acoustic measurements due to possible low or negative Signal to Noise Ratios (SNRs) present in the testing environment. This paper overviews the application of time domain Adaptive Noise Cancellation (ANC) to microphone array signals with an intended application of background noise reduction in wind tunnels. An experiment was conducted to simulate background noise from a wind tunnel circuit measured by an out-of-flow microphone array in the tunnel test section. A reference microphone was used to acquire a background noise signal which interfered with the desired primary noise source signal at the array. The technique s efficacy was investigated using frequency spectra from the array microphones, array beamforming of the point source region, and subsequent deconvolution using the Deconvolution Approach for the Mapping of Acoustic Sources (DAMAS) algorithm. Comparisons were made with the conventional techniques for improving SNR of spectral and Cross-Spectral Matrix subtraction. The method was seen to recover the primary signal level in SNRs as low as -29 dB and outperform the conventional methods. A second processing approach using the center array microphone as the noise reference was investigated for more general applicability of the ANC technique. It outperformed the conventional methods at the -29 dB SNR but yielded less accurate results when coherence over the array dropped. This approach could possibly improve conventional testing methodology but must be investigated further under more realistic testing conditions.

Spalt, Taylor B.↗

Pre-emphasis determination for an S-band constant bandwidth FM/FM station

Pre-emphasis schedules are given for 11 constant-bandwidth FM subcarriers modulating an S band transmitter at three receiver signal to noise ratios (i.e., 9, 15, and 25 dB). The criterion for establishing these pre-emphasis curves is the achievement, at various receiver intermediate frequency signal to noise ratios, of equal receiver output signal to noise ratios for all channels. It is realized that these curves may not be the optimum pre-emphasis curves based on overall efficiency or maximum utilization of the allotted spectrum, but they are near-optimum for data with channels which require equal output signal to noise ratios, such as spectral densities. The empirically derived results are compared with a simplified, analytically derived schedule and the primary differences are explained. The S band pre-emphasis schedule differs from the lower frequency VHF case. Since most proportional bandwidth and constant bandwidth systems use ground based recorders and some use flight recorders (as the Saturn systems did on VHF proportional bandwidth telemetry), the effects of these recorders are discussed and a modified pre-emphasis schedule is presented showing the results of this study phase.

Wallace, G. R.↗

Bounding filter - A simple solution to lack of exact a priori statistics.

Wiener and Kalman-Bucy estimation problems assume that models describing the signal and noise stochastic processes are exactly known. When this modeling information, i.e., the signal and noise spectral densities for Wiener filter and the signal and noise dynamic system and disturbing noise representations for Kalman-Bucy filtering, is inexactly known, then the filter's performance is suboptimal and may even exhibit apparent divergence. In this paper a system is designed whereby the actual estimation error covariance is bounded by the covariance calculated by the estimator. Therefore, the estimator obtains a bound on the actual error covariance which is not available, and also prevents its apparent divergence.

Nahi, N. E.↗

SU-G-TeP2-11: Initial Evaluation of a Novel Split-Filter Dual-Energy CT for Use in Radiation Oncology

Purpose: To perform an initial evaluation of a novel split-filter dual-energy CT (DECT) system with the goal of understanding the clinical utility and limitations of the system for radiation therapy. Methods: Several phantoms were imaged using the split-filter DECT technique on the Siemens Edge CT scanner using a range of clinically-relevant doses. The optimum-contrast reconstruction, the mixed reconstruction, and the monoenergetic reconstructions (ranging from 40 keV to 190 keV) were evaluated. Each image was analyzed for CT number accuracy, uniformity, noise, low-contrast visibility (LCV), spatial resolution and geometric distortion. For comparison purposes, all parameters were evaluated on 120 kVp single-energy CT (SECT) scans used for treatment planning, as well as, a sequential-scan DECT technique for corresponding doses. Results: For all DECT reconstructions no observable geometric distortion was found. Both the optimal-contrast and mixed images demonstrated slight improvements in LCV and noise when compared to the SECT, and slight reductions in CT number accuracy and spatial resolution. The CT numbers trended as expected for the monoenergetic reconstructions, with CT number accuracy within 50 HU for materials of density <2 g/cm3. Spatial resolution increased with energy, and for monoenergetic reconstructions >70 keV the spatial resolution exceeded that of the SECT. The noise in the monoenergetic reconstructions increased with decreasing energy. Thus, the image uniformity, signal-to-noise ratio and LCV were diminished at lower energies (70 keV). Applying iterative reconstruction techniques to the low-energy images reduced noise and improved LCV. The signal-to-noise ratio was stable for energies >100 keV. Conclusion: The initial commissioning of the novel split-filter DECT technology demonstrated favorable results for clinical implementation. The mixed reconstruction showed potential as a replacement for the treatment planning SECT. The image parameters for the monoenergetic reconstructions varied appropriately with energy. This work provides an initial understanding of the limitations and potential applications for monoenergetic imaging.

60 APPLIED LIFE SCIENCES↗

Cryogenic Preamplification of a Single-Electron-Transistor using a Silicon-Germanium Heterojunction-Bipolar-Transistor

We examine a silicon-germanium heterojunction bipolar transistor (HBT) for cryogenic pre-amplification of a single electron transistor (SET). The SET current modulates the base current of the HBT directly. The HBT-SET circuit is immersed in liquid helium, and its frequency response from low frequency to several MHz is measured. The current gain and the noise spectrum with the HBT result in a signal-to-noise-ratio (SNR) that is a factor of 10–100 larger than without the HBT at lower frequencies. Furthermore, the transition frequency defined by SNR = 1 has been extended by as much as a factor of 10 compared to without the HBT amplification. The power dissipated by the HBT cryogenic pre-amplifier is approximately 5 nW to 5 μW for the investigated range of operation. We found that the circuit is also operated in a single electron charge read-out configuration in the time-domain as a proof-of-principle demonstration of the amplification approach for single spin read-out.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Noise effects in an optical heterodyne spectrometer using tunable diode lasers

A comparison of measured and predicted signal-to-noise ratio is made in an optical heterodyne spectrometer utilizing a tunable diode laser which exhibited excess noise. It is shown that good agreement between predicted and measured signal-to-noise ratios results if excess noise effects due to tunable diode lasers are included in the predictions. The methods used to quantify excess noise and to incorporate their effects into predictions of signal-to-noise ratio are discussed.

Katzberg, S. J.↗