Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

SU-E-J-83: Ion Imaging to Better Estimate In-Vivo Relative Stopping Powers Using X-Ray CT Prior-Knowledge Information

Purpose: To reduce uncertainties in relative stopping power (RSP) estimates for ions (alpha and carbon) by using Ion radiographic-imaging and X-ray CT prior-knowledge. Methods: A 36×36 phantom matrix composed of 9 materials with different thicknesses and randomly placed is generated. Theoretical RSPs are calculated using stopping power (SP) data from three references (Janni, ICRU49 and Bischel). We introduced an artificial systematic error (1.5%, 2.5% or 3.5%) and a random error (<0.5%) to the SP to simulated patient ion-range errors present in clinic environment. Carbon/alpha final energy for each RSPs set (theoretical and from CT images) is obtained with a ray-tracing algorithm. A gradient descent (GD) method is used to minimize the difference in exit particle energy, between theory and X-ray CT RSP maps, by iteratively correcting the RSP map from X-ray CT. Once a new set of RSPs is obtained for a direction a new optimization is done over other direction using the RSPs from the previous optimization. Theoretical RSPs are compared with experimental RSPs obtained with Gammex Phantom. Results: Preliminary results show that optimized RSP values can be obtained with smaller uncertainties (<1%) than clinical RSPs (1.5% to 3.5%). Theoretical values from three different references show uncertainties, up to 3% from experimental values. Further investigation will consider prior-knowledge from RSP obtained with CT images and ion radiographies from Monte Carlo Simulations. Conclusion: GD and ray-tracing methods have been implemented to reduce RSP uncertainties from values obtained for clinical treatment. Experimental RSPs will be obtained using carbon/alpha beams to consider the existence of material dependent systematic errors. Based on the results, it is hoped to show that using ray-tracing optimization with ion radiography and prior knowledge on RPSs, treatment planning accuracy and cost-effectiveness can be improved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear Magnetic Dipole and Electric Quadrupole Moments: Their Measurement and Tabulation as Accessible Data

The most recent tabulations of nuclear magnetic dipole and electric quadrupole moments have been prepared and published by the Nuclear Data Section of the IAEA, Vienna [N. J. Stone, Report No. INDC(NDS)-0650 (2013); Report No. INDC(NDS)-0658 (2014)]. The first of these is a table of recommended quadrupole moments for all isotopes in which all experimental results are made consistent with a limited number of adopted standards for each element; the second is a combined listing of all measurements of both moments. Both tables cover all isotopes and energy levels. In this paper, the considerations relevant to the preparation of both tables are described, together with observations as to the importance and (where appropriate) application of necessary corrections to achieve the “best” values. Some discussion of experimental methods is included with emphasis on their precision. The aim of the published quadrupole moment table is to provide a standard reference in which the value given for each moment is the best available and for which full provenance is given. A table of recommended magnetic dipole moments is in preparation, with the same objective in view.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The abundant elements in interstellar dust

We explore the incorporation of the cosmically abundant species O, C, N, Mg, Si, Fe, and S into interstellar dust. Column densities based on Goddard High Resolution Spectrograph 3.5 km/s resolution measurements from the literature for eight individual absorbing regions toward five lines of sight are used. Corrections are applied as needed in order to account for recent improvements in oscillator strengths. In order to acquire the most accurate column densities, and check on the accuracy of the oscillator strengths, we compare column densities based on the very strong Lorentzian damped lines of C II, O I, N I, and Mg II with results for the weak lines of these species, and confirm the previously determined f-values for O I lambda 1335, C II lambda 2325, and N I lambda lambda 1159, 1160. New empirical f-values of 1.25 x 10(exp -3) and 6.25 x 10(exp -4), respectively, are derived for the Mg II weak doublet at 1239 and 1240 A. Assuming a cosmic reference abundance based on solar and B star values, we derive depletions and dust-phase abundances which suggest that more than 70% of the available Mg and Fe is incorporated into dust-grain cores, whereas only 35% of the silicon is. This implies that oxides are important constituents of the grain core population. Mg and Fe atoms are mantled onto grain cores in a ratio of 1.8 to 1, whereas approximately 4.0 Si atoms are in the mantle per Fe atom. Since Si is not expected to accrete onto silicate or graphite grains, other grain cores, perhaps oxides and/or metallic Fe, may provide mantling sites for this species. The abundances of Fe and Mg in mantles would imply that graphite grains must have a substantial coating unless oxides provide significant mantling sites for these species. The abundance of O and N in the dust phase as implied by the solar reference abundance values are difficult to reconcile with the fact that these elements are not expected to participate in mantle formation, and the 3.1 micrometer H2O ice feature is not seen in absorption toward stars similar to those studied. The B star reference abundances for O and N, however, imply that no mantling of these species has occurred. The dust-phase abundance for C implied by solar reference abundances agrees with predictions for the number of graphite grains needed to produce the 2175 A bump. B star reference abundances, however, suggest that the abundance of C in the dust phase is not always sufficient to produce the bump.

Sofia, Ulysses J.↗

Two new diagnostics of dark energy

We introduce two new diagnostics of dark energy (DE). The first, Om, is a combination of the Hubble parameter and the cosmological redshift and provides a null test of dark energy being a cosmological constant {lambda}. Namely, if the value of Om(z) is the same at different redshifts, then DE{identical_to}{lambda}, exactly. The slope of Om(z) can differentiate between different models of dark energy even if the value of the matter density is not accurately known. For DE with an unevolving equation of state, a positive slope of Om(z) is suggestive of phantom (w<-1) while a negative slope indicates quintessence (w>-1). The second diagnostic--acceleration probe q--is the mean value of the deceleration parameter over a small redshift range. It can be used to determine the cosmological redshift at which the universe began to accelerate, again without reference to the current value of the matter density. We apply the Om and q diagnostics to the Union data set of type Ia supernovae combined with recent data from the cosmic microwave background (Wilkinson Microwave Anisotropy Probe 5) and baryon acoustic oscillations.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-354: Efficient and Enhanced QA Testing of Linear Accelerators Using a Real-Time Beam Monitor

Purpose: To investigate the feasibility of performing routine QA tests of linear accelerators (Linac) using the Integral Quality Monitoring (IQM) system. The system, consisting of a 1-D sensitivity gradient large area ion-chamber mounted at the collimator, allows automatic collection and analysis of beam data. Methods: The IQM was investigated to perform several QA constancy tests, similar to those recommended by AAPM TG142, of a Linac including: beam output, MLC calibration, beam symmetry, relative dose factor (RDF), dose linearity, output as a function of gantry angle and dose rate. All measurements by the IQM system accompanied a reference measurement using a conventional dosimetry system and were performed on an Elekta Infinity Linac with Agility MLC. The MLC calibration check is done using a Picket-Fence type 2×10cm{sup 2} field positioned at different off-axis locations along the chamber gradient. Beam symmetry constancy values are established by signals from an 4×4cm{sup 2} aperture located at various off-axis positions; the sensitivity of the test was determined by the changes in the signals in response to a tilt in the beam. The data for various square field sizes were used to develop a functional relationship with RDF. Results: The IQM tracked the beam output well within 1% of the reference ion-chamber readings. The Picket-Fence type field test detected a 1mm shift error of one MLC bank. The system was able to detect 2.5% or greater beam asymmetry. The IQM results for all other QA tests were found to agree with the reference values to within 0.5%. Conclusion: It was demonstrated that the IQM system can effectively monitor the Linac performance parameters for the purpose of routine QA constancy tests. With minimum user interactions a comprehensive set of tests can be performed efficiently, allowing frequent monitoring of the Linac. The presenting author’s salary is funded by the manufacturer of the QA device. All the other authors have financial interests with the commercialization of this QA device.

07 ISOTOPE AND RADIATION SOURCES↗

Statistical comparisons of aircraft flyover noise adjustment procedures for different weather conditions

Aircraft flyover noise spectra and effective perceived noise level (EPNL) values obtained under widely different weather conditions were adjusted according to a proposed national standard. The results were statistically compared with the same measured spectra adjusted according to an alternate procedure and with reference spectra and EPNL values obtained under almost ideal weather conditions. Three different ways to represent the weather condition through which the sound propagated were also evaluated.

Mueller, A. W.↗

Generalized Maximum Entropy

A long standing mystery in using Maximum Entropy (MaxEnt) is how to deal with constraints whose values are uncertain. This situation arises when constraint values are estimated from data, because of finite sample sizes. One approach to this problem, advocated by E.T. Jaynes [1], is to ignore this uncertainty, and treat the empirically observed values as exact. We refer to this as the classic MaxEnt approach. Classic MaxEnt gives point probabilities (subject to the given constraints), rather than probability densities. We develop an alternative approach that assumes that the uncertain constraint values are represented by a probability density {e.g: a Gaussian), and this uncertainty yields a MaxEnt posterior probability density. That is, the classic MaxEnt point probabilities are regarded as a multidimensional function of the given constraint values, and uncertainty on these values is transmitted through the MaxEnt function to give uncertainty over the MaXEnt probabilities. We illustrate this approach by explicitly calculating the generalized MaxEnt density for a simple but common case, then show how this can be extended numerically to the general case. This paper expands the generalized MaxEnt concept introduced in a previous paper [3].

Cheeseman, Peter↗

Direct measurement of the magnetic penetration depth by magnetic force microscopy

We present an experimental approach using magnetic force microscopy for measurements of the absolute value of the magnetic penetration depth λ in superconductors. λ is obtained in a simple and robust way without introducing any tip modeling procedure via direct comparison of the Meissner response curves for a material of interest to those measured for a reference sample. Using a well-characterized Nb film as a reference, we determine the absolute value of λ in a Ba(Fe 0.92 Co 0.08 ) 2 As 2 single crystal and a MgB 2 thin film through a comparative experiment. Our apparatus features simultaneous loading of multiple samples, and allows straightforward measurement of the absolute value of λ in superconducting thin film or single-crystal samples.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Understanding the chemical bonding of ground and excited states of HfO and HfB with correlated wavefunction theory and density functional approximations

Knowledge of the chemical bonding of HfO and HfB ground and low-lying electronic states provides essential insights into a range of catalysts and materials that contain Hf–O or Hf–B moieties. Here, we carry out high-level multi-reference configuration interaction theory and coupled cluster quantum chemical calculations on these systems. We compute full potential energy curves, excitation energies, ionization energies, electronic configurations, and spectroscopic parameters with large quadruple-ζ and quintuple-ζ quality correlation consistent basis sets. We also investigate equilibrium chemical bonding patterns and effects of correlating core electrons on property predictions. Differences in the ground state electron configuration of HfB(X 4 Σ - ) and HfO(X 1 Σ + ) lead to a significantly stronger bond in HfO than HfB, as judged by both dissociation energies and equilibrium bond distances. We extend our analysis to the chemical bonding patterns of the isovalent HfX (X = O, S, Se, Te, and Po) series and observe similar trends. We also note a linear trend between the decreasing value of the dissociation energy (D e ) from HfO to HfPo and the singlet–triplet energy gap (ΔE S–T ) of the molecule. Finally, we compare these benchmark results to those obtained using density functional theory (DFT) with 23 exchange–correlation functionals spanning multiple rungs of “Jacob’s ladder.” When comparing DFT errors to coupled cluster reference values on dissociation energies, excitation energies, and ionization energies of HfB and HfO, we observe semi-local generalized gradient approximations to significantly outperform more complex and high-cost functionals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Forensic investigation of plutonium metal: a case study of CRM 126

In our study, a certified plutonium metal reference material (CRM 126) with a known production history is examined using analytical methods that are commonly employed in nuclear forensics for provenancing and attribution. Moreover, the measured plutonium isotopic composition and actinide assay are consistent with values reported on the reference material certificate. Model ages from U/Pu and Am/Pu chronometers agree with the documented production timeline. Finally, these results confirm the utility of these analytical methods and highlight the importance of a holistic approach for forensic study of unknown materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ignition Delay Measurements of Four Component Model Gasolines Exploring the Impacts of Biofuels and Aromatics

This study explores the impacts of combinations of biofuel (ethanol, isobutanol and 2-methyl furan) and aromatic (toluene) compounds in a four component fuel blend, at fixed research octane number (RON) on ignition delay measured in an advanced fuel ignition delay analyzer (AFIDA 2805). Ignition delay measurements were performed over a range of temperatures from 400 to 725 °C (673 to 998 K) and two chamber pressures of 10 and 20 bar. The four component mixtures are compared to primary reference fuels at RON values of 90 and 100. The ignition delay measurements show that as the aromatic and biofuel concentrations increased, two stage ignition behavior was suppressed, at both initial chamber pressures. But both RON 100 (isooctane) and RON 90 reference fuels showed two stage ignition behavior, as did fuel mixtures with low biofuel and aromatic content. RON 90 fuels showed stronger two stage ignition behavior than RON 100 fuels, as expected. Depending on the type of biofuel in the mixture, the ignition delay at low chamber temperatures could be far greater than for the reference fuels. In particular, for the RON 100 mixtures at either 10 or 20 bar initial chamber pressure, the ignition delay at 400 °C (673 K) for the high level blend of 2-methyl furan and toluene (30 vol% of each) exhibited an ignition delay that was 10 times longer than for neat isooctane. The results show the strong non-linear octane blending response of these three biofuel compounds, especially in concert with the kinetic antagonism that toluene is known to display in mixtures with isooctane. These results have implications for the formulation of biofuel mixtures for spark ignition and advanced compression ignition engines, where this non-linear octane blending response could be exploited to improve knock resistance, or modulate the autoignition process.

2-methyl furan↗

Method and apparatus for displaying information

A method for displaying large amounts of information. The method includes the steps of forming a spatial layout of tiles each corresponding to a representative reference element; mapping observed elements onto the spatial layout of tiles of representative reference elements; assigning a respective value to each respective tile of the spatial layout of the representative elements; and displaying an image of the spatial layout of tiles of representative elements. Each tile includes atomic attributes of representative elements. The invention also relates to an apparatus for displaying large amounts of information. The apparatus includes a tiler forming a spatial layout of tiles, each corresponding to a representative reference element; a comparator mapping observed elements onto said spatial layout of tiles of representative reference elements; an assigner assigning a respective value to each respective tile of said spatial layout of representative reference elements; and a display displaying an image of the spatial layout of tiles of representative reference elements.

Ingber, Donald E.↗

Baseline blood levels of manganese, lead, cadmium, copper, and zinc in residents of Beijing suburb

Baseline blood concentrations of metals are important references for monitoring metal exposure in environmental and occupational settings. The purpose of this study was to determine the blood levels of manganese (Mn), copper (Cu), zinc (Zn), lead (Pb), and cadmium (Cd) among the residents (aged 12–60 years old) living in the suburb southwest of Beijing in China and to compare the outcomes with reported values in various developed countries. Blood samples were collected from 648 subjects from March 2009 to February 2010. Metal concentrations in the whole blood were determined by ICP-MS. The geometric means of blood levels of Mn, Cu, Zn, Pb and Cd were 11.4, 802.4, 4665, 42.6, and 0.68 µg/L, respectively. Male subjects had higher blood Pb than the females, while the females had higher blood Mn and Cu than the males. There was no gender difference for blood Cd and Zn. Smokers had higher blood Cu, Zn, and Cd than nonsmokers. There were significant age-related differences in blood levels of all metals studied; subjects in the 17–30 age group had higher blood levels of Mn, Pb, Cu, and Zn, while those in the 46–60 age group had higher Cd than the other age groups. A remarkably lower blood level of Cu and Zn in this population as compared with residents of other developed countries was noticed. Based on the current study, the normal reference ranges for the blood Mn were estimated to be 5.80–25.2 μg/L; for blood Cu, 541–1475 μg/L; for blood Zn, 2349–9492 μg/L; for blood Pb, <100 μg/L; and for blood Cd, <5.30 μg/L in the general population living in Beijing suburbs. - Highlights: • Baseline blood levels of metals in residents of Beijing suburb are investigated. • BMn and BPb in this cohort are higher than those in other developed countries. • Remarkably lower blood levels of Cu and Zn in this Chinese cohort are noticed. • The reference values for blood levels of Mn, Cu, Zn, Pb, and Cd are established.

54 ENVIRONMENTAL SCIENCES↗

Updated evaluation of potential ultralow Q -value β -decay candidates

“Ultralow” Q-value β decays are referred to as such due to their low decay energies of less than ≈1 keV. Such a low energy decay is possible when the parent nucleus decays to an excited state in the daughter, with an energy close to that of the Q value. These decays are of interest as potential new candidates for neutrino mass determination experiments and as a testing ground for studies of atomic interference effects in the nuclear decay process. In this paper, we provide an updated evaluation of atomic mass data and nuclear energy-level data to identify potential ultralow Q-value β decay candidates. For many of these candidates, more precise and accurate atomic mass data is needed to determine if the Q value of the potential ultralow decay branch is energetically allowed and in fact ultralow. Furthermore, the relevant precise atomic mass measurements can be achieved via Penning trap mass spectrometry.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Automating linear accelerator quality assurance

Purpose: The purpose of this study was 2-fold. One purpose was to develop an automated, streamlined quality assurance (QA) program for use by multiple centers. The second purpose was to evaluate machine performance over time for multiple centers using linear accelerator (Linac) log files and electronic portal images. The authors sought to evaluate variations in Linac performance to establish as a reference for other centers. Methods: The authors developed analytical software tools for a QA program using both log files and electronic portal imaging device (EPID) measurements. The first tool is a general analysis tool which can read and visually represent data in the log file. This tool, which can be used to automatically analyze patient treatment or QA log files, examines the files for Linac deviations which exceed thresholds. The second set of tools consists of a test suite of QA fields, a standard phantom, and software to collect information from the log files on deviations from the expected values. The test suite was designed to focus on the mechanical tests of the Linac to include jaw, MLC, and collimator positions during static, IMRT, and volumetric modulated arc therapy delivery. A consortium of eight institutions delivered the test suite at monthly or weekly intervals on each Linac using a standard phantom. The behavior of various components was analyzed for eight TrueBeam Linacs. Results: For the EPID and trajectory log file analysis, all observed deviations which exceeded established thresholds for Linac behavior resulted in a beam hold off. In the absence of an interlock-triggering event, the maximum observed log file deviations between the expected and actual component positions (such as MLC leaves) varied from less than 1% to 26% of published tolerance thresholds. The maximum and standard deviations of the variations due to gantry sag, collimator angle, jaw position, and MLC positions are presented. Gantry sag among Linacs was 0.336 ± 0.072 mm. The standard deviation in MLC position, as determined by EPID measurements, across the consortium was 0.33 mm for IMRT fields. With respect to the log files, the deviations between expected and actual positions for parameters were small (<0.12 mm) for all Linacs. Considering both log files and EPID measurements, all parameters were well within published tolerance values. Variations in collimator angle, MLC position, and gantry sag were also evaluated for all Linacs. Conclusions: The performance of the TrueBeam Linac model was shown to be consistent based on automated analysis of trajectory log files and EPID images acquired during delivery of a standardized test suite. The results can be compared directly to tolerance thresholds. In addition, sharing of results from standard tests across institutions can facilitate the identification of QA process and Linac changes. These reference values are presented along with the standard deviation for common tests so that the test suite can be used by other centers to evaluate their Linac performance against those in this consortium.

60 APPLIED LIFE SCIENCES↗

Cold-air investigation of a 4 1/2 stage turbine with stage-loading factor of 4.66 and high specific work output. 2: Stage group performance

The stage group performance of a 4 1/2 stage turbine with an average stage loading factor of 4.66 and high specific work output was determined in cold air at design equivalent speed. The four stage turbine configuration produced design equivalent work output with an efficiency of 0.856; a barely discernible difference from the 0.855 obtained for the complete 4 1/2 stage turbine in a previous investigation. The turbine was designed and the procedure embodied the following design features: (1) controlled vortex flow, (2) tailored radial work distribution, and (3) control of the location of the boundary-layer transition point on the airfoil suction surface. The efficiency forecast for the 4 1/2 stage turbine was 0.886, and the value predicted using a reference method was 0.862. The stage group performance results were used to determine the individual stage efficiencies for the condition at which design 4 1/2 stage work output was obtained. The efficiencies of stages one and four were about 0.020 lower than the predicted value, that of stage two was 0.014 lower, and that of stage three was about equal to the predicted value. Thus all the stages operated reasonably close to their expected performance levels, and the overall (4 1/2 stage) performance was not degraded by any particularly inefficient component.

Whitney, W. J.↗

Reference material manufacture and certification for the AVNG

Testing and demonstration of any radiation measurement system requires the use of appropriate radioactive sources. An attribute measurement system (A VNG) was developed and fabricated at the Russian Federal Nuclear Center, VNIIEF, Russia, under contract with LANL, USA. The A VNG detects neutron and gamma radiation signatures and compares the data analysis results with the specified threshold values for three unclassified attributes; plutonium is present or absent, plutonium mass is greater than or less than the specified threshold value and plutonium isotopic ratio 240 Pu to 239 Pu) is greater than or less then the threshold value. A set of reference materials (RMs) was specially manufactured for the A VNG with masses and isotopic ratios above and below the selected thresholds. The set of RMs was certified in compliance with the Russian metrological requirements. The RMs were used to debug and test the A VNG and to demonstrate the A VNG operation to an American delegation in June 2009. In this presentation, we will describe the various steps in the manufacture and certification of these RM sources.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Coupling of nitric acid digestion and anion-exchange resin separation for the determination of methylmercury isotopic composition within organisms

Isotope ratios of methylmercury (MeHg) within organisms can be used to identify sources of MeHg that have accumulated in food webs, but these isotopic compositions are masked in organisms at lower trophic levels by the presence of inorganic mercury (iHg). To facilitate measurement of MeHg isotope ratios in organisms, we developed a method of extracting and isolating MeHg from fsh and aquatic invertebrates for compound-specifc isotopic analysis involving nitric acid digestion, batch anion-exchange resin separation, and pre-concentration by purge and trap. Recovery of MeHg was quantifed after each step in the procedure, and the average cumulative recovery of MeHg was 93.4±2.9% (1 SD, n=28) for biological reference materials and natural biota samples and 96.9±1.8% (1 SD, n=5) for aqueous MeHgCl standards. The amount of iHg impurities was also quantifed after each step, and the average MeHg purity was 97.8±4.3% (1 SD, n=28) across all reference materials and natural biota samples after the fnal separation step. Measured MeHg isotopic compositions of reference materials agreed with literature values obtained using other MeHg separation techniques, and MeHg isotope ratios of aqueous standards, reference materials, and natural biota samples were reproducible. On average, the reproducibility associated with reference material process replicates (2 SD) was 0.10‰ for δ 202 MeHg and 0.04‰ for Δ 199 MeHg. This new method provides a streamlined, reliable technique that utilizes a single sample aliquot for MeHg concentration and isotopic analysis. Furthermore, this promotes a tight coupling between MeHg concentration, %MeHg, and Hg isotopic composition, which may be especially benefcial for studying complex food webs with multiple isotopically distinct sources of iHg and/or MeHg.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗