SEARCH · Engineering Papers
Results for “Reactor Experiment”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Cavity reactor gas-core critical experiment
Critical experiment for cavity reactor using gaseous uranium hexafluoride core configuration
Lessons Learned About Liquid Metal Reactors From FFTF Experience
Explore the source record for details and available documents.
Comparing Sensitivity/Uncertainty Analysis Results for LR-0 Salt Experiments with Salt Reactor Models
Explore the source record for details and available documents.
Irradiation Testing of Nuclear Flux Sensors - Presentation for 2021 ASI Annual Webinar
This power point presentation is a summary of the work produced in FY2021 under the Irradiation Testing of Neutron Flux Sensors project funded by DOE's Advanced Sensor Initiative, and the outlook for FY22. The objective of this portion of the ASI program is to "Test and demonstrate in-pile instrumentation in conditions similar to those expected to be seen in service, i.e., the conditions they would see in either in irradiation experiments supporting advanced reactors, or ultimately, in advanced reactors themselves". The presentation describes how neutron flux sensors were tested in four INL reactors plus Idaho State University's research reactor during FY2021, and the results obtained from these tests.
Safeguards and Security by Design for Advanced Reactors: An Interactive Experience
Explore the source record for details and available documents.
Design of the Next Generation Nuclear Plant Graphite Creep Experiments for Irradiation in the Advanced Test Reactor
The United States Department of Energy’s Next Generation Nuclear Plant (NGNP) Program will be irradiating six gas reactor graphite creep experiments in the Advanced Test Reactor (ATR) located at the Idaho National Laboratory (INL). The ATR has a long history of irradiation testing in support of reactor development and the INL has been designated as the new United States Department of Energy’s lead laboratory for nuclear energy development. The ATR is one of the world’s premiere test reactors for performing long term, high flux, and/or large volume irradiation test programs. These graphite irradiations are being accomplished to support development of the next generation reactors in the United States. The graphite experiments will be irradiated over the next six to eight years to support development of a graphite irradiation performance data base on the new nuclear grade graphites now available for use in high temperature gas reactors. The goals of the irradiation experiments are to obtain irradiation performance data at different temperatures and loading conditions to support design of the Next Generation Nuclear Plant Very High Temperature Gas Reactor, as well as other future gas reactors. The experiments will each consist of a single capsule that will contain seven separate stacks of graphite specimens. Six of the specimen stacks will have half of their graphite specimens under a compressive load, while the other half of the specimens will not be subjected to a compressive load during irradiation. The six stacks will be organized into pairs with a different compressive load being applied to the top half of each pair of specimen stacks. The seventh stack will not have a compressive load on the graphite specimens during irradiation. The specimens will be irradiated in an inert sweep gas atmosphere with on-line temperature and compressive load monitoring and control. There will also be the capability of sampling the sweep gas effluent to determine if any oxidation or off-gassing of the specimens occurs during initial start-up of the experiment. The final design phase for the first experiment was completed in September 2008, and the fabrication and assembly of the experiment test train as well as installation and testing of the control and support systems that will monitor and control the experiment during irradiation are being completed in early calendar 2009. The first experiment is scheduled to be ready for insertion in the ATR by April 30, 2009. This paper will discuss the design of the experiment including the test train and the temperature and compressive load monitoring, control, and data collection systems.
Neutron Fluence and Kerma Responses to Bare, Steel-Reflected, and Lucite-Reflected Steady-State Operations of the ORNL Health Physics Research Reactor
The experiments evaluated in this report were conducted at the Health Physics Research Reactor (HPRR), also known as the Fast Burst Reactor. The reactor was designed and built at Oak Ridge National Laboratory (ORNL) in 1961. In this evaluation, a total of 12 experiments were evaluated (6 shield configurations and two responses). Six of them are considered acceptable as benchmark experiments and are thoroughly described: the measurands are bare, steel-shielded and Lucite-shielded neutron fluences and neutron KERMA responses to steady-state operations of the HPRR. It is important to mention that there is a general lack of information in the experimental methodology and neutron spectrum unfolding, and in some cases, unexpected and unexplained discrepancies between calculation and experiment. The HPRR’s unique characteristics were that it is a fast reactor, the use of a Lucite shield as the shielding material, and the use of the neutron fluence as the main benchmark measurand. There are no known, significant correlations between benchmarks in this evaluation and benchmarks in other evaluations.
Sulfur Pellets Responses to a Bare and Steel Reflected Pulse of the Oak Ridge National Laboratory Health Physics Research Reactor
The experiments analyzed in this report were conducted at the Health Physics Research Reactor (HPRR), also known as the $\textit{Fast Burst Reactor}$. The reactor was designed and built at Oak Ridge National Laboratory (ORNL) in 1961. The HPRR was an unmoderated, unshielded fast reactor that used highly enriched uranium and molybdenum alloy as fuel. The reactor was initially sent to the Nevada Test Site in 1962, where it was used to evaluate radiation doses received as a result of the Hiroshima and Nagasaki bombings during World War II. A few years later, the reactor was sent back to ORNL to be part of the Dosimetry Application Research (DOSAR) facility shown in Figure 1, which included a reactor building shown on the left (west) of the picture and a control and laboratory building in the upper right corner (northeast). The critical assembly was used for numerous technical studies, including systems calibration, dosimetry, radiobiology of plants and animals, testing of radiation alarms, as well as teaching and training in radiation dosimetry and nuclear engineering. Between 1963 and 1987, the HPRR was operated for thousands of hours, achieving criticality close to 10,000 times and motivating many publications. The HPRR was decommissioned in 1987. The goal of this effort was to use historical data from operation of the HPRR to create a criticality accident alarm system (CAAS) benchmark to be included in the $\textit{International Handbook of Evaluated Criticality Safety Benchmark Experiments}$ (ICSBEP Handbook). A thorough inspection was performed of all available documentation and information available. The most promising experiments that were selected for evaluation were those described in the 1987 ORNL report entitled $\textit{Health Physics Research Reactor Reference Dosimetry}$, ORNL-6240. The report includes reference dosimetry results of the shielded and unshielded configurations of the HPRR after burst operations. Because of changes to the reactor positioning and storage systems that were made in 1985, the previous dosimetry reports became obsolete, and the newly designed experiments were needed to create the HPRR’s adjusted dosimetry data. The various results reported in ORNL-6240 include reference doses and dose equivalents from different conventions at different distances and elevations as determined using the detected neutron fluence and conversion factors. The HPRR neutron fluence was obtained through different methods, including sulfur pellet analysis and threshold detector unit data. Information about the HPRR spectrum was also obtained through Bonner sphere measurements. This benchmark is focused on a part of the measured sulfur fluences reported in Appendix H of ORNL-6240. Standard commercial sulfur pellets were placed at different distances from the HPRR centerline during burst operation and were activated due to the 32 S(n,p) 32 P reaction. The resulting 32 P activity was then measured and the information about the corresponding sulfur fluence and/or neutron dose could be extracted. Many of those measurements have 7 been performed with the HPRR in its bare configuration or with different shields (combinations of Lucite, concrete, steel). All the necessary, precise information about material and/or dimensions of the different shields was not found, so it was decided to focus only on the unshielded and steel-shielded configurations to minimize the benchmark uncertainty. A total of 31 cases (24 unshielded and 7 shielded cases at different positions) of sulfur fluence were selected before evaluation to develop the benchmark.
Preliminary Designs for Criticality Safety Benchmarks—Iron/Steel/Chromium Series
The nuclear criticality safety community uses critical benchmarks extensively when analyzing nuclear systems. Having benchmarks sensitive to important materials of interest helps to ensure safety and constrain results. Critical benchmarks are also invaluable to the nuclear data community, which uses these benchmarks as a check and measure of quality of nuclear data libraries. Additionally, integral benchmarks are often used to validate the performance of computational tools for simulating nuclear systems. Many integral benchmarks have been documented in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) handbook, the International Reactor Physics Experiment Evaluation Project (IRPhEP) handbook, and the Shielding Integral Benchmark Archive Database (SINBAD). The National Criticality Experiments Research Center (NCERC), operated by Los Alamos National Laboratory, is the only general purpose critical experiments facility in the United States of America. NCERC regularly designs and executes critical experiments and other measurements useful to a wide variety of fields including nuclear criticality safety, commercial nuclear energy, nonproliferation, and nuclear data. NCERC has recently developed tools to visualize gaps and deficiencies in existing criticality benchmarks – this work is still ongoing. Through this work and other reviews, some high priority deficiencies have been identified. This paper aims to highlight three areas where additional critical benchmarks would be useful to the nuclear criticality safety community and various other groups. Additionally, NCERC is seeking feedback in regard to these proposed measurements to make sure they are as useful to as many communities as possible.
The 2018 Edition of the IRPhEP Handbook
The International Reactor Physics Experiment Evaluation Project (IRPhEP) was established to preserve and evaluate integral reactor physics experiment data, including separate or special effects measurements for nuclear energy and technology applications. Numerous international experiments have been performed over the past several decades to support reactor operations, safety, measurements, and design. Those experiments represent a significant investment of infrastructure, cost, and expertise that, in many instances, cannot be as easily reproduced. They represent valuable resources of data for present and future research, and provide the basis for recording, development, and validation of methods. Contributors worldwide collaborate to evaluate and review selected benchmark experiments for inclusion in the International Handbook of Evaluated Reactor Physics Benchmark Experiments (IRPhEP Handbook). Several new evaluations, and revisions to existing benchmarks have been prepared for inclusion in the 2018 edition of the IRPhEP Handbook. Additionally, an IRPhEP Uncertainty Guide was discussed to provide further guidance regarding the evaluation of reactor physics measurements besides criticality. Recent changes to the IRPhEP Handbook include five minor revisions, the revision of a previous benchmark evaluation to include new data, publication of a new draft benchmark evaluation, final approval for the formal publication of two formerly draft benchmark evaluations, and the inclusion of ten new benchmark evaluations. The IRPhEP Handbook now contains a total of 159 experimental measurement series from 54 unique reactor facilities. International participants are actively engaged in ongoing evaluation activities to prepare content for future editions of the IRPhEP Handbook. There are numerous experiment and reactor facilities worldwide from which benchmark data can be evaluated. Those interested in serving as evaluators and/or reviewers for the IRPhEP are encouraged to participate.
Benchmark Evaluation of TREAT Reactor M2 and M3 Transient Experiments
The objective of this project is to evaluate and produce TREAT reactor benchmarks under steady state and transient conditions. The benchmarks support the TREAT restart effort and are to be contributed to the International Reactor Physics Experiment Evaluation Project (IRPhEP) for inclusion in the International Handbook of Evaluated Reactor Physics Benchmark Experiments. The benchmark evaluation is performed using data generated during the “Power Calibration Experiment for test M2” and “IFR Safety Tests M2 and M3”. The evaluations are conducted using the high fidelity Serpent-OpenFOAM code system. Both the steady state and transient conditions of the M2 and M3 tests were investigated. Furthermore, TREAT has a graphitic core. Historical work has shown that the predictions of the outcomes of TREAT tests are highly sensitive to the graphite thermal neutron scattering cross sections. Therefore, in this project, thermal neutron scattering (i.e., S(α,β)) libraries of graphite, tailored to the specifics of the TREAT core, were generated and utilized in the evaluation
Irradiation system for cryogenic experiments in the Plum Brook Reactor
Irradiation system for cryogenic temperature experiments in Plum Brook Reactor
Quantity of 135 I released from the AGR-1, AGR-2, and AGR-3/4 experiments and discovery of 131 I at the FPMS traps during the AGR-3/4 experiment
A series of three Advanced Gas Reactor (AGR) experiments have been conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). From 2006 through 2014, these experiments supported the development and qualification of the new U.S. tristructural isotropic (TRISO) particle fuel for Very High Temperature Reactors (VHTR). Each AGR experiment consisted of multiple fueled capsules, each plumbed for independent temperature control using a mix of helium and neon gases. The gas leaving a capsule was routed to individual Fission Product Monitor (FPM) detectors. For intact fuel particles, the TRISO particle coatings provide a substantial barrier to fission product release. However, particles with failed coatings, whether because of a minute percentage of initially defective particles, those which fail during irradiation, or those designed to fail (DTF) particles, can release fission products to the flowing gas stream. Because reactive fission product elements like iodine and cesium quickly deposit on cooler capsule components and piping structures as the effluent gas leaves the reactor core, only the noble fission gas isotopes of Kr and Xe tend to reach FPM detectors. The FPM system utilizes High Purity Germanium (HPGe) detectors coupled with a thallium activated sodium iodide NaI(Tl) scintillator. The HPGe detector provides individual isotopic information, while the NaI(Tl) scintillator is used as a gross count rate meter. During irradiation, the 135m Xe concentration reaching the FPM detectors is from both direct fission and by decay of the accumulated 135 I. About 2.5 hours after irradiation (ten 15.3 minute 135m Xe half lives) the directly produced 135m Xe has decayed and only the longer lived 135 I remains as a source. Decay systematics dictate that 135m Xe will be in secular equilibrium with its 135 I parent, such that its production rate very nearly equals the decay rate of the parent, and its concentration in the flowing gas stream will appear to decay with the parent half life. This equilibrium condition enables the determination of the amount of 135 I released from the fuel particles by measurement of the 135m Xe at the FPM following reactor shutdown. In this paper, the 135 I released will be reported and compared to similar releases for noble gases as well as the unexpected finding of 131 I deposition from intentional impure gas injection into capsule 11 of experiment AGR 3/4.
Monte Carlo interpretation of the AMMON/REF experiment in EOLE for the JHR reactor calculations
A new experiment, named AMMON and dedicated to the analysis of the JHR neutron physics and to the qualification of the associated neutron calculation tools, is currently in progress in the EOLE zero-power experimental reactor at CEA Cadarache. The first core configuration, so called 'reference configuration' (AMMON/REF) has already been loaded: it consists of an experimental zone of 7 JHR assemblies with U{sub 3}Si{sub 2} 27% {sup 235}U enriched fuel curved plates surrounded by a driver zone with 623 standard PWR UOx fuel pins. The analysis of the AMMON/REF measurements is presented in this paper. It is based on calculations performed with the 3-dimensional reference Monte Carlo TRIPOLI4.7 code and the JEFF3.1.1 European library: it highlights a good agreement between calculation and experiment concerning reactivity and power distribution in the experimental zone. Reactivity prediction is very satisfactory, despite the presence of a large aluminum quantity in the core: C-E=+ 376 pcm {+-} 290. The radial and axial plate power profiles are also in good agreement. Assembly power distribution is predicted within the experimental uncertainties (1{sigma}). (authors)
Calculated analysis of experiments in fast neutron reactors
In this paper, the results of computational simulation of experiments with the MK-I core of the JOYO fast neutron sodium-cooled reactor are presented. The MCU-KS code based on the Monte Carlo method was used for calculations. The research was aimed at additional verification of the MCU-KS code for systems with a fast neutron spectrum.
Uranium–Molybdenum Alloy Critical Experiments for the Design of the Health Physics Research Reactor
Clean critical experiments with a uranium-molybdenum alloy (average of 10.1616 wt. % Mo with a density of 17.08 g/cm 3 ) were performed at the Oak Ridge Critical Experiments Facility in 1961 to support the design of the Health Physics Research Reactor (HPRR). The HPRR was similar to the Godiva burst reactor at Los Alamos National Laboratory and was designed to produce 50 microseconds burst of 10 17 fission pulses of radiation for dosimetry measurements, initially in support of the determination of the doses from the nuclear detonations in Japan during World War II. These experiments reported here were used to verify the calculational methods used to design the HPRR. These delayed critical measurements were:1) a solid unreflected and unmoderated 8-in.-dimeter U-Mo cylinder, 2) an unmoderated and unreflected annulus with 8-in.-outside diameter, 2-in.-inside diameter cylinder with a central void, 3) an unmoderated and unreflected annulus with 8-in.-outside diameter, 2-in.-inside diameter cylinder with a central void filled with stainless steel, 4) Same as 3) but with 3-in-thick Plexiglas reflector on top with and without cadmium between the reflector and the U-Mo alloy assembly with steel in the center, and 5) an unmoderated and unreflected annulus which was a modification of the second but with the lower 5 inches of the central hole enlarged to 3.5 in. with various reflector conditions. The reflector conditions were: 1-in.-thick Plexiglas on all outer surfaces-void in the center; 1-in.-thick Plexiglas on all outer surfaces-Plexiglas in the center; 2-in.- thick Plexiglas on radial surface-void in the center; 6-in.-thick Plexiglas on the bottom only-Plexiglas in the center; and 6-in.-thick Plexiglas on bottom, 1-in.-thick on top and on the lower 8.25-cm.-section of the radial surface-void in the center. For some of these reflector conditions 0.025-cm.thick cadmium was located between the reflector and the U-Mo alloy. The uranium contained 93.17 wt. % 235 U. Reflection was a safety concern for this unmoderated and unreflected reactor and reduction of reflection effects was also investigated by insertion of neutron absorber around the U-Mo alloy. The stainless steel 304 contained 18% nickel and 8% chromium and the rest iron. The reflector material was a methacrylate plastic (Plexiglas) containing 5.8 x 10 22 atoms/cm 3 of hydrogen and 3.6 x 10 22 atoms/cm 3 of carbon with a density of 1.20 g/cm 3 . The purpose of this report is to document the experimental information for the measurements performed so that at a later date researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Program (ICSBEP) or a EURATON Nuclear Energy Agency (NEA) benchmark. The data from the experiments described should be acceptable for use as criticality safety benchmark experiments for the ICSBEP and the NEA nuclear criticality safety benchmark program, once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, the uncertainties in k eff could be as low as ±0.0002 for some configurations.
Contribution to the IRPHEP handbook since Physor 2018
The Organisation for Economic Co-operation and Development (OECD), the Nuclear Energy Agency (NEA), the International Reactor Physics Experiment Evaluation Project (IRPhEP) continue to preserve and evaluate integral reactor physics experiment data to support nuclear energy and technology needs. International contributions are collated within the International Handbook of Evaluated Reactor Physics Benchmark Experiments (IRPhEP Handbook). The 2021 edition of the IRPhEP Handbook now contains data for 57 unique nuclear facilities with benchmark specifications for 169 experimental series, of which four are draft evaluations. Distributed with the IRPhEP Handbook and available online is the IRPhEP Database and Analysis Tool (IDAT), allowing users to search and interrogate the data. Since Physor 2018, there have been 11 minor revisions to existing benchmark evaluations, significant revisions to two evaluations, one draft evaluation, and nine new evaluations. The corona virus pandemic has delayed international activities supporting the production of additional content for the IRPhEP Handbook. However, efforts continue for numerous endeavors to complete new reactor physics benchmark evaluations to support current and future validation needs. Those interested in serving as evaluators and/or reviewers are strongly encouraged to participate. This paper provides a summary of IRPhEP content and activities since Physor 2018. (authors)