Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Environment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Classifying photonic topology using the spectral localizer and numerical K -theory

Recently, the spectral localizer framework has emerged as an efficient approach for classifying topology in photonic systems featuring local nonlinearities and radiative environments. In nonlinear systems, this framework provides rigorous definitions for concepts such as topological solitons and topological dynamics, where a system’s occupation induces a local change in its topology due to nonlinearity. For systems embedded in radiative environments that do not possess a shared bulk spectral gap, this framework enables the identification of local topology and shows that local topological protection is preserved despite the lack of a common gap. However, as the spectral localizer framework is rooted in the mathematics of C*-algebras, and not vector bundles, understanding and using this framework requires developing intuition for a somewhat different set of underlying concepts than those that appear in traditional approaches for classifying material topology. In this tutorial, we introduce the spectral localizer framework from a ground-up perspective and provide physically motivated arguments for understanding its local topological markers and associated local measure of topological protection. In doing so, we provide numerous examples of the framework’s application to a variety of topological classes, including crystalline and higher-order topology. We then show how Maxwell’s equations can be reformulated to be compatible with the spectral localizer framework, including the possibility of radiative boundary conditions. To aid in this introduction, we also provide a physics-oriented introduction to multi-operator pseudospectral methods and numerical K-theory, two mathematical concepts that form the foundation for the spectral localizer framework. Finally, we provide some mathematically oriented comments on the C*-algebraic origins of this framework, including a discussion of real C*-algebras and graded C*-algebras that are necessary for incorporating physical symmetries. Looking forward, we hope that this tutorial will serve as an approachable starting point for learning the foundations of the spectral localizer framework.

97 MATHEMATICS AND COMPUTING↗

Radiation Hardened Electronics for Extreme Environments

The Radiation Hardened Electronics for Space Environments (RHESE) project consists of a series of tasks designed to develop and mature a broad spectrum of radiation hardened and low temperature electronics technologies. Three approaches are being taken to address radiation hardening: improved material hardness, design techniques to improve radiation tolerance, and software methods to improve radiation tolerance. Within these approaches various technology products are being addressed including Field Programmable Gate Arrays (FPGA), Field Programmable Analog Arrays (FPAA), MEMS Serial Processors, Reconfigurable Processors, and Parallel Processors. In addition to radiation hardening, low temperature extremes are addressed with a focus on material and design approaches.

Keys, Andrew S.↗

Technology Developments in Radiation-Hardened Electronics for Space Environments

The Radiation Hardened Electronics for Space Environments (RHESE) project consists of a series of tasks designed to develop and mature a broad spectrum of radiation hardened and low temperature electronics technologies. Three approaches are being taken to address radiation hardening: improved material hardness, design techniques to improve radiation tolerance, and software methods to improve radiation tolerance. Within these approaches various technology products are being addressed including Field Programmable Gate Arrays (FPGA), Field Programmable Analog Arrays (FPAA), MEMS, Serial Processors, Reconfigurable Processors, and Parallel Processors. In addition to radiation hardening, low temperature extremes are addressed with a focus on material and design approaches. System level applications for the RHESE technology products are discussed.

Keys, Andrew S.↗

Competing effects of electronic and nuclear energy loss on microstructural evolution in ionic-covalent materials

Ever increasing energy needs have raised the demands for advanced fuels and cladding materials that withstand the extreme radiation environments with improved accident tolerance over a long period of time. Ceria (CeO2) is a well known ionic conductor that is isostructural with urania and plutonia-based nuclear fuels. In the context of nuclear fuels, immobilization and transmutation of actinides, CeO2 is a model system for radiation effect studies. Covalent silicon carbide (SiC) is a candidate for use as structural material in fusion, cladding material for fission reactors, and an inert matrix for the transmutation of plutonium and other radioactive actinides. Understanding microstructural change of these ionic-covalent materials to irradiation is important for advanced nuclear energy systems. While displacements from nuclear energy loss may be the primary contribution to damage accumulation in a crystalline matrix and a driving force for the grain boundary evolution in nanostructured materials, local non-equilibrium disorder and excitation through electronic energy loss may, however, produce additional damage or anneal pre-existing defects. At intermediate transit energies where electronic and nuclear energy losses are both significant, synergistic, additive or competitive processes may evolve that affect the dynamic response of materials to irradiation. The response of crystalline and nanostructured CeO2 and SiC to ion irradiation are studied under different nuclear and electronic stopping powers to describe some general material response in this transit energy regime. Although fast radiation-induced grain growth in CeO2 is evident with no phase transformation, different fluence and dose dependence on the growth rate is observed under Si and Au irradiations. While grain shrinkage and amorphization are observed in the nano-engineered 3C SiC with a high-density of stacking faults embedded in nanosize columnar grains, significantly enhanced radiation resistance is attributed to stacking faults that promote efficient point defect annihilation. Moreover, competing effects of electronic and nuclear energy loss on the damage accumulation and annihilation are observed in crystalline 4H-SiC. Systematic experiments and simulation effort are needed to understand the competitive or synergistic effects.

36 MATERIALS SCIENCE↗

Commercial Off-The-Shelf (COTS) Graphics Processing Board (GPB) Radiation Test Evaluation Report

Large round trip communications latency for deep space missions will require more onboard computational capabilities to enable the space vehicle to undertake many tasks that have traditionally been ground-based, mission control responsibilities. As a result, visual display graphics will be required to provide simpler vehicle situational awareness through graphical representations, as well as provide capabilities never before done in a space mission, such as augmented reality for in-flight maintenance or Telepresence activities. These capabilities will require graphics processors and associated support electronic components for high computational graphics processing. In an effort to understand the performance of commercial graphics card electronics operating in the expected radiation environment, a preliminary test was performed on five commercial offthe- shelf (COTS) graphics cards. This paper discusses the preliminary evaluation test results of five COTS graphics processing cards tested to the International Space Station (ISS) low earth orbit radiation environment. Three of the five graphics cards were tested to a total dose of 6000 rads (Si). The test articles, test configuration, preliminary results, and recommendations are discussed.

Salazar, George A.↗

Assessment of the Influence of the RaD-X Balloon Payload on the Onboard Radiation Detectors

The NASA Radiation Dosimetry Experiment (RaD-X) stratospheric balloon flight mission, launched on 25 September 2015, provided dosimetric measurements above the Pfotzer maximum. The goal of taking these measurements is to improve aviation radiation models by providing a characterization of cosmic ray primaries, which are the source of radiation exposure at aviation altitudes. The RaD-X science payload consists of four instruments. The main science instrument is a tissue-equivalent proportional counter (TEPC). The other instruments consisted of three solid state silicon dosimeters: Liulin, Teledyne total ionizing dose (TID) and RaySure detectors. The instruments were housed in an aluminum structure protected by a foam cover. The structure partially shielded the detectors from cosmic rays but also created secondary particles, modifying the ambient radiation environment observed by the instruments. Therefore, it is necessary to account for the influence of the payload structure on the measured doses. In this paper, we present the results of modeling the effect of the balloon payload on the radiation detector measurements using a Geant-4 (GEometry ANd Tracking) application. Payload structure correction factors derived for the TEPC, Liulin, and TID instruments are provided as a function of altitude. Overall, the payload corrections are no more than a 7% effect on the radiation environment measurements.

Gronoff, Guilluame↗

Solar Array Verification Analysis Tool (SAVANT) Developed

Modeling solar cell performance for a specific radiation environment to obtain the end-of-life photovoltaic array performance has become both increasingly important and, with the rapid advent of new types of cell technology, more difficult. For large constellations of satellites, a few percent difference in the lifetime prediction can have an enormous economic impact. The tool described here automates the assessment of solar array on-orbit end-of-life performance and assists in the development and design of ground test protocols for different solar cell designs. Once established, these protocols can be used to calculate on-orbit end-of-life performance from ground test results. The Solar Array Verification Analysis Tool (SAVANT) utilizes the radiation environment from the Environment Work Bench (EWB) model developed by the NASA Lewis Research Center s Photovoltaic and Space Environmental Effects Branch in conjunction with Maxwell Technologies. It then modifies and combines this information with the displacement damage model proposed by Summers et al. (ref. 1) of the Naval Research Laboratory to determine solar cell performance during the course of a given mission. The resulting predictions can then be compared with flight data. The Environment WorkBench (ref. 2) uses the NASA AE8 (electron) and AP8 (proton) models of the radiation belts to calculate the trapped radiation flux. These fluxes are integrated over the defined spacecraft orbit for the duration of the mission to obtain the total omnidirectional fluence spectra. Components such as the solar cell coverglass, adhesive, and antireflective coatings can slow and attenuate the particle fluence reaching the solar cell. In SAVANT, a continuous slowing down approximation is used to model this effect.

Bailey, Sheila G.↗

Instrumentation for investigation of the depth-dose distribution by the Liulin-5 instrument of a human phantom on the Russian segment of ISS for estimation of the radiation risk during long term space flights

Described is the Liulin-5 experiment and instrumentation, developed for investigation of the space radiation doses depth distribution in a human phantom on the Russian Segment of the International Space Station (ISS). Liulin-5 experiment is a part of the international project MATROSHKA-R on ISS. The experiment MATROSHKA-R is aimed to study the depth dose distribution at the sites of critical organs of the human body, using models of human body-anthropomorphic and spherical tissue-equivalent phantoms. The aim of Liulin-5 experiment is long term (4-5 years) investigation of the radiation environment dynamics inside the spherical tissue-equivalent phantom, mounted in different places of the Russian Segment of ISS. Energy deposition spectra, linear energy transfer spectra, flux and dose rates for protons and the biologically-relevant heavy ion components of the galactic cosmic radiation will be measured simultaneously with near real time resolution at different depths of the phantom by a telescope of silicon detectors. Data obtained together with data from other active and passive dosimeters will be used to estimate the radiation risk to the crewmembers, verify the models of radiation environment in low Earth orbit, validate body transport model and correlate organ level dose to skin dose. Presented are the test results of the prototype unit. The spherical phantom will be flown on the ISS in 2004 year and Liulin-5 experiment is planned for 2005 year. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.

Cosmic Radiation↗

RadLab: A Comprehensive Database and Graphical and Programming Interfaces for Biologically Relevant Space Radiation Data

RadLab, a new component of the NASA Open Science Data Repository (OSDR), comprises a database of radiation measurements relevant to space biology, and visual and programmatic interfaces for interrogation and retrieval of these data. The attributes of data available through RadLab include spacecraft, types of radiation sensing instruments, locations within the spacecraft (e.g. modules of the ISS), associated celestial bodies, trajectories, and spacecraft coordinates. The application programming interface (API) implements a request syntax for retrieval of timestamped data filtered by various combinations of such attributes; the graphical user interface (GUI) extends this functionality with visualizations, such as spacecraft schematics, time series plots, geospatial visualizations, and provides easy means to iteratively refine search parameters, inspect the data on the fly, and download target subsets. The release of RadLab currently available to the public contains datasets provided by US and international collaborators and focuses on data recorded on the ISS. Investigators from multiple countries, including the US, Canada, Germany, Bulgaria, Hungary, Italy, Japan, Russia and the Czech Republic, have committed to provide data from their instruments in and beyond low Earth orbit; RadLab will also soon expand to include past (e.g. Shuttle and Mir) and future (e.g. Artemis) data. RadLab will provide a comprehensive, dynamic compendium of space radiation data, enabling the scientific community to perform analyses of data from multiple detectors and to determine the radiation environment of research missions and experiments. The RadLab Working Group has been formed to foster collaborations among data contributors and users, to identify data sources, to put in place standards for data harmonization, and to guide the development of the platform, with the goal to establish the use of RadLab in space radiation research and to advance our understanding of the space radiation environment in human habitats.

database↗

A signal packet router for the upgrade of the Muon spectrometer at the ATLAS experiment

Here, we present the design, characterization, and production of a signal packet router for the upgrade of the ATLAS forward muon detector. The router serves as a packet switch in one of the primary trigger paths. It handles up to 12 serial inputs at 4.8 Gbps/input from on-detector electronics and outputs four 4.8 Gbps to the trigger processing circuits. In the 12-to-4 packet switching process, the input streams are decoded and synchronized to a common clock domain for data packets forwarding and NULL packets suppression. Challenges in the design include operations of multi-giga hertz serial links with low and constant latency (<100 ns) for packet routing, as well as mitigation of radiation-induced effects in the harsh radiation environment over 10 years of detector operation. The Router design has been fully characterized and demonstrated to meet all specifications. In total 256 Routers were installed in the detector. Its design concept can be used in other similar applications, particularly in a radiation environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Raman Spectroscopy as an ortho-para diagnostic of liquid hydrogen moderators

The intense radiation environment of a neutron moderator provides a mechanism for significant up-conversion of parahydrogen to orthohydrogen inside the moderator, as well as intrinsically catalyzing relaxation of orthohydrogen to parahydrogen. It is plausible that the steady-state orthohydrogen fraction of a moderator in a radiation environment such as at the Spallation Neutron Source (SNS) or the European Spallation Source (ESS) is as high as 30 % without supplemental catalysis. Direct measurement of the orthohydrogen fraction in the liquid hydrogen flow itself is essential to predict and monitor moderator performance, especially for thick or flat moderator concepts such as the ones that have been proposed for the ESS and for upgrades to the SNS. Raman spectroscopy provides a well-known method for directly measuring the hydrogen make-up in an unambiguous way. We describe our tests of Raman spectroscopy for application to the measurement of the orthohydrogen fraction of the hydrogen moderators at SNS and at the ESS. As part of this work, we have additionally developed a sample holder that has been used to perform simultaneous Raman and neutron vibrational spectroscopy on the VISION spectrometer at SNS. We discuss our plans to incorporate such a system as a diagnostic for liquid hydrogen moderators at SNS and at the ESS.

Gillis, Robert Chad↗

Saturn radiation (SATRAD) model

The Saturnian radiation belts have not received as much attention as the Jovian radiation belts because they are not nearly as intense—the famous Saturnian particle rings tend to deplete he belts near where their peak would occur. As a result, there has not been a systematic development of engineering models of the Saturnian radiation environment for mission design. A primary exception is that of Divine (1990). That study used published data from several charged particle experiments aboard the Pioneer 11, Voyager 1, and Voyager 2 spacecraft during their flybys at Saturn to generate numerical models for the electron and proton radiation belts between 2.3 and 13 Saturn radii. The Divine Saturn radiation model described the electron distributions at energies between 0.04 and 10 MeV and the proton distributions at energies between 0.14 and 80 MeV. The model was intended to predict particle intensity, flux, and fluence for the Cassini orbiter. Divine carried out hand calculations using the model but never formally developed a computer program that could be used for general mission analyses. This report seeks to fill that void by formally developing a FORTRAN version of the model that can be used as a computer design tool for missions to Saturn that require estimates of the radiation environment around the planet. The results of that effort and the program listings are presented here along with comparisons with the original estimates carried out by Divine. In addition, Pioneer and Voyager data were scanned in from the original references and compared with the FORTRAN model’s predictions. The results were statistically analyzed in a manner consistent with Divine’s approach to provide estimates of the ability of the model to reproduce the original data. Results of a formal review of the model by a panel of experts are also presented. Their recommendations for further tests, analyses, and extensions to the model are discussed.

Evans, R. W.↗

Closed Brayton Cycle Power Conversion Unit for Fission Surface Power Phase I Final Report

A Closed Brayton cycle power conversion system has been developed to support the NASA fission surface power program. The goal is to provide electricity from a small nuclear reactor heat source for surface power production for lunar and Mars environments. The selected media for a heat source is NaK 78 with water as a cooling source. The closed Brayton cycle power was selected to be 12 kWe output from the generator terminals. A heat source NaK temperature of 850 K plus or minus 25 K was selected. The cold source water was selected at 375 K plus or minus 25 K. A vacuum radiation environment of 200 K is specified for environmental operation. The major components of the system are the power converter, the power controller, and the top level data acquisition and control unit. The power converter with associated sensors resides in the vacuum radiation environment. The power controller and data acquisition system reside in an ambient laboratory environment. Signals and power are supplied across the pressure boundary electrically with hermetic connectors installed on the vacuum vessel. System level analyses were performed on working fluids, cycle design parameters, heater and cooling temperatures, and heat exchanger options that best meet the needs of the power converter specification. The goal is to provide a cost effective system that has high thermal-to-electric efficiency in a compact, lightweight package.

Fuller, Robert L.↗

Comparison of KENO-VI and MCNP5 Criticality Analyses for a Lunar Regolith Clustered-Reactor System

The Lunar Regolith Clustered-Reactor System design has been presented as an alternative method for providing surface power to a lunar facility using a fast-fission, heatpipe-cooled nuclear reactor. The reactor system is divided into subcritical units that can be safely launched into orbit without risk of inadvertent criticality in the event of a launch accident. The reactor subunits are emplaced into the lunar surface to form a clustered-reactor system, utilizing the regolith as both radiation shielding and neutron-reflector material. Coordinated placement of multiple subunits can provision a critical reactor system proportional to localized lunar surface power demand. Reactor units assembled using proven and tested materials in radiation environments such as UO{sub 2} fuel, stainless-steel cladding and support, and compatible liquid-metal heatpipes promote safety and reliability, with ease of manufacture and testing. Reactor power levels of approximately 100 kWth per subunit significantly reduces the negative effects of elevated temperature and radiation environments associated with single nuclear power reactors operated at higher power levels. The analysis of subunit criticality in various accident scenarios differs by up to 4% ({approx}$6 in reactivity) between results generated using conventional criticality analysis codes, MCNP5 and KENO-VI. A demonstrated trend exists between results of the two criticality codes as accident conditions approach a multiplication factor of one. Code comparison of a tri-cluster system on the lunar surface provides comparable results with calculated system reactivity within 0.5%. Iron concentration is confirmed as the dominant element in the lunar regolith influencing system reactivity.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Saturn Radiation (SATRAD) Model

The Saturnian radiation belts have not received as much attention as the Jovian radiation belts because they are not nearly as intense-the famous Saturnian particle rings tend to deplete the belts near where their peak would occur. As a result, there has not been a systematic development of engineering models of the Saturnian radiation environment for mission design. A primary exception is that of Divine (1990). That study used published data from several charged particle experiments aboard the Pioneer 1 1, Voyager 1, and Voyager 2 spacecraft during their flybys at Saturn to generate numerical models for the electron and proton radiation belts between 2.3 and 13 Saturn radii. The Divine Saturn radiation model described the electron distributions at energies between 0.04 and 10 MeV and the proton distributions at energies between 0.14 and 80 MeV. The model was intended to predict particle intensity, flux, and fluence for the Cassini orbiter. Divine carried out hand calculations using the model but never formally developed a computer program that could be used for general mission analyses. This report seeks to fill that void by formally developing a FORTRAN version of the model that can be used as a computer design tool for missions to Saturn that require estimates of the radiation environment around the planet. The results of that effort and the program listings are presented here along with comparisons with the original estimates carried out by Divine. In addition, Pioneer and Voyager data were scanned in from the original references and compared with the FORTRAN model s predictions. The results were statistically analyzed in a manner consistent with Divine s approach to provide estimates of the ability of the model to reproduce the original data. Results of a formal review of the model by a panel of experts are also presented. Their recommendations for further tests, analyses, and extensions to the model are discussed.

Garrett, H. B.↗

Final Report on Radiation Measurements Performed Inside of the BEAM Module

Measurements of the radiation environment inside of the Bigelow Expandable Activity Module (BEAM) have been made on a pseudo-continuous basis since June 6, 2016 using both passive and active instrumentation. Passive detectors yield a single cumulative dose value (or average daily dose) over the measurement period from deploy to return to ground. Active Radiation Environment Monitor (REM) sensors yield dose rate, Linear Energy Transfer (LET) spectra, and particle-specific dose, all on a 1-minute cadence. From the initial install in 2016 until early 2018, BEAM was an empty module. In 2018, further testing was approved and stowage began to be moved into BEAM. As a result, it was decided to stop measurements with RAM detectors to avoid potential difficulties with access after stowage was added. The REM sensors remained however in the original deploy locations.

radiation exposure↗

RadLab: A Comprehensive Database and Graphical and Programming Interfaces for Biologically Relevant Space Radiation Data

RadLab, a new component of the NASA Open Science Data Repository (OSDR), comprises a database of radiation measurements relevant to space biology, and visual and programmatic interfaces for interrogation and retrieval of these data. The attributes of data available through RadLab include spacecraft, types of radiation sensing instruments, locations within the spacecraft (e.g. modules of the ISS), associated celestial bodies, trajectories, and spacecraft coordinates. The application programming interface (API) implements a request syntax for retrieval of timestamped data filtered by various combinations of such attributes; the graphical user interface (GUI) extends this functionality with visualizations, such as spacecraft schematics, time series plots, geospatial visualizations, and provides easy means to iteratively refine search parameters, inspect the data on the fly, and download target subsets of these data. The release of RadLab currently available to the public contains datasets provided by US and international collaborators and focuses on data recorded on the ISS. Investigators from multiple countries, including the US, Canada, Germany, Bulgaria, Hungary, Italy, Japan, Russia and the Czech Republic, have committed to provide data from their instruments in and beyond low Earth orbit; RadLab will also soon expand to include past (e.g. Shuttle and Mir) and future (e.g. Artemis) data. RadLab will provide a comprehensive, dynamic compendium of space radiation data, enabling the scientific community to perform analyses of data from multiple detectors and to determine the radiation environment of research missions and experiments, both via programmatic retrieval of these data and through the graphical analysis toolkit. The RadLab Working Group has been formed to foster collaborations among data contributors and users, to identify data sources, to put in place standards for data harmonization, and to guide the development of the platform, with the goal to establish the use of RadLab in space radiation research and to advance our understanding of the space radiation environment in human habitats.

radiation↗

High fidelity, radiation tolerant analog-to-digital converters

Techniques for an analog-to-digital converter (ADC) using pipeline architecture includes a linearization technique for a spurious-free dynamic range (SFDR) over 80 deciBels. In some embodiments, sampling rates exceed a megahertz. According to a second approach, a switched-capacitor circuit is configured for correct operation in a high radiation environment. In one embodiment, the combination yields high fidelity ADC (>88 deciBel SFDR) while sampling at 5 megahertz sampling rates and consuming <60 milliWatts. Furthermore, even though it is manufactured in a commercial 0.25-.mu.m CMOS technology (1 .mu.m=12.sup.-6 meters), it maintains this performance in harsh radiation environments. Specifically, the stated performance is sustained through a highest tested 2 megarad(Si) total dose, and the ADC displays no latchup up to a highest tested linear energy transfer of 63 million electron Volts square centimeters per milligram at elevated temperature (131 degrees C.) and supply (2.7 Volts, versus 2.5 Volts nominal).

Wang, Charles Chang-I↗