Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REFRIGERATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Review of Variable Geometry Air-to-Refrigerant Heat Exchangers

Air-to-refrigerant heat exchangers (HXs) are fundamental components to HVAC&R systems and as a result there is an ever-increasing need for performance and packaging improvements. Typically, HX’s are designed in uniform arrangements with the goal of providing the necessary heat transfer for minimal material costs. Recent research on fin tube heat exchangers (FTHX) with variation in one or more key parameters has shown significant potential for increasing heat transfer, reducing pressure losses, and making HXs more resilient to environmental externalities like airflow maldistribution and frost accumulation. In particular, researchers have increased heat transfer by 7.6% and j/f by 16% via non-uniform tube and winglet shapes. Additionally, multiple cases have shown that variable geometry heat exchangers (VGHX) are able to match the performance of conventional HXs with reductions in material mass and envelope volume of up to 33% and 40%, respectively. This paper presents a literature review of VGHXs specifically with regards to non-uniform FTHX’s.

42 ENGINEERING↗

Heat transfer and visual observation of pool boiling of next-generation low-pressure refrigerant: R1336mzz(Z)

R1336mzz(Z) is a non-flammable and non-toxic hydrofluoroolefin (HFO), which is a potential alternative working fluid for multiple applications such as centrifugal chillers, industrial high temperature heat pumps, and Organic Rankine Cycles. Pool boiling is one of the primary heat transfer modes in shell-and-tube evaporators, and there is limited data for R1336mzz(Z) due to its recent introduction. This study investigated the pool boiling characteristics of R1336mzz(Z) using a closed-loop apparatus. Heat transfer coefficients on a smooth aluminum surface were measured at various heat fluxes with a heating block, and the results were compared to predictions from various correlations. Additionally, a high-speed camera was employed to visualize and analyze the pool boiling behavior of this next-generation low-pressure refrigerant.

Yang, Cheng-Min [ORNL]↗

Design of Standards and Labeling programs in Chile: Techno-Economic Analysis for Refrigerators

Lawrence Berkeley National Laboratory is a global leader in the study of energy efficiency and its effective implementation through government policy. The Energy Analysis and Environmental Impacts Department of LBNL’s Environmental Energy Technologies Division provides technical assistance to help federal, stat e and local government agencies in the United States, and throughout the world, develop long-term strategies, policy, and programs to encourage energy efficiency in all sectors and industries. In the past, LBNL has assisted staff of various countries government agencies and their con tractors in providing methodologies to analyze cost-effectiveness of regulations and asses s overall national impacts of efficiency programs. The paper presents the work done in collaboration with the Ministry of Energy (MoE) in Chile and the Collaborative Labeling Appliance Standards Programs (CLASP) on designing a Minimum Energy Performance Standards (MEPS) and ext ending the current labeling program for refrigerators.

25 ENERGY STORAGE↗

Evaluation of Variable Refrigerant Flow Systems Performance and the Enhanced Control Algorithm on Oak Ridge National Laboratory's Flexible Research Platform

A research project “Evaluation of Variable Refrigerant Flow (VRF) Systems Performance and the Enhanced Control Algorithm on Oak Ridge National Laboratory’s (ORNL’s) Flexible Research Platform” was performed to (1) install and validate the performance of Samsung VRF systems compared with the baseline rooftop unit (RTU) variable-air-volume (VAV) system and (2) evaluate the enhanced control algorithm for the VRF system on the two-story flexible research platform (FRP) in Oak Ridge, Tennessee. Based on the VRF system designed by Samsung and ORNL, the system was installed from February 18 through April 15, 2014. The final commissioning and system optimization were completed on June 2, 2014, and the initial test for system operation was started the following day, June 3, 2014. In addition, the enhanced control algorithm was implemented and updated on June 18. After a series of additional commissioning actions, the energy performance data from the RTU and the VRF system were monitored from July 7, 2014, through February 28, 2015. Data monitoring and analysis were performed for the cooling season and heating season separately, and the calibrated simulation model was developed and used to estimate the energy performance of the RTU and VRF systems. This final report includes discussion of the design and installation of the VRF system, the data monitoring and analysis plan, the cooling season and heating season data analysis, and the building energy modeling study

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Variable Refrigerant Flow Systems Performance on Oak Ridge National Laboratory s Flexible Research Platform: Part 1 Cooling Season Analysis

This report provides second-year cooling season test results for the multi-year project titled “Evaluation of Variable Refrigeration Flow (VRF) System on Oak Ridge National Laboratory (ORNL)’s Flexible Research Platform (FRP).” The purpose of the second-year project was to (1) evaluate the full- and partload performance of VRF systems compared with an existing baseline heating, ventilation, and airconditioning (HVAC) system, which is a conventional rooftop unit (RTU) variable-air-volume (VAV) system with electric resistance heating and (2) use hourly building energy simulation to evaluate the energy savings potential of using VRF systems in major US cities. The second-year project performance period was from July 2015 through June 2016.

47 OTHER INSTRUMENTATION↗

Methodology for Estimating Safe Charge Limits of Flammable Refrigerants in HVAC&R Applications - Part 2

This report provides a detailed description of the development of a reduced order model (ROM) that could be used for estimation of safe charge limits based on a computational fluid dynamics (CFD) parametric study. The ROM was developed to simulate leak events from a single side-wall duct penetration into a room and provide estimates of refrigerant concentration together with flammable volume fraction (FVF), accumulated fuel volume (AFV) and other outputs vs. time. The ROM is based on a range of seven parameters listed in Table ES1 and assumes that the AC unit air circulation blower is off. A total of 586 CFD “training” cases were run and used as the basis for development and training or calibration of the ROM. The regression analysis used to develop the ROM was performed in Tasmanian ( T oolkit for A daptive S tochastic M odeling A nd N on- I ntrusive A pproximatio N ). This is a tool developed at ORNL for high-dimensional integration, interpolation and parameter calibration. Comparison of the ROM vs. several CFD test cases (at points not used in the training set) showed maximum absolute and root mean square errors (RMSE) for FVF of 1.32% and 0.5%, respectively. Initial CFD runs were conducted to gauge the sensitivity of the results to each parameter. Based on the findings, the numbers of design of experiment (DoE) levels for each parameter was determined. Then, for each parameter, Tasmanian calculated the value of each level and defined a DoE of 586 unique CFD simulation cases.

42 ENGINEERING↗

NGL Extraction from EOR Gas - Refrigeration

Natural gas liquids extraction from gas recovered from enhanced oil recovery (EOR) operations using refrigeration and distillation. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=B78073BF-2531-4847-A0B1-BEBFD0A4E8BC

03 NATURAL GAS↗

Evaluation of High Rotor Pole Switched Reluctance Motors to Control Condenser Fans in a Commercial Refrigeration System

A high rotor pole switched reluctance motor (HRSRM) designed by Software Motor Corporation was evaluated for use as a condenser fan motor due to its reported high motor efficiency over a broad range of speeds and added advanced control potential. The project was split into two phases; the first of which was to determine the direct energy savings due to the increased motor efficiency, the second was to leverage the additional benefits of the energy efficiency measure (EEM) to create additional energy savings. This report only discusses results from the first phase of the project. Nine 1.5hp HRSRMs were installed parallel to the same number of legacy induction motors of a supermarket commercial refrigeration system located in Lakeside, Colorado. At this site, the 1.5 hp legacy motors had historically adjusted condenser fan speed from 200-870 rpm based on outdoor air temperature and compressor discharge pressure. This type of control is known as variable head pressure control (VHPC). These nine new motors were given a signal from the legacy variable frequency drive (VFD) to match the motor speed of the legacy motors. Determination of the energy savings of the EEM was performed over a two-month period, at which time a correlation between legacy and EEM power consumption was developed based on motor speed. Annual data that had been collected from 2016-2017 (before the two-month test period) was then leveraged to predict the annual energy savings of the EEM for a complete retrofit using both VHPC and constant fan speed control. Table 1 displays the quantitative results. The EEM saved 27% of total energy consumption of the condenser fan motors for constant fan speed control, while the energy savings increased to 32% when using VHPC. This was due to the improved motor efficiency of the HRSR motor at low speeds. While the constant speed fan control kept the motors running at 870 rpm, VHPC adjusted fan speed between 200-870rpm based on the outdoor air temperature and the compressor discharge pressure. These savings are assuming a direct replacement with no additional controls. Retrofitting a constant speed fan control system with HRSRMs and switching to VHPC would provide significant energy savings looking at the condenser alone. Additional considerations of the EEM were noted during the project as well. The HRSRM system made it possible to identify and remotely shutdown an individual motor when a piece of foam locked the fan and thereby the motor. With the traditional system, a locked rotor could have caused motor damage unless a breaker or fuse was activated. Furthermore, due to vibration complaints from the installation technicians, the ramp-up time of the HRSRM had to be increased to a minute. After implementing this change no complaints for excessive vibration were recorded.

15 GEOTHERMAL ENERGY↗

Development and Evaluation of Distributed Energy Resource Device Models: Electric Vehicles, Electric Water Heaters, and Commercial Refrigeration Systems

In order to validate distributed energy resource (DER) models operated with grid services in the GMLC 1.4.2 team’s February (GMLC 2019a) and July (GMLC 2019b) reports, a test and measurement program using actual DER devices was conducted by national laboratories for three devices: (1) electric vehicles (EVs), (2) water heaters, and (3) commercial refrigeration. Test procedures were developed and carried out to identify the mathematical models and their parameters that describe the operational function, characterize the physics, and obey transient response of the devices. This report focuses on the experimental results obtained to develop and verify simulations of three specific EV models. This section summarizes elements of the mathematical model and shows the necessity data collected from the EVs while charging and discharging (driving). In the course of the study, we found it necessary to make some modifications to the model to deal with observed transient behavior. Section 1.2 details the model assumptions and equations, Section 1.3 provides details of the EVs tested, Section 1.4 outlines the test procedures developed for the projects, and Section 1.5 presents the experimental results obtained for the three different EVs tested and how these results compare to the models running the same test profiles.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Building Technologies Office 03.02.02.38 Milestone Report—Compressor Technology Development for Refrigerants with <150 Global Warming Potential

The major purpose of this project is to enable the development of compressors specifically designed for compatibility with low–global warming potential (GWP) refrigerants (with GWP values below 150). These compressors are intended for applications in residential and light commercial air-conditioning and heat pump systems. This report contains an exhaustive review of the existing literature with the intention of discerning the most efficacious methodologies currently in use for compressor modeling. This fundamental stage was designed to foster a comprehensive understanding of the intricate dynamics and mechanics of compressors. As a result, a model (PDSim) was selected to simulate scroll, rotary and linear compressor technologies.

42 ENGINEERING↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single heating, ventilation, and air-conditioning (HVAC) end-use savings shape measure - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation. This measure replaces existing multi-zone variable air volume (VAV) systems or single-zone rooftop units (RTU) with a VRF HR system coupled with a DOAS that includes an energy/heat recovery ventilator (E/HRV). The measure covers 53% of exisiting building stock's floor area and is not applicable to HVAC system types using district heating or cooling or buildings/spaces that include high-ventilation spaces such as kitchens where the amount of exhaust air is large. A DOAS with E/HRV is used to provide required outdoor ventilation air to spaces since ventilation air is generally not supplied by a VRF HR system. An exhaust air energy recovery ventilator (ERV ) with sensible and latent heat exchange is added to humid climate zones while a heat recovery ventilator (HRV ) with sensible only exchange is added to drier climate zones. The ERV is modeled as a fixed membrane plate counterflow heat exchanger, while the HRV is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and minimum exhaust temperature control for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End Station Refrigerator 2 Cryoplant at JLAB

The future operation of the 4 kW 15 Kelvin MOLLER experiment at Jefferson lab necessitates an increase of cryogenic capacity at the End Station Refrigerator. The current plant is the former 1.5 kW (4.5 K) ESCAR plant that has been operating at Jefferson Lab since 1995. The existing 1.5 kW plant is not able to support the load for MOLLER and will be replaced with a refurbished plant comprised of the cold box and compressors of the 4 kW ASST-A plant from the Superconducting Super Collider in Texas. This paper outlines the assembly, repair and modifications made to the cold box, along with the design of the plant as a whole and its integration into the existing distribution system.

Perry, Christopher↗

Residential HVAC Fault Data Collection Plan – Refrigerant Undercharge and Overcharge Faults

Heating, ventilation, and air-conditioning (HVAC) systems can develop faults due to poor installation practices or gradual wear and tear, leading to decreased HVAC system’s efficiency, compromised thermal comfort, and shortened equipment lifespan (EERE, 2018). Automated fault detection and diagnosis (AFDD) technologies offer a solution by identifying energy-wasting HVAC faults, such as inadequate indoor airflow and incorrect refrigerant charge, and guiding technicians to enhance system efficiency. In the realm of residential HVAC, AFDD can be implemented through various fault detection and diagnosis capabilities, sensor configurations, and target applications. These technologies typically fall into three categories: smart diagnostic tools, original equipment manufacturer (OEM)-embedded tools, and add-on tools. Smart diagnostic tools employ temporarily installed sensors to directly measure HVAC system characteristics, while OEM-embedded tools utilize factory-installed sensors to identify faults or assess system performance. However, both these types of AFDD technologies are often only accessible for high-end HVAC equipment or require additional sensor installation by qualified technicians, resulting in high investment costs and limited applicability for low-income residential buildings. On the other hand, add-on tools rely solely on data from smart thermostats and meters to detect faults by continuously analyzing equipment runtime or energy usage. As smart thermostat and meter costs decrease and their prevalence increases, these tools can be readily deployed in low-income residential buildings. However, they possess limited capabilities as they rely solely on basic trend analysis. Enhancing such tools with advanced machine learning algorithms can significantly improve their effectiveness.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LBNF/DUNE Nitrogen Refrigeration System Update

The Deep Underground Neutrino Experiment (DUNE) is supported by the infrastructure of the Long Baseline Neutrino Facility (LBNF). The central feature of DUNE is the liquid argon filled cryostats, which house the neutrino detector components. In order to maintain the argon in a liquid state, heat must be continuously removed. Argon condensers will remove this heat, and liquefy the argon, through the evaporation of liquid nitrogen. The supply of liquid nitrogen relies heavily on a near-industrial scale nitrogen refrigeration/liquefaction system. The nitrogen system will be a closed loop, in which the liquid nitrogen is supplied to users and, after being vaporized, is recycled to the nitrogen liquefaction units to be liquefied again. The system will also include nitrogen generation, to increase inventory in the closed loop, as well as to make up for losses. All of this will be installed nearly one mile underground (1.5km) on the 4850 level of the Sanford Underground Research Facility (SURF). The final DUNE vision requires 400kW of liquid nitrogen cooling capacity. Based on the operation modes and phased installation of the experiment, modularity of this cooling capacity is required. Nitrogen liquefaction will occur in four units which will afford a wide operational range of production (nominally 100kW each). Due to the experiment’s location deep underground in an inactive gold mine, there are unique and challenging constraints. These include limited access, footprint, and utilities. This poster describes the engineering effort, and provides an overview of the refrigeration system. The design includes a unique compressor arrangement which is covered in detail. Pictures and models are included where possible to help visualize the system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Eliminating the Need for Refrigerants Using New Liquid and Salt-Based Cooling and Heat-Pumping Technology (CRADA Final Report)

Calion Technologies, Inc. project team investigated various embodiments of the ionocaloric cycle. Ionocaloric technology provides a new platform for all heating and cooling that is zero-GWP, non-toxic, non-hazardous, and non-flammable. It is well-poised to replace vapor compression technology which uses high-GWP refrigerants which are on track to account for 25% of our global warming budget. Developing the ionocaloric technology as a drop-in replacement for vapor compression was the primary research thrust under this CRADA.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

2 Kelvin helium distribution system for the Electron Ion Collider’s 10 o’clock satellite refrigerator

The Electron-Ion Collider (EIC) at Brookhaven National Laboratory (BNL) will involve superfluid helium cooling of superconducting magnets and Superconducting Radio Frequency (SRF) cavities at several sites around the existing Relativistic Heavy Ion Collider (RHIC) accelerator tunnel. While the majority of the cooling power for these loads is provided by BNL’s central cryogenic plant, Jefferson Lab is designing satellite equipment which augments the central plant and enables 2 Kelvin operation. The 2 K cryogenic distribution system for the collider’s 10 o’clock location (Interaction Region 10 or IR10) includes all necessary interfaces to the IR10 Satellite Refrigerator, to the overall EIC cryogenic distribution system, and to 12 SRF cryomodules for the electron and hadron storage rings. In addition to providing the required cooling capacities in all operating modes, the IR10 2 K cryogenic distribution system also stabilizes the supply temperature and enables safe connection and disconnection of individual IR10 cryomodules. Moreover, the layout of the IR10 2 K cryogenic distribution system copes with challenging spatial constraints and adapts to the process configuration and routing of existing RHIC cryogenic distribution components which will be re-used for EIC. This paper gives a full overview of the IR10 satellite cryogenic distribution system design, and highlights some of the challenges encountered.

Laverdure, Nathaniel [Thomas Jefferson National Ac↗