Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIOLOGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Global Radiological Source Sorting, Tracking, and Monitoring (Gradsstram) Using Emergin RFID and Web 2.0 Technologies to Provide Total Asset and Information Visualization, Paper at 2009 INMM

Background Thousands of shipments of radioisotopes developed in the United States (U.S.) are transported domestically and internationally for medical and industrial applications, including to partner laboratories in European Union (EU) countries. Over the past five years, the Environmental Protection Agency (EPA), the Department of Energy (DOE), and Oak Ridge National Laboratory (ORNL)1 have worked with state first responder personnel, key private sector supply chain stakeholders, the Department of Homeland Security (DHS), the Department of Transportation (DOT), the Department of Defense (DoD) and the Nuclear Regulatory Commission (NRC) on Radio Frequency Identification (RFID) tracking and monitoring of medical, research and industrial radioisotopes in commerce. ORNL was the pioneer of the international radioisotope shipping and production business. Most radioisotopes made and used today were either made or discovered at ORNL. While most of the radioisotopes used in the commercial sector are now produced and sold by the private market, ORNL still leads the world in the production of exotic, high-value and/or sensitive industrial, medical and research isotopes. The ORNL-EPA-DOE Radiological Source Tracking and Monitoring (RadSTraM) project tested, evaluated, and integrated RFID technologies in laboratory settings and at multiple private-sector shipping and distribution facilities (Perkin Elmer and DHL) to track and monitor common radioisotopes used in everyday commerce. The RFID tracking capability was also tested in association with other deployed technologies including radiation detection, chemical/explosives detection, advanced imaging, lasers, and infrared scanning. At the 2007 EU-U.S. Summit, the leaders of the US Department of Commerce (DOC) and EU European Commission (EC) committed to pursue jointly directed Lighthouse Priority Projects. These projects are intended to foster cooperation and reduce regulatory burdens with respect to transatlantic commerce. The Transatlantic Economic Council (TEC) Lighthouse Project on Radio Frequency Identification (RFID) has been directed to develop a joint framework for cooperation on identification and development of best practices for Radio Frequency Identification (RFID) technologies The RFID Lighthouse Priority Project commits both sides to endeavor to align U.S. and EU regulatory and policy approaches on RFID technologies, including pilot projects in the public sector.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Energy Measurements in Radiological Emergency Response Applications

We present significant results in recent advances in the determination of neutron energy. Neutron energy measurements are a small but very significant part of radiological emergency response applications. Mission critical information can be obtained by analyzing the neutron energy given off from radioactive materials. In the case of searching for special nuclear materials, neutron energy information from an unknown source can be of paramount importance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Justification Of The Use Of Boreholes For Disposal Of Sealed Radiological Sources

Soon there will be only 14 states in two compacts that are able to dispose of Low Level Waste (LLW): the Northwest and Rocky Mountain compact with disposal options in Richland, Washington, and the Atlantic compact with disposal options in Barnwell, South Carolina. How do states not in one of the two compacts dispose of their LLW? The Off-Site Source Recovery Project can take possession and dispose of some of the unwanted transuranic sources at the Waste Isolation Pilot Plant (WIPP). However, there will be no path forward for states outside of the two compacts for disposal of their non-transuranic LLW. A solution that has been much discussed, debated and researched, but has not been put into wide scale practice, is the borehole disposal concept. It is the author's position that companies that drill and explore for oil have been disposing of sources in borehole-like structures for years. It should be noted that these companies are not purposely disposing of these sources, but the sources are irretrievable and must be abandoned. Additionally, there are Nuclear Regulatory Commission (NRC) regulations that must be followed to seal the well that contains the lost and abandoned source. According to the NRC Event Notification Reports database, there were a minimum of 29 reports of lost and abandoned sources in oil wells between December 1999 and October 2006. The sources were lost at depths between 2,018-18,887 feet, or 600-5,750 meters. The companies that are performing explorations with the aid of sealed radiological sources must follow regulation 10 CFR Part 39. Subsection 15 outlines the procedures that must be followed if sources are determined to be irretrievable and abandoned in place. If the NRC allows and has regulations in place for oil companies, why can't states and/or companies be allowed to dispose of LLW in a similar fashion?

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced urothelial cancer: a radiology update

The recent genomic characterization of urothelial carcinoma by the Cancer Genome Atlas Project, made possible by the introduction of high throughput, reduced cost, and sequence analysis, has shed new insights on the biology of advanced disease. In addition, studies on imaging of advanced urothelial carcinoma have widened the knowledge on disease presentation and on pattern of metastatic spread and their correlation with the underlying biology of urothelial carcinoma. The wide range of treatments for advanced urothelial cancer, including combined chemotherapy regimens and immune checkpoint inhibitors, each result in treatment class-specific patterns of response and adverse events. Results of studies point to the need for a reliable biomarker, perhaps with imaging, that predicts prognosis and treatment response to systemic treatment, and can be used to select the most effective treatment while minimizing toxicity. This review of advanced urothelial cancer introduces the latest advances in genetic profiling, the current role of imaging, the radiographic appearance of treatment response and their toxicities, and details potential future areas of imaging research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diagnosis, management, and follow-up of upper tract urothelial carcinoma: an interdisciplinary collaboration between urology and radiology

Upper tract urothelial carcinoma (UTUC) is a common and lethal malignancy. Patients diagnosed with this illness often face invasive workups, morbid therapies, and prolonged post-operative surveillance. UTUC represents approximately 5–10% of urothelial malignancies in the United States and affect 4600–7800 new patients annually. Various environmental exposures as well as smoking have been implicated in the development of UTUC. The diagnosis and workup of UTUC relies on heavily on imaging studies, a close working relationship between Urologists and Radiologists, and invasive procedures such as ureteroscopy. Treatments range from renal-sparing endoscopic surgery to radical extirpative surgery depending on the specific clinical situation. Follow-up is crucial as UTUC has a high recurrence rate. Here we review the epidemiology, diagnosis, management strategies, and follow-up of UTUC from an interdisciplinary perspective.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiological Findings and Endovascular Management of Three Cases with Segmental Arterial Mediolysis

Segmental arterial mediolysis (SAM) is an uncommon self-limited disorder that can cause abdominal catastrophes through massive bleeding or bowel infarction. The former arise from arterial aneurysms, and the latter from arterial stenosis or occlusions. Although this is an acute self-limiting disease, the catastrophic consequence, originating from intra-abdominal hemorrhage (arterial dilatation, aneurysms, dissecting hematomas) or bowel infarction (arterial stenosis, arterial occlusions), is not rare. The identification of these lesions is very important in the differential diagnosis of suspected patients with complaints of abdominal pain with hemorrhage. We report computerized tomography angiography and digital subtraction angiography findings of three cases with abdominal SAM, who were treated with endovascular management due to abdominal bleeding. Angiography showed arterial dilatations, aneurysms, and occlusions of visceral arteries in all three cases, The string-of-beads appearance was present in only one case. Bleeding stopped immediately after embolization of three cases and follow-up revealed no evidence of recurrences at 23, 18, and 15 months, respectively, Arterial coil embolization is an effective treatment modality for bleeding complications of SAM. Close follow-up is recommended, primarily to ascertain the fate of the nontreated arterial lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

How to Interpret Thyroid Biopsy Results: A Three-Year Retrospective Interventional Radiology Experience

Results of thyroid biopsy determine whether thyroid nodule resection is appropriate and the extent of thyroid surgery. At our institution we use 20/22-gauge core biopsy (CBx) in conjunction with fine-needle aspiration (FNA) to decrease the number of passes and improve adequacy. Occasionally, both ultrasound (US)-guided FNA and CBx yield unsatisfactory specimens. To justify clinical recommendations for these unsatisfactory thyroid biopsies, we compare rates of malignancy at surgical resection for unsatisfactory biopsy results against definitive biopsy results. We retrospectively reviewed a database of 1979 patients who had a total of 2677 FNA and 663 CBx performed by experienced interventional radiologists under US guidance from 2003 to 2006 at a tertiary-care academic center. In 451 patients who had surgery following biopsy, Fisher's exact test was used to compare surgical malignancy rates between unsatisfactory and malignant biopsy cohorts as well as between unsatisfactory and benign biopsy cohorts. We defined statistical significance at P = 0.05. We reported an overall unsatisfactory thyroid biopsy rate of 3.7% (100/2677). A statistically significant higher rate of surgically proven malignancies was found in malignant biopsy patients compared to unsatisfactory biopsy patients (P = 0.0001). The incidence of surgically proven malignancy in unsatisfactory biopsy patients was not significantly different from that in benign biopsy patients (P = 0.8625). In conclusion, an extremely low incidence of malignancy was associated with both benign and unsatisfactory thyroid biopsy results. The difference in incidence between these two groups was not statistically significant. Therefore, patients with unsatisfactory biopsy specimens can be reassured and counseled accordingly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiological Management of Hemoptysis: A Comprehensive Review of Diagnostic Imaging and Bronchial Arterial Embolization

Hemoptysis can be a life-threatening respiratory emergency and indicates potentially serious underlying intrathoracic disease. Large-volume hemoptysis carries significant mortality and warrants urgent investigation and intervention. Initial assessment by chest radiography, bronchoscopy, and computed tomography (CT) is useful in localizing the bleeding site and identifying the underlying cause. Multidetector CT angiography is a relatively new imaging technique that allows delineation of abnormal bronchial and nonbronchial arteries using reformatted images in multiple projections, which can be used to guide therapeutic arterial embolization procedures. Bronchial artery embolization (BAE) is now considered to be the most effective procedure for the management of massive and recurrent hemoptysis, either as a first-line therapy or as an adjunct to elective surgery. It is a safe technique in the hands of an experienced operator with knowledge of bronchial artery anatomy and the potential pitfalls of the procedure. Recurrent bleeding is not uncommon, especially if there is progression of the underlying disease process. Prompt repeat embolization is advised in patients with recurrent hemoptysis in order to identify nonbronchial systemic and pulmonary arterial sources of bleeding. This article reviews the pathophysiology and causes of hemoptysis, diagnostic imaging and therapeutic options, and technique and outcomes of BAE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Role of Interventional Radiology in the Management of Deep Venous Thrombosis: Advanced Therapy

Deep vein thrombosis (DVT) is often managed with a health care pathway that funnels patients to anticoagulation therapy alone. This 'usual treatment' is designed to stop propagation and embolisation of venous thrombus but not remove it. Surgical thrombectomy was once the only option in severe cases in which limbs were threatened, but thrombus removal is no longer restricted to emergency cases. Interventional radiologists are now using advanced endovascular techniques to achieve thrombus removal in a minimally invasive manner in a very short treatment time, thereby quickly restoring patency, relieving acute symptoms, and potentially limiting the subsequent development of postthrombotic syndrome when followed with anticoagulation and compression regimens. This article provides an overview of the interventions available for treating DVT. One of the newer 'single-session' techniques is isolated pharmacomechanical thrombolysis, which is described here in detail with supporting cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Angiography in the Isolated Perfused Kidney: Radiological Evaluation of Vascular Protection in Tissue Ablation by Nonthermal Irreversible Electroporation

Purpose: The nonthermal irreversible electroporation (NTIRE) is a novel nonthermal tissue ablation technique by local application of high-voltage current within microseconds leading to a delayed apoptosis. The purpose of this experimental study was the first angiographic evaluation of the acute damage of renal vascular structure in NTIRE. Methods: Results of conventional dynamic digital substraction angiography (DSA) and visualization of the terminal vascular bed of renal parenchyma by high-resolution X-ray in mammography technique were evaluated before, during, and after NTIRE of three isolated perfused porcine ex vivo kidneys. Results: In the dedicated investigation, no acute vascular destruction of the renal parenchyma and no dysfunction of the kidney perfusion model were observed during or after NTIRE. Conspicuous were concentric wave-like fluctuations of the DSA contrast agent simultaneous to the NTIRE pulses resulting from NTIRE pulse shock wave. Conclusion: The NTIRE offers an ablation method with no acute collateral vascular damage in angiographic evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Role of Interventional Radiology in the Management of Abdominal Visceral Artery Aneurysms

Abdominal visceral artery aneurysms (VAA) include true and false aneurysms. The majority are asymptomatic and are discovered on cross-sectional imaging performed for unrelated clinical indications. With the maturation of techniques and devices used for embolization procedures and the treatment of aneurysms in other locations, most VAAs are now suitable for treatment by minimally invasive transcatheter techniques. The choice of technique used greatly depends on the local anatomy of the VAA and the experience of the interventional radiologist in complex vascular interventional techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reducing Blood-borne Exposure in Interventional Radiology: What the IR Should Know

Interventional radiologists are at risk of exposure to blood-borne pathogens in their day-to-day practice. Percutaneous exposure from unsafe sharps handling, mucocutaneous exposure from body fluid splashes, and glove perforation from excessive wear can expose the radiologist to potentially infectious material. The increasing prevalence of blood-borne pathogens, including hepatitis B and C, and human immunodeficiency virus, puts nurses, residents, fellows, and interventional radiologists at risk for occupational exposure. This review outlines suggestions to establish a culture of safety in the interventional suite.

60 APPLIED LIFE SCIENCES↗

Clinical Outcomes of Stereotactic Body Radiotherapy for Small Lung Lesions Clinically Diagnosed as Primary Lung Cancer on Radiologic Examination

Purpose: Image-guided biopsy occasionally fails to diagnose small lung lesions, which are highly suggestive of primary lung cancer. The aim of the present study was to evaluate the outcome of stereotactic body radiotherapy (SBRT) for small lung lesions that were clinically diagnosed as primary lung cancer without pathologic confirmation. Methods and Materials: A total of 115 patients were treated with SBRT in 12 institutions. Tumor size ranged from 5 to 45 mm in diameter, with a median of 20 mm. Results: The 3-year and 5-year overall survival rates for patients with a tumor size <=20 mm in diameter (n = 58) were both 89.8%, compared with 60.7% and 53.1% for patients with tumors >20 mm (n = 57) (p <0.0005), respectively. Local progression occurred in 2 patients (3.4%) with a tumor size <=20 mm and in 3 patients (5.3%) with tumors >20 mm. Among the patients with a tumor size <=20 mm, Grade 2 pulmonary complications were observed in 2 (3.4%), but no Grade 3 to 5 toxicity was observed. In patients with a tumor size >20 mm, Grades 2, 3, and 5 toxicity were observed in 5 patients (8.8%), 3 patients (5.3%), and 1 patient (1.8%), respectively. Conclusion: In patients with a tumor <=20 mm in diameter, SBRT was reasonably safe in this retrospective study. The clinical implications of the high local control rate depend on the accuracy of clinical/radiologic diagnosis for small lung lesions and are to be carefully evaluated in a prospective study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulation of image detectors in radiology for determination of scatter-to-primary ratios using Monte Carlo radiation transport code MCNP/MCNPX

Purpose: The purpose of this study was to compare and validate three methods to simulate radiographic image detectors with the Monte Carlo software MCNP/MCNPX in a time efficient way. Methods: The first detector model was the standard semideterministic radiography tally, which has been used in previous image simulation studies. Next to the radiography tally two alternative stochastic detector models were developed: A perfect energy integrating detector and a detector based on the energy absorbed in the detector material. Validation of three image detector models was performed by comparing calculated scatter-to-primary ratios (SPRs) with the published and experimentally acquired SPR values. Results: For mammographic applications, SPRs computed with the radiography tally were up to 44% larger than the published results, while the SPRs computed with the perfect energy integrating detectors and the blur-free absorbed energy detector model were, on the average, 0.3% (ranging from -3% to 3%) and 0.4% (ranging from -5% to 5%) lower, respectively. For general radiography applications, the radiography tally overestimated the measured SPR by as much as 46%. The SPRs calculated with the perfect energy integrating detectors were, on the average, 4.7% (ranging from -5.3% to -4%) lower than the measured SPRs, whereas for the blur-free absorbed energy detector model, the calculated SPRs were, on the average, 1.3% (ranging from -0.1% to 2.4%) larger than the measured SPRs. Conclusions: For mammographic applications, both the perfect energy integrating detector model and the blur-free energy absorbing detector model can be used to simulate image detectors, whereas for conventional x-ray imaging using higher energies, the blur-free energy absorbing detector model is the most appropriate image detector model. The radiography tally overestimates the scattered part and should therefore not be used to simulate radiographic image detectors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗