Shielding techniques.
Charged-particle shielding technology for spacecraft noting particle interaction with matter, penetration calculation and amassed data
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Charged-particle shielding technology for spacecraft noting particle interaction with matter, penetration calculation and amassed data
Space radiation poses multiple health risks to astronauts including cancer, cardiovascular disease, and damage to the central nervous system. Radiation from galactic cosmic rays (GCR) is the main source of these risks for missions beyond low Earth orbit to the moon and beyond. A galactic cosmic ray simulator (GCRsim) was developed at the NASA Space Radiation Laboratory to better understand and mitigate these risks by simulating the complex mixed field of the GCR environment at a ground-based facility. The GCRsim delivers a radiation field to cell and animal models in a laboratory setting that is comparable to the shielded radiation environment within internal organs of astronauts in deep space missions. Previous verification studies using Monte Carlo simulations with mouse (Digimouse) and rat (Digirat) digital phantoms showed that the GCRsim yields acceptable dose homogeneity within the internal organs of these animals. Spectral characteristics of the intended space radiation environment are also accurately reproduced at radiosensitive sites in both phantoms. In this work, similar Monte Carlo simulations were performed in a minipig model (Digipig) to show the applicability and limitations of the current GCRsim for larger animal model systems. The results showed dose homogeneity in internal organs of the three animal models with GCRsim irradiation. While slightly lower average doses were seen in the minipig compared to the external beam dose, the individual voxel doses in slices of the phantoms were found to be within 6%–8% of the average voxel dose, establishing that the GCRsim can still provide a relatively homogeneous irradiation within larger animals. Furthermore, simulated dose and fluence spectral results across the relevant linear energy transfer (LET) range agreed well with the reference field in the most relevant regions of the spectra, further verifying that the GCRsim beam represents the reference field in larger animals.
Differential cross sections for forward-angle photoproduction of p0, ¿, and ¿ 1 pseudoscalar mesons were measured using data from the RadPhi experiment conducted in Hall B at Jef ferson Lab. RadPhi utilized a tagged bremsstrahlung photon beam incident on a stationary 9Be target, with a detector system configured to trigger on a recoil proton in coincidence with multiple neutral showers in the calorimeter. Events were reconstructed and subjected to kinematic constraints, with background suppressed via sideband subtraction guided by Monte Carlo modeling of background contributions. Cross sections were extracted over the photon energy range 4.4– 5.4 GeV and binned in invariant momentum transfer t, providing measurements from one of the first high-statistics experiments of forward ¿ and ¿1 pro duction from a nuclear target at these energies. Acceptance corrections were applied using a detailed GEANT-based simulation of the detector geometry and response. The resulting cross sections are consistent with 2020 CLAS results, when scaled by the number of protons in beryllium, and show broad agreement with other data and theoretical models. In parallel, a high-resolution photon tagger detector, the Tagger Microscope (TAGM), was designed, constructed, and commissioned for the GlueX experiment in Hall D at Jefferson Lab. The TAGM was developed to provide high-rate tagging capability in the coherent bremsstrahlung peak by detecting post-bremsstrahlung electrons across a one GeV range along the focal plane of the tagging spectrometer. The detector consists of a 5ˆ102 array of 2ˆ2 mm2 square BCF-20 plastic scintillating fibers thermally fused to BCF-98 light guide fibers optically coupled to silicon photomultipliers. These fibers are mounted in a precision machined framework enabling fine positional adjustments to maintain precise alignment with post-bremsstrahlung electron trajectories, while ensuring mechanical rigidity, thermal stability, optical isolation, minimal inactive area, and radiation shielding for electronics. The construction effort involved extensive testing of fiber quality, light transmission, thermal fusing, radiation hardness, and defect analysis using SEM and EDX techniques. Following its installation and commissioning, the TAGM became a critical component of the GlueX beamline, enabling high-rate tagging essential for studies of hybrid mesons and gluonic ex citations.
Tests at Mach 6 and 8 have been conducted on a model of a wind tunnel sound radiation shield which consists of interchangeable circular and wedge-shaped longitudinal rods with gaps between the rods for boundary layer removal. In view of the large effective sweep angle of the circular rods with respect to the local flow, the boundary layer behavior was surprisingly well represented by swept cylinder theory. Laminar flow was maintained up to a maximum local unit Reynolds number of 8 million per foot which would presumably be independent of model length for a given rod diameter by analogy with results on swept cylinders. Reduction in wind-tunnel sound levels within the shielded region of the circular rod model were about 90% of the maximum possible reduction for an ideal shield.
URS-CH2M Oak Ridge LLC (UCOR) is responsible for cleanup of the U.S. Department of Energy's (DOE) East Tennessee Technology Park (ETTP) in Oak Ridge, Tennessee. Formerly known as the K-25 site, the facility enriched uranium for major defense and energy programs for more than 40 years. DOE is seeking the safest, most environmentally protective and fiscally responsible treatment for its large inventory of radioactive-contaminated metals known as 'shields'. The 66 sodium and lithium shields were constructed for use in experiments at the Tower Shielding Facility (TSF), Oak Ridge National Laboratory (ORNL). The TSF operated from 1954 to 1992 and was designed and built for radiation-shielding studies. The shield containers are constructed of aluminum or stainless steel of varying sizes and shapes that were then filled with either sodium metal or lithium hydride material. The historical records indicate the sodium shields were constructed at the Molten Salt Reactor for use in experiments in the 1971 time frame, while the lithium shields were constructed at the Y-12 site and were used in experiments as early as 1961. A subset of the sodium and lithium shields contain depleted uranium. The sodium and lithium shields were initially used at the TSF to perform in-depth measurements of the neutron transport through the shield materials. Based on process knowledge, the shields are managed as radiologically contaminated containers. Efforts have been made over the last fifteen years to find recycle markets for both the sodium and lithium hydride shields. This includes an onsite operation that was initiated at the East Tennessee Technology Park (ETTP) in 2004. After an operational exothermic reaction incident occurred soon after startup, the onsite ETTP recycling action was discontinued and a search for offsite recycling facilities was initiated. In 2016, the Y-12 National Security Complex was contacted regarding recycle/repurpose of the lithium shields; however, the lithium was determined to not be acceptable for their current repurpose process. To date, no offsite recycling outlets have been identified. Recent progress on the waste disposal actions, a shipment of 22 small sodium shields have been shipped and treated offsite. Therefore, the current shield inventory consists of 29 sodium shields located at ETTP and 15 sodium and lithium hydride shields staged at ORNL. The time period needed to reasonably identify safe disposition or recycling outlets for the shields was expected to exceed the one-year Land Disposal Restrictions storage time limit; therefore, approval was received to add the shields to the Site Treatment Plan (STP) in March, 2017. Until a disposition path is found, the shields will continue to be stored in a safe configuration that is protective of human health and the environment. This engineering evaluation identifies and screens the alternatives for dispositioning the shields at the Oak Ridge(ORR). Four alternatives were evaluated including; (1) macro-encapsulation, (2) deactivation, (3) recycle and (4) leave-in-place. An initial screening was performed, and the alternative passing the initial screening are then evaluated in more detail. The evaluation criteria used included environmental risk, technical feasibility, administrative feasibility, worker safety, nuclear safety, transportation safety, and cost. (author)
The world record fusion power production is 16.1 MW (5.7x10{sup 18} n/s). This was achieved at JET in 1995. The neutron budget during that experimental campaign was 2.5x10{sup 20} neutrons. In the first few seconds of an ITER full power pulse, the neutron production will exceed that the total from the entire history of previous controlled fusion experiments. It is envisaged that ITER should produce as much as 700 MW of fusion power. (This is the maximum envisaged power production from the plasma and does not include power multiplication in the blankets or shielding). This equates to the production of 2.48x10{sup 20} 14-MeV neutrons/s which will give an uncollided flux at the first wall of approximately 4x10{sup 13} n/cm{sup 2}/s and a total with the addition of the collided flux of some 10{sup 14} n/cm{sup 2}/s. For safety and licensing purposes it is the responsibility of ITER to satisfy the host state regulations and must limit doses to the public and staff. Furthermore, sufficient shielding must be provided to ensure that all components function adequately; and for decommissioning, ITER has a responsibility to reduce the volume and radio-toxicity of waste. The construction, operational and decommissioning phases of ITER are expected to last in excess of 30 years and the nuclear issues will be of critical importance throughout this time. The huge leap in neutron production in fusion experiments means that extensive nuclear analysis is required for ITER and it is the thesis of this paper that it is required at an unprecedented level. This is because of the combination of the large physical size of the installation, the variety of radiation sources, the attenuation required, the complexity of the geometry and the complexity of the sources and level of detail required. As a result of this unprecedented challenge the latest techniques for analysis, variance reduction and data display are being employed and in some cases being specifically developed. In this paper a few of the many representative examples of nuclear analysis will illustrate the thesis. The paper includes an examination of areas where further development could be made in the areas of radiation shield and nuclear analysis. Extensive nuclear analysis is required at ITER and the combination of the large physical size of the installation, the variety of radiation sources, the attenuation required, the complexity of the geometry, and the complexity of the sources mean that analysis is required at an unprecedented level of detail and quality. The latest techniques for analysis, variation reduction and data display are being employed and in some cases being specifically developed. Developments are required in areas of analysis, data visualization and experimental verification. (author)
Perturbation theory formulas were derived and applied to determine changes in neutron and gamma-ray doses due to changes in various radiation shield layers for fixed sources. For a given source and detector position, the perturbation method enables dose derivatives with respect to density, or equivalently thickness, for every layer to be determined from one forward and one inhomogeneous adjoint calculation. A direct determination without the perturbation approach would require two forward calculations to evaluate the dose derivative due to a change in a single layer. Hence, the perturbation method for obtaining dose derivatives requires fewer computations for design studies of multilayer shields. For an illustrative problem, a comparison was made of the fractional change in the dose per unit change in the thickness of each shield layer in a two-layer spherical configuration as calculated by perturbation theory and by successive direct calculations; excellent agreement was obtained between the two methods.
The long duration exposure facility (LDEF), launched into a 258 nautical mile orbit with an inclination of 28.5 degrees, remained in space for nearly 6 yr. The 21,500 lb NASA satellite was one of the largest payloads ever deployed by the Space Shuttle. LDEF completed 32,422 orbits and carried 57 major experiments representing more than 200 investigators from 33 private companies, 21 universities and nine countries. The experiments covered a wide range of disciplines including basic science, electronics, optics, materials, structures and power and propulsion. A number of the experiments were specifically designed to measure the radiation environment. These experiments are of specific interest, since the LDEF orbit is essentially the same as that of the Space Station Freedom. Consequently, the radiation measurements on LDEF will play a significant role in the design of radiation shielding of the space station. The contributions of the various authors presented here attempt to predict the major aspects of the radiation exposure received by the various LDEF experiments and therefore should be helpful to investigators who are in the process of analyzing experiments which may have been affected by exposure to ionizing radiation. The paper discusses the various types and sources of ionizing radiation including cosmic rays, trapped particles (both protons and electrons) and secondary particles (including neutrons, spallation products and high-LET recoils), as well as doses and LET spectra as a function of shielding. Projections of the induced radioactivity of LDEF are also discussed.
The overall radiation environment of LDEF was determined in part through the use of thermoluminescent detectors (TLDs). The results given are from four experiments (Biostack, Fiber Optics Data Link, Seeds in Space, and Linear Energy Transfer Spectrum Measurement) and represent a large fraction of existing absorbed dose data. The TLDs (located on leading and trailing edges) were under various shielding depths. The measured absorbed doses were found to reflect both directional dependence of incident trapped protons and shielding. Radiation dosages at both locations and under various shielding depths are given. The effect of the trapped proton anisotropy was such that the western side of LDEF received about 3 times the dose of the eastern side at shielding depths of approx. 1 gm/sq cm. These data are being used to evaluate the accuracy of models currently in use for predicting ionizing radiation environments for low Earth orbit missions.
Carbon foils were positioned at roughly 10 deg to the conventional perpendicular position so that the spectrometer would view the beam on emergence from the foil, with no radiation shielded by a bowed or wrinkled foil or by the foil holder. Extraneous peaks due to reflected radiation were detected in the spectrum obtained with the tilted foil. A large satellite appears longward of the spectral line and is attributed to Doppler-shifted radiation reflected from the foil surface. Special tests arranged to validate the origin of the satellites are described. The relative intensity of the reflected radiation compared with the direct radiation observed is at variance with the relative intensities reported for longer wavelengths. The reasons for this, possible effects of spectrometer geometry, and applications in the investigation or generation of polarization remain to be investigated
Photovoltaic and fission reactor orbital power systems are compared in terms of the end-to-end system power-to-mass ratios. Three PV systems are examined, i.e., a solid substrate with a cell array and a NiCd battery, a modified SEP array and an NiH2 battery, and a 62-micron Si cell array and a fuel cell. All arrays were modeled to be 13.5% efficient and to produce 25 kW dc. The SP-100 reactor consists of the heat source, radiation shield, heat pipes to transfer thermal energy from the reactor to thermoelectric elements, and a waste heat radiator. Consideration is given to system applications in orbits ranging from LEO to GEO, and to mission durations of 1, 5, and 10 yr. PV systems are concluded to be flight-proven, useful out of radiation belts, and best for low to moderate power levels. Limitations exist for operations where atmospheric drag may become a factor and due to the size of a large PV power supply. Space nuclear reactors will continue under development and uses at high power levels and in low altitude orbits are foreseen.
Because of reports indicating improvements in the radiation tolerance of some electronic parts, a survey was recently performed by SP-100 project personnel to determine the advisability of revising SP-100 SRPS (space reactor power systems) allowable neutron and gamma dose rates in order to reduce the size and mass of the radiation shield and thereby achieve system mass reductions. The survey results indicate that recent developments to increase the radiation tolerance of a limited set of electronics parts do not justify increasing the allowable SP-100 dose rates for electronic components. Specifically, the recent improvements on a limited set of parts do not justify increasing the current SP-100 allowable specifications of 5 x 10 exp 5 rads gamma dose and 1 x 10 exp 13 neutrons/sq cm fluence. However, if the improvements of 108 rads for gammas and 10 exp 15 neutrons/sq cm can be extended to a wide range of parts, significant mass savings would result.
The Juno Magnetic Field investigation (MAG) characterizes Jupiter's planetary magnetic field and magnetosphere, providing the first globally distributed and proximate measurements of the magnetic field of Jupiter. The magnetic field instrumentation consists of two independent magnetometer sensor suites, each consisting of a tri-axial Fluxgate Magnetometer (FGM) sensor and a pair of co-located imaging sensors mounted on an ultra-stable optical bench. The imaging system sensors are part of a subsystem that provides accurate attitude information (to approx. 20 arcsec on a spinning spacecraft) near the point of measurement of the magnetic field. The two sensor suites are accommodated at 10 and 12 m from the body of the spacecraft on a 4 m long magnetometer boom affixed to the outer end of one of 's three solar array assemblies. The magnetometer sensors are controlled by independent and functionally identical electronics boards within the magnetometer electronics package mounted inside Juno's massive radiation shielded vault. The imaging sensors are controlled by a fully hardware redundant electronics package also mounted within the radiation vault. Each magnetometer sensor measures the vector magnetic field with 100 ppm absolute vector accuracy over a wide dynamic range (to 16 Gauss = 1.6 x 10(exp. 6) nT per axis) with a resolution of approx. 0.05 nT in the most sensitive dynamic range (+/-1600 nT per axis). Both magnetometers sample the magnetic field simultaneously at an intrinsic sample rate of 64 vector samples per second. The magnetic field instrumentation may be reconfigured in flight to meet unanticipated needs and is fully hardware redundant. The attitude determination system compares images with an on-board star catalog to provide attitude solutions (quaternions) at a rate of up to 4 solutions per second, and may be configured to acquire images of selected targets for science and engineering analysis. The system tracks and catalogs objects that pass through the imager field of view and also provides a continuous record of radiation exposure. A spacecraft magnetic control program was implemented to provide a magnetically clean environment for the magnetic sensors, and residual spacecraft fields andor sensor offsets are monitored in flight taking advantage of Juno's spin (nominally 2 rpm) to separate environmental fields from those that rotate with the spacecraft.
Purpose: Use of high density concrete for radiation shielding is increasing, trading cost for space savings associated with the reduced tenth value layer (TVL). Precise information on the attenuation properties of high-density concretes is not readily present in the literature. A simple approximation is to scale the TVLs from NCRP 151 according relative increase in density. Here we present measured TVLs for heavy concretes of various densities using a built-in shielding test port. Methods: Concrete densities tested range from 2.35 g cc{sup −1} (147 pcf) to 5.6 g cc{sup −1} (350 pcf). Measurements were taken using 6MV, 6FFF, and 10FFF on a Varian Truebeam linear accelerator. Field sizes of 4x4, 9x9 and 30x30 cm{sup 2} were measured. A PTW 31013 Farmer chamber with a buildup cap was positioned 5.5 m from isocenter along the beam CAX. Concrete thicknesses were incremented in 5 cm intervals. Comparison TVLs were determined by scaling the NCRP 151 TVLs by the density ratio between the sample and standard density. Results: The trend from the first to equilibrium TVL was an increase in thickness, compared with MC modeling, which predicted a decrease. Measured TVLs for 6 MV were reduced by as much as 8.9 cm for TVL{sub 1} and 3.4 cm for TVL{sub E} compared to values scaled from NCRP 151. There was 1–3 mm difference in TVL between measurements done at 4x4 versus 30x30 cm{sup 2}. TVL{sub 1} for 6FFF was 1.1 cm smaller than TVL{sub 1} for 6MV, but TVL{sub E} was consistent to within 4 mm. TVL{sub 1} and TVL{sub E} for 10FFF were reduced by 8.8 and 3.7 cm from scaled NCRP values, respectively. Conclusions: We have measured the TVL thicknesses for various concretes. Simple density scaling of the values in NCRP 151 is a conservatively safe approximation, but actual TVLs may be reduced enough to eliminate some of the expense of installation. Daniel Harrell and Jim Noller are employees of Shielding Construction Solutions, Inc, the shielding construction company that built the vault discussed in this abstract. Manjit Chopra is an employee of Universal Minerals International, Inc, the company that provided the aggregates for the high density concretes used in the vault construction.
NASA has continued the development of space systems by applying and integrating improved technologies that include safety issues, lightweight materials, and electronics. One such area is extravehicular (EVA) spacesuit development with the most recent Mark III spacesuit. In this paper the Mark III spacesuit is discussed in detail that includes the various components that comprise the spacesuit, materials and their chemical composition that make up the spacesuit, and a discussion of the 3-D CAD model of the Mark III spacesuit. In addition, the male (CAM) and female (CAF) computerized anatomical models are also discussed in detail. We combined the spacesuit and the human models, that is, we developed a method of incorporating the human models in the Mark III spacesuit and performed a ray-tracing technique to determine the space radiation shielding distributions for all of the critical body organs. These body organ shielding distributions include the BFO (Blood-Forming Organs), skin, eye, lungs, stomach, and colon, to name a few, for both the male and female. Using models of the trapped (Van Allen) proton and electron environments, radiation exposures were computed for a typical low earth orbit (LEO) EVA mission scenario including the geostationary (GEO) high electron environment. A radiation exposure assessment of these mission scenarios is made to determine whether or not the crew radiation exposure limits are satisfied, and if not, the additional shielding material that would be required to satisfy the crew limits.
The Radiation Tolerant Intelligent Memory Stack (RTIMS), suitable for both geostationary and low earth orbit missions, has been developed. The memory module is fully functional and undergoing environmental and radiation characterization. A self-contained flight-like module is expected to be completed in 2006. RTIMS provides reconfigurable circuitry and 2 gigabits of error corrected or 1 gigabit of triple redundant digital memory in a small package. RTIMS utilizes circuit stacking of heterogeneous components and radiation shielding technologies. A reprogrammable field programmable gate array (FPGA), six synchronous dynamic random access memories, linear regulator, and the radiation mitigation circuitries are stacked into a module of 42.7mm x 42.7mm x 13.00mm. Triple module redundancy, current limiting, configuration scrubbing, and single event function interrupt detection are employed to mitigate radiation effects. The mitigation techniques significantly simplify system design. RTIMS is well suited for deployment in real-time data processing, reconfigurable computing, and memory intensive applications.
The possibility of metal-carbon nanocomposites synthesis by chemical deposition of nickel particles on powdered activated carbon has shown. The regularities of electromagnetic radiation interaction in the frequency range of 8–12 GHz with these nanocomposites have investigated depending on the composition of water solutions used in the process of their synthesis. Based on the results of such a study, the prospect of metal-carbon nanocomposites using for making of effective electromagnetic radiation shields and radio-absorbing materials has proved.
Indirect drive inertial confinement fusion (ICF) experiments to date have mostly used cylindrical, laser-heated, gas-filled hohlraums to produce the radiation drive needed to symmetrically implode DT-filled fusion capsules. These hohlraums have generally been unable to produce a symmetric radiation drive through the end of the desired drive pulse, and are plagued with complications due to laser-plasma interactions (LPI) that have made it difficult to predict their performance. In this project we developed several alternate hohlraum concepts. These new hohlraums utilize different hohlraum geometries, radiation shields, and foam materials in an attempt to improve performance relative to cylindrical hohlraums. Each alternate design was optimized using radiation hydrodynamic (RH) design codes to implode a reference DT capsule with a high-density carbon (HDC) ablator. The laser power and energy required to produce the desired time-dependent radiation drive, and the resulting time-dependent radiation symmetry for each new concept were compared to the results for a reference cylindrical hohlraum. Since several of the new designs needed extra laser entrance holes (LEHs), techniques to keep small LEHs open longer, including high-Z foam liners and low-Z wires at the LEH axis, were investigated numerically. Supporting experiments and target fabrication efforts were also done as part of this project. On the Janus laser facility plastic tubes open at one end (halfraums) and filled with SiO 2 or Ta 2 O 5 foam were heated with a single 2w laser. Laser propagation and backscatter were measured. Generally the measured propagation was slower than calculated, and the measured laser backscatter was less than calculated. A comparable, scaled up experiment was designed for the NIF facility and four targets were built. Since low density gold foam was identified as a desirable material for lining the LEH and the hohlraum wall, a technique was developed to produce 550 mg/cc gold foam, and a sample of this material was successfully manufactured.