Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Final Report: Non-Visible, Automated Target Acquisition and Tracking

The Roadside Tracker (RST) represents a new approach to radiation portal monitors. It uses a combination of gamma-ray and visible-light imaging to localize gamma-ray radiation sources to individual vehicles in free-flowing, multi-lane traffic. Deployed as two trailers that are parked on either side of the roadway (Fig. 1); the RST scans passing traffic with two large gamma-ray imagers, one mounted in each trailer. The system compensates for vehicle motion through the imager’s fields of view by using automated target acquisition and tracking (TAT) software applied to a stream of video images. Once a vehicle has left the field of view, the radiation image of that vehicle is analyzed for the presence of a source, and if one is found, an alarm is sounded. The gamma-ray image is presented to the operator together with the video image of the traffic stream when the vehicle was approximately closest to the system (Fig. 2). The offending vehicle is identified with a bounding box to distinguish it from other vehicles that might be present at the same time. The system was developed under a previous grant from the Department of Homeland Security’s (DHS’s) Domestic Nuclear Detection Office (DNDO). This report documents work performed with follow-on funding from DNDO to further advance the development of the RST. Specifically, the primary thrust was to extend the performance envelope of the system by replacing the visible-light video cameras used by the TAT software with sensors that would allow operation at night and during inclement weather. In particular, it was desired to allow operation after dark without requiring external lighting. As part of this work, the system software was also upgraded to allow the use of 64-bit computers, the current generation operating system (OS), software development environment (Windows 7 vs. Windows XP, and current Visual Studio.Net), and improved software version controls (GIT vs. Source Safe.) With the upgraded performance allowed by new computers, and the additional memory available in a 64-bit OS, the system was able to handle greater traffic densities, and this also allowed addition of the ability to handle stop-and-go traffic.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Nuclear Smuggling Detection and Deterrence (FY 2018 Data Analysis Annual Report)

The National Nuclear Security Administration’s Office of Nuclear Smuggling Detection and Deterrence (NSDD) has facilitated the installation of more than 3,728 radiation portal monitors (RPMs) at 660 sites in 63 countries. This collection of RPMs represents the world’s largest network of radiation detectors and provides one element of the defense-in-depth approach that supports the Global Nuclear Detection Architecture. These systems support NSDD’s mission to build partner country capability to deter, detect, and interdict the illicit transport of radiological and fissile material through strategic points of entry and exit at seaports, airports, and border crossings.NSDD works collaboratively with partner countries and international organizations to optimize the operation of these RPMs. The large amount of data provided by NSDD partner countries (summarized in the banner to the right) highlights the close cooperation and partnerships NSDD has built with 63 countries around the world. Thirty-two of these countries shared at least some RPM-related data with NSDD in fiscal year (FY) 2018. This significant level of data sharing is a key element that distinguishes the NSDD office as unique among nuclear nonproliferation programs and initiatives: NSDD can provide specific, objective, data-driven decisions and support for sustaining the radiation detection systems it helped deploy. This data analysis report summarizes and aggregates the RPM data provided to the NSDD office for analysis and review in FY 2018.The data can be used to describe RPM performance and characterize the wide diversity of NSDD deployment sites. For example, NSDD deploys detector systems across sites with natural background radiation levels that can vary by a factor of up to nine from site to site. Some RPM lanes have few occupancies, whereas others have up to approximately 8,000 occupancies per day, and the different types of cargo traveling through a site can result in site-wide alarm rates that range from near 0% at some sites to above 3% at others. Based on the data received, the global average uptime for NSDD RPMs was 97% for FY 2018. NSDD takes all these factors into account in making recommendations to partner countries on how to most effectively manage and maintain site operations. NSDD utilizes reports and other information products created by ORNL Radiation Inspection Systems Team (RIST) data analysts to efficiently allocate the resources needed to detect and ultimately interdict illicit nuclear and radiological material.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

IR Camera Report for the 7 Day Production Test

The following report gives a summary of the IR camera performance results and data for the 7 day production run that occurred from 10 Sep 2015 thru 16 Sep 2015. During this production run our goal was to see how well the camera performed its task of monitoring the target window temperature with our improved alignment procedure and emissivity measurements. We also wanted to see if the increased shielding would be effective in protecting the camera from damage and failure.

43 PARTICLE ACCELERATORS↗

Neutron sensitivity and detection efficiency of {sup 3}He and {sup 10}BF{sub 3} counters

An analytic relationship between the efficiency, sensitivity, and the coefficient of working-isotope utilization is established for gas-filled cylindrical thermal-neutron counters. This dependence is expressed in terms of the ratio of the characteristic length of a counter to its diameter. The characteristic size is introduced as the ratio of the total absorption cross section to the length of the counter. The parameters of basic {sup 3}He and {sup 10}BF{sub 3} counters used in NM-64 neutron monitors are calculated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear Smuggling Detection and Deterrence FY 2016 Data Analysis Annual Report

The National Nuclear Security Administration’s Office of Nuclear Smuggling Detection and Deterrence (NSDD) has facilitated the installation of more than 3,500 radiation portal monitors (RPMs) at 606 sites in 56 countries worldwide. This collection of RPMs represents the world’s largest network of radiation detectors and provides one element in the defense-in-depth approach that supports the Global Nuclear Detection Architecture. These systems support NSDD’s mission to build partner country capability to deter, detect, and interdict the illicit transport of radiological and fissile material through strategic points of entry and exit at seaports, airports, and border crossings. NSDD works collaboratively with partner countries and international organizations to optimize the operation of these RPMs. The large amount of data provided by NSDD partner countries highlights the close cooperation and partnerships NSDD has built with 56 countries around the world. Thirty-seven of these countries shared at least some RPM-related data with NSDD in fiscal year 2016. This significant level of data sharing is a key element that distinguishes the NSDD office as unique among nuclear nonproliferation programs and initiatives: NSDD can provide specific, objective, data-driven decisions and support for sustaining the radiation detection systems it helped deploy. This data analysis report summarizes and aggregates the RPM data provided to the NSDD office for analysis and review in fiscal year 2016. The data can be used to describe RPM performance and characterize the wide diversity of NSDD deployment sites. For example, NSDD deploys detector systems across sites with natural background radiation levels that can vary by a factor of approximately six from site to site. Some lanes have few occupancies, whereas others have approximately 8,000 occupancies per day and the different types of cargo that travel through a site can result in site-wide alarm rates that range from near 0% at some sites to above 3% at others. Based on the data received, the global average uptime for NSDD RPMs was above 96% for fiscal year 2016. NSDD takes all of these factors into account in making recommendations to partner countries on how to most effectively manage and maintain site operations. NSDD utilizes reports and other information products created by data analysts to efficiently allocate the resources needed to detect and ultimately interdict illicit nuclear and radiological material.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Restoration and Reexamination of Apollo Lunar Dust Detector Data from Original Telemetry Files

We are recovering the original telemetry (Figure I) from the Apollo Dust, Thermal, Radiation Environment Monitor (DTREM) experiment, more commonly known as the Dust Detector, and producing full time resolution (54 second) data sets for release through the Planetary Data System (PDS). The primary objective of the experiment was to evaluate the effect of dust deposition, temperature, and radiation damage on solar cells on the lunar surface. The monitor was a small box consisting of three solar cells and thermistors mounted on the ALSEP (Apollo Lunar Surface Experiments Package) central station. The Dust Detector was carried on Apollo's 11, 12, 14 and 15. The Apollo 11 DTREM was powered by solar cells and only operated for a few months as planned. The Apollo 12, 14, and 15 detectors operated for 5 to 7 years, returning data every 54 seconds, consisting of voltage outputs from the three solar cells and temperatures measured by the three thermistors. The telemetry was received at ground stations and held on the Apollo Housekeeping (known as "Word 33") tapes. made available to the National Space Science Data Center (NSSDC) by Yosio Nakamura (University of Texas Institute for Geophysics). We have converted selected parts of the telemetry into uncalibrated and calibrated output voltages and temperatures.

McBride, M. J.↗

Integrating and Live-time Radiation Dosimetry by Optical Crystal Damage, Initial Results with Neutrons

Radiation damage can be assessed through many techniques, though the assessment is usually offline and shows only integrated dose. Transparent crystals can be optically monitored for radiation damage nondestructively, to serve as a detector for both immediate dose and integrated dose for signatures of radiation exposure history. There is also some difference in gamma-ray and neutron interactions which can be observed. Gamma ray interactions primarily produce electron displacements, which are preserved as color centers in ionic crystals and produce specific spectral absorption lines. Neutron interactions strongly produce lattice displacements that affect the index of refraction. The differences may allow us to use inexpensive crystals for long time neutron monitoring. Spectroscopic absorption lines can be quantified using prior technology, but due to prior limits in phase sensitivity there was no previous use of index of refraction measurements. Using novel techniques based on intracavity phase interferometry to assess lattice displacements, we are able to examine neutron irradiation in CaF2 crystals. Initial results with neutrons will be presented.

99 GENERAL AND MISCELLANEOUS↗

SU-E-T-595: Output Factor Calculation for a Uniform Scanning Proton Therapy System

Purpose: To develop an analytical model that predicts dose output factors for patient treatment fields in a uniform scanning proton therapy system. Methods: A model to predict output factors for patient specific treatment fields was produced based on the methods developed by Kooy et al. (2003). The Kooy model predicts the output factor based on the ratio of the entrance dose under calibration conditions to that for a given range and modulation corrected for the inverse square effect. Field specific output factors were plotted as a function of a single parameter r, where r = (Range-Modulation)/Modulation. The model targeted user range 1 sub-span 3 through user range 2 sup-span 2 of the IBA uniform scanning proton therapy system. The data set included points measured using the 10 cm and 18 cm snout sizes to eliminate stem effects on the monitor unit chambers. The data was fit using equation 15 from Kooy et al. (2003), and the resulting model was tested against measurements that were not included in the original data set. Results: For the range and sub span investigated, 120 data points were tested against the model prediction. The model predicted the output factor within 2% for 96% of the points tested and within 2.5% for 99% of the points tested. All points were within 3% of the predicted values. Conclusion: Monitor units for patient treatment fields with proton ranges that fall within the tested interval can be predicted using a model based on the methods developed at MGH. With further evaluation, it will be possible to model all user ranges and sub-spans of the IBA system. Further testing is also needed to predict output factors using a 25 cm snout which introduces variable scanning pattern sizes and stem effects on the monitor unit chambers.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Section 106 Evaluation of Building CP-1, Area 6, Nevada National Security Site, Nye County, Nevada

On December 17, 2015, the National Nuclear Security Administration Nevada Field Office (NNSA/NFO) vacated Building CP-1 (Building 06-CP-1) on the Nevada National Security Site (NNSS) in Nye County, Nevada. Starting in 1951, nearly all nuclear tests during the Cold War were controlled from this building on the facility, known as the Nevada Test Site for most of its years of operation. The test site was renamed the NNSS in 2010. CP-1 was the command and control center where decisions about NNSS activities were sought and made; where authorization for movements about the areas forward (north) of Mercury base camp were coordinated, granted or declined, and monitored; and where problems and emergencies in the forward areas were communicated and relayed to the appropriate agencies for solution. Some of the testing duties for the Control Point included the timing and firing of nuclear tests, air operations, security, communications, weather monitoring, and radiation safety. During tests, communications were maintained through various channels to receive and pass instructions or information to the numerous testing operations, to Washington, D.C., the national laboratories, and overhead aircraft monitoring the tests. At one time, the Security Control Center, a Class A Weather Station, and the Radiation Safety Headquarters were located in CP-1, which also contained a cafeteria, a dining area, and bunk rooms. This survey was prompted by recognition that closure of the building in place creates a situation where CP-1 is vulnerable to decay in its present and unused condition. Activities at CP-1 have been reduced gradually over time since the end of nuclear testing in 1992. The Area of Potential Effects (APE) was determined by NNSA/NFO to be a two-acre area historically considered the space directly associated with CP-1 and available to CP-1 personnel for use. The APE is bounded on the south by an unnamed main paved road into the guarded Control Point area, on the west by the edge of the parking lot for adjacent Building CP-9, on the east by the edge of the bladed cut-and-fill terrace for CP-1, and on the north by a barbed wire security fence (Figure 2). All of this lot is either bladed or covered with asphalt. Contained within the lot are eight Accessary Resources (AR) which are much more closely aligned with CP-1 than with adjacent buildings. AR are defined by the Nevada State Historic Preservation Office (SHPO) (2013) as “…related but subordinate to the principal building. Accessory resources would not exist were it not for the principal resource.” The Visual APE was determined by NNSA/NFO to be the same as the APE used for intensive survey because no exterior modifications to the resource are anticipated. The APE is located in Section 34 T11S R53E MDBM (projected) within the NNSS base called the Control Point in Area 6. It is on the 1986 Yucca Lake USGS 7.5 min. series topographic quadrangle. The Desert Research Institute (DRI) surveyed the APE with the assistance of National Security Technologies, LLC (NSTec), resulting in recordation and evaluation of CP-1 (SHPO Resource Number B14490) and eight accessory resources (AR1-AR8). This recording of CP-1 was done in three sessions. Copies of the building form and report are on file at Nevada Cultural Resources Information System (NVCRIS), DRI, and with the NNSA/NFO, Las Vegas, Nevada. Control Point refers to the support facilities of which Building CP-1, with its 126 rooms, is the most important part (Campbell et al. 1983:165). CP-1 refers to the entire building but it also is the designation for the first phase of construction, i.e. the original building. There were three major subsequent phases of additions to the building. The first two were called CP-1A (the east wing) and CP-1B (the west wing with the new War Room). A final phase filled in the hyphen between CP-1 and CP-1B with a Field Office. For convenience this last phase is called CP-1C in this report. Hence, CP-1 can refer either the entire building or to the first phase of the building exclusive of additions. The context makes clear which of the two meanings is intended in the various sections of this report. There were also two minor expansions consisting of a small battery room and a shelter for an emergency exit.

54 ENVIRONMENTAL SCIENCES↗

Twenty Years of Radiation Measurements in Low-Earth Orbit - What Have We Learned Space Radiation Environment?

The advent of the Space Shuttle program has made possible space radiation environment measurements spanning a wide range of altitudes and orbital inclinations over multiple solar cycles. These measurements range from routine integral dose measurements with thermoluminescent dosimeters to particle energy spectra measurements made with a charged particle telescope. This paper will review the new understanding about the space radiation environment gained from this diverse data set. Major findings from these measurements include: estimations of the westward drift rate of the South Atlantic Anomaly (SAA) of 0.28-0.49/y; evidence for a northward component to the SAA drift of 0.08-0.12/y; observation of the formation and decay of the pseudo-stable additional radiation belt following the Mar 1991 SPE and geomagnetic storm with an estimated decay e-folding time of 9-10 months; observation of a local geomagnetic east-west trapped proton exposure anisotropy with an estimated magnitude of 1.6-3.3; demonstration that the trapped proton exposure in low-Earth orbit (LEO) can be reasonably modeled as a power law function of atmospheric density in the SAA region, with best correlations obtained when the exospheric temperature saturates at 938-975 K; the actual solar cycle modulation of trapped proton exposure in LEO is less than predicted by the AP8 model; and the testing and validation of GCR flux models, radiation transport codes, and dynamic geomagnetic cutoff models. Long-term, time-resolved proportional counter measurements made aboard the Mir during the same period provides further demonstration of the solar cycle modulation of the trapped protons at low altitudes - the observed modulation is also well described as power law function of atmospheric density. These data and findings have helped to improve the overall accuracy of pre-mission crew exposure projections using various semi-empirical space environment models, radiation transport codes, and spacecraft radiation shielding models. During the rise phase of solar cycle 22 (1987-1991), the RMS error between preflight exposure projections and measured crew exposure was 73%. For the rise phase of cycle 23 (1997-2001), the preflight exposure projection RMS error has decreased to 23%. The launch and assembly of the Space Station has begun a new era of long-term LEO space environment monitoring. The radiation environment at the Space Station will be monitored with three external charged particle telescopes oriented in the velocity vector, anti-velocity vector, and zenith directions. Data from the telescopes will provide charge, mass, energy, and arrival direction for incident particles with energy to mass ratios of 13- 450 MeV/amu and Z of 1-24. The external environment data will be complimented by measurements from a portable charged particle telescope and proportional counter located inside the vehicle.

Golightly, Michael J.↗

THE VARIABLE QUIESCENT X-RAY EMISSION OF THE TRANSIENT NEUTRON STAR XTE J1701-462

We present the results of continued monitoring of the quiescent neutron star low-mass X-ray binary XTE J1701-462 with Chandra and Swift. A new Chandra observation from 2010 October extends our tracking of the neutron star surface temperature from {approx_equal}800 days to {approx_equal}1160 days since the end of an exceptionally luminous 19 month outburst. This observation indicates that the neutron star crust may still be slowly cooling toward thermal equilibrium with the core; another observation further into quiescence is needed to verify this. The shape of the overall cooling curve is consistent with that of a broken power law, although an exponential decay to a constant level cannot be excluded with the present data. To investigate possible low-level activity, we conducted a monitoring campaign of XTE J1701-462 with Swift during 2010 April-October. Short-term flares-presumably arising from episodic low-level accretion-were observed up to a luminosity of {approx}1 x 10{sup 35} erg s{sup -1}, {approx}20 times higher than the normal quiescent level. We conclude that flares of this magnitude are not likely to have significantly affected the equilibrium temperature of the neutron star and are probably not able to have a measurable impact on the cooling curve. However, it is possible that brighter and longer periods of low-level activity have had an appreciable effect on the equilibrium temperature.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiation dose from reentrant electrons

In estimating the crew exposures during an extra vehicular activity (EVA), the contribution of reentrant electrons has always been neglected. Although the flux of these electrons is small compared to the flux of trapped electrons, their energy spectrum extends to several GeV compared to about 7 MeV for trapped electrons. This is also true of splash electrons. Using the measured reentrant electron energy spectra, it is shown that the dose contribution of these electrons to the blood forming organs (BFO) is more that 10 times greater than that from the trapped electrons. The calculations also show that the dose-depth response is a very slowly changing function of depth, and thus adding reasonable amounts of additional shielding would not significantly lower the dose to BFO. Published by Elsevier Science Ltd.

NASA Center JSC↗

CONSTRAINTS ON THE SYNCHROTRON SHOCK MODEL FOR THE FERMI GRB 090820A OBSERVED BY GAMMA-RAY BURST MONITOR

Discerning the radiative dissipation mechanism for prompt emission in gamma-ray bursts (GRBs) requires detailed spectroscopic modeling that straddles the {nu}F{sub {nu}} peak in the 100 keV-1 MeV range. Historically, empirical fits such as the popular Band function have been employed with considerable success in interpreting the observations. While extrapolations of the Band parameters can provide some physical insight into the emission mechanisms responsible for GRBs, these inferences do not provide a unique way of discerning between models. By fitting physical models directly, this degeneracy can be broken, eliminating the need for empirical functions; our analysis here offers a first step in this direction. One of the oldest, and leading, theoretical ideas for the production of the prompt signal is the synchrotron shock model. Here we explore the applicability of this model to a bright Fermi gamma-ray burst monitor (GBM) burst with a simple temporal structure, GRB 090820A. Our investigation implements, for the first time, thermal and non-thermal synchrotron emissivities in the RMFIT forward-folding spectral analysis software often used in GBM burst studies. We find that these synchrotron emissivities, together with a blackbody shape, provide at least as good a match to the data as the Band GRB spectral fitting function. This success is achieved in both time-integrated and time-resolved spectral fits.

79 ASTRONOMY AND ASTROPHYSICS↗

Evidence for Radiation-Induced Disseminated Intravascular Coagulation as a Major Cause of Radiation-Induced Death in Ferrets

Purpose: The studies reported here were performed as part of a program in space radiation biology in which proton radiation like that present in solar particle events, as well as conventional gamma radiation, were being evaluated in terms of the ability to affect hemostasis. Methods and Materials: Ferrets were exposed to 0 to 2 Gy of whole-body proton or gamma radiation and monitored for 30 days. Blood was analyzed for blood cell counts, platelet clumping, thromboelastometry, and fibrin clot formation. Results: The lethal dose of radiation to 50% of the population (LD{sub 50}) of the ferrets was established at ∼1.5 Gy, with 100% mortality at 2 Gy. Hypocoagulability was present as early as day 7 postirradiation, with animals unable to generate a stable clot and exhibiting signs of platelet aggregation, thrombocytopenia, and fibrin clots in blood vessels of organs. Platelet counts were at normal levels during the early time points postirradiation when coagulopathies were present and becoming progressively more severe; platelet counts were greatly reduced at the time of the white blood cell nadir of 13 days. Conclusions: Data presented here provide evidence that death at the LD{sub 50} in ferrets is most likely due to disseminated intravascular coagulation (DIC). These data question the current hypothesis that death at relatively low doses of radiation is due solely to the cell-killing effects of hematopoietic cells. The recognition that radiation-induced DIC is the most likely mechanism of death in ferrets raises the question of whether DIC is a contributing mechanism to radiation-induced death at relatively low doses in large mammals.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of the response of tritium-in-air instrumentation to HT in dry and humid conditions and to HTO vapor

Nuclear plant operators (power generation, decommissioning and reprocessing operations) are required to monitor releases of tritium species for regulatory compliance and radiation protection purposes. Tritium monitoring is performed using tritium-in-air gas monitoring instrumentation based either on flow-through ion chambers or proportional counting systems. Tritium-in-air monitors are typically calibrated in dry conditions but in service may operate at elevated levels of relative humidity. The NPL (National Physical Laboratory) radioactive gas-in-air calibration system has been used to study the effect of humidity on the response to tritium of two tritium-in-air ion chamber based monitors and one proportional counting system which uses a P10/air gas mixture. The response of these instruments to HTO vapour has also been evaluated. In each case, instrument responses were obtained for HT in dry conditions (relative humidity (RH) about 2%), HT in 45% RH, and finally HTO at 45% RH. Instrumentation response to HT in humid conditions has been found to slightly exceed that in dry conditions. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

3He and BF3 Neutron Detector Pressure Effect and Model Comparison

Paper for SORMA conference Radiation detection systems for homeland security applications must possess the capability of detecting both gamma rays and neutrons. The radiation portal monitor (RPM) systems that are currently deployed use a plastic scintillator for detecting gamma rays and 3He gas-filled proportional counters for detecting neutrons. Proportional counters filled with 3He are the preferred neutron detectors for use in RPMs because 3He has a large neutron cross section, is relatively insensitive to gamma-rays, is neither toxic nor corrosive, can withstand extreme environments, and can be operated at a lower voltage than some of the alternative proportional counters. The amount of 3He required for homeland security and science applications has depleted the world supply and there is no longer enough available to fill the demand. Thus, alternative neutron detectors are being explored. Two possible temporary solutions that could be utilized while a more permanent solution is being identified are reducing the 3He pressure in the proportional counters and using boron trifluoride (BF3) gas-filled proportional counters. Reducing the amount of 3He required in each of the proportional counters would decrease the rate at which 3He is being used, not enough to solve the shortage but perhaps enough to increase the amount of time available to find a working replacement. BF3 is not appropriate for all situations as these detectors are less sensitive than 3He, BF3 gas is corrosive, and a much higher voltage is required than what is used with 3He detectors. Measurements of the neutron detection efficiency of 3He and BF3 as a function of tube pressure were made. The experimental results were also used to validate models of the RPMs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ESH-ASI-2021-004 DOE Annual Letter (redacted markings)

File LLNL2020_DOE_GI_ANNUAL.txt was submitted electronically to the REIRS file submission. The file contains positive and zero doses for 3,308 Lawrence Livermore National Security (LLNS) and subcontractor employees. There were 96 individuals with a collective Total Effective Dose (TED) of 6,886 mrem. The 2020 data follow the DOE Radiation Exposure Monitoring Systems (REMS) format per instructions in the REMS Reporting Guide.

61 RADIATION PROTECTION AND DOSIMETRY↗