Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precision measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Very long baseline IPS observations of the solar wind speed in the fast polar streams

Observations of intensity scintillation (IPS) with two or more spaced antennas have been widely used to measure the solar wind velocity. Such methods are particularly valuable in regions which spacecraft have not yet penetrated, but they are also very useful in improving the spatial temporal sampling of the solar wind, even in regions where spacecraft data are available. The principle of the measurement is to measure the time delay tau(sub d) between the scintillations observed with an antenna baseline b. The velocity estimate is just V = b/tau(sub d). The error in estimation of the time delay delta tau(sub d) is independent of the baseline length, thus the error in the velocity estimate delta V given by delta(V)/V approximately equals to (delta tau(sub d))/tau(sub d) is inversely proportional to tau(sub d) and hence to b. However the use of a long baseline b has a less obvious advantage; it provides a means for separating fast and slow contributions when both are present in the scattering region. Here we will present recent observations made using the large cylinder antenna at Ooty in the Nilgiri Hills of South India, and one of the 45 m dishes of GMRT near Pune in West-Central India. The baseline of 900 km is, by a considerable margin, the longest ever used for IPS and provides excellent velocity resolution. These results compared with the ULYSSES observations and other IPS measurements made closer to the sun with higher frequency instruments such as EISCAT and the VLBA will provide a precise measure of the velocity profile of the fast north-polar stream.

Rao, A. Pramesh↗

Status and Progress on the Upgraded Infrared Spatial Interferometer

The U.C. Berkeley Infrared Spatial Interferometer is a two telescope stellar interferometer operating in the 9-12 micron atmospheric window, utilizing heterodyne detection with CO2 laser local oscillators. Science with the ISI has been focused on the measurements of the spatial distribution of dust and molecules around mass-losing late type stars, and more recently precision measurements of stellar diameters in the mid-infrared avoiding molecular lines. Also during the past few years, a NSF sponsored program of expansion from two to three telescopes has been underway. This expansion will allow the ISI to make visibility observations on three simultaneous baselines and a measure a closure phase. The third telescope was completed last year and shipped to Mt. Wilson, and more recently a Central Control Facility and Master Laser Oscillator Facility were also completed and recently shipped to Mt. Wilson. In this talk we report progress on this program and highlight some of the most recent astrophysical results.

Danchi, W. C.↗

1999-2003 Shortwave Characterizations of Earth Radiation Budget Satellite (ERBS)/Earth Radiation Budget Experiment (ERBE) Broadband Active Cavity Radiometer Sensors

From October 1984 through May 2005, the NASA Earth Radiation Budget Satellite (ERBS/ )/Earth Radiation Budget Experiment (ERBE)ERBE nonscanning active cavity radiometers (ACR) were used to monitor long-term changes in the earth radiation budget components of the incoming total solar irradiance (TSI), earth-reflected TSI, and earth-emitted outgoing longwave radiation (OLR). From September1984 through September 1999, using on-board calibration systems, the ERBS/ERBE ACR sensor response changes, in gains and offsets, were determined from on-orbit calibration sources and from direct observations of the incoming TSI through calibration solar ports at measurement precision levels approaching 0.5 W/sq m , at satellite altitudes. On October 6, 1999, the onboard radiometer calibration system elevation drive failed. Thereafter, special spacecraft maneuvers were performed to observe cold space and the sun in order to define the post-September 1999 geometry of the radiometer measurements, and to determine the October 1999-September 2003 ERBS sensor response changes. Analyses of these special solar and cold space observations indicate that the radiometers were pointing approximately 16 degrees away from the spacecraft nadir and on the anti-solar side of the spacecraft. The special observations indicated that the radiometers responses were stable at precision levels approaching 0.5 W/sq m . In this paper, the measurement geometry determinations and the determinations of the radiometers gain and offset are presented, which will permit the accurate processing of the October 1999 through September 2003 ERBE data products at satellite and top-of-the-atmosphere altitudes.

Lee, Robert B., III↗

Measurement of the W boson decay branching fraction ratio $\mathscr{B}$(W → cq)/$\mathscr{B}$(W →$q\bar{q}'$) in proton-proton collisions at $\sqrt{s}$ = 13 TeV

The most precise measurement to date of the W boson hadronic decay branching fraction ratio $R_{c}^{W} = \mathcal{B}(W \to cq) / \mathcal{B}(W \to q\bar{q}$) is presented. The measurement is based on a sample of proton-proton collision data from the CERN LHC collected by the CMS experiment at a center-of-mass energy of 13 TeV in 2016-2018 with an integrated luminosity of 138 fb$^{-1}$. The large cross section of top quark-antiquark production at the LHC offers a sizable high-purity sample of W bosons suitable for this measurement. Events with one charged lepton (electron or muon) and at least four jets, two tagged as bottom quark jets, are analyzed. Charm jets are tagged using the presence of a muon inside the jet. The result, $R_\mathrm{c}^\mathrm{W}$ = 0.489 $\pm$ 0.020, is consistent with the standard model prediction and is twice as precise as the current world-average value.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the Higgs boson mass with H → γγ decays in 140 fb –1 of $\sqrt{s}$ = 13 TeV pp collisions with the ATLAS detector

The mass of the Higgs boson is measured in the H→γγ decay channel, exploiting the high resolution of the invariant mass of photon pairs reconstructed from the decays of Higgs bosons produced in proton–proton collisions at a centre-of-mass energy $\sqrt{s}$ = 13 TeV. The dataset was collected between 2015 and 2018 by the ATLAS detector at the Large Hadron Collider, and corresponds to an integrated luminosity of 140 fb –1 . The measured value of the Higgs boson mass is 125.17 ± 0.11(stat.) ± 0.09(syst.) GeV and is based on an improved energy scale calibration for photons, whose impact on the measurement is about four times smaller than in the previous publication. A combination with the corresponding measurement using 7 and 8 TeV pp collision ATLAS data results in a Higgs boson mass measurement of 125.22 ± 0.11(stat.) ± 0.09(syst.) GeV. With an uncertainty of 1.1 per mille, this is currently the most precise measurement of the mass of the Higgs boson from a single decay channel.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigation of the isoscalar monopole response in the proton-rich nucleus 14 O

Deuteron inelastic scattering on 14 O was measured in inverse kinematics using an active-target time projection chamber and a magnetic spectrograph. The experimental technique enabled precise measurements of deuteron recoiling particles in coincidence with beam-like fragments detected in the spectrograph focal plane. The double differential cross section was reconstructed for scattering angles of 3–6 degrees and excitation energies up to 26 MeV. The monopole strength distribution was obtained from the data using a multipole decomposition analysis. The results were compared to quasiparticle random-phase approximation (QRPA) and generator coordinate method (GCM) calculations. The QRPA calculation accurately describes experimental data in the energy range of 13 to 26 MeV. GCM calculations assuming a 12 C (g . s .) + p + p cluster configuration were used to determine the 0 + strength in 14 O below 13 MeV. The monopole transition strength of these cluster states provides a good description of the experimental distribution in the 9–11 MeV region, while the 0$^{+}_{2}$ state accounts for only a small fraction of the experimental strength around 6 MeV.

Active target↗

Understanding the Origin of the Hadron Mass within the Standard Model

Understanding the origin of the hadron mass, which constitutes 99% of our visible universe, is one of the central goals of nuclear physics. Although the Higgs mechanism provides mass for the fundamental building blocks of matter, it can only contribute less than 2% of the proton mass. The vast majority of the proton mass is believed to come from the strong force that tightly binds quarks and gluons (collectively called partons) together as described by Quantum Chromodynamics (QCD). The mass that emerges as a consequence of the strong interactions within QCD is commonly denoted as Emergent Hadronic Mass (EHM). Understanding how the nucleon mass emerges in QCD is a prerequisite to an explanation of how the Universe came into being, therefore it is of utmost importance and one of the key questions to be addressed by the future Electron-Ion Collider (EIC). When it comes to light mesons, particularly pions, the mass decomposition is drastically different. Since the pion is naturally massless in the chiral limit, the majority of its observed mass needs to come from other mechanisms within QCD. Any successful explanation for the EHM needs to be able to reconcile both the heavy proton mass and the very light pion mass (~15% of proton mass) simultaneously. The EHM theories have direct measurable implications on the description of the internal structure of the hadron, i.e., how the partons distribute inside the hadron. Precise measurement of the parton distribution functions (PDFs) will provide necessary experimental verifications and constraints of potential EHM mechanisms. We propose to carry out a comprehensive study of the poorly known pion PDFs at the AMBER experiment at CERN. The measurement will provide vital input to constrain the global analysis of the pion PDFs, which are still based on limited data obtained more than 30 years ago. The proposed pion measurement is the only direct measurement achievable within this decade, which could lead to a future major meson structure program parallel to the EIC’s proton structure measurement.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hadron Production Measurements at NA61/SHINE

In current day measurements of neutrino oscillation parameters with accelerator-based neutrino experiments, neutrino flux uncertainties are frequently a leading systematic uncertainty. Precise measurements of primary and secondary hadron production processes for neutrino beams, performed by the NA61/SHINE experiment at CERN's Super Proton Synchrotron, can significantly constrain these uncertainties; the T2K experiment has incorporated previous NA61/SHINE measurements for a substantial flux uncertainty reduction. For these measurements, NA61/SHINE analyzes the interactions of charged hadrons with materials relevant to long-baseline experiments, measuring the differential cross sections of produced particles. This poster will review the NA61/SHINE experiment, including recent, ongoing, and future measurements with thin and replica targets, such as proton-carbon interactions at 31 GeV/c and 120 GeV/c for the T2K and DUNE experiments, respectively.

Allison, Kyle↗

Phase-curve Pollution of Exoplanet Transit Depths

The next generation of space telescopes will enable transformative science to understand the nature and origin of exoplanets. In particular, transit spectroscopy will reveal the chemical composition of the exoplanet atmospheres with unprecedented detail thanks to precise measurements of the visible-to-infrared transit depths down to 10 parts per million. Such a level of instrumental precision raises the challenge to obtain even more precise astrophysical models so as not to significantly influence the interpretation of the observed data. We must therefore critically revisit some of the commonly accepted assumptions that were adequate for analyzing past and current observations. A common approximation in the analysis of exoplanetary primary transits is that the planet does not contribute to the recorded flux, so-called dark planet hypothesis. In this paper, we investigate the impact of the dark planet hypothesis on the parameters obtained from the analysis of transits with particular attention to the transit depth. We develop mathematical formulae and release new software to estimate the magnitude of the potential bias. These tools will be useful in the preparation of observing proposals, as well as within the scientific consortia of the James Webb Space Telescope (JWST) and the Atmospheric Remote-sensing Infrared Exoplanet Large-survey (ARIEL) missions. We probe the accuracy of the mathematical formulae through the analysis of synthetic observations with the JWST Mid-InfraRed Instrument. We find that self-blending from nightside emission attenuates the transit depth by >3σ for some of the known exoplanet systems, in agreement with previous work. An additional unreported effect caused by the nightside rotating into view can also impart a significant effect, but in the opposite direction (increasing the transit depth); this effect can largely be removed with conventional detrending practices, at the expense of a slight increase in noise, and mixing astrophysical variations and instrumental drifts.

79 ASTRONOMY AND ASTROPHYSICS↗

Laser velocimeter survey about a NACA 0012 wing at low angles of attack

An investigation was conducted in the Langley V/STOL tunnel with a laser velocimeter to obtain measurements of airflow velocities about a wing at low angles of attack. The applicability of the laser velocimeter technique for this purpose in the V/STOL tunnel was demonstrated in this investigation with measurement precision bias calculated at -1.33 percent to 0.91 percent and a random uncertainty calculated at + or - 0.47 percent. Free stream measurements were obtained with this device and compared with velocity calculations from pitot static probe data taken near the laser velocimeter measurement location. The two measurements were in agreement to within 1 percent. Velocity measurement results about the centerline at 0.6 degrees angle of attack were typically those expected. At 4.75 degrees, the velocity measurements indicated that a short laminar separation bubble existed near the leading edge with an oscillating shear layer.

Hoad, D. R.↗

Reducing Centroid Error Through Model-Based Noise Reduction

A method of processing the digitized output of a charge-coupled device (CCD) image detector has been devised to enable reduction of the error in computed centroid of the image of a point source of light. The method involves model-based estimation of, and correction for, the contributions of bias and noise to the image data. The method could be used to advantage in any of a variety of applications in which there are requirements for measuring precise locations of, and/or precisely aiming optical instruments toward, point light sources. In the present method, prior to normal operations of the CCD, one measures the point-spread function (PSF) of the telescope or other optical system used to project images on the CCD. The PSF is used to construct a database of spot models representing the nominal CCD pixel outputs for a point light source projected onto the CCD at various positions incremented by small fractions of a pixel.

Lee, Shinhak↗

Search for CP violation and measurement of branching fractions and decay asymmetry parameters for Λ$^+_c$ → Λ h + and Λ$^+_c$ → Σ 0 h + ( h = K, π )

Here, we report a study of Λ$^+_c$ → Λ h + and Λ$^+_c$ → Σ 0 h + ( h = K, π ) decays based on a data sample of 980 fb -1 collected with the Belle detector at the KEKB energy-asymmetric e + e - collider. The first results of direct CP asymmetry in two-body singly Cabibbo-suppressed (SCS) decays of charmed baryons are measured, A$^{dir}_{CP}(Λ^+_{c} → ΛK^{+})$ = +0.021 ± 0.026 ± 0.001 and A$^{dir}_{CP}(Λ^+_{c} → Σ^{0}K^{+})$ = +0.025 ± 0.054 ± 0.004. We also make the most precise measurement of the decay asymmetry parameters (α) for the four modes of interest and search for CP violation via the α-induced CP asymmetry (A$^α_{CP}$ ). We measure A$^α_{CP}$ ($Λ^+_{c} → ΛK^{+}$) = -0.023 ± 0.086 ± 0.071 and A$^α_{CP}$ ($Λ^+_{c} → Σ^{0}K^{+}$) = +0.08 ± 0.35 ± 0.14, which are the first A$^α_{CP}$ results for SCS decays of charmed baryons. We search for Λ -hyperon CP violation in $Λ^+_{c}$ → (Λ, Σ 0 )π + and find A$^α_{CP}$(Λ → pπ - ) = +0.013 ± 0.007 ± 0.011 . This is the first time that hyperon CP violation has been measured via Cabibbo-favored charm decays. No evidence of baryon CP violation is found. We also obtain the most precise branching fractions for two SCS Λ$^+_c$ decays, $\mathscr{B}$($Λ^+_{c} → ΛK^{+}$) = (6.57 ± 0.17 ± 0.11 ± 0.35) x 10 -4 and $\mathscr{B}$($Λ^+_{c} → Σ^{0}K^{+}$) = (3.58 ± 0.19 ±0.06 ±0.19) x 10 -4 . The first uncertainties are statistical and the second systematic, while the third uncertainties come from the uncertainties on the world average branching fractions of $Λ^+_{c}$ → (Λ, Σ 0 )π + .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Carbon Dioxide Active Remote Sensing Using Pulsed 2-µm Lidar

A pulsed 2-µm Integrate Path Differential Absorption (IPDA) lidar was developed at NASA Langley Research Center for high-accuracy and high-precision measurements of atmospheric carbon dioxide (CO 2 ). The instrument targets the R30 CO 2 absorption line and implements high-energy tunable on-line transmitter and advanced HgCdTe avalanche photodiode receiver. During 2019 airborne validation campaign, the IPDA was tested over the ocean for retrieving the weighted-average column dry-air volume mixing ratio of CO 2 (XCO 2 ) from 4.5 km altitude. XCO 2 measurement resulted in 404.43 ± 1.23 ppm using 10 s average, as compared to 405.49 ppm from prediction models. This translates to 0.26% and 0.30% relative accuracy and precision, respectively. Performance models were updated to scale the IPDA technology assuming operation from space platform. Results present XCO 2 measurements using the instrument capabilities considering different target scenarios for Earth’s surface. This demonstrates the potential for the IPDA technique and technology to achieve sustained global CO 2 measurement.

Active Remote Sensing↗

Carbon Dioxide Active Remote Sensing Using Pulsed 2-µm Lidar

A pulsed 2-µm Integrate Path Differential Absorption (IPDA) lidar was developed at NASA Langley Research Center for high-accuracy and high-precision measurements of atmospheric carbon dioxide (CO 2 ). The instrument targets the R30 CO 2 absorption line and implements high-energy tunable on-line transmitter and advanced HgCdTe avalanche photodiode receiver. During 2019 airborne validation campaign, the IPDA was tested over the ocean for retrieving the weighted-average column dry-air volume mixing ratio of CO 2 (XCO 2 ) from 4.5 km altitude. XCO 2 measurement resulted in 404.43 ± 1.23 ppm using 10 s average, as compared to 405.49 ppm from prediction models. This translates to 0.26% and 0.30% relative accuracy and precision, respectively. Performance models were updated to scale the IPDA technology assuming operation from space platform. Results present XCO 2 measurements using the instrument capabilities considering different target scenarios for Earth’s surface. This demonstrates the potential for the IPDA technique and technology to achieve sustained global CO 2 measurement.

Active Remote Sensing↗

Miniature X-Ray Bone Densitometer

The purpose of the Dual Energy X-ray Absorptiometry (DEXA) project is to design, build, and test an advanced X-ray absorptiometry scanner capable of being used to monitor the deleterious effects of weightlessness on the human musculoskeletal system during prolonged spaceflight. The instrument is based on the principles of dual energy x-ray absorptiometry and is designed not only to measure bone, muscle, and fat masses but also to generate structural information about these tissues so that the effects on mechanical integrity may be assessed using biomechanical principles. A skeletal strength assessment could be particularly important for an astronaut embarking on a remote planet where the consequences of a fragility fracture may be catastrophic. The scanner will employ multiple projection images about the long axis of the scanned subject to provide geometric properties in three dimensions, suitable for a three-dimensional structural analysis of the scanned region. The instrument will employ advanced fabrication techniques to minimize volume and mass (100 kg current target with a long-term goal of 60 kg) of the scanner as appropriate for the space environment, while maintaining the required mechanical stability for high precision measurement. The unit will have the precision required to detect changes in bone mass and geometry as small as 1% and changes in muscle mass as small as 5%. As the system evolves, advanced electronic fabrication technologies such as chip-on-board and multichip modules will be combined with commercial (off-the-shelf) parts to produce a reliable, integrated system which not only minimizes size and weight, but, because of its simplicity, is also cost effective to build and maintain. Additionally, the system is being designed to minimize power consumption. Methods of heat dissipation and mechanical stowage (for the unit when not in use) are being optimized for the space environment.

Charles, Harry K., Jr.↗

Half-life of 67 Cu

The half-life of 67 Cu was determined through serial gamma-ray spectrometry measurements of the dominant gamma emission (E γ : 184.6 keV; branching ratio: 48.7%) produced following β- decay. Data were collected consecutively for 1000 s per measurement, with a total of 3063 measurements over the duration of 36 days. The incidence rate for the 184.6 keV gamma-ray was determined from the spectral peak area and duration of each measurement. This rate was then corrected to account for detector dead-time, radioactive decay during each acquisition and drift in the computer clock in comparison to NIST nuclear clock. Least-squares regression analysis was performed to determine the half-life of 67 Cu. The result was 61.761 ± 0.004 h, which is the highest precision measurement to date, and marks a 24-fold precision improvement over the current Nuclear Data Sheets value.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hybrid method for monitoring large Fabry-Pérot cavity displacements with nanometer precision

The change in length of an optical fiber-based Fabry-Pérot cavity (FPC) can be precisely measured using phase tracking, but the displacement range is limited by phase ambiguity. Period tracking techniques determine the absolute FPC length, but with larger uncertainties from tracking the spacing between multiple peaks. A hybrid method is demonstrated that identifies appropriate peaks for phase tracking using a coarse estimate obtained from the free spectral range to effectively maintain the high precision (∼1 nm) of phase tracking techniques to measure ∼24 µ m displacements, well beyond the range limitations (typically <1 µ m) of phase tracking methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗