Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Particle accelerator sciences”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Operation of the “Small” BioAMS spectrometers at CAMS: Past and future prospects

A summary of results from the solid samples run on our compact 1 MV AMS system over its 13.5 years of operation is presented. On average 7065 samples per year were measured with that average dropping to 3278 samples per year following the deployment of our liquid sample capability. Although the dynamic range of our spectrometer is 4.5 orders in magnitude, most of the measured graphitic samples had 14 C/C concentrations between 0.1 and 1 modern. Furthermore, the measurements of our ANU sucrose standard followed a Gaussian distribution with an average of 1.5082 ± 0.0134 modern. The LLNL biomedical AMS program supported many different types of experiments, however, the large majority of samples measured were derived from animal model systems. We have transitioned all of our biomedical AMS measurements to the recently installed 250 kV SSAMS instrument with good agreement compared in measured 14C/C isotopic ratios between sample splits. We then present results from replacement of argon stripping gas with helium in the SSAMS with a 22% improvement in ion transmission through the accelerator and high-energy analyzing magnet.

14C↗

From structure to cellular mechanism with infrared microspectroscopy

Current efforts in structural biology aim to integrate structural information within the context of cellular organization and function. X-rays and infrared radiation stand at opposite ends of the electromagnetic spectrum and act as complementary probes for achieving this goal. Intense and bright beams are produced by synchrotron radiation, and are efficiently used in the wavelength domain extending from hard X-rays to the far-infrared (or THz) regime. While X-ray crystallography provides exquisite details on atomic structure, Fourier transform infrared microspectroscopy (FTIRM) is emerging as a spectroscopic probe and imaging tool for correlating molecular structure to biochemical dynamics and function. In this manuscript, the role of synchrotron FTIRM in bridging the gap towards 'functional biology' is discussed based upon recent achievements, with a critical assessment of the contributions to biological and biomedical research.

43 PARTICLE ACCELERATORS↗

The need for reproducible research in soft robotics

In recent years we have witnessed the rise of commercialization efforts for soft robotic technology, including soft grippers (Soft Robotics, Inc.), stretchable sensors (StretchSense, Inc. and Lightlace, Inc.), and platforms for human-robot interaction (Festo Inc., Meta Reality Labs, Toyota Research Institute, and Disney Research). However, commercialization as a whole lags the trends enjoyed by other robotic technology at equivalent points in their respective lifecycles.

43 PARTICLE ACCELERATORS↗

The MANX Muon Cooling Experiment Detection System

The MANX experiment is being proposed to demonstrate the reduction of 6D muon phase space emittance, using a continuous liquid absorber to provide ionization cooling in a helical solenoid magnetic channel. The experiment involves the construction of a two-period-long helical cooling channel (HCC) to reduce the muon invariant emittance by a factor of two. The HCC would replace the current cooling section of the MICE experiment now being set up at the Rutherford Appleton Laboratory. The MANX experiment would use the existing MICE spectrometers and muon beam line. We discuss the placement of detection planes to optimize the muon track resolution.

43 PARTICLE ACCELERATORS↗

Status of the International Design Study of the Neutrino Factory

The International Design Study for the Neutrino Factory (the IDS-NF) has been established by the Neutrino Factory community to deliver the Reference Design Report (RDR) for the facility by 2012. The baseline design for the facility, developed from that defined in the International Scoping Study of a future Neutrino Factory and super-beam facility (the ISS), will provide 10{sup 21} muon decays per year from 25 GeV stored muon beams. The facility will serve two neutrino detectors; one situated at source-detector distance of between 3000-5000 km, the second at 7000-8000 km. The baseline design for the facility will be described and the status of the IDS-NF effort will be summarised.

43 PARTICLE ACCELERATORS↗

X-ray phase contrast imaging of biological specimens with femtosecond pulses of betatron radiation from a compact laser plasma wakefield accelerator

We show that x-rays from a recently demonstrated table top source of bright, ultrafast, coherent synchrotron radiation [Kneip et al., Nat. Phys. 6, 980 (2010)] can be applied to phase contrast imaging of biological specimens. Our scheme is based on focusing a high power short pulse laser in a tenuous gas jet, setting up a plasma wakefield accelerator that accelerates and wiggles electrons analogously to a conventional synchrotron, but on the centimeter rather than tens of meter scale. We use the scheme to record absorption and phase contrast images of a tetra fish, damselfly and yellow jacket, in particular highlighting the contrast enhancement achievable with the simple propagation technique of phase contrast imaging. Coherence and ultrafast pulse duration will allow for the study of various aspects of biomechanics.

43 PARTICLE ACCELERATORS↗

Measuring the NuMI Beam Flux for MINERvA

MINERvA is employing multiple tools to understand its neutrino beam flux. We utilize external hadron production data, but we also depend heavily on in situ techniques in which we reduce our hadron production uncertainties by tuning our Monte Carlo to both MINERvA detector data and muon monitor data.

43 PARTICLE ACCELERATORS↗

Demonstration of femtosecond X-ray pump X-ray probe diffraction on protein crystals

The development of X-ray free-electron lasers (XFELs) has opened the possibility to investigate the ultrafast dynamics of biomacromolecules using X-ray diffraction. Whereas an increasing number of structures solved by means of serial femtosecond crystallography at XFELs is available, the effect of radiation damage on protein crystals during ultrafast exposures has remained an open question. We used a split-and-delay line based on diffractive X-ray optics at the Linac Coherent Light Source XFEL to investigate the time dependence of X-ray radiation damage to lysozyme crystals. For these tests, crystals were delivered to the X-ray beam using a fixed-target approach. The presented experiments provide probe signals at eight different delay times between 19 and 213 femtoseconds after a single pump event, thereby covering the time-scales relevant for femtosecond serial crystallography. Even though significant impact on the crystals was observed at long time scales after exposure with a single X-ray pulse, the collected diffraction data did not show significant signal reduction that could be assigned to beam damage on the crystals in the sampled time window and resolution range. This observation is in agreement with estimations of the applied radiation dose, which in our experiment was clearly below the values expected to cause damage on the femtosecond time scale. The experiments presented here demonstrate the feasibility of time-resolved pump-multiprobe X-ray diffraction experiments on protein crystals.

43 PARTICLE ACCELERATORS↗

Cesium intercalation of graphene: A 2D protective layer on alkali antimonide photocathode

Alkali antimonide photocathodes have wide applications in free-electron lasers and electron cooling. The short lifetime of alkali antimonide photocathodes necessitates frequent replacement of the photocathodes during a beam operation. Furthermore, exposure to mediocre vacuum causes loss of photocathode quantum efficiency due to the chemical reaction with residual gas molecules. Theoretical analyses have shown that covering an alkali antimonide photocathode with a monolayer graphene or hexagonal boron nitride protects it in a coarse vacuum environment due to the inhibition of chemical reactions with residual gas molecules. Alkali antimonide photocathodes require an ultra-high vacuum environment, and depositing a monolayer 2D material on it poses a serious challenge. In the present work, we have incorporated a novel method known as intercalation, in which alkali atoms pass through the defects of a graphene thin film to create a photocathode material underneath. Initially, Sb was deposited on a Si substrate, and a monolayer graphene was transferred on top of the Sb film. Heat cleaning around 550–600 °C effectively removed the Sb oxides, leaving metallic Sb underneath the graphene layer. Depositing Cs on top of a monolayer graphene enabled the intercalation process. Atomic force microscopy, Raman spectroscopy, x-ray photoelectron spectroscopy, low energy electron microscopy, and x-ray diffraction measurements were performed to evaluate photocathode formation underneath the monolayer graphene. Our analysis shows that Cs penetrated the graphene and reacted with Sb and formed Cs 3 Sb.

2D materials↗

Characterization of Cs 3 Sb photocathodes at cryogenic temperatures

Here, we report measurements of quantum efficiency (QE) and mean transverse energy (MTE) from Cs 3 Sb photocathodes in a wide range of photon energies at both room and cryogenic temperatures. Our measurements show a strong temperature dependence of MTE even at photon energies well above threshold, indicating the presence of strong inelastic scattering of excited electrons during transport before emission into vacuum. We also demonstrate a cathode cooling method that largely preserves the QE while reducing MTE, allowing us to achieve MTEs as low as 58 meV with 3% QE in green light from Cs 3 Sb photocathodes. Our results are crucial for producing brighter electron beams for various photoinjector applications like ultrafast electron diffraction and microscopy, x-ray free-electron lasers, and particle colliders.

36 MATERIALS SCIENCE↗

MX Frontiers at the One Micron Scale: Making the Case for Micro-Beams

Macromolecular crystallographic (MX) structure determination at synchrotron radiation sources has the potential to advance significantly through use of X-ray beams of one micron or smaller cross-sections. Recently, the MX Frontiers at the One Micron Scale Workshop explored structural biology scientific opportunities made possible through the use of micro-beams, and anticipated technical challenges for developers of MX beamlines at the National Synchrotron Light Source II (NSLS-II). More than 100 attendees participated in the workshop, which included one-and-a-half days of lectures, discussions, and a semi-formal poster session on July 23-24, 2009, at Brookhaven National Laboratory (BNL).

43 PARTICLE ACCELERATORS↗

Protocols and methodologies for acquiring and analyzing critical-current versus longitudinal-strain data in Bi 2 Sr 2 CaCu 2 O 8+x wires

Abstract In the literature on Bi 2 Sr 2 CaCu 2 O 8+ x (Bi-2212) superconducting wires, it is evident that measurement protocols for transport critical-current I c versus longitudinal strain ϵ and definitions of the so-called ‘strain limit’ are generally dissimilar. Yet, values obtained for the ‘strain limit’ are frequently assimilated to being those of the irreversible strain limit ϵ irr , regardless of the I c degradation-criterion used to define it. In effect, ϵ irr should correspond specifically to the I c ( ϵ ) irreversibility onset , where crack formation in Bi-2212 filaments presumably starts. Because I c ( ϵ ) degradation remains progressive over a fairly wide strain range beyond ϵ irr , the different I c degradation-criteria in use do not yield to the same result and, thus, are not equivalent from metrology perspective. Indeed, in studying densified samples of a modern Bi-2212 round wire, we found ϵ irr ≈ 0.4% and ϵ 5% ≈ 0.6% ( ϵ 5% being the strain where I c degrades by 5%). In this paper, we outline and suggest I c ( ϵ )-measurement protocols and data-analysis methodologies in the hope to converge the various approaches taken for studying Bi-2212 strain properties and, thus, remove related result discrepancies. A unified approach would enable more objective data comparisons among laboratories and among different Bi-2212 conductors. It would pave the way for more rigorous studies of effects potentially associated with wire design, powder, heat treatments, and other such parameters on the conductor’s strain properties.

protocols↗

The LArIAT experiment at Fermilab

The LArIAT experiment at Fermilab is part of the International Neutrino program recently approved in the US. LArIAT aims to measure the main features of charged particles interactions in argon in the energy range (0.2 - 2.0 GeV) corresponding to the energy spectrum of the same particles when produced in a neutrino-argon interaction (neutrino energies of few GeV) typical of the short- and long-baseline neutrino beams of the Neutrino Program. Data collected from the 1 st Run are being analyzed for both Physics studies and a technical characterization of the scintillation light collection system. Furthermore, two analysis topics are reported: the method developed for charged pion cross section measurement, based on the specific features of the LArTPC, and the development and test of the LArIAT custom-designed cold front-end electronics for SiPM devices to collect LAr scintillation light.

43 PARTICLE ACCELERATORS↗

Electron-Muon Ranger: Performance in the MICE muon beam

The Muon Ionization Cooling Experiment (MICE) will perform a detailed study of ionization cooling to evaluate the feasibility of the technique. To carry out this program, MICE requires an efficient particle-identification (PID) system to identify muons. The Electron-Muon Ranger (EMR) is a fully-active tracking-calorimeter that forms part of the PID system and tags muons that traverse the cooling channel without decaying. The detector is capable of identifying electrons with an efficiency of 98.6%, providing a purity for the MICE beam that exceeds 99.8%. Lastly, the EMR also proved to be a powerful tool for the reconstruction of muon momenta in the range 100–280 MeV/c.

43 PARTICLE ACCELERATORS↗

Development of a modular test system for the silicon sensor R&D of the ATLAS Upgrade

High Voltage CMOS sensors are a promising technology for tracking detectors in collider experiments. Extensive R&D studies are being carried out by the ATLAS Collaboration for a possible use of HV-CMOS in the High Luminosity LHC upgrade of the Inner Tracker detector. CaRIBOu (Control and Readout Itk BOard) is a modular test system developed to test Silicon based detectors. It currently includes five custom designed boards, a Xilinx ZC706 development board, FELIX (Front-End LInk eXchange) PCIe card and a host computer. A software program has been developed in Python to control the CaRIBOu hardware. CaRIBOu has been used in the testbeam of the HV-CMOS sensor AMS180v4 at CERN. Preliminary results have shown that the test system is very versatile. In conclusion, further development is ongoing to adapt to different sensors, and to make it available to various lab test stands.

43 PARTICLE ACCELERATORS↗

Performance of Michigan sMDT prototype chambers for the HL-LHC ATLAS muon detector upgrade

A new small-diameter Monitored Drift Tube (sMDT) chamber has been developed for the muon spectrometer of the ATLAS experiment to handle the higher collision rates expected at the CERN High Luminosity Large Hadron Collider (HL-LHC). This paper presents measurements of the tracking resolution and hit efficiency of two prototype sMDT chambers constructed at the University of Michigan. Using cosmic-ray muons the sMDT tracking resolution of 103.7 ± 8.1 μm was measured for one chamber and 101.8 ± 7.8 μm for the other, compared with a design resolution of 106 μm. A further tracking resolution improvement to 83.4 ± 7.8 μm was obtained by using new high-gain readout electronics which will be added for HL-LHC. An average tracking efficiency of (98.5 ± 0.2)% was found for both chambers. The methodology used to determine the detector tracking resolution and efficiency, including reconstruction of sMDT data and a Geant4 simulation of the test chamber, is presented in detail.

43 PARTICLE ACCELERATORS↗