Department of Transportation PHMSA Aerosol Spray Project: Phase-0
This report discusses the work conducted at Sandia National Laboratories during the preliminary phase (Phase-0) of the Department of Transportation (DOT) Pipeline and Hazardous Materials Safety Administration (PHMSA) project tasked to better understand what happens to a high-pressure liquid canister or vessel during a fire in which an accidental instantaneous release occurs. Phase 0 had two main objects: (1) to establish a methodology for the high temperature and pressure spray vessel release and (2) to characterize the spray droplet formation. For this test series, diagnostic equipment such as the Malvern Spraytec, high-speed photometric cameras, pencil gauges, and thermocouples were used. Additionally, the effect of surface tension on the particle size distribution was evaluated with 1-liter of distilled water and with the same including the addition of 0.5% soap/water mixture. Results from this effort indicated that the plume formed from the instantaneous release in all conditions primarily included two distinct particle size distributions including 217-312µm and 0.53µm on average. Soapy water formed a higher concentration of smaller mist (0.53µm) than distilled water, potentially due to decreased surface tension with the added surfactant. Though results showed good correlation to certain particle size distributions it is encouraged to conduct additional tests like this with a wider range of liquids with different properties, which could affect the overall particle size distribution when released.