Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Impacts of photovoltaic solar energy on soil carbon: A global systematic review and framework

Globally, solar energy is anticipated to be the primary source of electricity as early as 2050, and the greatest additions in capacity are currently in the form of large, ground-mounted photovoltaic solar energy facilities (GPVs). Growing interest lies in understanding and anticipating opportunities to increase soil carbon sequestration across the footprint and perimeter of both conventional and multi-use GPVs (e.g., ecovoltaics, agrivoltaics, and rangevolatics), especially as operators increasingly deputize as land managers. To date, studies on the relationship between soils and PV solar energy are limited to unique, localized sites. This study employed a systematic review to (i) identify a global corpus of 18 studies on interactions between GPVs and soils, (ii) collect and characterize 113 soil and soil-related experimental variables interacting with GPVs from this corpus, and (iii) synthesize trends among these experimental variables. Next, this study combined data from the systematic review with an iterative, knowledge co-production approach to produce a conceptual model for the study of soil and GPV interactions that applies to multiple installation types, scales, and contexts where GPVs are deployed, and identified research opportunities, threats, and priorities. This study's baseline understanding, conceptual model, and co-produced knowledge confer unique insight into the feasibility of combining soil carbon sequestration with the climate change mitigation potential of PV solar energy.

agrivoltaics↗

PV Degradation - Mounting & Temperature

Several studies have found indications that PV degradation may increase in hotter climates. We show in this paper that degradation does correlate to higher module temperatures, but that these temperatures are significantly affected by the module mounting and. The mechanisms of degradation vary with module technology and quality. Using data from different HIT module installations we were able to extract an activation energy that is consistent with hydrogen passivation layer degradation. In addition, we show that low degradation in hot climates can be achieved for Al-BSF technology if properly installed to reduce heat transfer in order to thermally decouple the modules from the roof. We also found that monofacial and bifacial PERC module degradation is in line with historical degradation rates of Al-BSF.

14 SOLAR ENERGY↗

A Real-Time Degradation Estimation Approach for Batteries in PV and Battery Hybrid Plant Operation

Conventional cyclic degradation assessment for batteries is often limited in its ability to provide real-time degradation information during operation, because the estimation of degradation is commonly performed after a specific evaluation period. Modified methods can provide real-time evaluation but at the cost of high computation complexity. This paper proposes a novel estimation method that addresses these limitations. It efficiently determines the incremental degradation of any two consecutive state-of-charge (SOC) samples during battery operation, thus enabling real-time estimation. To validate the proposed method, measurement data from lithium-ion phosphate (LFP) battery testing was adopted, and the results were compared with the conventional model and the measured capacity. The results demonstrate accuracy over the evaluation period in terms of cumulative degradation, and a reduced computation cost compared with other methods. This approach has benefits in various applications, especially in cases where batteries experience irregular charging and discharging stress cycles such as PV and battery hybrid plants.

Wang, Shumeng↗

Assessing the Performance and Impact of PV Technologies on Storage in Hybrid Renewable Systems

Traditional monofacial photovoltaic (mPV) systems are commonly adopted and well-documented because of their lower upfront costs in comparison to bifacial photovoltaic (bPV) systems. This study investigates how PV technologies impact energy storage in grid-scale hybrid renewable systems, focusing on optimizing and assessing the performance of mPV and bPV technologies integrated with pumped storage hydropower. Using Ludington City, Michigan as a case study and analyzing real-world data such as solar irradiance, ambient temperature, and utility-scale load profiles, the research highlights the operational and economic benefits of bPV systems. The results reveal that bPV systems can pump approximately 10.38% more water annually to the upper reservoir while achieving a lower levelized cost of energy ($0.0578/kWh for bPV vs. $0.0672/kWh for mPV). This study underscores the outstanding potential of bPV systems in enhancing energy storage and management strategies, contributing to a more sustainable and resilient renewable energy future.

13 HYDRO ENERGY↗

Optimized Renewable Energy Integration for EV High-Power Dynamic Wireless Charging Systems

Dynamic wireless charging for electric vehicles is an emerging technology to reduce on-board battery size and extend driving range. Due to its unique characteristic of vehicle-speed-related pulse-like load profile, the high-power dynamic wireless charging system (DWCS) introduces high stress to the utility grid. In this paper, an optimization model for renewable energy integration in the DWCS is proposed to mitigate the grid impact and minimize the operation costs of the whole system. As the load profile of DWCS is related to the traffic volume and various approaching vehicle speeds, the annual average daily traffic data and a stochastic model are used to develop 24-hour load profile of DWCS. To find a tradeoff between grid impact mitigation and operation costs minimization, relationships among power demand from power grid, photovoltaic (PV) capacity, wind energy (WE) capacity and energy storage (ES) capacity are analyzed, and the optimization objective and constraints are developed. Numerical simulation results demonstrate that energy storage integration can greatly mitigate the grid impact of DWCS, and optimal ratio of PV and WE can significantly reduce the operation cost of DWCS.

Zeng, Rong↗

PVEMC: isolating the flavor-dependent EMC effect using parity-violating inelastic scattering in SoLID

In order to better understand the EMC effect, we propose a clean and precise measurement of the flavor dependence of the EMC effect using parity-violating deep inelastic scattering on a 48 Ca target. This measurement will provide an extremely sensitive test for flavor dependence in the modification of nuclear parton distribution functions (PDFs) for neutron-rich nuclei. A measurement of the flavor dependence will provide new and vital information and help to explain nucleon modification at the quark level. In addition to helping understand the origin of the EMC effect, a flavor-dependent nuclear pdf modification could significantly impact a range of processes, including neutrino-nucleus scattering, nuclear Drell-Yan processes, and e-A observables at the Electron-Ion Collider. The parity-violating asymmetry A PV from 48 Ca using an 11 GeV beam at 80 μA will be measured using the SoLID detector, proposed for a series of measurements in Hall A at Jefferson Lab. In 68 days of data taking, we will reach 0.7–1.3% statistical precision for 0.2 < x < 0.7 with 0.6–0.7 systematic uncertainties. Here, the goal is to make the first direct measurement of the flavor dependence of the EMC effect. The precision of the measurement will allow for quantification of the flavor-dependent effects, greatly improving our ability to differentiate between models of the EMC effect and constraining the u- and d-quark contributions in neutron rich nuclei.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Protection of Distribution Circuits with High Penetration of Solar PV: Distance, Learning, and Estimation-Based Methods

The results of DOE Solar Energy Technologies Office project 34233 are presented. The newest version of IEEE Standard 1547 enables photovoltaic inverters to ride through voltage disturbances, improving bulk system reliability, at the expense of removing undervoltage trip as a fast method of de facto fault detection in high PV adoption scenarios. The project explored new methods of fault detection that don't rely on communication systems and could be available quickly, including distance-based schemes, focused directional relays, and two different data-driven schemes. The schemes were evaluated with fast-phasor simulation, electromagnetic transient simulation, and field data collection at partner utilities Chattanooga Electric Power Board and Dominion Energy Virginia. Accomplishments and possible paths forward are summarized.

14 SOLAR ENERGY↗

Spanning the Nexus: Integrated Energy Research on Agriculture & Water Challenges

This presentation will explore the land, food, water, and energy implications of changing energy systems. With an increase in solar development, there are potential conflicts between land use for solar and agricultural. Under the DOE’s InSPIRE project, researchers are gathering data and performing experiments for the co-location of solar development and the agricultural production of crops, pollinator habitat, and grazing. Initial findings from this project highlight mutual benefits for both farmers and the PV installation themselves, all while providing an avenue to reduce land use conflicts. Also, in this presentation, the intersection of water and energy systems will be explored. Energy production requires water and water treatment and transport requires energy. This presentation will highlight past work examining oil and gas water use and detail upcoming water treatment research within the National Water Alliance for Innovation (NAWI).

agriculture↗

A Model for Evaluating the Configuration and Dispatch of PV Plus Battery Power Plants

An open-source model was developed to optimize energy storage operation for photovoltaic- (PV-) plus-battery systems with AC-coupled and DC-coupled configurations. It includes the ability to use forecast energy prices to optimize battery charge and discharge on a rolling time horizon. The model allows for exploration of different configurations, including capital costs, inverter performance, dispatch flexibility, and capturing otherwise clipped energy for the DC-coupled system. The model can run 20 full years of hourly data in approximately two seconds, allowing comparison of a large number of configurations. We applied the model in a test case demonstrating reduced inverter clipping for DC-coupled systems and yielded slightly higher overall value than AC-coupled systems, with an approximately 2 percent increase in internal rate of return or benefit/cost ratio. Our results show that at current estimated prices for lithium-ion battery systems, large-scale PV-plus-battery plants are economically viable under the right conditions, with the configuration playing a role in system flexibility and performance. This model provides the ability for project developers, industry professionals, and researchers to use readily available software to quickly evaluate and design these systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Is 3D/2D Passivation a Secret to Success for Polycrystalline Thin-Film Solar Cells?

Three leading thin-film photovoltaic (PV) technologies - cadmium telluride (CdTe), CuIn1-xGaxSe2 (CIGS), and perovskite solar cells (PSCs) - are all polycrystalline, but otherwise appear to have little in common. A comprehensive examination of these technologies, however, reveals a common theme: the formation of two-dimensional (2D) van der Waals materials at three-dimensional (3D) absorber interfaces and grain boundaries. In CdTe, the 2D compound is CdCl2; in CIGS, it is XInSe2 (X= K, Rb, Cs) with X depending on the heavy-alkali post-deposition treatment used; and in lead halide PSCs, PbI2 forms naturally, but many new, more stable, 2D perovskites have also been incorporated. Generally, these 2D interfacial materials are present not by design, but instead have evolved from their 3D counterparts during standard device processing. Here, new data, together with evidence compiled from the literature, are presented to illustrate both the existence of 3D/2D interfaces in CdTe, CIGS, and PSCs, and their correlation with improved passivation and device performance. This suggests that 3D/2D passivation may be a heretofore unappreciated key to successful polycrystalline thin-film PV. Finally, the desired attributes of successful low-dimensional layers are presented with rational design strategies for next generation polycrystalline solar cells.

3D/2D↗

A Custom High-Throughput Optical Mapping Instrument for Accelerated Stress Testing of PV Module Materials

The performance and integrity of photovoltaic (PV) modules and materials may be assessed through optical characterizations. We have developed a custom optical mapping instrument (OMI) to improve measurement throughput time, facilitate automated measurements, allow for localized specimen examination, obtain spatial information relative to commercial benchtop spectrophotometer instruments, and provide automated data analysis. Both the key components and the methods used to improve the measurements are described. The measurement precision for the OMI is benchmarked for hemispherical transmittance relative to a previous round-robin study for commercial spectrophotometers. In addition to the unique instrument developed in this study, new insights have emerged from the examination of specimens from previous experiments, including: the depletion of the UV absorber is revealed for specimens beyond a certain size after artificial ultraviolet (UV) weathering; an optical degradation by internal haze formation is confirmed following Damp Heat (85 °C/85% relative humidity) testing; the better uniformity of the wear pattern for falling sand abrasion is used to select the DIN 52348 fixture over the ASTM D968 fixture; and the greater local (in the order of millimeters) heterogeneity of surface contamination in the soiling-prone location of Dubai relative to Kuwait. The results of the UV study have already been used to improve the standardized weathering of encapsulants. The example for Damp Heat testing is given to increase awareness of a degradation believed to be ubiquitously occurring in safety and design-type qualification testing of PV modules.

14 SOLAR ENERGY↗

Hierarchical Control of Utility-Scale Solar PV Plants for Mitigation of Generation Variability and Ancillary Service Provision

This paper presents a hierarchical control system to mitigate the variability of solar photovoltaic (PV) power plant and provide ancillary services to the electric grid without the need for additional non-solar resources. With coordinated management of each inverter in the system, the control system commands the power plant to proactively curtail a small fraction of its instantaneous maximum power potential, which gives the plant enough headroom to ramp up production from the overall power plant, for a service such as regulation reserve. This control system is practical for continuously changing cloud cover conditions in partially cloudy days. A case study from a site in Hawaii with one-second resolution solar irradiance data is used to verify the efficacy of the proposed control system. The proposed control algorithm is subsequently compared with the alternative control technology from the literature, the grouping control algorithm; the results show that the proposed hierarchical control system is over 10 times more effective in reducing generator mileage to support power fluctuations from solar PV power plants.

14 SOLAR ENERGY↗

Transient Weighted Moving-Average Model of Photovoltaic Module Back-Surface Temperature

Accurate modeling of photovoltaic (PV) performance requires the precise calculation of module temperature. Currently, most temperature models rely on steady-state assumptions that do not account for the transient climatic conditions and thermal mass of the module. On the other hand, complex physics-based transient models are computationally expensive and difficult to parameterize. In order to address this, a new approach to transient thermal modeling was developed, in which the steady-state predictions from previous timesteps are weighted and averaged to accurately predict the module temperature at finer time scales. This model is informed by 3-D finite-element analyses, which are used to calculate the effect of wind speed and module unit mass on module temperature. The model, in application, serves as an added filter over existing steady-state models that smooths out erroneous values that are a result of intermittency in solar resource. Validation of this moving-average model has shown that it can improve the overall PV energy performance model accuracy by as much as 0.58% over steady-state models based on mean absolute error improvements and can significantly reduce the variability between the model predictions and measured temperature times series data.

14 SOLAR ENERGY↗

Thermal Reservoir Networks for Modularly Expandable Thermal Microgrids

The Department of Defense (DoD) faces the substantial challenge of cost-effectively retrofitting one to two installations per month, each comprising approximately 1,000 buildings, to improve resilience, reduce energy consumption, and enhance energy supply security. Achieving these objectives requires optimal system selection and effective risk mitigation during system integration. To address this need, we introduce Platform-Based Design (PBD), a structured, hierarchical methodology adapted from other industrial sectors to the domain of energy system retrofits. We demonstrate the effectiveness of PBD through a techno-economic feasibility study comparing geothermal-coupled thermal energy networks (TENs) with conventional energy systems for heating, cooling, and powering 17 buildings at Joint Base Andrews (JBA) in Maryland. Our analysis illustrates that the PBD approach enables rigorous, data-driven, sequential decision making, resulting in a family of Pareto-optimal systems, among which the TEN emerged as the most promising solution. The selected TEN design integrates geothermal borefields, heat recovery heat pumps, photovoltaic (PV) arrays, and battery storage. Compared to the baseline system – gas heating combined with air-source chillers – the proposed TEN reduces annual imported energy by 74% and peak electricity demand by 45%, achieves a levelized cost of energy of $\$0.210$/kWh, and substantially enhances resilience. Life-cycle costs increase by approximately 6%, and initial investment costs are about 2.5 times higher than the baseline. However, if central plant infrastructure, district loops, and utility-scale PV and battery systems are privately funded and operated, the initial investment would fall below the baseline system cost. Critical to achieving these significant performance improvements were detailed nonlinear dynamic simulations coupling geothermal heat transfer, energy system operation, and realistic feedback control logic. These simulations identified essential design modifications and control strategy refinements that substantially reduced energy use, peak demand, and compressor shortcycling, thereby improving durability and reliability—issues that would have been significantly more expensive to resolve during operation. Additionally, the verification step highlighted sensitivities to key design parameters that could reduce initial investment by approximately $\$2$ million and reduce annual life-cycle costs more than $\$300,000$. We recommend adopting the PBD methodology for future feasibility studies and TEN pilot projects to gain valuable operational experience. Furthermore, we recommend that DoD invest in transferring and scaling the PBD methodology to other installations. This entails developing standardized computational frameworks and component libraries as well as training industry in conducting PBD. Such investments would enable rapid, robust, reliable, and cost-effective retrofits, supporting DoD’s ambitious energy system modernization goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heavy Oil Polymer EOR in the Challenging Alaskan Arctic - It Works!

Under co-sponsorship of the US Department of Energy and Hilcorp Alaska LLC the first ever polymer field pilot commenced on 8/28/2018 in the Schrader Bluff heavy oil reservoir at the Milne Point Field on Alaska North Slope (ANS). The primary objective of the pilot is to prove the efficacy of polymer Enhanced Oil Recovery (EOR) to unlock the vast heavy oil resources on ANS. More than two and half years after startup, the polymer injection, supporting laboratory experiments and simulation studies steadily continue. The pilot started injecting hydrolyzed polyacrylamide (HPAM), at a concentration of 1,750 ppm to achieve a target viscosity of 45 cP, into the two horizontal injectors in the flood pattern. Production is monitored in the two horizontal producers. Based on laboratory measurements of polymer viscosity at reservoir conditions, the team decided to reduce polymer concentration to 1,200 ppm since July 2020 in an effort to control injection pressure and optimize polymer utilization. Quality control (QC) on the field ensures uniform polymer solution properties. Representative rock and fluid systems and test conditions are utilized in the corefloods on polymer retention, effect of injection water salinity, polymer loading, and their combinations on oil recovery. A history matched reservoir simulation model for forecasting oil recovery was developed on the basis of all the available field data. Field concerns related to the post-polymer breakthrough impact on flow assurance is addressed via specialized laboratory tests. Notwithstanding early operational disruptions and hydration issues, continuous polymer injection in both injectors has been achieved. To date, 950,000 lbs of polymer or 2 million barrels of polymer solution, equating to 13% of total pore volume (PV), has been placed in the flood pattern, serving as an effective indicator of adequate polymer injectivity. So far, the success of polymer EOR is evident from drastically reduced water cut in the producers, an estimated incremental 1,000 bopd over waterflood, and a favorable polymer utilization of 1.7 lbs/barrel of incremental oil. Polymer breakthrough was observed 26 months after the start of polymer injection. Main observations from corefloods are unusually high polymer retention values in some cases and a positive response to low salinity water. Although the heterogeneity in the flood pattern and exceptionally low water cut pose some challenges, persistent novel and justifiable simulation approaches have resulted in a robust history matched model. Experimental results on produced fluids treatment provide operational guidance for improved oil-water separation and mitigation of heater tube fouling. The ongoing success of the pilot is a key indicator of bringing the team ever closer to meeting the project’s primary objective. The encouraging results of the pilot is one of the drivers that has provided the impetus to apply polymer EOR throughout the Milne Point Field, which would increase oil recovery and extend the economic life of the Trans Alaska Pipeline System. The scientific knowledge, including the many lessons learned from this pilot also has referential value for other potential heavy oil EOR projects throughout the world. The collected data, operational lessons learned, and the overall success of the pilot are summarized in the paper.

None, None↗

Task 12 PV Sustainability - Life Cycle Assessment of Crystalline Silicon Photovoltaic Module Delamination with Hot Knife Technology

The objective of this study is to complete a life cycle assessment (LCA) of a novel technology that separates the crystalline silicon (c-Si) photovoltaic (PV) module front glass from the backsheet using hot knife technology. This is known to be the most challenging step in module recycling, where the choice of delamination approach can determine the process selection for the next steps of the recycling process, the economic value of the recovered materials, and environmental performance. The life cycle inventory (LCI) reported here is based on primary data from the technology manufacturer. Different LCIs are established following the cut-off approach and the end-of-life (EOL) approach. The environmental impacts of the hot knife delamination process are analysed based on six indicators, and the main contributors to delamination efforts are identified. For the EOL approach, the potential environmental benefits from the recovered materials are compared to the environmental impacts caused by the delamination process. The functional unit of this analysis is the delamination of 1 kg of used framed c-Si PV modules at the place of installation.

14 SOLAR ENERGY↗

Side-by-Side Comparison of Subhourly Clipping Models

Over the past several years there have been numerous attempts at quantifying the inherent power clipping of inverters due to subhourly irradiance variability that is not captured in hourly PV performance models. Different models have been proposed to correct for these clipping losses in PV performance estimates, including matrix lookup models, distribution modeling of the PV power performance within a given hour, and machine learning methods. To date, there have been few comprehensive quantitative comparisons of these inverter clipping correction modeling approaches to evaluate the effectiveness of these approaches in predicting the actual behavior of PV system inverter clipping. In this study, we perform such a comparison, evaluating the Allen and Walker correction loss modeling approaches recently implemented in the System Advisor Model (SAM) against clipping losses modeled with 1-minute climate data. These comparisons were performed across a variety of climate locations and inverter loading ratios to thoroughly analyze the effectiveness of these modeling approaches relative to each other. Results from this analysis reveal that both clipping correction approaches improve annual energy accuracy to within 2% of 1-minute modeled energy yield. The two models predict annual clipping loss more accurately than simple hourly power limit clipping, with the Allen method typically being slightly more accurate at typical ILR values and the Walker method often being slightly more accurate at high ILR values The models can improve accuracy over the status quo clipping approach up to 3 percentage points in systems with ILR of 2.0, showing the importance of this modeling factor in energy yield estimates.

accuracy↗

Onsite Energy Techno-Economic Analysis Using REopt

Since 2019, the National Renewable Energy Laboratory (NREL) has collaborated with IEDO's Combined Heat and Power (CHP) Deployment Program and the CHP Technical Assistance Partnerships (TAPs) to expand the capabilities of NREL's publicly available REopt® tool for techno-economic analysis of on-site energy. As a result, capabilities to analyze heating and cooling loads and serve those loads with CHP were added to the REopt tool in 2021. Currently, NREL is using REopt to evaluate the economics and feasibility of deploying distributed energy resources at sites of 3-5 manufacturers. The analysis is based on location, site-specific load data, customized utility bill analysis, and other criteria such as resilience needs and decarbonization targets. The objectives of the current effort are to (1) assist manufacturers with analyzing on-site energy options, including CHP, solar photovoltaics (PV), wind, and battery storage, (2) validate the capabilities and use of REopt to provide technical assistance to manufacturers, and (3) publish case studies showcasing the engagement, key takeaways, and lessons learned. Future work is expected to include additional REopt capabilities for evaluating other technologies to reduce scope 1 emissions, such as electrifying process heating loads, using carbon-free fuels, and other clean heat strategies.

ENERGY PLANNING, POLICY, AND ECONOMY↗