Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA CONFINEMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Extreme ultraviolet spectroscopy and modeling of Cu on the SSPX Spheromak and laser plasma 'Sparky'

Impurities play a critical role in magnetic fusion research. In large quantities, impurities can cool and dilute plasma creating problems for achieving ignition and burn; however in smaller amounts the impurities could provide valuable information about several plasma parameters through the use of spectroscopy. Many impurity ions radiate within the extreme ultraviolet (EUV) range. Here, we report on spectra from the silver flat field spectrometer, which was implemented at the Sustained Spheromak Physics experiment (SSPX) to monitor ion impurity emissions. The chamber within the SSPX was made of Cu, which makes M-shell Cu a prominent impurity signature. The Spect3D spectral analysis code was utilized to identify spectral features in the range of 115-315 A and to more fully understand the plasma conditions. A second set of experiments was carried out on the compact laser-plasma x-ray/EUV facility 'Sparky' at UNR, with Cu flat targets used. The EUV spectra were recorded between 40-300 A and compared with results from SSPX.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heavy ion beam probe advances from the first installation of the diagnostic on an RFP (invited)

Heavy ion beam probes have been installed on a variety of toroidal devices, but the first and only application on a reversed field pinch is the diagnostic on the Madison Symmetric Torus. Simultaneous measurements of spatially localized equilibrium potential and fluctuations of density and potential, previously inaccessible in the core of the reversed field pinch (RFP), are now attainable. These measurements reflect the unique strength of the heavy ion beam probe (HIBP) diagnostic. They will help determine the characteristics and evolution of electrostatic fluctuations and their role in transport, and determine the relation of the interior electric field and flows. Many aspects of the RFP present original challenges to HIBP operation and inference of plasma quantities. The magnetic field contributes to a number of the issues: the comparable magnitudes of the toroidal and poloidal fields and edge reversal result in highly three-dimensional beam trajectories; partial generation of the magnetic field by plasma current cause it and hence the beam trajectories to vary with time; and temporal topology and amplitude changes are common. Associated complications include strong ultraviolet radiation and elevated particle losses that can alter functionality of the electrostatic systems and generate noise on the detectors. These complexities have necessitated the development of new operation and data analysis techniques: the implementation of primary and secondary beamlines, adoption of alternative beam steering methods, development of higher precision electrostatic system models, refinement of trajectory calculations and sample volume modeling, establishment of stray particle and noise reduction methods, and formulation of alternative data analysis techniques. These innovative methods and the knowledge gained with this system are likely to translate to future HIBP operation on large scale stellarators and tokamaks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Near midplane scintillator-based fast ion loss detector on DIII-D

A new scintillator-based fast-ion loss detector (FILD) installed near the outer midplane of the plasma has been commissioned on DIII-D. This detector successfully measures coherent fast ion losses produced by fast-ion driven instabilities ({<=}500 kHz). Combined with the first FILD at {approx}45 Degree-Sign below the outer midplane [R. K. Fisher, et al., Rev. Sci. Instrum. 81, 10D307 (2010)], the two-detector system measures poloidal variation of losses. The phase space sensitivity of the new detector (gyroradius r{sub L}{approx}[1.5-8] cm and pitch angle {alpha}{approx}[35 Degree-Sign -85 Degree-Sign ]) is calibrated using neutral beam first orbit loss measurements. Since fast ion losses are localized poloidally, having two FILDs at different poloidal locations allows for the study of losses over a wider range of plasma shapes and types of loss orbits.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling of the ITER-like wide-angle infrared thermography view of JET

Infrared (IR) thermography systems are mandatory to ensure safe plasma operation in fusion devices. However, IR measurements are made much more complicated in metallic environment because of the spurious contributions of the reflected fluxes. This paper presents a full predictive photonic simulation able to assess accurately the surface temperature measurement with classical IR thermography from a given plasma scenario and by taking into account the optical properties of PFCs materials. This simulation has been carried out the ITER-like wide angle infrared camera view of JET in comparing with experimental data. The consequences and the effects of the low emissivity and the bidirectional reflectivity distribution function used in the model for the metallic PFCs on the contribution of the reflected flux in the analysis are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-fast charge exchange spectroscopy for turbulent ion temperature fluctuation measurements on the DIII-D tokamak (invited)

A novel two-channel, high throughput, high efficiency spectrometer system has been developed to measure impurity ion temperature and toroidal velocity fluctuations associated with long-wavelength turbulence and other plasma instabilities. The spectrometer observes the emission of the n= 8-7 hydrogenic transition of C{sup +5} ions ({lambda}{sub air}= 529.06 nm) resulting from charge exchange reactions between deuterium heating beams and intrinsic carbon. Novel features include a large, prism-coupled high-dispersion, volume-phase-holographic transmission grating and high-quantum efficiency, high-gain, low-noise avalanche photodiode detectors that sample emission at 1 MHz. This new diagnostic offers an order-of-magnitude increase in sensitivity compared to earlier ion thermal turbulence measurements. Increased sensitivity is crucial for obtaining enough photon statistics from plasmas with much less impurity content. The irreducible noise floor set by photon statistics sets the ultimate sensitivity to plasma fluctuations. Based on the measured photon flux levels for the entire spectral line, photon noise levels for T(tilde sign){sub i}/T{sub i} and V(tilde sign){sub i}/V{sub i} of {approx}1% are expected, while statistical averaging over long data records enables reduction in the detectable plasma fluctuation levels to values less than that. Broadband ion temperature fluctuations are observed to near 200 kHz in an L-mode discharge. Cross-correlation with the local beam emission spectroscopy measurements demonstrates a strong coupling of the density and temperature fields, and enables the cross-phase measurements between density and ion temperature fluctuations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Density fluctuation measurements using beam emission spectroscopy on Heliotron J

This paper describes the measurement of the density fluctuation using beam emission spectroscopy in Heliotron J, having the non-symmetrical helical-magnetic-axis configuration. In order to optimize the sightlines, the numerical calculations are carried out to estimate the spatial resolution and the observation location. When a tangential neutral beam is used as diagnostic one, suitable sightlines from the newly installed diagnostic port are selected whose spatial resolution {Delta}{rho} is less than {+-}0.07 over the entire plasma region. Modification of the interference filter and the detection systems enables us to measure the radial profile of the density fluctuation. Each of the three coherent modes due to the fast-ion-driven magnetohydrodynamic instabilities has different radial structure of the density fluctuation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prospects for the Thomson scattering system on NSTX-Upgrade

The paper discusses the projected configuration of the Thomson system on the National Spherical Torus Experiment (NSTX-U). In this paper, we discuss the projected configuration of the Thomson system on NSTX-U. More specifically, we determine, through both optical modeling of the collection optics and in-vessel measurements, that the collecting fibers are to be displaced by at most 1 cm toward the imaging plane along the optical axis. Finally, we estimate the performance of the Thomson system in measuring the electron temperature for NSTX-U discharges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrade of the infrared camera diagnostics for the JET ITER-like wall divertor

For the new ITER-like wall at JET, two new infrared diagnostics (KL9B, KL3B) have been installed. These diagnostics can operate between 3.5 and 5 {mu}m and up to sampling frequencies of {approx}20 kHz. KL9B and KL3B image the horizontal and vertical tiles of the divertor. The divertor tiles are tungsten coated carbon fiber composite except the central tile which is bulk tungsten and consists of lamella segments. The thermal emission between lamellae affects the surface temperature measurement and therefore KL9A has been upgraded to achieve a higher spatial resolution (by a factor of 2). A technical description of KL9A, KL9B, and KL3B and cross correlation with a near infrared camera and a two-color pyrometer is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral emission measurements of lithium on the lithium tokamak experiment

There has been a long-standing collaboration between ORNL and PPPL on edge and boundary layer physics. As part of this collaboration, ORNL has a large role in the instrumentation and interpretation of edge physics in the lithium tokamak experiment (LTX). In particular, a charge exchange recombination spectroscopy (CHERS) diagnostic is being designed and undergoing staged testing on LTX. Here we present results of passively measured lithium emission at 5166.89 A in LTX in anticipation of active spectroscopy measurements, which will be enabled by the installation of a neutral beam in 2013. Preliminary measurements are made in transient LTX plasmas with plasma current, I{sub p} < 70 kA, ohmic heating power, P{sub oh}{approx} 0.3 MW and discharge lifetimes of 10-15 ms. Measurements are made with a short focal length spectrometer and optics similar to the CHERS diagnostics on NSTX [R. E. Bell, Rev. Sci. Instrum. 68(2), 1273-1280 (1997)]. These preliminary measurements suggest that even without the neutral beam for active spectroscopy, there is sufficient passive lithium emission to allow for line-of-sight profile measurements of ion temperature, T{sub i}; toroidal velocity and v{sub t}. Results show peak T{sub i} = 70 eV and peak v{sub t} = 45 km/s were reached 10 ms into the discharge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Oblique electron-cyclotron-emission radial and phase detector of rotating magnetic islands applied to alignment and modulation of electron-cyclotron-current-drive for neoclassical tearing mode stabilization

A two channel oblique electron cyclotron emission (ECE) radiometer was installed on the DIII-D tokamak and interfaced to four gyrotrons. Oblique ECE was used to toroidally and radially localize rotating magnetic islands and so assist their electron cyclotron current drive (ECCD) stabilization. In particular, after manipulations operated by the interfacing analogue circuit, the oblique ECE signals directly modulated the current drive in synch with the island rotation and in phase with the island O-point, for a more efficient stabilization. Apart from the different toroidal location, the diagnostic view is identical to the ECCD launch direction, which greatly simplified the real-time use of the signals. In fact, a simple toroidal extrapolation was sufficient to lock the modulation to the O-point phase. This was accomplished by a specially designed phase shifter of nearly flat response over the 1-7 kHz range. Moreover, correlation analysis of two channels slightly above and below the ECCD frequency allowed checking the radial alignment to the island, based on the fact that for satisfactory alignment the two signals are out of phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced production of ECR plasma by using pulse mode microwaves on a large bore ECRIS with permanent magnets

In order to enhance the efficiency of an electron cyclotron resonance (ECR) plasma for a broad and dense ion beam source at low pressure, the magnetic field configuration is constructed by all permanent magnets. By using the pulse mode, we aim at the generation of plasma with parameters that cannot be achieved in the CW mode at microwave frequencies of 11-13GHz, under the constraint of the same average incident microwave powers. It is found that the total beam currents are increased by the pulse mode operation compared with the case of the CW mode. According to probe measurements of the ECR plasma, it is found that the electron density in the pulse mode is larger than that in the CW mode, while the electron temperatures in the pulse mode are lower than that in the CW mode. These results are discussed from the viewpoint of relaxation times obtained on plasma parameters and ECR efficiency. The cause of the beam current increment and operational windows spread due to the pulse mode are also discussed on these parameters suitable to production of molecular/cluster ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hydrogen transport diagnostics by atomic and molecular emission line profiles simultaneously measured for large helical device

We observe the Balmer-{alpha}, -{beta}, and -{gamma} lines of hydrogen atoms and Q branches of the Fulcher-{alpha} band of hydrogen molecules simultaneously with their polarization resolved for large helical device. From the fit including the line splits and the polarization dependences by the Zeeman effect, the emission locations, intensities, and the temperatures of the atoms and molecules are determined. The emission locations of the hydrogen atoms are determined outside but close to the last closed flux surface (LCFS). The results are consistent with a previous work (Phys. Plasmas 12, 042501 (2005)). On the other hand, the emission locations of the molecules are determined to be in the divertor legs, which is farer from those of the atoms. The kinetic energy of the atoms is 1 {approx} 20 eV, while the rotational temperature of molecules is {approx}0.04 eV. Additionally, substantial wings, which originate from high velocity atoms and are not reproduced by the conventional spectral analysis, are observed in the Balmer line profiles. We develop a one-dimensional model to simulate the transport of the atoms and molecules. The model reproduces the differences of the emission locations of the atoms and molecules when their initial temperatures are assumed to be 3 eV and 0.04 eV, respectively. From the model, the wings of the Balmer-{alpha} line is attributed to the high velocity atoms exist deep inside the LCFS, which are generated by the charge exchange collisions with hot protons there.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the formation of m = 1, n = 1 density snakes

The m/n = 1/1 helical ion density 'snake' located near the q = 1 magnetic surface in a toroidal, magnetically confined plasma arises naturally in resistive MHD, when the plasma density evolves separately from pressure. Nonlinear numerical simulations show that a helical density perturbation applied around q = 1 can form a quasi-steady state over q Greater-Than-Or-Equivalent-To 1 with T(tilde sign) of opposite average sign to n. Two principal outcomes depend on the magnitude of n/n and the underlying stability of the 1/1 internal kink mode. For a small q<1 central region, a moderate helical density drives a new, slowly growing type of nonlinear 1/1 internal kink inside q<1, with small n and {nabla}p(tilde sign) Asymptotically-Equal-To {nabla}(nT(tilde sign)). The hot kink core moves away from, or perpendicular to, the high density region near q Asymptotically-Equal-To 1, preserving the snake density during a sawtooth crash. The mode resembles the early stage of heavy-impurity-ion snakes in ohmic discharges, including recent observations in Alcator C-Mod. For a larger, more unstable q<1 region, the helical density perturbation drives a conventional 1/1 kink where n aligns with T(tilde sign), leading to a rapid sawtooth crash. The crash redistributes the density to a localized helical concentration inside q Less-Than-Or-Equivalent-To 1, similar to experimentally observed snakes that are initiated by a sawtooth crash.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Studies of the fast ion energy spectra in TJ-II

The dynamics of the neutral beam injection fast ions in the TJ-II stellarator is studied in this paper from both the theoretical and experimental points of view. The code Integrator of Stochastic Differential Equations for Plasmas (ISDEP) is used to estimate the fast ion distribution function in 3D:1D in real space and 2D in velocity space, considering the 3D structure of TJ-II, the electrostatic potential, non turbulent collisional transport, and charge exchange losses. The results of ISDEP are compared with the experimental data from the compact neutral particle analyzer, which measures the outgoing neutral flux spectra in the energy range E Element-Of (1-45) keV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ideal hydrodynamic scaling relations for a stagnated imploding spherical plasma liner formed by an array of merging plasma jets

This work presents scaling relations for the peak thermal pressure and stagnation time (over which peak pressure is sustained) for an imploding spherical plasma liner formed by an array of merging plasma jets. Results were derived from three-dimensional (3D) ideal hydrodynamic simulation results obtained using the smoothed particle hydrodynamics code SPHC. The 3D results were compared to equivalent one-dimensional (1D) simulation results. It is found that peak thermal pressure scales linearly with the number of jets and initial jet density and Mach number, quadratically with initial jet radius and velocity, and inversely with the initial jet length and the square of the chamber wall radius. The stagnation time scales approximately as the initial jet length divided by the initial jet velocity. Differences between the 3D and 1D results are attributed to the inclusion of thermal transport, ionization, and perfect symmetry in the 1D simulations. A subset of the results reported here formed the initial design basis for the Plasma Liner Experiment [S. C. Hsu et al., Phys. Plasmas 19, 123514 (2012)].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Verification of electromagnetic fluid-kinetic hybrid electron model in global gyrokinetic particle simulation

The fluid-kinetic hybrid electron model is verified in global gyrokinetic particle simulation of linear electromagnetic drift-Alfvenic instabilities in tokamak. In particular, we have recovered the {beta}-stabilization of the ion temperature gradient mode, transition to collisionless trapped electron mode, and the onset of kinetic ballooning mode as {beta}{sub e} (ratio of electron kinetic pressure to magnetic pressure) increases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stability of compressible reduced magnetohydrodynamic equilibria-Analogy with magnetorotational instability

Stability analyses for equilibria of the compressible reduced magnetohydrodynamics (CRMHD) model are carried out by means of the Energy-Casimir (EC) method. Stability results are compared with those obtained for ideal magnetohydrodynamics (MHD) from the classical {delta}W criterion. An identification of the terms in the second variation of the free energy functional for CRMHD with those of {delta}W is made: two destabilizing effects present for CRMHD turn out to correspond to the kink and interchange instabilities in usual MHD, while the stabilizing roles of field line bending and compressibility are also identified in the reduced model. Also, using the EC method, stability conditions in the presence of toroidal flow are obtained. A formal analogy between CRMHD and a reduced incompressible model for magnetized rotating disks, due to Julien and Knobloch [EAS Pub. Series, 21, 81 (2006)], is discovered. In light of this analogy, energy stability analysis shows that the condition for magnetorotational instability (MRI) for the latter model corresponds to the condition for interchange instability in CRMHD, with the Coriolis term and shear velocity playing the roles of the curvature term and pressure gradient, respectively. Using the EC method, stability conditions for the rotating disk model, for a large class of equilibria with possible non-uniform magnetic fields, are obtained. In particular, this shows it is possible for the MRI system to undergo, in addition to the MRI, another instability that is analogous to the kink instability. For vanishing magnetic field, the Rayleigh hydrodynamical stability condition is recovered.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Non-linear modulation of short wavelength compressional Alfven eigenmodes

Most Alfvenic activity in the frequency range between toroidal Alfven eigenmodes and roughly one half of the ion cyclotron frequency on National Spherical Torus eXperiment [Ono et al., Nucl. Fusion 40, 557 (2000)], that is, approximately 0.3 MHz up to Almost-Equal-To 1.2 MHz, are modes propagating counter to the neutral beam ions. These have been modeled as Compressional and Global Alfven Eigenmodes (CAE and GAE) and are excited through a Doppler-shifted cyclotron resonance with the beam ions. There is also a class of co-propagating modes at higher frequency than the counter-propagating CAE and GAE. These modes have been identified as CAE, and are seen mostly in the company of a low frequency, n = 1 kink-like mode. In this paper, we present measurements of the spectrum of these high frequency CAE (hfCAE) and their mode structure. We compare those measurements to a simple model of CAE and present a predator-prey type model of the curious non-linear coupling of the hfCAE and the low frequency kink-like mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗