Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Operating systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Three-Stage Production Cost Modeling Approach for Evaluating the Benefits of Intra-Hour Scheduling Between Balancing Authorities

This paper introduces a production cost modeling approach for evaluating the benefits of intra-hour scheduling among Balancing Authorities (BAs). System operation is modeled in a three-stage sequential manner: day ahead (DA)-hour ahead (HA) real time (RT). In addition to contingency reserve, each BA will need to carry out 'up' and 'down' load following and regulation reserve capacity requirements in the DA and HA time frames. In the RT simulation, only contingency and regulation reserves are carried out as load following is deployed. To model current RT operation with hourly schedules, a new constraint was introduced to force each BA net exchange schedule deviation from HA schedules to be within North American Electric Reliability Corporation (NERC) area control error (ACE) limits. Case studies that investigate the benefits of moving from hourly exchange schedules between Western Electricity Coordinating Council (WECC) BAs into 10-minute exchange schedules under two different levels of wind and solar penetration (11% and 33%) are presented.

17 WIND ENERGY↗

Capacity Markets for Transactive Energy Systems

Capacity markets provide important incentives for resource adequacy in electricity markets and may become more important for providing sufficient revenue and generation capacity with changes to energy market prices driven by increasing levels of zero marginal cost resources. However, current capacity market designs also have important shortfalls that may limit the benefits they can provide to the future grid. Current capacity markets are primarily designed for participation from conventional thermal generators, but markets are evolving with increasing levels of variable renewable energy resources. However, further reforms may be necessary to enable more participation from DERs and demand-side resources. To understand the benefits and shortfalls of current capacity market design, we review the historical reasons electricity markets have needed capacity markets or capacity payments for resource adequacy, and how current capacity market designs may create challenges for incorporating increasing levels of DERs and demand-side resources. We then consider how transactive systems, which allow the coordination of bids and offers for DERs and demand-side resources through a market interaction approach, administered by a Distribution System Operator (DSO), can address traditional resource adequacy problems due to inelastic consumer demand. We also consider the need for a DSO-level capacity market in helping to meet resource adequacy, reliability, and other electricity market objectives. We find that because the missing money in electricity markets is largely driven by incentives to meet resource adequacy goals, and the bulk grid would always supply power to the DSO, that resource adequacy is unlikely to be a determining factor in the need for a DSO-level capacity market. Many current reliability problems could also be addressed by the incorporation of more flexible demand enabled with transactive energy systems. However, other DSO objectives, including resilience, reactive power, voltage control, environmental policies, and energy equity could lead to specific challenges that could be aided by a DSO-level capacity market. We consider the possibility of a DSO-level capacity market in addressing these challenges as well as its potential role in coordinating with the Independent System Operator (ISO) who operates the wholesale market. We conclude with suggestions for future research, including the need to develop analytical models of DSO-level capacity market designs to address these potential objectives and examine their implications for DSOs and consumers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimizing Short-Term Operation of a FIRES-like Industrial Heat Supply Thermal Energy Storage System

The Firebrick Resistance-heated Energy-storage System (FIRES) is under development at MIT for two applications: (1) integration with the Nuclear Air-Brayton Combined Cycle (NACC), a high-performance power conversion system (PCS) that may be used with high- temperature advanced reactors; and (2) industrial heat supply. This paper describes some key features of FIRES and equivalent systems configured for industrial heat supply and presents an assessment of the revenue achievable by a system operating under the conditions expected for early demonstration FIRES installations. The greatest technical challenge of the 21. century is likely to be the effort to minimize the damage caused by global climate change. This effort will require massive reductions in greenhouse gas (GHG) emissions throughout our economy and a transition to an electric power system driven entirely by very-low-carbon generators. Many investigators agree that this will require a substantial increase in electricity generation and in the use of nuclear power, and there is growing awareness that this will also require new technologies and systems for managing and storing energy and matching intermittent supply of renewable resources with electricity demand. Thermal energy storage systems (TESS) will, in some applications, be much more cost effective than the more popular and widely discussed battery electric storage systems and may provide unique capabilities. The Firebrick Resistance-heated Energy-storage System (FIRES) is under development at MIT for two applications: (1) integration with the Nuclear Air-Brayton Combined Cycle (NACC), a high-performance power conversion system (PCS) that may be used with high-temperature advanced reactors like the Fluoride-salt-cooled High-temperature Reactor (FHR), molten salt reactor (MSR) and sodium-cooled fast reactors (SFR); and (2) industrial heat supply. FIRES installations include a stack of refractory firebrick with imbedded electric heaters and airflow channels, a compressor or air blower, and a duct system to connect the firebrick with the heat demand (turbine or industrial customer). Analysis of the FIRES design space has shown that the concept is suitable for a wide range of peak operating temperatures (from about 200 deg.C up to at least 1800 deg. C) and pressures (from ambient to at least 20 atmospheres) and offers very high energy density (up to 1 MWh per cubic meter of firebrick for high temperature systems) at very low cost (as low as $5/kWh). These results favor early demonstration of FIRES. If the cost target of $5/kWh for FIRES systems were achieved, even the lowest expected operating income calculated here could cover the capital cost of a 10 MWh system in a single year. If the FIRES system were assumed to operate for at least 10 years, this level of operating income could readily recover a capital investment up to $50/kWh, which is simultaneously much cheaper than the costs expected for near-future battery systems (in excess of $200/kWh) and much more expensive than the small, low temperature firebrick systems already available for domestic heating. This provides a large margin for unexpected development costs and other uncertainties. FIRES would set a minimum price of electricity near that of natural gas-improving nuclear, wind, and solar economics while reducing greenhouse gas emissions from the industrial sector. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

WM26 Paper Multi-Robot Collaboration for Hazardous Environments

Hazardous nuclear and industrial facilities are rarely designed for robots. Work in these domains demand precise manipulation and robust mobility in cluttered, constrained spaces where off-the-shelf platforms struggle and “one-size-fits-all” machines become costly and complex. Idaho National Laboratory (INL) is developing an autonomous, multi-robot inspection system that coordinates task-specific platforms rather than relying on a single omni-tool robot. An electric truck serves as a power and compute hub for a custom manipulator co-developed with Florida International University (FIU), a commercial mini crawler, a pan–tilt–zoom camera, and a Nexxis Argus LiDAR mapping system. Working in concert, these robots generate spatial, radiation, and temperature maps of the pit environments at the Hanford Waste Tank Farms. These systems will capture visual records and environmental telemetry to allow for analysis post inspection. The system architecture uses Robot Operating System 2 (ROS 2) for publish/subscribe integration, NVIDIA Isaac Sim and Unity for simulation and visualization, and algorithms such as NVBlox to fuse data into unified 3D overlays. This robot-agnostic approach reduces operator burden by enabling autonomy across heterogeneous platforms and lets each robot be used where it is strongest. Having autonomous functions means operators don’t have to fully control multiple different components. The ease of use could allow for more widespread adoption of advanced robotics at waste management sites that see continued use. By coordinating simpler, purpose-built mechanisms, the approach lowers design and manufacturing complexity, reduces capital risk in contaminated settings, and improves controllability for complex inspection and manipulation tasks. We present the architecture, early results, and lessons learned from building and deploying this coordinated multi-robot system, with the goal of accelerating safe, cost-effective adoption of advanced robotics at waste-management sites.

42 - ENGINEERING↗

Purity monitoring for ProtoDUNE-SP

The Deep Underground Neutrino Experiment is a next-generation long-baseline neutrino oscillation experiment based on liquid argon time projection chamber technology. DUNE-s single-phase prototype ProtoDUNE-SP at CERN finished its two-year Phase-1 running in July 2021, successfully collected test-beam and cosmic ray data. A key aspect of LArTPC calibration is the lifetime of drift electrons. A purity monitor is a miniature TPC measuring the lifetime of electrons generated from the photocathode via the photoelectric effect. It enables continuous monitoring of the detector status, especially when filling the cryostat and when liquid argon recirculation systems operate. The purity monitoring system in ProtoDUNE-SP Phase-1 monitored liquid argon purity throughout its entire lifetime. It is essential to the experiment’s successful commissioning, operation, and data taking. This poster discusses the design, implementation, and results of purity monitors and plans.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an Integrated Distribution Management System

This final report details the components, functionality, costs, schedule and benefits of developing an Integrated Distribution Management System (IDMS) for power distribution system operation. The Distribution Automation (DA) and Supervisory Control and Data Acquisition (SCADA) systems used by electric power companies to manage the distribution of electric power to retail energy consumers are vital components of the Nation’s critical infrastructure. Providing electricity is an essential public service and a disruption in that service, if not quickly restored, could threaten the public safety and the Nation’s economic security. Our Nation’s economic prosperity and quality of life have long depended on the essential services that utilities provide; therefore, it is necessary to ensure that electric utilities are able to conduct their operations safely and efficiently. A fully integrated technology of applications is needed to link various remote sensing, communications and control devices with other information tools that help guide Power Distribution Operations personnel. A fully implemented IDMS will provide this, a seamlessly integrated set of applications to raise electric system operating intelligence. IDMS will enhance DA and SCADA through integration of applications such as Geographic Information Systems, Outage Management Systems, Switching Management and Analysis, Operator Training Simulator, and other Advanced Applications, including unbalanced load flow and fault isolation/service restoration. These apps are capable of utilizing and obtaining information from appropriately installed DER, and by integrating disparate systems, the Distribution Operators will benefit from advanced capabilities when analyzing, controlling and operating the electric system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nuclear-Renewable-Storage Systems: Enhancing Planning and Operations of Integrated Energy Systems

Nuclear-renewable-storage integrated energy systems (IES) are multi-carrier energy systems that include not only electricity but also other forms of demands. Because individual IES components must observe their thermo-physical limits, including ramp rates, start-up, and shut-down time, we formulate operations of the IES as an optimization model by minimizing the total operations costs subject to physical limits of all constituent components. In addition, we develop a data-driven approach to improve the computational performance of the economic dispatch model by using reinforcement learning, where an agent is rewarded by meeting demands and penalized otherwise when shifting to the next state.

25 ENERGY STORAGE↗

Optimal Power Flow for Distribution Systems under Uncertain Forecasts

The paper focuses on distribution systems featuring renewable energy sources and energy storage devices, and develops an optimal power flow (OPF) approach to optimize the system operation in spite of forecasting errors. The proposed method builds on a chance-constrained multi-period AC OPF formulation, where probabilistic constraints are utilized to enforce voltage regulation with a prescribed probability. To enable a computationally affordable solution approach, a convex reformulation of the OPF task is obtained by resorting to i) pertinent linear approximations of the power flow equations, and ii) convex approximations of the chance constraints. Particularly, the approximate chance constraints provide conservative bounds that hold for arbitrary distributions of the forecasting errors. An adaptive optimization strategy is then obtained by embedding the proposed OPF task into a model predictive control framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reliability Lessons Learned From GPU Experience With The Titan Supercomputer at Oak Ridge Leadership Computing Facility

The high computational capability of graphics processing units (GPUs) is enabling and driving the scientific discovery process at large-scale. The world’s second fastest supercomputer for open science, Titan, has more than 18,000 GPUs that computational scientists use to perform scientific simu- lations and data analysis. Understanding of GPU reliability characteristics, however, is still in its nascent stage since GPUs have only recently been deployed at large-scale. This paper presents a detailed study of GPU errors and their impact on system operations and applications, describing experiences with the 18,688 GPUs on the Titan supercom- puter as well as lessons learned in the process of efficient operation of GPUs at scale. These experiences are helpful to HPC sites which already have large-scale GPU clusters or plan to deploy GPUs in the future.

Tiwari, Devesh↗

Baseline and target values for regional and point PV power forecasts: Toward improved solar forecasting

Accurate solar photovoltaic (PV) power forecasting allows utilities to reliably utilize solar resources on their systems. However, to truly measure the improvements that any new solar forecasting methods provide, it is important to develop a methodology for determining baseline and target values for the accuracy of solar forecasting at different spatial and temporal scales. This paper aims at developing a framework to derive baseline and target values for a suite of generally applicable, value-based, and custom-designed solar forecasting metrics. The work was informed by close collaboration with utility and independent system operator partners. The baseline values are established based on state-of-the-art numerical weather prediction models and persistence models in combination with a radiative transfer model. The target values are determined based on the reduction in the amount of reserves that must be held to accommodate the uncertainty of PV power output. The proposed reserve-based methodology is a reasonable and practical approach that can be used to assess the economic benefits gained from improvements in accuracy of solar forecasting. Lastly, the financial baseline and targets can be translated back to forecasting accuracy metrics and requirements, which will guide research on solar forecasting improvements toward the areas that are most beneficial to power systems operations.

14 SOLAR ENERGY↗

Scalable Memory Registration for High-Performance Networks Using Helper Threads

Remote DMA (RDMA) enables high performance networks to reduce data copying between an application and the operating system (OS). However RDMA operations in some high performance networks require communication memory explicitly registered with the network adapter and pinned by the OS. Memory registration and pinning limits the flexibility of the memory system and reduces the amount of memory that user processes can allocate. These issues become more significant on multicore platforms, since registered memory demand grows linearly with the number of processor cores. In this paper we propose a new memory registration/deregistration strategy to reduce registered memory on multicore architectures for HPC applications. We hide the cost of dynamic memory management by offloading all dynamic memory registration and deregistration requests to a dedicated memory management helper thread. We investigate design policies and performance implications of the helper thread approach. We evaluate our framework with the NAS parallel benchmarks, for which our registration scheme significantly reduces the registered memory (23.62% on average and up to 49.39%) and avoids memory registration/deregistration costs for reused communication memory. We show that our system enables the execution of problem sizes that could not complete under existing memory registration strategies.

99 GENERAL AND MISCELLANEOUS↗

Estimating the Maximum Potential Revenue for Grid Connected Electricity Storage: Arbitrage and Regulation

The valuation of an electricity storage device is based on the expected future cash flow generated by the device. Two potential sources of income for an electricity storage system are energy arbitrage and participation in the frequency regulation market. Energy arbitrage refers to purchasing (storing) energy when electricity prices are low, and selling (discharging) energy when electricity prices are high. Frequency regulation is an ancillary service geared towards maintaining system frequency, and is typically procured by the independent system operator in some type of market. This paper outlines the calculations required to estimate the maximum potential revenue from participating in these two activities. First, a mathematical model is presented for the state of charge as a function of the storage device parameters and the quantities of electricity purchased/sold as well as the quantities offered into the regulation market. Using this mathematical model, we present a linear programming optimization approach to calculating the maximum potential revenue from an electricity storage device. The calculation of the maximum potential revenue is critical in developing an upper bound on the value of storage, as a benchmark for evaluating potential trading strategies, and a tool for capital finance risk assessment. Then, we use historical California Independent System Operator (CAISO) data from 2010-2011 to evaluate the maximum potential revenue from the Tehachapi wind energy storage project, an American Recovery and Reinvestment Act of 2009 (ARRA) energy storage demonstration project. We investigate the maximum potential revenue from two different scenarios: arbitrage only and arbitrage combined with the regulation market. Our analysis shows that participation in the regulation market produces four times the revenue compared to arbitrage in the CAISO market using 2010 and 2011 data. Then we evaluate several trading strategies to illustrate how they compare to the maximum potential revenue benchmark. We conclude with a sensitivity analysis with respect to key parameters.

electricity storage↗

Stochastic Look-Ahead Commitment: A Case Study in MISO

This paper introduces the Stochastic Look Ahead Commitment (SLAC) software prototyped and tested for the Midcontinent Independent System Operator (MISO) look ahead commitment process. SLAC can incorporate hundreds of wind, load, and net scheduled interchange (NSI) uncertainty scenarios. It uses a progressive hedging method to solve a novel two-stage stochastic unit commitment. The first stage commitment decisions, made only for those generators whose decision to commit or not in each time period cannot be deferred, can cover the uncertainties within the next three hours. The second stage includes both the dispatch for each of the scenarios and the commitment decisions that can be deferred. Study results on 15 MISO production days show that SLAC may bring economic and reliability benefits under uncertainty.

MATHEMATICS AND COMPUTING↗

DLMP of Competitive Markets in Active Distribution Networks: Models, Solutions, Applications, and Visions

Traditionally, the electric distribution system operates with uniform energy prices across all system nodes. However, as the adoption of distributed energy resources (DERs) propels a shift from passive to active distribution network (ADN) operation, a distribution-level electricity market has been proposed to manage new complexities efficiently. In addition, distribution locational marginal price (DLMP) has been established in the literature as the primary pricing mechanism. The DLMP inherits the LMP concept in the transmission-level wholesale market but incorporates characteristics of the distribution system, such as high $R/X$ ratios and power losses, system imbalance, and voltage regulation needs. The DLMP provides a solution that can be essential for competitive market operation in future distribution systems. This article first provides an overview of the current distribution-level market architectures and their early implementations. Next, the general clearing model, model relaxations, and DLMP formulation are comprehensively reviewed. The state-of-the-art solution methods for distribution market clearing are summarized and categorized into centralized, distributed, and decentralized methods. Then, DLMP applications for the operation and planning of DERs and distribution system operators (DSOs) are discussed in detail. Finally, visions of future research directions and possible barriers and challenges are presented.

42 ENGINEERING↗

Data-driven cyber attack detection and mitigation for decentralized wide-area protection and control in smart grids

Modern power systems have already evolved into complicated cyber physical systems (CPS), often referred to as smart grids, due to the continuous expansion of the electrical infrastructure, the augmentation of the number of heterogeneous system components and players, and the consequential application of a diversity of information and telecommunication technologies to facilitate the Wide Area Monitoring, Protection and Control (WAMPAC) of the day-to-day power system operation. Because of the reliance on cyber technologies, WAMPAC, among other critical functions, is prone to various malicious cyber attacks. Successful cyber attacks, especially those sabotage the operation of Bulk Electric System (BES), can cause great financial losses and social panics. Application of conventional IT security solutions is indispensable, but it often turns out to be insufficient to mitigate sophisticated attacks that deploy zero-day vulnerabilities or social engineering tactics. To further improve the resilience of the operation of smart grids when facing cyber attacks, it is desirable to make the WAMPAC functions per se capable of detecting various anomalies automatically, carrying out adaptive activity adjustments in time and thus staying unimpaired even under attack. Most of the existing research efforts attempt to achieve this by adding novel functional modules, such as model-based anomaly detectors, to the legacy centralized WAMPAC functions. In contrast, this dissertation investigates the application of data-driven algorithms in cyber attack detection and mitigation within a decentralized architecture aiming at improving the situational awareness and self-adaptiveness of WAMPAC. First part of the research focuses on the decentralization of System Integrity Protection Scheme (SIPS) with Multi-Agent System (MAS), within which the data-driven anomaly detection and optimal adaptive load shedding are further explored. An algorithm named as Support Vector Machine embedded Layered Decision Tree (SVMLDT) is proposed for the anomaly detection, which provides satisfactory detection accuracy as well as decision-making interpretability. The adaptive load shedding is carried out by every agent individually with dynamic programming. The load shedding relies on the load profile propagation among peer agents and the attack adaptiveness is accomplished by maintaining the historical mean of load shedding proportion. Load shedding only takes place after the consensus pertaining to the anomaly detection is achieved among all interconnected agents and it serves the purpose of mitigating certain cyber attacks. The attack resilience of the decentralized SIPS is evaluated using IEEE 39 bus model. It is shown that, unlike the traditional centralized SIPS, the proposed solution is able to carry out the remedial actions under most Denial of Service (DoS) attacks. The second part investigates the clustering based anomalous behavior detection and peer-assisted mitigation for power system generation control. To reduce the dimensionality of the data, three metrics are designed to interpret the behavior conformity of generator within the same balancing area. Semi-supervised K-means clustering and a density sensitive clustering algorithm based on Hierarchical DBSCAN (HDBSCAN) are both applied in clustering in the 3D feature space. Aiming to mitigate the cyber attacks targeting the generation control commands, a peer-assisted strategy is proposed. When the control commands from control center is detected as anomalous, i.e. either missing or the payload of which have been manipulated, the generating unit utilizes the peer data to infer and estimate a new generation adjustment value as replacement. Linear regression is utilized to obtain the relation of control values received by different generating units, Moving Target Defense (MTD) is adopted during the peer selection and 1-dimensional clustering is performed with the inferred control values, which are followed by the final control value estimation. The mitigation strategy proposed requires that generating units can communicate with each other in a peer-to-peer manner. Evaluation results suggest the efficacy of the proposed solution in counteracting data availability and data integrity attacks targeting the generation controls. However, the strategy stays effective only if less than half of the generating units are compromised and it is not able to mitigate cyber attacks targeting the measurements involved in the generation control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Using Synchrophasor Status Word as Data Quality Indicator: What to Expect in the Field?

Data quality plays a crucial role in successful applications of synchrophasor data in power system operation and control. This paper presents the results of a data quality analysis of a multi-year field-recorded synchrophasor dataset. The analysis has identified several typical data quality issues encountered in the field data. An examination of the PMU status words included with the dataset has revealed several inconsistent implementations and the lack of correlation between the PMU data quality and the status word, which impacts the usefulness of such information. Our investigation has concluded that the status word alone as found in the recorded field dataset could not be used as a reliable indicator of data quality for field-recorded data. Several recommendations are proposed to improve the usefulness of the PMU status word.

Cheng, Zheyuan↗

A simple way to integrate distributed storage into a wholesale electricity market

Abstract Current plans to decarbonize the electric supply system imply that the generation from wind and solar sources will grow substantially. This growth will increase the uncertainty of system operations due to the inherent variability of these renewable sources, and as a result, more reserve capacity will be required to provide the ramping (flexibility) needed for reliable operations. This paper assumes that all of the increased uncertainty comes from wind farms on the grid, and it shows how distributed storage managed locally by aggregators can provide the ramping needed without introducing a separate market for flexibility. This can be accomplished when the aggregators minimize the expected daily cost of the energy purchased from the grid for their customers by submitting optimal bids into the wholesale market with high and low price thresholds for discharging and charging the storage. This model is illustrated using a stochastic multi-period security constrained optimal power flow together with realistic data for a reduction of the network in the Northeast Power Coordinating Council region of the United States. The results show that the bidding strategy for distributed storage provides ramping to the grid just as effectively as storage managed by a system operator.

Lamadrid, Alberto J.↗

Compact System for Operating and Decommissioned Reactor Used Fuel Management - 17243

Most nuclear power plants in operation today were designed with limited wet storage for their discharged used nuclear fuel (UNF), predicated on the assumption that either recycling or geologic storage would be available within the reactor's lifetime. While that has proven to be the case in some countries such as France with its recycling, it has not for most. In the USA, dry storage of UNF at the plant site at an Independent Spent Fuel Storage Installation (ISFSI) has since the mid-1980s been the primary mode of interim storage so that the plant can off-load its UNF from the pools at the power plants. Initially the space reserved for the ISFSI at a reactor site was based on the assumption that the Department of Energy (DOE) would be transporting that UNF to a geological repository site, such as Yucca Mountain, by 1998. However, due to the delay in the opening of any geological repository the utilities are running out of space on their existing ISFSIs for additional UNF dry storage systems. Since plants prefer to keep their ISFSIs inside the protected area of the plant, options for expanding the ISFSI are becoming limited. At the same time, increasing the capacity of the dry storage systems is also not an option in most cases as the dry storage systems have almost reached their capacity limits with the 37 PWR or 89 BWR fuel assembly canister designs. For plants that have announced plans to shut down, their main priority is to off-load the UNF from the pool to dry storage at an ISFSI so that they can proceed to 'Safe store' or other storage options, and start their decommissioning process as soon as possible. Thus, keeping the size of the ISFSI compact is very important for safety, security and economics. This paper will describe the details of a reduced footprint version of AREVA TN's NUHOMS{sup R} System that addresses the need for maximizing ISFSI capacity. This system not only offers a compact design that stores nearly double the number of UNF assemblies in the same space, it also offers superior radiation protection to the workers and public. In addition, it offers unmatched protection against beyond design basis (BDB) events like the tsunami at Fukushima in Japan, the earthquake at North Anna site, tornadoes and manmade attacks such as the 9/11 attack on the World Trade Center in New York. It also includes significant enhancement for a robust Canister Evolved Safety Program for Aging Management. The utilities in the USA are currently using dry storage systems with canisters of different diameter, different length, and different weights. The fuel assemblies that are stored in these canisters are also different in their fuel types (PWR or BWR),different fuel parameters like burnups, enrichments, and cooling times and different storage orientations in the storage overpacks like horizontal or vertical. The compact version of AREVA TN's NUHOMS{sup R} System offers a 'Universal' Storage Overpack which is designed to accept all these different design dry storage canister available in the industry. As UNF storage continues to drives the industry towards innovations that address the need for consolidated storage, compact ISFSIs and aging management, this new evolution of the AREVA TN NUHOMS{sup R} system offers a significant leap forward in addressing all of these challenges. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗