Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OUTAGES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Synchronization in electric power networks with inherent heterogeneity up to 100% inverter-based renewable generation

The synchronized operation of power generators is the foundation of electric power network stability and a key to the prevention of undesired power outages and blackouts. Here, we derive the conditions that guarantee synchronization in power networks with inherent generator heterogeneity when subjected to small perturbations, and perform a parametric sensitivity analysis to understand synchronization with varied types of generators. As inverter-based resources, which are the primary interfacing technology for many renewable sources of energy, have supplanted synchronous generators in ever growing numbers, the center of attention on associated integration challenges have resided primarily on the role of declining system inertia. Our results instead highlight the critical role of generator damping in achieving a stable state of synchronization. Additionally, we report the feasibility of operating interconnected electric grids with up to 100% power contribution from inverter-based renewable generation technologies. Our study has important implications as it sets the basis for the development of advanced control architectures and grid optimization methods that ensure synchronization and further pave the path towards the decarbonization of the electric power sector.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sustainable urban transformations based on integrated microgrid designs

The impacts of natural hazards on infrastructure, enhanced by climate change, are increasingly more severe emphasizing the necessity of resilient energy grids. Microgrids, tailored energy systems for specific neighbourhoods and districts, play a pivotal role in sustaining energy supply during main grid outages. These solutions not only mitigate economic losses and well-being disruptions against escalating hazards but also enhance city resilience in alignment with Sustainable Development Goal (SDG) 11. However, disregarding socioeconomic factors in defining microgrid boundaries risks perpetuating inequalities and impeding progress towards other SDG 11 targets, including fair democratic participation. Our approach integrates social and technical indicators to bolster urban microgrid planning. Through a case study in a US county, we illustrate how integrated microgrid planning effectively intertwines urban resilience, well-being and equity while promoting sustainable development. This study underscores the importance of integrated microgrid planning for sustainable and resilient urban transformation amid environmental and societal challenges.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wildfire and power grid nexus in a changing climate

Global wildfire events have had increasingly severe impacts in recent years, particularly in the western USA, driven by extreme fire-weather conditions, fuel accumulation and multiple ignition sources. Wildfires sparked by power lines tend to be larger and more destructive, as they often occur during high winds, which accelerate the spread of fires. Moreover, efforts to contain wildfires frequently result in power outages, causing considerable economic disruption. Here, in this Review, we examine wildfire risks related to power-line-induced ignitions, infrastructure damage, climate-induced environmental impacts, grid operational risks, real-time grid management risks, vegetation management risks, and financial and funding risks in the context of a changing climate and their interdependence with power grid infrastructures. We then explore the resilience of power grids under wildfire threats, looking at risk analysis, prediction and mitigation strategies. The Review also shares practical insights and experiences in the USA to inform researchers, policymakers and industry professionals.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stochastic Microgrid Scheduling With Chance‐Constrained Resilience Consideration

Traditionally, it is assumed that microgrids transition seamlessly from grid‐connected operation to islanded mode in the event of sudden main grid outages. In reality, the islanding process, especially unintentional islanding, is rarely seamless. Instead, it is subject to voltage and frequency fluctuations caused by the instantaneous disconnection of the point of common coupling (PCC) switch, variations in loads and renewable generation output and even the protection tripping of distributed energy resources (DERs). To mitigate these fluctuations and facilitate a smooth islanding process, we propose a stochastic microgrid scheduling model that incorporates chance‐constrained resilience measures. Specifically, the resilience measure is defined as the probability of successful islanding (PSI), that is, the probability that a microgrid can mitigate the generation‐demand imbalance caused by the disconnection of the PCC switch, variations in load and renewable generation and DER tripping. This measure is modelled using chance constraints. Unlike existing reliability and resilience indices, which typically neglect the possibility of microgrid/DER failure under extreme events and assume their survival while primarily focussing on reducing impact duration or magnitude, the proposed PSI‐based framework explicitly addresses microgrid and DER survival during the islanding transition. The formulated nonlinear chance constraints are approximated using a multiinterval approach and equivalently represented as a mixed‐integer linear programming (MILP) formulation. Case study results validate the proposed method, showing that the PSI estimation error is reduced to less than 8%, compared to approximately 28% with existing methods. Various sensitivity analyses on the DER tripping rate and PSI settings were performed to validate the robustness of the proposed method. In particular, the necessity of accounting for DER tripping in the PSI calculation was demonstrated.

chance constrained optimization↗

Critical values of cyber parameters in a dynamic microgrid system

An islanded microgrid can be used to serve critcal load as a resiliency source when a severe outage occurs. In an islanded mode, control of a microgrid relies on the communication system significantly. Hence, microgrids are cyberphysical systems and, therefore, the cyber system plays a crucial role in the performance of the cyber-power system. A microgrid control scheme is proposed for power dispatch and regulation based on the droop and proportional-integral (PI) feedback control. The proposed control strategy is validated for transient stability following dynamic events. To evaluate the impact of a networked control system on control performance, a cyber model is developed to represent data acquisition periods and communication delays. An analytical method is proposed to determine the critical values for the data reporting periods and communication delays. The analytical method based on a state space model of a networked control system is applicable for large-scale systems. A 2-dimensional stability region of a microgrid in the space of cyber parameters can be obtained by the proposed method, and the critical values of cyber parameters are determined based on the stability region. Simulation results validate that the design of a microgrid as a cyber-physical system needs to be guided by critical values for the data reporting period and communication delay to prevent system instability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal capacity planning of MG with multi-energy coordinated scheduling under uncertainties considered

Multi-objective optimisation of capacity planning for a grid-connected Microgrid (MG) with multi-energy demands is developed in this study. The optimal multi-energy coordinated scheduling, in which uncertainties of renewable energy generation and electricity demand are described by uncertainty intervals, is considered within the capacity planning model. To solve the capacity planning problem while considering the optimal scheduling with uncertainties, a two-level optimisation approach is proposed by integrating interval mixed integer linear programming for scheduling into the multi-objective particle swarm optimisation for capacity planning. The multi-objective addresses the economic issue by minimising the worst-case optimal annual costs of device investments, operation and maintenance, and pollutant emission treatment, as well as the reliability concern by minimising the worst-case optimal annual costs of energy outage. Several MG cases studies are shown to demonstrate the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Battery and backup generator sizing for a resilient microgrid under stochastic extreme events

Owing to the recent power outages caused by extreme events, installing battery energy storage and backup generators is important to improve resiliency for a grid-tied microgrid. In the design stage, the event occurrence time and duration, which are highly uncertain and cannot be effectively predicted, may affect the needed battery and backup generator capacity but are usually assumed to be pre-determined in utility planning tools. This study investigates the optimal battery and backup generator sizing problem considering the stochastic event occurrence time and duration for the grid-tied microgrid under islanded operation. The reliability requirement is quantified by the mean value of the critical customer interruption time in each stochastic islanding time window (ITW), whose length is the duration and the centre is the occurrence time. The stochastic ITW constraint is then transformed to a probability-weighted expression to derive an equivalent Mixed Integer Linear Programming model. Numerical simulations on a realistic grid-tied PV-based microgrid demonstrate that the total cost is reduced by 11.5% considering the stochastic ITW, compared with the deterministic ITW under the same reliability requirement.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing the distribution grid resilience using cyber-physical oriented islanding strategy

The increasing penetration of distributed generations enables an innovative operation paradigm that allows islanded operation to enhance the resilience of the distribution grid. In this study, a cyber-physical oriented islanding strategy is proposed by coordinating centralised and distributed control to achieve seamless islanding transition and operational flexibility in emergency conditions. A cyber-physical control structure is developed to mitigate various disturbances (e.g. emergencies or fluctuations) according to different operation conditions. Specifically, the distributed fault isolation and seamless islanding transition are coordinated to mitigate the outage caused by unplanned islanding, while a secondary control is proposed to support primary control by reducing the power fluctuations during islanded operation. With a rapid response speed, the local cyber-physical devices are coordinated to accomplish islanding separation by selecting a feasible islanded area even under an unplanned islanding situation. A field test was conducted on a practical distribution network in China, and the results demonstrated the effectiveness and feasibility of the proposed islanding strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-time power management technique for microgrid with flexible boundaries

In order to diminish the impacts brought by high penetration of renewable energy on the reliability of distribution systems, some distribution networks (e.g. Chattanooga electric power board system) have deployed smart switches (SSs) to island some areas to mitigate outage losses. However, due to intermittency and sharply changing rate of renewable energy, it is likely to experience insufficient or excessive power for islanded areas. Therefore, a microgrid controller featured with flexible boundaries is proposed. With proposed microgrid controller, the microgrid can not only shrink or expand its boundaries according to current renewable energy supply, but also disconnect/connect to the main grid with a designated SS. Furthermore, to ensure the microgrid controller could obtain suitable boundaries on the time scale of seconds, a real-time power management technique with alternative generating algorithm is designed to generate all possible alternative boundaries and choose the optimal one, which is scalable to any topology. In addition, in order to maintain state of charge of batteries within a desirable range, anti-overcharge/discharge strategies are designed. Four comprehensive experiments verify that the implementation of the microgrid controllers can realise flexible boundaries and deal with sharply changing rate of renewable generation or load on the time scale of seconds.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal distribution system restoration using PHEVs

Power outages cost billions of dollars every year and jeopardise the lives of hospital patients. Traditionally, power distribution system takes a long time to recover after a major blackout, due to its top-down operation strategy. New technologies in modern distribution systems bring opportunities and challenges to distribution system restoration. As fast response energy resources, plug-in hybrid electric vehicles (PHEVs) can accelerate the load pickup by compensating the imbalance between available generation and distribution system load. This study provides a bottom-up restoration strategy to use PHEVs for reliable load pickup and faster restoration process. The optimisation problem of finding load pickup sequence to maximise restored energy is formulated as a mixed integer linear programming (MILP) problem. Moreover, the coordination between transmission and distribution restoration is developed to efficiently restore the entire system back to normal operating conditions. Simulation results on one 100-feeder test system demonstrate the efficiency of MILP-based restoration strategy and the benefit from PHEVs to restore more energy in given restoration time. The proposed restoration strategy has great potential to facilitate system operators to achieve efficient system restoration plans. It also provides incentives to deploy a large amount of PHEVs to improve system resiliency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal placement of data concentrators for expansion of the smart grid communications network

Evolving power systems with increasing renewables penetration, along with the development of the smart grid, calls for improved communication networks to support these distributed generation sources. Automatic and optimal placement of communication resources within the advanced metering infrastructure is critical to provide a high‐performing, reliable, and resilient power system. Three network design formulations based on mixed‐integer linear and non‐linear programming approaches are proposed to minimise network congestion by optimising residual buffer capacity through the placement of data concentrators and network routeing. Results on a case study show that the proposed models improve network connectivity and robustness, and increase average residual buffer capacity. Maximising average residual capacity alone, however, results in both oversaturated and underutilised nodes, while maximising either minimum residual capacity or total reciprocal residual capacity can yield much‐improved network load allocation. Consideration of connection redundancy improves network reliability further by ensuring quality‐of‐service in the event of an outage. Analysis of multi‐period network expansion shows that the models do not deviate significantly from optimal when used progressively (within 5% deviation), and are effective for utility planners to use for smart grid expansion.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effective restoration strategies of interdependent power system and communication network

The power system is continuously evolving towards a smarter grid by adding intelligent electrical devices that leverage communication technologies to provide visualisation, control and automation. The integration of power system and communication network has brought challenges into the resilience of interdependent networks. Following an outage or blackout, system operators cannot only restore one network while simply ignoring the interconnection with the other network. Effective restoration strategies that involve co‐ordination between power system and communication network have become critical in enhancing the resilience. An optimisation‐based restoration strategy is developed to coordinate the restoration actions between two networks. The problem is modelled as a mixed integer linear programming problem, with the objective of activating every node in both networks with the minimum number of activation/energisation of branches. The developed strategies are tested on the modified IEEE 14‐bus system incorporating communication network. Simulation results demonstrate that the coordinated restoration strategies are effective and critical in the successful recovery of interdependent networks. The developed model could also provide insights in network design and planning to enhance the resilience of interdependent power system and communication network.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantification of storage required for preserving frequency security in wind‐integrated systems

Abstract The penetration of wind power generation into the power grid has been accelerated in recent times due to the aggressive emission targets set by governments and other regulatory authorities. Although wind power has the advantage of being environment‐friendly, wind as a resource is intermittent in nature. In addition, wind power contributes little inertia to the system as most wind turbines are connected to the grid via power electronic converters. These negative aspects of wind power pose serious challenges to the frequency security of power systems as penetration increases. In this work, an approach is proposed where an energy storage system (ESS) is used to mitigate frequency security issues of wind‐integrated systems. ESSs are well equipped to supply virtual inertia to the grid due to their fast‐acting nature, thus replenishing some of the energy storage capability of displaced inertial generation. In this work, a probabilistic approach is proposed to estimate the amount of inertia required by a system to ensure frequency security. Reduction in total system inertia due to the displacement of conventional synchronous generation by wind power generation is considered in this approach, while also taking into account the loss of inertia due to forced outages of conventional units. Monte Carlo simulation is employed for implementing the probabilistic estimation of system inertia. An ESS is then sized appropriately, using the system swing equation, to compensate for the lost inertia. The uncertainty associated with wind energy is modeled into the framework using an autoregressive moving average technique. Effects of increasing the system peak load and changing the wind profile on the expected system inertia are studied to illustrate various factors that might affect system frequency security. The proposed method is validated using the IEEE 39‐bus test system.

17 WIND ENERGY↗

A two-stage service restoration method for electric power distribution systems

Improving the reliability of power distribution systems is critically important for both utilities and customers. This calls for an efficient service restoration module within a distribution management system to support the implementation of self-healing smart grid networks. Although the emerging smart grid technologies, including distributed generators (DGs) and remote-controlled switches, enhance the self-healing capability and allow faster recovery, they still pose additional complexity to the service restoration problem, especially under cold load pickup (CLPU) conditions. Herein, a novel two-stage restoration framework is proposed to generate a restoration solutions with a sequence of control actions. The first stage generates a restoration plan that supports both the traditional service restoration using feeder reconfiguration and the grid-forming DG-assisted intentional islanding methods. The second stage generates an optimal sequence of switching operations to bring the outaged system quickly to the final restored configuration. The problem is formulated as a mixed-integer linear program that incorporates system connectivity, operating constraints, and the CLPU models. It is demonstrated that on using a multi-feeder test case, the proposed framework is effective in utilizing all available resources to quickly restore the service and generate an optimal sequence of switching actions to be used by the operator to reach the desired optimal configuration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The LSBmax algorithm for boosting resilience of electric grids post (N‐2) contingencies

Abstract A computationally improved algorithm is presented to find the best transmission switching (TS) candidate for boosting resilience of electricity grids subject to ( N ‐2) contingencies. Here, resilience is computed as the reduction in load shed after the above‐mentioned ( N‐ ) contingencies. TS is a planned line outage, and past research shows that changing the transmission system's topology changes the power flow and removes post contingency violations. Finding the best TS candidate in a computationally suitable time for effectively boosting resilience is a challenge. The best TS candidate is found using a novel heuristic method by decreasing the search space based on proximity to the bus with the maximum load shedding (LSB). The LSB algorithm is faster than existing algorithms in the literature; and, it is compatible with both the AC and DC optimal power flow formulations. To validate the authors' claims of speedup and accuracy, two metrics are used to analyze the results from the IEEE 39‐bus and 118‐bus systems. Finally, the inherent parallelism of the LSB algorithm is leveraged on a high‐performance computing platform and applied to the large‐scale Polish 2383‐bus test system to validate scalability in both size and speedup in computation time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modelling and analysis of nuclear reactor system coupled with a liquid metal battery

Traditionally, nuclear power plants in the U.S. provide baseload power to the power grid because they have less flexibility for ramping their output power than natural gas peaking plants. However, achieving climate goals to reduce the consumption of fossil‐based natural gas places pressure on nuclear power plants and other power generators to ramp up their power output to balance grid generation with demand. This paper presents the modelling and performance analysis of a nuclear reactor system (NRS) coupled to a liquid‐metal battery (LMB) to improve its dynamic response and enable its black start capability. The NRS and LMB thermal behaviour are modelled in Dymola, while the electrical dynamics of the LMB and power grid are modelled in RTDS‐RSCAD. Both simulation platforms are coupled and share their thermal and electrical data using a Transmission Control Protocol/Internet Protocol (TCP/IP) communication protocol. The dynamic performance of the NRS‐LMB integration is tested on the IEEE 9 bus, which demonstrates its ability to respond and provide frequency and voltage regulation. The black start capability of the NRS‐LMB is also evaluated by simulating a grid outage and using the LMB to supply the auxiliary loads required to bring the NRS back online as soon as possible. The results show that coupling an NRS to an LMB improves the system dynamic performance and enables it to black start after being disconnected from the grid for several days.

25 ENERGY STORAGE↗

OPERATION OF FUSION REACTORS IN ONE ATMOSPHERE OF AIR INSTEAD OF VACUUM SYSTEMS

Engineering design studies of both magnetic and inertial fusion power plants have assumed that the plasma will undergo fusion reactions in a vacuum environment. Operation under vacuum requires an expensive additional major system for the reactor-a vacuum vessel with vacuum pumping, and raises the possibility of sudden unplanned outages if the vacuum containment is breached. It would be desirable in many respects if fusion reactors could be made to operate at one atmosphere with air surrounding the plasma, thus eliminating the requirement of a pressure vessel and vacuum pumping. This would have obvious economic, reliability, and engineering advantages for currently envisaged power plant reactors; it would make possible forms of reactor control not possible under vacuum conditions (i.e. adiabatic compression of the fusion plasma by increasing the pressure of surrounding gas); it would allow reactors used as aircraft engines to operate as turbojets or ramjets in the atmosphere, and it would allow reactors used as fusion rockets to take off from the surface of the earth instead of low earth orbit.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A numerical study of geometry dependent errors in velocity, temperature, and density measurements from single grid planar retarding potential analyzers

Planar retarding potential analyzers (RPAs) have been utilized numerous times on high profile missions such as the Communications/Navigation Outage Forecast System and the Defense Meteorological Satellite Program to measure plasma composition, temperature, density, and the velocity component perpendicular to the plane of the instrument aperture. These instruments use biased grids to approximate ideal biased planes. These grids introduce perturbations in the electric potential distribution inside the instrument and when unaccounted for cause errors in the measured plasma parameters. Traditionally, the grids utilized in RPAs have been made of fine wires woven into a mesh. Previous studies on the errors caused by grids in RPAs have approximated woven grids with a truly flat grid. Using a commercial ion optics software package, errors in inferred parameters caused by both woven and flat grids are examined. A flat grid geometry shows the smallest temperature and density errors, while the double thick flat grid displays minimal errors for velocities over the temperature and velocity range used. Wire thickness along the dominant flow direction is found to be a critical design parameter in regard to errors in all three inferred plasma parameters. The results shown for each case provide valuable design guidelines for future RPA development.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗