Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Motion Tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Online task-space motion control for positioner-coordinated multi-robot manufacturing systems

Incorporating multiple robotic manipulators into large-scale manufacturing systems enhances production efficiency and expands manufacturing capabilities beyond those of single-robot systems. Workpiece positioners in robotic manufacturing have demonstrated significant benefits for process optimization, but coordination strategies for multi-robot systems with shared positioners have received limited attention. This work presents a task-space coordinated trajectory-tracking control framework for multi-robot manufacturing systems, in which robots coordinate their motions within a shared, dynamic workpiece positioning frame. A workpiece positioner actively adjusts the pose of the manufactured component to enable greater operational concurrency and improve overall production efficiency. The proposed motion-coordination scheme employs a distributed and scalable architecture, supporting coordination across heterogeneous multi-robot systems. Two optimization methodologies are introduced to manage kinematic redundancies and maintain continuous, near-optimal operation throughout the manufacturing process. The first strategy exploits a task-space dimensionality reduction to achieve locally optimal configurations by leveraging symmetry-axis rotations of the tool. The second strategy utilizes the workpiece positioner to drive the coordinated robots toward stable and kinematically favorable configurations. For both optimization strategies, multiple objectives are defined to improve key performance metrics, including manipulability, configuration consistency, proximity to mechanical limits, and motion efficiency. Addressing a key limitation of existing coordination approaches, the framework is designed around online setpoint modification, allowing coordinated robots to respond effectively to in-situ process feedback. The proposed control framework is validated using the Robot Operating System (ROS) middleware on a combination of physical and simulated multi-robot system hardware.

Arbogast, Alex [ORNL] (ORCID:0000000154740723)↗

Improved electronic interfaces for AT-cut quartz crystal microbalance sensors under variable damping and parallel capacitance conditions

A new configuration of automatic capacitance compensation (ACC) technique based on an oscillatorlike working interface, which permits the tracking of the series resonant frequency and the monitoring of the motional resistance and the parallel capacitance of a thickness-shear mode quartz crystal microbalance sensor, is introduced. The new configuration permits an easier calibration of the system which, in principle, improves the accuracy. Experimental results are reported with 9 and 10 MHz crystals in liquids with different parallel capacitances which demonstrate the effectiveness of the capacitance compensation. Some frequency deviations from the exact series resonant frequency, measured by an impedance analyzer, are explained by the specific nonideal behavior of the circuit components. A tentative approach is proposed to solve this problem that is also common to previous ACC systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Transient Reactor Test Facility (TREAT)

TREAT operated from 1959-1994, later refurbished & resumed operation in 2017 to support fuel safety testing Zircaloy-clad graphite/fuel blocks comprise core Virtually any power history possible within ~2000 MJ core transient energy capacity From milliseconds to minutes: Pulses, Ramps, LOCA Fuel motion monitoring system “hodoscope” observes fast neutrons emitted from specimens to track fuel relocation in real time Reactor also can be a neutron source to adjacent radiography facility Experiment vehicle does everything else Safety containment, specimen environment, and instrumentation

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimized Hybrid Megavoltage-Kilovoltage Imaging Protocol for Volumetric Prostate Arc Therapy

Purpose: To develop a real-time prostate position monitoring technique for modern arc radiotherapy through novel use of cine-megavoltage (MV) imaging, together with as-needed kilovoltage (kV) imaging. Methods and Materials: We divided the task of monitoring the intrafraction prostate motion into two steps for rotational deliveries: to detect potential target motion beyond a predefined threshold using MV images from different viewing angles by taking advantage of gantry rotation during arc therapy and to verify the displacement and determine whether intervention is needed using fiducial/tumor position information acquired from combined MV-kV imaging (by turning on the kV imager). A Varian Trilogy linear accelerator with an onboard kV imager was used to examine selected typical trajectories using a four-dimensional motion phantom. The performance of the algorithm was evaluated using phantom measurements and computer simulation for 536 Calypso-measured tracks from 17 patients. Results: Fiducial displacement relative to the MV beam was limited to within a range of 3 mm 99.9% of the time with <1 mm accuracy. On average, only {approx}0.5 intervention per arc delivery was needed to achieve this level of accuracy. Compared with other fluoroscopy-based tracking techniques, kV use was significantly reduced to an average of <15 times per arc delivery. Conclusion: By focusing the attention on detecting predefined abnormal motion (i.e., 'failure' detection) and using the inherent mechanism of gantry rotation during arc radiotherapy, the current approach provides high confidence regarding the prostate position in real time without the unwanted overhead of continuous or periodic kV imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Final Report: Non-Visible, Automated Target Acquisition and Tracking

The Roadside Tracker (RST) represents a new approach to radiation portal monitors. It uses a combination of gamma-ray and visible-light imaging to localize gamma-ray radiation sources to individual vehicles in free-flowing, multi-lane traffic. Deployed as two trailers that are parked on either side of the roadway (Fig. 1); the RST scans passing traffic with two large gamma-ray imagers, one mounted in each trailer. The system compensates for vehicle motion through the imager’s fields of view by using automated target acquisition and tracking (TAT) software applied to a stream of video images. Once a vehicle has left the field of view, the radiation image of that vehicle is analyzed for the presence of a source, and if one is found, an alarm is sounded. The gamma-ray image is presented to the operator together with the video image of the traffic stream when the vehicle was approximately closest to the system (Fig. 2). The offending vehicle is identified with a bounding box to distinguish it from other vehicles that might be present at the same time. The system was developed under a previous grant from the Department of Homeland Security’s (DHS’s) Domestic Nuclear Detection Office (DNDO). This report documents work performed with follow-on funding from DNDO to further advance the development of the RST. Specifically, the primary thrust was to extend the performance envelope of the system by replacing the visible-light video cameras used by the TAT software with sensors that would allow operation at night and during inclement weather. In particular, it was desired to allow operation after dark without requiring external lighting. As part of this work, the system software was also upgraded to allow the use of 64-bit computers, the current generation operating system (OS), software development environment (Windows 7 vs. Windows XP, and current Visual Studio.Net), and improved software version controls (GIT vs. Source Safe.) With the upgraded performance allowed by new computers, and the additional memory available in a 64-bit OS, the system was able to handle greater traffic densities, and this also allowed addition of the ability to handle stop-and-go traffic.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Actively triggered 4d cone-beam CT acquisition

Purpose: 4d cone-beam computed tomography (CBCT) scans are usually reconstructed by extracting the motion information from the 2d projections or an external surrogate signal, and binning the individual projections into multiple respiratory phases. In this “after-the-fact” binning approach, however, projections are unevenly distributed over respiratory phases resulting in inefficient utilization of imaging dose. To avoid excess dose in certain respiratory phases, and poor image quality due to a lack of projections in others, the authors have developed a novel 4d CBCT acquisition framework which actively triggers 2d projections based on the forward-predicted position of the tumor.Methods: The forward-prediction of the tumor position was independently established using either (i) an electromagnetic (EM) tracking system based on implanted EM-transponders which act as a surrogate for the tumor position, or (ii) an external motion sensor measuring the chest-wall displacement and correlating this external motion to the phase-shifted diaphragm motion derived from the acquired images. In order to avoid EM-induced artifacts in the imaging detector, the authors devised a simple but effective “Faraday” shielding cage. The authors demonstrated the feasibility of their acquisition strategy by scanning an anthropomorphic lung phantom moving on 1d or 2d sinusoidal trajectories.Results: With both tumor position devices, the authors were able to acquire 4d CBCTs free of motion blurring. For scans based on the EM tracking system, reconstruction artifacts stemming from the presence of the EM-array and the EM-transponders were greatly reduced using newly developed correction algorithms. By tuning the imaging frequency independently for each respiratory phase prior to acquisition, it was possible to harmonize the number of projections over respiratory phases. Depending on the breathing period (3.5 or 5 s) and the gantry rotation time (4 or 5 min), between ∼90 and 145 projections were acquired per respiratory phase resulting in a dose of ∼1.7–2.6 mGy per respiratory phase. Further dose savings and decreases in the scanning time are possible by acquiring only a subset of all respiratory phases, for example, peak-exhale and peak-inhale only scans.Conclusions: This study is the first experimental demonstration of a new 4d CBCT acquisition paradigm in which imaging dose is efficiently utilized by actively triggering only those projections that are desired for the reconstruction process.

61 RADIATION PROTECTION AND DOSIMETRY↗

Large-eddy simulation of heavy particle dispersion in wall-bounded turbulent flows

Capabilities and accuracy issues in Lagrangian tracking of heavy particles in velocity fields obtained from large-eddy simulations (LES) of wall-bounded turbulent flows are reviewed. In particular, it is shown that, if no subgrid scale (SGS) model is added to the particle motion equations, particle preferential concentration and near-wall accumulation are significantly underestimated. Results obtained with SGS modeling for the particle motion equations based on approximate deconvolution are briefly recalled. Then, the error purely due to filtering in particle tracking in LES flow fields is singled out and analyzed. The statistical properties of filtering errors are characterized in turbulent channel flow both from an Eulerian and a Lagrangian viewpoint. Implications for stochastic SGS modeling in particle motion equations are briefly outlined.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Technical Note: A novel leaf sequencing optimization algorithm which considers previous underdose and overdose events for MLC tracking radiotherapy

Purpose: Multileaf collimator (MLC) tracking radiotherapy is complex as the beam pattern needs to be modified due to the planned intensity modulation as well as the real-time target motion. The target motion cannot be planned; therefore, the modified beam pattern differs from the original plan and the MLC sequence needs to be recomputed online. Current MLC tracking algorithms use a greedy heuristic in that they optimize for a given time, but ignore past errors. To overcome this problem, the authors have developed and improved an algorithm that minimizes large underdose and overdose regions. Additionally, previous underdose and overdose events are taken into account to avoid regions with high quantity of dose events. Methods: The authors improved the existing MLC motion control algorithm by introducing a cumulative underdose/overdose map. This map represents the actual projection of the planned tumor shape and logs occurring dose events at each specific regions. These events have an impact on the dose cost calculation and reduce recurrence of dose events at each region. The authors studied the improvement of the new temporal optimization algorithm in terms of the L1-norm minimization of the sum of overdose and underdose compared to not accounting for previous dose events. For evaluation, the authors simulated the delivery of 5 conformal and 14 intensity-modulated radiotherapy (IMRT)-plans with 7 3D patient measured tumor motion traces. Results: Simulations with conformal shapes showed an improvement of L1-norm up to 8.5% after 100 MLC modification steps. Experiments showed comparable improvements with the same type of treatment plans. Conclusions: A novel leaf sequencing optimization algorithm which considers previous dose events for MLC tracking radiotherapy has been developed and investigated. Reductions in underdose/overdose are observed for conformal and IMRT delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

Relationship Between Diseased Lung Tissues on Computed Tomography and Motion of Fiducial Marker Near Lung Cancer

Purpose: For lung cancer patients with poor pulmonary function because of emphysema or fibrosis, it is important to predict the amplitude of internal tumor motion to minimize the irradiation of the functioning lung tissue before undergoing stereotactic body radiotherapy. Methods and Materials: Two board-certified diagnostic radiologists independently assessed the degree of pulmonary emphysema and fibrosis on computed tomography scans in 71 patients with peripheral lung tumors before real-time tumor-tracking radiotherapy. The relationships between the computed tomography findings of the lung parenchyma and the motion of the fiducial marker near the lung tumor were investigated. Of the 71 patients, 30 had normal pulmonary function, and 29 had obstructive pulmonary dysfunction (forced expiratory volume in 1 s/forced vital capacity ratio of <70%), 6 patients had constrictive dysfunction (percentage of vital capacity <80%), and 16 had mixed dysfunction. Results: The upper region was associated with smaller tumor motion, as expected (p = .0004), and the presence of fibrosis (p = .088) and pleural tumor contact (p = .086) were weakly associated with tumor motion. The presence of fibrotic changes in the lung tissue was associated with smaller tumor motion in the upper region (p <.05) but not in the lower region. The findings of emphysema and pulmonary function tests were not associated with tumor motion. Conclusion: Tumors in the upper lung region with fibrotic changes have smaller motion than those in the upper region of the lungs without fibrotic changes. The tumor motion in the lower lung region was not significantly different between patients with and without lung fibrosis. Emphysema was not associated with the amplitude of tumor motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A framework for activity detection in wide-area motion imagery

Wide-area persistent imaging systems are becoming increasingly cost effective and now large areas of the earth can be imaged at relatively high frame rates (1-2 fps). The efficient exploitation of the large geo-spatial-temporal datasets produced by these systems poses significant technical challenges for image and video analysis and data mining. In recent years there has been significant progress made on stabilization, moving object detection and tracking and automated systems now generate hundreds to thousands of vehicle tracks from raw data, with little human intervention. However, the tracking performance at this scale, is unreliable and average track length is much smaller than the average vehicle route. This is a limiting factor for applications which depend heavily on track identity, i.e. tracking vehicles from their points of origin to their final destination. In this paper we propose and investigate a framework for wide-area motion imagery (W AMI) exploitation that minimizes the dependence on track identity. In its current form this framework takes noisy, incomplete moving object detection tracks as input, and produces a small set of activities (e.g. multi-vehicle meetings) as output. The framework can be used to focus and direct human users and additional computation, and suggests a path towards high-level content extraction by learning from the human-in-the-loop.

99 GENERAL AND MISCELLANEOUS↗

SU-E-J-64: Feasibility Study of Surgical Clips for Fiducial Tracking in CyberKnife System

Purpose: To investigate the ability of CyberKnife to track surgical clips used as fiducial markers. Methods: The Octavius 1000SRS detector and solid water (RW3) slab phantom were used with motion platform to evaluate the study. The RW3 slab phantom was set up to measure the dose distribution from coronal plane. It consists of 9 plates and the thickness of each plate is 10mm. Among them, one plate was attached with 3 surgical clips, which are orthogonally positioned on outer region of array. The length of attached clip was represented as 1cm on planning CT. The clip plate was placed on the 1000SRS detector and 3 slabs were stacked up on the plate to build the measuring depth. Below the detector, 5 slabs were set. The two-axis motion platform was programmed with 1D sinusoidal movement (20mm peak-to-peak, 3s period) toward superior/inferior and left/right directions to simulate target motion. During delivery, two clips were extracted by two X-ray imagers, which led to translational error correction only. Synchrony was also used for dynamic tracking. After the irradiation, the measured dose distribution of coronal plane was compared with the planar dose distribution calculated by the CyberKnife treatment planning system (Multiplan) for cross verification. The results were assessed by comparing the absolute Gamma (γ) index. Results: The dose distributions measured by the 1000SRS detector were in good agreements with those calculated by Multiplan. In the dosimetric comparison using γ-function criteria based on the distance-to-agreement of 3mm and the local dose difference of 3%, the passing rate with γ- parameter ≤1 was 91% in coronal plane. Conclusion: The surgical clips can be considered as new fiducials for robotic radiosurgery delivery by considering the target margin with less than 5mm.

60 APPLIED LIFE SCIENCES↗

Autonomous Selective Parts-Based Tracking

Object tracking from videos is still a challenging task due to various changes throughout a video sequence including occlusions, motion blur, scale and other deformation changes. In this paper, we propose a selective parts-based approach, using correlation filters, that makes choices based on a consensus of the parts and global tracking. Moreover, we further enhance our parts-based approach by introducing a segmentation-assisted parts initialization. In addition, we present a genetic algorithm-based method to autonomously select various parameters of the tracking algorithm, as opposed to the common practice of manually tuning those parameters. In contrast to existing part-based methods, the proposed method does not dilute accurate tracking by averaging results over multiple parts at every frame. Instead, we take a selective approach based on the relative weight of the responses across parts. Moreover, we only make location corrections when a part diverges, and rely on these location corrections to maintain an accurate appearance model. In the case of occlusions, which are among the main reasons for using a parts-based approach, our proposed approach consistently achieves the best performance. It is due to the ability to handle occlusion and not dilute decisions with incorrect parts, that our proposed approach enables state-of-the-art performance. The approach we propose was evaluated on videos from three different challenging benchmark datasets. Our approach has resulted in better overall precision and success rates for three different base tracking approaches.

42 ENGINEERING↗

Lifecycle of updrafts and mass flux in isolated deep convection over the Amazon rainforest: insights from cell tracking

Long-term observations of deep convective cloud (DCC) vertical velocity and mass flux were collected during the Observations and Modelling of the Green Ocean Amazon (GoAmazon2014/5) experiment. Precipitation echoes from a surveillance weather radar near Manaus, Brazil, are tracked to identify and evaluate the isolated DCC lifecycle evolution during the dry and wet seasons. A radar wind profiler (RWP) provides precipitation and air motion profiles to estimate the vertical velocity, mass flux, and mass transport rates within overpassing DCC cores as a function of the tracked cell lifecycle stage. The average radar reflectivity factor (Z), DCC area (A), and surface rainfall rate (R) increased with DCC lifetime as convective cells were developing, reached a peak as the cells matured, and decreased thereafter as cells dissipated. As the convective cells mature, cumulative DCC properties exhibit stronger updraft behaviors with higher upward mass flux and transport rates above the melting layer (compared with initial and later lifecycle stages). In comparison, developing DCCs have the lowest Z associated with weak updrafts, as well as negative mass flux and transport rates above the melting layer. Over the DCC lifetime, the height of the maximum downward mass flux decreased, whereas the height of the maximum net mass flux increased. During the dry season, the tracked DCCs had higher Z, propagation speed, and DCC area, and were more isolated spatially compared with the wet season. Dry season DCCs exhibit higher Z, mass flux, and mass transport rate while developing, whereas wet season DCCs exhibit higher Z, mass flux, and mass transport rates at later stages.

54 ENVIRONMENTAL SCIENCES↗

Evidence That the Directly Imaged Planet HD 131399 Ab Is a Background Star

Herein we present evidence that the recently discovered, directly imaged planet HD 131399 Ab is a background star with nonzero proper motion. From new JHK1L ' photometry and spectroscopy obtained with the Gemini Planet Imager, VLT/SPHERE, and Keck/NIRC2, and a reanalysis of the discovery data obtained with VLT/SPHERE, we derive colors, spectra, and astrometry for HD 131399 Ab. The broader wavelength coverage and higher data quality allow us to reinvestigate its status. Its near-infrared spectral energy distribution excludes spectral types later than L0 and is consistent with a K or M dwarf, which are the most likely candidates for a background object in this direction at the apparent magnitude observed. If it were a physically associated object, the projected velocity of HD 131399 Ab would exceed escape velocity given the mass and distance to HD 131399 A. We show that HD 131399 Ab is also not following the expected track for a stationary background star at infinite distance. Solving for the proper motion and parallax required to explain the relative motion of HD 131399 Ab, we find a proper motion of 12.3 mas yr –1 . When compared to predicted background objects drawn from a galactic model, we find this proper motion to be high but consistent with the top 4% fastest-moving background stars. From our analysis, we conclude that HD 131399 Ab is a background K or M dwarf.

stars: individual (HD 131399)↗

SU-E-J-57: First Development of Adapting to Intrafraction Relative Motion Between Prostate and Pelvic Lymph Nodes Targets

Purpose Large intrafraction relative motion of multiple targets is common in advanced head and neck, lung, abdominal, gynaecological and urological cancer, jeopardizing the treatment outcomes. The objective of this study is to develop a real-time adaptation strategy, for the first time, to accurately correct for the relative motion of multiple targets by reshaping the treatment field using the multi-leaf collimator (MLC). Methods The principle of tracking the simultaneously treated but differentially moving tumor targets is to determine the new aperture shape that conforms to the shifted targets. Three dimensional volumes representing the individual targets are projected to the beam’s eye view. The leaf openings falling inside each 2D projection will be shifted according to the measured motion of each target to form the new aperture shape. Based on the updated beam shape, new leaf positions will be determined with optimized trade-off between the target underdose and healthy tissue overdose, and considerations of the physical constraints of the MLC. Taking a prostate cancer patient with pelvic lymph node involvement as an example, a preliminary dosimetric study was conducted to demonstrate the potential treatment improvement compared to the state-of- art adaptation technique which shifts the whole beam to track only one target. Results The world-first intrafraction adaptation system capable of reshaping the beam to correct for the relative motion of multiple targets has been developed. The dose in the static nodes and small bowel are closer to the planned distribution and the V45 of small bowel is decreased from 110cc to 75cc, corresponding to a 30% reduction by this technique compared to the state-of-art adaptation technique. Conclusion The developed adaptation system to correct for intrafraction relative motion of multiple targets will guarantee the tumour coverage and thus enable PTV margin reduction to minimize the high target dose to the adjacent organs-at-risk. The authors acknowledge funding support from the Australian NHMRC Australia Fellowship and NHMRC Project Grant No. APP1042375.

60 APPLIED LIFE SCIENCES↗

The straw tracking detector for the Fermilab Muon g-2 Experiment

The Muon g-2 Experiment at Fermilab uses a gaseous straw tracking detector to make detailed measurements of the stored muon beam profile, which are essential for the experiment to achieve its uncertainty goals. Positrons from muon decays spiral inward and pass through the tracking detector before striking an electromagnetic calorimeter. The tracking detector is therefore located inside the vacuum chamber in a region where the magnetic field is large and non-uniform. As such, the tracking detector must have a low leak rate to maintain a high-quality vacuum, must be non-magnetic so as not to perturb the magnetic field and, to minimize energy loss, must have a low radiation length. The performance of the tracking detector has met or surpassed the design requirements, with adequate electronic noise levels, an average straw hit resolution of (110 ± 20) μm, a detection efficiency of 97% or higher, and no performance degradation or signs of aging. The tracking detector's measurements result in an otherwise unachievable understanding of the muon's beam motion, particularly at early times in the experiment's measurement period when there are a significantly greater number of muons decaying. This is vital to the statistical power of the experiment, as well as facilitating the precise extraction of several systematic corrections and uncertainties. This paper describes the design, construction, testing, commissioning, and performance of the tracking detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time Resolved Reflectivity Measurements of Convective Clouds

National Aeronautics and Space Administration's Investigations of Convective Updrafts (INCUS) mission aims to document convective mass flux through changes in the radar reflectivity (ΔZ) in convective cores captured by a constellation of three Ka-band radars sampling the same convective cells over intervals of 30, 90, and 120 s. Here, high spatiotemporal resolution observations of convective cores from surface-based radars that use agile sampling techniques are used to evaluate aspects of the INCUS measurement approach using real observations. Analysis of several convective cells confirms that large coherent ΔZ structure with measurable signal (>5 dB) can occur in less than 30 s and are correlated with underlying convective motions. The analysis indicates that the INCUS mission radar footprint and along track sampling are adequate to capture most of the desirable ΔZ signals. This unique demonstration of reflectivity time-lapse provides the framework for estimating convective mass flux independent from Doppler techniques with future radar observations.

54 ENVIRONMENTAL SCIENCES↗

Microfield dynamics in dense hydrogen plasmas with high- Z impurities

We use large-scale classical molecular dynamics to determine microfield properties for several dense plasma mixtures. By employing quantum statistical potentials (QSPs) to regularize the Coulomb interaction, our simulations follow motions of electrons as well as ions for times long enough to track relaxation phenomena involving both types of particles. Coulomb coupling, relative to temperature, of different pairs of species in the hot, dense matter being simulated ranges from weak to strong. We first study the effect of such coupling differences, along with composition and QSP differences, on the roles of electrons and various mixture components in determining probability distributions of instantaneous, total microfields experienced by the ions. Then, we address two important dynamical questions: (1) How is the quasistatic part of the total field to be extracted from the time-dependent simulation data? (2) Under what conditions does the commonly used approximation of ions with fixed Yukawa-like screening by free electrons accurately describe quasistatic fields? We identify a running, short-time average of the total field at each ion as its slowly evolving, quasistatic part. We consider several ways to specify the averaging interval, and note the influence of ion dynamics in this issue. When all species are weakly coupled, the quasistatic fields have probability distributions agreeing well with those we obtain from simulations of Yukawa-screened ions. However, agreement deteriorates as the coupling between high- Z ions increases well beyond unity, principally because the Yukawa model tends to underestimate the true screening of close high- Z pairs. Lastly, examples of this fact are given, and some consequences for the high-field portions of probability distributions are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗