Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Motion Tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Toward correcting drift in target position during radiotherapy via computer-controlled couch adjustments on a programmable Linac

Purpose: Real-time tracking of respiratory target motion during radiation therapy is technically challenging, owing to rapid and possibly irregular breathing variations. The authors report on a method to predict and correct respiration-averaged drift in target position by means of couch adjustments on an accelerator equipped with such capability. Methods: Dose delivery is broken up into a sequence of 10 s field segments, each followed by a couch adjustment based on analysis of breathing motion from an external monitor as a surrogate of internal target motion. Signal averaging over three respiratory cycles yields a baseline representing target drift. A Kalman filter predicts the baseline position 5 s in advance, for determination of the couch correction. The method's feasibility is tested with a motion phantom programmed according to previously recorded patient signals. Computed couch corrections are preprogrammed into a research mode of an accelerator capable of computer-controlled couch translations synchronized with the motion phantom. The method's performance is evaluated with five cases recorded during hypofractionated treatment and five from respiration-correlated CT simulation, using a root-mean-squared deviation (RMSD) of the baseline from the treatment planned position. Results: RMSD is reduced in all 10 cases, from a mean of 4.9 mm (range 2.7-9.4 mm) before correction to 1.7 mm (range 0.7-2.3 mm) after correction. Treatment time is increased {approx}5% relative to that for no corrections. Conclusions: This work illustrates the potential for reduction in baseline respiratory drift with periodic adjustments in couch position during treatment. Future treatment machine capabilities will enable the use of 'on-the-fly' couch adjustments during treatment.

60 APPLIED LIFE SCIENCES↗

CT imaging during microwave ablation: Analysis of spatial and temporal tissue contraction

Purpose: To analyze the spatial distribution and temporal development of liver tissue contraction during high-temperature ablation by using intraprocedural computed tomography (CT) imaging. Methods: A total of 46 aluminum fiducial markers were positioned in a 60 × 45 mm grid, in a single plane, around a microwave ablation antenna in each of six ex vivo bovine liver samples. Ablations were performed for 10 min at 100 W. CT data of the liver sample were acquired every 30 s during ablation. Fiducial motion between acquisitions was tracked in postprocessing and used to calculate measures of tissue contraction and contraction rates. The spatial distribution and temporal evolution of contraction were analyzed. Results: Fiducial displacement indicated that the zone measured postablation was 8.2 ± 1.8 mm (∼20%) smaller in the radial direction and 7.1 ± 1.0 mm (∼10%) shorter in the longitudinal direction than the preablation tissue dimension. Therefore, the total ablation volume was reduced from its preablation value by approximately 45%. Very little longitudinal contraction was noted in the distal portion of the ablation zone. Central tissues contracted more than 60%, which was near an estimated limit of ∼70% based on initial water content. More peripheral tissues contracted only 15% in any direction. Contraction rates peaked during the first 60 s of heating with a roughly exponential decay over time. Conclusions: Ablation zones measured posttreatment are significantly smaller than the pretreatment tissue dimensions. Tissue contraction is spatially dependent, with the greatest effect occurring in the central ablation zone. Contraction rate peaks early and decays over time.

60 APPLIED LIFE SCIENCES↗

SU-D-210-06: Feasibility for Monitoring the Head of the Pancreas Motion Through a Surrogate Using Ultrasound During Radiation Therapy Delivery

Purpose: Substantial target motion during the delivery of radiation therapy (RT) for pancreatic cancer is well recognized as a major limiting factor on RT effectiveness. The aim of this work is to monitor intra-fractional motion of the pancreas using ultrasound during RT delivery. Methods: Transabdominal Ultrasound B-mode images were collected from 5 volunteers using a research version of the Clarity Autoscan System (Elekta). The autoscan transducer with center frequency of 5 MHz was utilized for the scans. Imaging parameters were adjusted to acquire images at the desired depth with good contrast and a wide sweep angle. Since well-defined boundaries of the pancreas can be difficult to find on ultrasound B-mode images, the portal vein was selected as a surrogate for motion estimation of the head of the pancreas. The selection was due to its anatomical location posterior to the neck of the pancreas and close proximity to the pancreas head. The portal vein was contoured on the ultrasound images acquired during simulation using the Clarity Research AFC Workstation software. Volunteers were set up in a similar manner to the simulation for their monitoring session and the ultrasound transducer was mounted on an arm fixed to the couch. A video segment of the portal vein motion was captured. Results: The portal vein was visualized and segmented. Successful monitoring sessions of the portal vein were observed. In addition, our results showed that the ultrasound transducer itself reduces breathing related motion. This is analogous to the use of a compression plate to suppress respiration motion during thorax or abdominal irradiation. Conclusion: We demonstrate the feasibility of tracking the pancreas through the localization of the portal vein using abdominal ultrasound. This will allow for real-time tracking of the intra-fractional motion to justify PTV-margin and to account for unusual motions, thus, improving normal tissue sparing. This research was funding in part by Elekta Inc.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP3-03: Effect of Robot Pose On Beam Blocking for Ultrasound Guided SBRT of the Prostate

Purpose: Ultrasound presents a fast, volumetric image modality for real-time tracking of abdominal organ motion. How-ever, ultrasound transducer placement during radiation therapy is challenging. Recently, approaches using robotic arms for intra-treatment ultrasound imaging have been proposed. Good and reliable imaging requires placing the transducer close to the PTV. We studied the effect of a seven degrees of freedom robot on the fea-sible beam directions. Methods: For five CyberKnife prostate treatment plans we established viewports for the transducer, i.e., points on the patient surface with a soft tissue view towards the PTV. Choosing a feasible transducer pose and using the kinematic redundancy of the KUKA LBR iiwa robot, we considered three robot poses. Poses 1 to 3 had the elbow point anterior, superior, and inferior, respectively. For each pose and each beam starting point, the pro-jections of robot and PTV were computed. We added a 20 mm margin accounting for organ / beam motion. The number of nodes for which the PTV was partially of fully blocked were established. Moreover, the cumula-tive overlap for each of the poses and the minimum overlap over all poses were computed. Results: The fully and partially blocked nodes ranged from 12% to 20% and 13% to 27%, respectively. Typically, pose 3 caused the fewest blocked nodes. The cumulative overlap ranged from 19% to 29%. Taking the minimum overlap, i.e., considering moving the robot’s elbow while maintaining the transducer pose, the cumulative over-lap was reduced to 16% to 18% and was 3% to 6% lower than for the best individual pose. Conclusion: Our results indicate that it is possible to identify feasible ultrasound transducer poses and to use the kinematic redundancy of a 7 DOF robot to minimize the impact of the imaging subsystem on the feasible beam directions for ultrasound guided and motion compensated SBRT. Research partially funded by DFG grants ER 817/1-1 and SCHL 1844/3-1.

60 APPLIED LIFE SCIENCES↗

Portal Monitoring Considerations for Treaty Verification Applications

Portal monitoring is one method in a suite of options for treaty verification and can assist in verification of treaty accountable items (TAIs). Portal monitor technology spans a wide range of sensors, including radiation detectors, break-beams, or weight sensors. For radiation-detecting portal monitors, they are able to confirm absence / presence of a radiological signature and to track TAI direction of motion. Portal monitoring uses measurements from strategically placed sensors (e.g., radiation detectors) to record the entry or egress of TAIs. The implementation of portal monitoring relies on three key elements: perimeter definition, portal locations, and sensor technology, and can be implemented in either time-bound or continuous operations depending on what is permitted by the Treaty.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Dynamic satellite geodesy

The paper describes operation of the GEOS-3 and Lageos spacecraft launched by NASA as part of the Earth and Ocean Dynamic Program. The investigations conducted by using GEOS-3 include the determination of tracking station coordinates, polar motion, and the use of altimetry in orbit determination. Lageos was designed as a precision target for making geodetic measurements with ground laser systems. Consideration is given to the progress made in the investigation and determination of tidal parameters by means of satellite perturbation methods. Satellite geodetic methods based on the ability to determine precise satellite orbits and orbit determination are outlined. Emphasis is placed on the future studies employing Spaceborne Laser and Global Positioning System concepts.

Smith, D. E.↗

A system study for the application of microcomputers to research flight test techniques

The onboard simulator is a three degree of freedom aircraft behavior simulator which provides parameters used by the interception procedure. These parameters can be used for verifying closed loop performance before flight. The air to air intercept mode is a software package integrated in the simulation process that generates a target motion and performs a tracking procedure that predicts the most likely next target position, for a defined time step. This procedure also updates relative position parameters and gives adequate fire commands. A microcomputer based on an aircraft spin warning system periodically samples the assymetric thrust and yaw rate of an airplane and then issues voice synthesized warnings and /or suggests to the ilot how to respond to the situation.

Smyth, R. K.↗

Application of model reference adaptive control to a flexible remote manipulator arm

An exact modal state-space representation is derived in detail for a single-link, flexible remote manipulator with a noncollocated sensor and actuator. A direct model following adaptive controller is designed to control the torque at the pinned end of the arm so as to command the free end to track a prescribed sinusoidal motion. Conditions that must be satisfied in order for the controller to work are stated. Simulation results to date are discussed along with the potential of the model following adaptive control scheme in robotics and space environments.

Meldrum, D. R.↗

Satellite contributions to convective scale weather analysis and forecasting

Severe weather phenomena which are amenable to remote sensing by satellite instruments and having resolution fine enough to discern mesoscale features are described. GOES satellites acquire imagery with 1 km resolution in the visible band and 8 km at IR wavelengths. Animation of the images allows tracking the evolution and motions of clouds, which are the prime indicators of convective activity. Sample satellite imagery of sea, lake and river breezes which reveal differential heating processes, the effect of early morning cloud cover, thunderstorm outflow processes, and mesoscale convective systems are provided. Techniques for analyzing the satellite data to predict the onset of severe weather are discussed.

Purdom, James F. W.↗

Control of joint motion simulators for biomechanical research

The authors present a hierarchical adaptive algorithm for controlling upper extremity human joint motion simulators. A joint motion simulator is a computer-controlled, electromechanical system which permits the application of forces to the tendons of a human cadaver specimen in such a way that the cadaver joint under study achieves a desired motion in a physiologic manner. The proposed control scheme does not require knowledge of the cadaver specimen dynamic model, and solves on-line the indeterminate problem which arises because human joints typically possess more actuators than degrees of freedom. Computer simulation results are given for an elbow/forearm system and wrist/hand system under hierarchical control. The results demonstrate that any desired normal joint motion can be accurately tracked with the proposed algorithm. These simulation results indicate that the controller resolved the indeterminate problem redundancy in a physiologic manner, and show that the control scheme was robust to parameter uncertainty and to sensor noise.

Colbaugh, R.↗

Space Telescope Fine Guidance Sensor Bearing Anomaly

Early in 1993, a servo motor within one of three Fine Guidance Sensors (FGS) aboard the Hubble Space Telescope (HST) reached stall torque levels on several occasions. Little time was left to plan replacement during the first servicing mission, scheduled at the end of '93. Accelerated bearing life tests confirmed that a small angle rocking motion, known as Coarse Track (CT), accelerated bearing degradation. Saturation torque levels were reached after approximately 20 million test cycles, similar to the flight bearings. Reduction in CT operation, implemented in flight software, extended FGS life well beyond the first servicing mission. However in recent years, bearing torques have resumed upward trends and together with a second, recent bearing torque anomaly has necessitated a scheduled FGS replacement during the upcoming second servicing mission in '97. The results from two series of life tests to quantify FGS bearing remaining life, discussion of bearing on-orbit performance, and future plans to service the FGS servos are presented in this paper.

Loewenthal, S.↗

Flight Simulation Scenarios for Commercial Pilot Training and Crew State Monitoring

NASA Langley researchers addressed the Commercial Aviation Safety Team Safety Enhancement 211 through a series of studies to address "Attention-related Human Performance Limiting States" which include channelized attention, diverted attention, startle/surprise, and confirmation bias. The present report focuses on the development of improved training scenarios for operationally realistic Line-Oriented Flight Training scenarios. Areas addressed in the report include: (1) Highlights of events in the LOFT scenario used; (2) Interesting findings with implications for simulator motion; (3) Eye-tracking heat maps in proximity to failure events; (4) Researcher observations of crews as test subjects versus a pilot and a research team co-pilot; and (5) The results of a follow-up questionnaire completed by pilot participants regarding their usual training as well as the scenarios employed in the SHARP studies. These pilot ratings and comments are of value to simulation training developers.

James R. Comstock, Jr.↗

SIM white light on-board processing algorithms

Interferometry in optical astronomy is an important and growing field of astronomical observation. A number of stellar interferometers have come online over the past several years, and several more are due to be operational in the near future. In addition, space based interferometers are also planned missions of NASA's Origins program, including the Space Interferometry Mission (SIM), the focus of the present paper. The fundamental measurement made by each of these interferometers is the white light fringe measurement to determine the optical pathlength delay between the two arms of the interferometer. SIM makes white light measurements with three independent interferometers observing three different objects. Two of these are the "guide" interferometers that observe bright objects (approximately 7th magnitude) to track the rigid body motion of the instrument. The third interferometer, the "science" interferometer, observes the science targets of interest.

interferometry↗

Lunar Scout Infrared Detector (LSIRD): Simple low-cost imaging spectrometer

A novel design for a compact, light weight, imaging spectrometer has been proposed for an orbiting Lunar mapping mission. Simple in design, its dual arm optical system employs a transmission grating and a dichroic mirror to provide continous two-octave spectral response. The grating's first order wavelengths are reflected into the SWIR arm, while the second order wavelenghts are transmitted to the VNIR arm. The instrument design is that of a push broom camera. It uses one of the detector(s) dimensions for spectral selection, the other detector(s) dimension for cross-track spatial selection, and the foward motion of the platform (in this case, a spececraft) for down-track spatial coverage.

Lunar↗

Lunar Surface Mixed Reality and ARGOS Trainer

This Artemis focused Mixed Reality (MR) and ARGOS project extends the current VR/ARGOS CIF project to enhance and add VR/MR capabilities to support analysis, training and risk reduction for lunar surface EVA operations in the extreme South Pole lunar environment. This third year focused on establishing a functional trainer for crew that supports the ingress/egress of a lander as well as surface tasks such as sample collection and tool deployment and operation. Completed enhancements include improving hand tracking, the addition of supporting mixed reality surface operations, and the implementation of a higher fidelity body tracking capability through a motion capture system.

Lunar↗

Target-specific optimization of four-dimensional cone beam computed tomography

Purpose: Under-sampling artifacts are a major problem in four-dimensional cone-beam computed tomography (4D-CBCT) and may compromise evaluation of target motion. Several studies have addressed scan parameter selection for minimizing under-sampling artifacts; however, the role of the target characteristics in scan parameter selection has not been investigated. In this work, the authors evaluated 4D-CBCT performance by assessing the accuracy of target motion measurements for various target sizes and motions. The results may serve as patient-specific guidelines for scan parameters selection in 4D-CBCT. Methods: The authors acquired 4D-CBCT scans of a moving phantom consisting of six water-filled sphere targets of sizes 10-37 mm, using various scan times ranging from 30 s to 3 min., setting the motion to 3-s and 6-s periods. The authors used automatic image registration to extract the target motion trajectories and evaluated these measurements for various target sizes and motions over various combinations of scan parameters including scan time, detector configuration, number of respiration phases, and reconstruction filters. Results: The most important object parameter to 4D-CBCT performance was the period of motion. Measurements for the 6-s motion were always systematically less accurate than measurements for the 3-s motion for 34 of 36 objects of various sizes and periods of motion. The 6-s motion required a greater scan time than the 3-s motion for equivalent measurement accuracy. The second most influential parameter was the target size. For the 3-s period of motion, objects larger than 13 mm were tracked with sub-millimeter accuracy with a 1-min scan time. For the 6-s period of motion, objects larger than 22-mm were tracked with sub-millimeter accuracy with a 1.5-min scan time. For all sizes and motions, temporal blurring was observed when the number of phases was fewer than 8. Offset detector configuration provided the same performance as centered detector except for small targets (20 mm.) at short scan times ({<=}1 min). Finally, reconstruction filtering and number of respiratory phases did not affect performance. Conclusions: Scan time should be set according to target size and motion. The authors have provided figures that provide the minimum scan time needed to achieve the particular motion measurement accuracy for a particular size and motion period.

60 APPLIED LIFE SCIENCES↗

Proper Motions of Stellar Streams Discovered in the Dark Energy Survey

We cross-match high-precision astrometric data from Gaia DR2 with accurate multi-band photometry from the Dark Energy Survey (DES) DR1 to confidently measure proper motions for nine stellar streams in the DES footprint: Aliqa Uma, ATLAS, Chenab, Elqui, Indus, Jhelum, Phoenix, Tucana III, and Turranburra. We determine low-confidence proper motion measurements for four additional stellar streams: Ravi, Wambelong, Willka Yaku, and Turbio. We find evidence for a misalignment between stream tracks and the systemic proper motion of streams that may suggest a systematic gravitational influence from the Large Magellanic Cloud. These proper motions, when combined with radial velocity measurements, will allow for detailed orbit modeling which can be used to constrain properties of the LMC and its affect on nearby streams, as well as global properties of the Milky Way's gravitational potential.

79 ASTRONOMY AND ASTROPHYSICS↗