Monte Carlo simulation of an expanding gas

By application of simple computer graphics techniques, the statistical performance of two Monte Carlo methods used in the simulation of rarefied gas flows are assessed. Specifically, two direct simulation Monte Carlo (DSMC) methods developed by Bird and Nanbu are considered. The graphics techniques are found to be of great benefit in the reduction and interpretation of the large volume of data generated, thus enabling important conclusions to be drawn about the simulation results. Hence, it is discovered that the method of Nanbu suffers from increased statistical fluctuations, thereby prohibiting its use in the solution of practical problems.

Boyd, Iain D.↗

Quantum Monte Carlo benchmarking of large noncovalent complexes in the L7 benchmark set

We have used diffusion Monte Carlo (DMC) to perform calculations on the L7 benchmark set. DMC is a stochastic numerical integration scheme in real-space and part of a larger set of quantum Monte Carlo methods. The L7 set was designed to test the ability of electronic structure methods to include dispersive interactions. While the agreement between DMC and quantum-chemical state-of-the-art methods is excellent for some of the structures, there are significant differences in others. In contrast to wavefunction-based quantum chemical methods, DMC is a first-principle many-body method with the many-body wavefunction evolving in real space. It includes explicitly all electron–electron interactions and is relatively insensitive to the size of the basis set.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uncertainty Quantification of Geophysical Inversion Using Stochastic Partial Differential Equations (LDRD #218329)

This report summarizes work completed under the Laboratory Directed Research and Development (LDRD) project "Uncertainty Quantification of Geophysical Inversion Using Stochastic Differential Equations." Geophysical inversions often require computationally expensive algorithms to find even one solution, let alone propagating uncertainties through to the solution domain. The primary purpose of this project was to find more computationally efficient means to approximate solution uncertainty in geophysical inversions. We found multiple computationally efficient methods of propagating Earth model uncertainty into uncertainties in solutions of full waveform seismic moment tensor inversions. However, the optimum method of approximating the uncertainty in these seismic source solutions was to use the Karhunen-Love theorem with data misfit residuals. This method was orders of magnitude more computationally efficient than traditional Monte Carlo methods and yielded estimates of uncertainty that closely approximated those of Monte Carlo. We will summarize the various methods we evaluated for estimating uncertainty in seismic source inversions as well as work toward this goal in the realm of 3-D seismic tomographic inversion uncertainty.

58 GEOSCIENCES↗

Time-step limits for a Monte Carlo Compton-scattering method

We perform a stability analysis of a Monte Carlo method for simulating the Compton scattering of photons by free electron in high energy density applications and develop time-step limits that avoid unstable and oscillatory solutions. Implementing this Monte Carlo technique in multi physics problems typically requires evaluating the material temperature at its beginning-of-time-step value, which can lead to this undesirable behavior. With a set of numerical examples, we demonstrate the efficacy of our time-step limits.

97 MATHEMATICS AND COMPUTING↗

Hydrogen adsorption in metal-organic frameworks: The role of nuclear quantum effects

The role of nuclear quantum effects on the adsorption of molecular hydrogen in metal-organic frameworks (MOFs) has been investigated on grounds of Grand-Canonical Quantized Liquid Density-Functional Theory (GC-QLDFT) calculations. For this purpose, we have carefully validated classical H{sub 2}-host interaction potentials that are obtained by fitting Born-Oppenheimer ab initio reference data. The hydrogen adsorption has first been assessed classically using Liquid Density-Functional Theory and the Grand-Canonical Monte Carlo methods. The results have been compared against the semi-classical treatment of quantum effects by applying the Feynman-Hibbs correction to the Born-Oppenheimer-derived potentials, and by explicit treatment within the GC-QLDFT. The results are compared with experimental data and indicate pronounced quantum and possibly many-particle effects. After validation calculations have been carried out for IRMOF-1 (MOF-5), GC-QLDFT is applied to study the adsorption of H{sub 2} in a series of MOFs, including IRMOF-4, -6, -8, -9, -10, -12, -14, -16, -18, and MOF-177. Finally, we discuss the evolution of the H{sub 2} quantum fluid with increasing pressure and lowering temperature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deterministic Simulation of First-Order Scattering in a Clinical X-ray Computed Tomography Scanner - Paper 81

In nondestructive testing (NDT) and medical diagnostic x-ray imaging (photon energy<140 keV), scattered x-ray caused by Compton and Rayleigh scattering should be eliminated. Scattered x-ray photons reduce image contrast, increase image noise, and introduce artifact into the reconstructed computed tomography (CT) images. In cone-beam CT, where the coverage of the x-ray beam and the area of the detector are significantly larger than those in fan-beam CT, x-ray photon scatter is one of the major sources of image degradation. The artifacts caused by scattered x-ray photon can be divided into two categories: 1) low spatial frequency scatter profile adds a positive bias to the detected radiation signal, thus reducing the effective attenuation of the imaged object, resulting in a negative bias in the measured linear attenuation coefficient in the image; 2) a high spatial frequency scatter profile causes a differential artifact, such as shading in uniform regions. A real x-ray scan is composed of both low and high frequency scatter profiles. Thus, the key to a successful scatter correction is the ability to accurately capture the scatter profile of a real x-ray imaging scan. The most accurate method for estimating a scatter profile is the Monte Carlo simulation. However, the computation cost of the Monte Carlo method makes it unfeasible for simulating real and complex scan geometries in clinical settings. A practical yet accurate scatter profile estimation method is through ray tracing techniques, where the scatter profiles are computed by tracking rays through the object's volume. The x-ray from the source is tracked when it interacts with the material in the volume. The interaction creates scattered x-rays, in all possible directions. These rays are again either attenuated or scattered, creating cascaded scatter events. In x-ray CT, the first-order scattering (where only one scatter interaction is encountered) accounts for the most severe image artifacts since this first-order scatter contains a high frequency component of the scatter profile. Previous studies have shown that ray tracing techniques are quite effective in simulating the contribution of first-order scattering in radiological images. In this study, a similar ray tracing technique is applied to simulate the scatter profile of a real x-ray computed tomography (CT) scan in clinical settings. A good agreement has been found between the simulated scatter profile and the experimental measurement result. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Influence of the Si(111)-7 Multiplication-Sign 7 surface reconstruction on the diffusion of strontium atoms

The diffusion of strontium atoms on the Si(111) surface at room temperature has been investigated using scanning tunnel microscopy and simulation carried out in terms of the density functional theory and the Monte Carlo method. It has been found that the reconstruction of a clean silicon surface with a 7 Multiplication-Sign 7 structure has a profound effect on the diffusion process. The average velocity of motion of a strontium atom in a unit cell of the 7 Multiplication-Sign 7 structure has been calculated. The main diffusion paths of a strontium atom and the corresponding activation energies have been determined. It has been demonstrated that the formation of scanning tunnel microscope images of the Si(111)-7 Multiplication-Sign 7 surface with adsorbed strontium atoms is significantly affected by the shift of the electron density from the strontium atom to the nearest neighbor silicon adatoms in the 7 Multiplication-Sign 7 structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sci—Thur AM: YIS - 06: An EPID-based 3D patient dose verification method for SBRT-VMAT delivery

Purpose: Stereotactic body radiation therapy (SBRT) delivered via volumetric modulated arc therapy (VMAT) can strongly benefit from an in vivo patient dose verification due to the large doses per fraction. Electronic portal imaging devices (EPIDs) can be utilized as a patient dose dosimeter. In this work we present a physics-based model which utilizes on-treatment EPID images to reconstruct the dose delivered to an anthropomorphic phantom during SBRT-VMAT delivery. Methods: An SBRT linac beam was modeled using Monte Carlo methods and verified with measured data. Our dose reconstruction model back-projects EPID measured focal fluence upstream of the patient and adds a predicted extra-focal fluence component. This fluence is forward projected onto the patient's density matrix and convolved with dose kernels to calculate dose. The model was validated for two prostate, three lung, and two spine SBRT-VMAT treatments. Results were compared to the treatment planning system's calculation. Results: 2%/2 mm chi comparison calculations gave pass rates for the whole volume, infield, and high dose region respectively, and no lower than: 98%, 95%, 99% for the prostate plans, 99%, 92%, 85% for the lung plans, and 91%, 85%, 81% for the spine plans. A 3%/3mm calculation gave pass rates no lower than 99%, 94%, and 90% for all dose regions for the prostate, lung, and spine respectively. Conclusions: We have developed a physics-based model which calculates delivered dose to phantom (or patient) for SBRT-VMAT delivery using on treatment EPID images. The accuracy of the results has allowed us to test this model clinically.

60 APPLIED LIFE SCIENCES↗

Coupled-cluster method: A lattice-path-based subsystem approximation scheme for quantum lattice models

An approximation hierarchy, called the lattice-path-based subsystem (LPSUBm) approximation scheme, is described for the coupled-cluster method (CCM). It is applicable to systems defined on a regular spatial lattice. We then apply it to two well-studied prototypical (spin-(1/2) Heisenberg antiferromagnetic) spin-lattice models, namely, the XXZ and the XY models on the square lattice in two dimensions. Results are obtained in each case for the ground-state energy, the ground-state sublattice magnetization, and the quantum critical point. They are all in good agreement with those from such alternative methods as spin-wave theory, series expansions, quantum Monte Carlo methods, and the CCM using the alternative lattice-animal-based subsystem (LSUBm) and the distance-based subsystem (DSUBm) schemes. Each of the three CCM schemes (LSUBm, DSUBm, and LPSUBm) for use with systems defined on a regular spatial lattice is shown to have its own advantages in particular applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

WE-G-BRD-05: Inline Magnetic Fields Enhance Tumor Dose for Small Lung Cancers

Purpose: To report on significant dose enhancement effects caused by magnetic fields aligned parallel to 6MV photon beam radiotherapy of small lung tumors. Findings are applicable to future inline MRI-guided radiotherapy systems. Methods: 9 clinical lung plans were recalculated using Monte Carlo methods and external inline (parallel to the beam direction) magnetic fields of 0.5 T, 1.0 T and 3 T were included. Three plans were 6MV 3D-CRT and six were 6MV IMRT. The GTV’s ranged from 0.8 cc to 73 cc, while the PTV ranged from 1 cc to 180 cc. Results: The inline magnetic field has a moderate impact in lung dose distributions by reducing the lateral scatter of secondary electrons and causing a small local dose increase. Superposition of multiple small beams acts to superimpose the small dose increases and can lead to significant dose enhancements, especially when the GTV is low density. Two plans with very small, low mean density GTV’s (<1 cc, ρ(mean)<0.35g/cc) showed uniform increases of 16% and 23% at 1 T throughout the PTV. Three plans with moderate mean density PTV’s (3–13 cc, ρ(mean)=0.58–0.67 g/cc) showed 6% mean dose enhancement at 1 T in the PTV, however not uniform throughout the GTV/PTV. Replanning would benefit these cases. The remaining 5 plans had large dense GTV’s (∼ 1 g/cc) and so only a minimal (<2%) enhancement was seen. In general the mean dose enhancement at 0.5 T was 60% less than 1 T, while 5–50% higher at 3 T. Conclusions: A paradigm shift in the efficacy of small lung tumor radiotherapy is predicted with future inline MRI-linac systems. This will be achieved by carefully taking advantage of the reduction of lateral electronic disequilibrium withing lung tissue that is induced naturally inside strong inline magnetic fields.

60 APPLIED LIFE SCIENCES↗

ORBITS OF NEARBY PLANETARY NEBULAE AND THEIR INTERACTION WITH THE INTERSTELLAR MEDIUM

We present and analyze the orbits of eight nearby planetary nebulae (PNs) using two different Galactic models. The errors of the derived orbital parameters are determined with a Monte Carlo method. Based on the derived orbital parameters, we find that Sh 2-216, DeHt 5, NGC 7293, A21, and Ton 320 belong to the thin-disk population, and PG 1034 + 001 and A31 belong to the thick-disk population. PuWe 1 probably belongs to the thick-disk population, but its population classification is very uncertain due to the large errors of its derived orbital parameters. The PN-interstellar medium (ISM) interactions are observed for the eight PNs in our sample. The position angles of the proper motions of the PNs are consistent with the directions of the PN-ISM interaction regions. The kinematic ages of PNs are much smaller than the time for them to cross the Galactic plane. Using the models of Borkowski et al. and Soker et al., the PN-ISM interaction can be used to derive the local density of ISM in the vicinity of evolved PNs. According to the three-dimensional hydrodynamic simulations of Wareing et al. (WZO), Sh 2-216, A21, and Ton 320 are in the WZO 3 stage, PG 1034 + 001 and NGC 7293 are in the WZO 1 stage, and PuWe 1 is in the WZO 2 stage.

79 ASTRONOMY AND ASTROPHYSICS↗

An EGSnrc Monte Carlo-calculated database of TG-43 parameters

Monte Carlo methods are used to calculate a complete TG-43 dosimetry parameter data set for 27 low-energy photon emitting brachytherapy sources (18 {sup 125}I and 9 {sup 103}Pd). All Monte Carlo calculations are performed using the EGSnrc user-code BrachyDose. TG-43 dosimetry parameters, including dose rate constants, radial dose functions (with functional fitting parameters), and anisotropy data, are calculated with finer spatial resolution, greater range of distances, and smaller uncertainties than data currently available in the literature for many of these sources. In particular, for most of the seeds, this is the first time that anisotropy data have been tabulated at distances less than 0.5 cm from the source. These calculations employ the state-of-the-art XCOM photon cross sections, and detailed source geometries are modeled using Yegin's multigeometry package. This data set serves as a completely independent verification of the currently available dosimetry parameters calculated using other Monte Carlo codes, including MCNP and PTRAN. This report also describes the Carleton Laboratory for Radiotherapy Physics TG-43 Parameter Database, a publicly accessible web site (at http://www.physics.carleton.ca/clrp/seed{sub d}atabase/) through which all of the data calculated for this study can be accessed. Also available on the web site are descriptions of the methods and Monte Carlo models used in this study and comparisons of data calculated in this study with data calculated by other authors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analytical Assessment for Transient Stability Under Stochastic Continuous Disturbances

Here, with the growing integration of renewable power generation, plug-in electric vehicles, and other sources of uncertainty, increasing stochastic continuous disturbances are brought to power systems. The impact of stochastic continuous disturbances on power system transient stability attracts significant attention. To address this problem, this paper proposes an analytical assessment method for transient stability of multi-machine power systems under stochastic continuous disturbances. In the proposed method, a probability measure of transient stability is presented and analytically solved by stochastic averaging. Compared with the conventional method (Monte Carlo simulation), the proposed method is many orders of magnitude faster, which makes it very attractive in practice when many plans for transient stability must be compared or when transient stability must be analyzed quickly. Also, it is found that the evolution of system energy over time is almost a simple diffusion process by the proposed method, which explains the impact mechanism of stochastic continuous disturbances on transient stability in theory.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deterministic-Monte Carlo Hybrid Methods for Eigenvalue Sensitivity Coefficient Calculations [Slides]

Hybrid method was developed based on a need to generate accurate sensitivities for specified systems with CLUTCH. This new method provides improved sensitivities with HMF-028-001, specifically with 238 U in the large reflector region. With the importance of each voxel predetermined with the adjoint flux, the hybrid method is able to generate more accurate sensitivities. More testing is needed for other types of systems and materials (i.e., thermal and intermediate energy ranges and different moderators and reflectors). Initial results are very promising and continual development of the new hybrid method is currently in progress.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗