Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Magnetic Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

New Experiments with Spinning Metallic Discs

A number of recent advanced theories related to torsion properties of the space-time matrix predict the existence of an interaction between classically spinning objects. Indeed, some experimental data suggest that spinning magnetic bodies discernibly interact with Earth's natural fields. If there are interactions between rotating bodies then nuclear spins could be used for detection. Thus, assuming a spinning body induces a hypothetical torsion field, a sensor based on the giant magnetoresistance effect would detect local changes. Experimentally, spinning a brass wheel shielded from Earth's magnetic field showed no measurable change in signals; with no shielding a Faraday disc phenomenon was observed. Unexpected experimental measurements from the non-axial Faraday disc configuration were recorded and a theoretical model was derived to explain them.

Mazuruk, Konstantin↗

Position Sensor Integral with a Linear Actuator

A noncontact position sensor has been designed for use with a specific two-dimensional linear electromagnetic actuator. To minimize the bulk and weight added by the sensor, the sensor has been made an integral part of the actuator: that is to say, parts of the actuator structure and circuitry are used for sensing as well as for varying position. The actuator (see Figure 1) includes a C-shaped permanent magnet and an armature that is approximately centered in the magnet gap. The intended function of the actuator is to cause the permanent magnet to translate to, and/or remain at, commanded x and y coordinates, relative to the armature. In addition, some incidental relative motion along the z axis is tolerated but not controlled. The sensor is required to measure the x and y displacements from a nominal central position and to be relatively insensitive to z displacement. The armature contains two sets of electromagnet windings oriented perpendicularly to each other and electrically excited in such a manner as to generate forces in the x,y plane to produce the required motion. Small sensor excitation coils are mounted on the pole tips of the permanent magnet. These coils are excited with a sine wave at a frequency of 20 kHz. This excitation is transformer-coupled to the armature windings. The geometric arrangement of the excitation coils and armature windings is such that the amplitudes of the 20-kHz voltages induced in the armature windings vary nearly linearly with x and y displacements and do not vary significantly with small z displacements. Because the frequency of 20 kHz is much greater than the maximum frequency characteristic of the actuation signals applied to the armature windings, there is no appreciable interference between actuator and sensor functions of the armature windings.

Howard, David E.↗

Three axis attitude control system

A three-axis attitude control system for an orbiting body comprised of a motor driven flywheel supported by a torque producing active magnetic bearing is described. Free rotation of the flywheel is provided about its central axis and together with limited angular torsional deflections of the flywheel about two orthogonal axes which are perpendicular to the central axis. The motor comprises an electronically commutated DC motor, while the magnetic bearing comprises a radially servoed permanent magnet biased magnetic bearing capable of producing cross-axis torques on the flywheel. Three body attitude sensors for pitch, yaw and roll generate respective command signals along three mutually orthogonal axes (x, y, z) which are coupled to circuit means for energizing a set of control coils for producing torques about two of the axes (x and y) and speed control of the flywheel about the third (z) axis. An energy recovery system, which is operative during motor deceleration, is also included which permits the use of a high-speed motor to perform effectively as a reactive wheel suspended in the magnetic bearing.

Studer, Philip A.↗

Signal amplification in a solid-state sensor through asymmetric many-body echo

Electronic spins of nitrogen–vacancy centres in diamond constitute a promising system for micro- and nanoscale magnetic sensing, because of their operation under ambient conditions, ease of placement in close proximity to sensing targets and biological compatibility. At high densities, the electronic spins interact through dipolar coupling, which typically limits but can also potentially enhance sensing performance. Here we report the experimental demonstration of many-body signal amplification in a solid-state, room-temperature quantum sensor. Our approach uses time-reversed two-axis-twisting interactions, engineered through dynamical control of the quantization axis and Floquet engineering in a two-dimensional ensemble of nitrogen–vacancy centres. We observe that optimal amplification occurs when the backward evolution time equals twice the forward evolution time, in sharp contrast to the conventional Loschmidt echo. These observations can be understood as resulting from an underlying time-reversed mirror symmetry of the microscopic dynamics, providing key insights into signal amplification and opportunities for practical entanglement-enhanced quantum sensing.

quantum information↗

Reducing Field Distortion in Magnetic Resonance Imaging

A concept for a magnetic resonance imaging (MRI) system that would utilize a relatively weak magnetic field provides for several design features that differ significantly from the corresponding features of conventional MRI systems. Notable among these features are a magnetic-field configuration that reduces (relative to the conventional configuration) distortion and blurring of the image, the use of a superconducting quantum interference device (SQUID) magnetometer as the detector, and an imaging procedure suited for the unconventional field configuration and sensor. In a typical application of MRI, a radio-frequency pulse is used to excite precession of the magnetic moments of protons in an applied magnetic field, and the decaying precession is detected for a short time following the pulse. The precession occurs at a resonance frequency proportional to the strengths of the magnetic field and the proton magnetic moment. The magnetic field is configured to vary with position in a known way; hence, by virtue of the aforesaid proportionality, the resonance frequency varies with position in a known way. In other words, position is encoded as resonance frequency. MRI using magnetic fields weaker than those of conventional MRI offers several advantages, including cheaper and smaller equipment, greater compatibility with metallic objects, and higher image quality because of low susceptibility distortion and enhanced spin-lattice-relaxation- time contrast. SQUID MRI is being developed into a practical MRI method for applied magnetic flux densities of the order of only 100 T

Eom, Byeong Ho↗

Acoustic MEMS Sensor Array for Quench Detection of CICC Superconducting Cables

A novel quench detection method using microelectro- mechanical system (MEMS) sensor technology has been investigated in use for high temperature superconducting (HTS) conductors such REBCO tape cables. The sensor array along a superconducting cable, such as a cable-in-conduit-conductor (CICC), is installed in a cooling channel. It will allow sensitive and quick detection for a local quench of a superconducting cable. This work has confirmed that a quench of a single REBCO tape can be detected in liquid nitrogen by a MEMS piezoelectric microphone sensor. The quench detection design utilizing a MEMS sensor array method is discussed for the case of a toroidal field (TF) magnets of a fusion Tokamak device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On a photon-counting array using the Fairchild CCD-201

The evaluation of certain performance parameters of the Fairchild CCD 201 and the proposed method of operation of an electron bombarded charge coupled device are described. Work in progress on the evaluation of the parameters relevant to remote, low noise operation is reported. These tests have been conducted using light input. The video data from the CCD are amplified, digitized, stored in a minicomputer memory, and then recorded on magnetic tape for analyzing. The device will be used in an array of sensors in the aperture plane of a telescope to discriminate between photoelectron events, and in the focal plane operating at single photoelectron sensitivity at a minimum of blooming and lag.

Currie, D. G.↗

On long-wavelength magnetic anomalies over Indian region

A data set composed of vector magnetic measurements obtained by MAGSAT and very accurate altitude determinations made using Sun sensors and star cameras was used to obtain data for very quiet days over the Indian region at 10 S to 40 N and 60 E to 110 E in an effort to determine the validity of quantitative estimates made from aeromagnetic data obtained by removing the core field. To further account for the external effects, the ring current contributions estimated using both X and Z variations were subtracted from the observed values. Before this, the core contribution was eliminated through a spherical harmonic expansion with terms up to N=13. Analysis of the residual measurements using Fast Fourier techniques indicates that the anomalies contain substantial power for wavelengths of about 1500 kms. Because the ring current effect has a spatial structure of this dimension over India, efforts are being made to exactly eliminate these two interfering effects from the data.

Srinivasan, S.↗

In Situ Data

In-situ planetary data include all measurements made by a wide variety of instruments whose sensors are exposed directly to the planetry environment. Typical measurements include those of magnetic fields, energetic particle densities and energy distributions, plasma wave characteristics, ionospheric and neutral gas densities, temperatures, composition and motions. A large body of scientists in the United States, and the world, are involved in research using in-situ data. Many of these scientists are associated with Mission investigations groups which provide specific types of in-situ data. These groups, in the course of data analysis, use data provided by similar groups. The interdisciplinary nature of these investigations fosters exchange and reliance upon one another for data is heavy. To a lesser extent, correlative data sets are obtained from the National Space Science Data Center (NSSDC). However, the data entries often have limited temporal and spatial resolution, are of uncertain quality, and are usually available only for measurements that are several years old.

Source record↗

Aerospace Applications of Magnetic Suspension Technology, part 1

Papers presented at the conference on aerospace applications of magnetic suspension technology are compiled. The following subject areas are covered: pointing and isolation systems; microgravity and vibration isolation; bearing applications; wind tunnel model suspension systems; large gap magnetic suspension systems; control systems; rotating machinery; science and application of superconductivity; and sensors.

Groom, Nelson J.↗

Rotordynamic Characterization of a Hybrid Superconductor Magnet Bearing

A hybrid superconductor magnet bearing uses magnetic forces between permanent magnets to provide lift and the flux pinning force between permanent magnets and superconductors to stabilize against instabilities intrinsic to the magnetic force between magnets. We have constructed a prototype kinetic energy storage system, using a hybrid superconductor magnet bearing to support a 42 lb. flywheel at the center. With five sensors on the periphery of the flywheel, we have monitored the position and attitude of the flywheel during its spin down. The results indicate low values of stiffnesses for the bearing. The implications of this and other consequences will be discussed.

Ma, Ki B.↗

Manipulating Neutral Atoms in Chip-Based Magnetic Traps

Several techniques for manipulating neutral atoms (more precisely, ultracold clouds of neutral atoms) in chip-based magnetic traps and atomic waveguides have been demonstrated. Such traps and waveguides are promising components of future quantum sensors that would offer sensitivities much greater than those of conventional sensors. Potential applications include gyroscopy and basic research in physical phenomena that involve gravitational and/or electromagnetic fields. The developed techniques make it possible to control atoms with greater versatility and dexterity than were previously possible and, hence, can be expected to contribute to the value of chip-based magnetic traps and atomic waveguides. The basic principle of these techniques is to control gradient magnetic fields with suitable timing so as to alter a trap to exert position-, velocity-, and/or time-dependent forces on atoms in the trap to obtain desired effects. The trap magnetic fields are generated by controlled electric currents flowing in both macroscopic off-chip electromagnet coils and microscopic wires on the surface of the chip. The methods are best explained in terms of examples. Rather than simply allowing atoms to expand freely into an atomic waveguide, one can give them a controllable push by switching on an externally generated or a chip-based gradient magnetic field. This push can increase the speed of the atoms, typically from about 5 to about 20 cm/s. Applying a non-linear magnetic-field gradient exerts different forces on atoms in different positions a phenomenon that one can exploit by introducing a delay between releasing atoms into the waveguide and turning on the magnetic field.

Aveline, David↗

Advances in terrestrial physics research at NASA/Goddard Space Flight Center

Some past, current, and future terrestrial physics research activities at NASA/Goddard Space Flight Center are described. The uses of satellites and sensors, such as Tiros, Landsat, Nimbus, and SMMR, for terrestrial physics research are discussed. The spaceborne data are applicable for monitoring and studying vegetation, snow, and ice dynamics; geological features; soil moisture; water resources; the geoid of the earth; and the earth's magnetic field. Consideration is given to improvements in remote sensing systems and data records and the Earth Observing System sensor concepts.

Salomonson, Vincent V.↗

NASA Tech Briefs, February 2012

This issue contains the following briefs: (1) Optical Comb from a Whispering Gallery Mode Resonator for Spectroscopy and Astronomy Instruments Calibration (2) Real-Time Flight Envelope Monitoring System (3) Nemesis Autonomous Test System (4) Mirror Metrology Using Nano-Probe Supports (5) Automated Lab-on-a-Chip Electrophoresis System (6) Techniques for Down-Sampling a Measured Surface Height Map for Model Validation (7) Multi-Component, Multi-Point Interferometric Rayleigh/Mie Doppler Velocimeter (8) Frequency to Voltage Converter Analog Front-End Prototype (9) Dust-Tolerant Intelligent Electrical Connection System (10) Gigabit Ethernet Asynchronous Clock Compensation FIFO (11) High-Speed, Multi-Channel Serial ADC LVDS Interface for Xilinx Virtex-5 FPGA (12) Glovebox for GeoLab Subsystem in HDU1-PEM (13) Modified Process Reduces Porosity when Soldering in Reduced Gravity Environments (14) Use of Functionalized Carbon Nanotubes for Covalent Attachment of Nanotubes to Silicon (15) Flexible Plug Repair for Shuttle Wing Leading Edge (16) Three Dimensionally Interlinked, Dense, Solid Form of Single-Walled CNT Ropes (17) Axel Robotic Platform for Crater and Extreme Terrain Exploration (18) Site Tamper and Material Plow Tool - STAMP (19) Magnetic Interface for Segmented Mirror Assembly (20) Transpiration-Cooled Spacecraft-Insulation-Repair Fasteners (21) Fluorescence-Based Sensor for Monitoring Activation of Lunar Dust (22) Aperture Ion Source (23) Virtual Ultrasound Guidance for Inexperienced Operators (24) Model-Based Fault Diagnosis: Performing Root Cause and Impact Analyses in Real Time (25) Interactive Schematic Integration Within the Propellant System Modeling Environment (26) Magnetic and Electric Field Polarizations of Oblique Magnetospheric Chorus Waves (27) Variable Sampling Mapping.

Source record↗

The theoretical output of a ring core fluxgate sensor.

Demonstration that the output from a ring core sensor is directly proportional to the first time derivative of the product of dynamic permeability and magnetic intensity perturbation within the core caused by an external, uniform magnetic field. (Dynamic permeability is defined to be the slope of the hysteresis loop at a given point in time). Assuming that ellipsoidal shells can approximate the core, the demagnetization factor can be 'estimated' in the first order to be proportional to the first power of the quantity tape thickness (or number of wraps) divided by the core diameter. The constant of proportionality is determined from laboratory data. When an additional scale adjustment is applied to the resulting sensor output formula, the computed output tracks laboratory data for a range of sensor geometries.

Burger, J. R.↗

The magnetic field investigation on the Ulysses mission - Instrumentation and preliminary scientific results

A fundamental feature of the heliosphere is the three-dimensional structure of the interplanetary magnetic field. The magnetic field investigation on Ulysses, the first space probe to explore the out-of-ecliptic and polar heliosphere, aims at determining the large-scale features and gradients of the field, as well as the heliolatitude dependence of interplanetary phenomena so far only observed near the ecliptic plane. The Ulysses magnetometer uses two sensors, one a Vector Helium Magnetometer, the other a Fluxgate Magnetometer. Onboard data processing yields measurements of the magnetic field vector with a time resolution up to 2 vectors/second and a sensitivity of about 10 pT. Since the switch-on of the instrument in flight on 25 October 1990, a steady stream of observations has been made, indicating that at this phase of the solar cycle the field is generally disturbed: several shock waves and a large number of discontinuities have been observed, as well as several periods with apparently intense wave activity. The paper gives a brief summary of the scientific objectives of the investigation, followed by a detailed description of the instrument and its characteristics. Examples of wave bursts, interplanetary shocks and crossings of the heliospheric current sheet are given to illustrate the observations made with the instrument.

Balogh, A.↗

Functional metal–organic frameworks as effective sensors of gases and volatile compounds

Developing efficient sensor materials with superior performance for selective, fast and sensitive detection of gases and volatile organic compounds (VOCs) is essential for human health and environmental protection, through monitoring indoor and outdoor air pollutions, managing industrial processes, controlling food quality and assisting early diagnosis of diseases. Metal–organic frameworks (MOFs) are a unique type of crystalline and porous solid material constructed from metal nodes (metal ions or clusters) and functional organic ligands. They have been investigated extensively for possible use as high performance sensors for the detection of many different gases and VOCs in recent years, due to their large surface area, tunable pore size, functionalizable sites and intriguing properties, such as electrical conductivity, magnetism, ferroelectricity, luminescence and chromism. The high porosity of MOFs allows them to interact strongly with various analytes, including gases and VOCs, thus resulting in easily measurable responses to different physicochemical parameters. Although much of the recent work on MOF-based luminescent sensors have been summarized in several excellent reviews (up to 2018), a comprehensive overview of these materials for sensing gases and VOCs based on chemiresistive, magnetic, ferroelectric, and colorimertic mechanisms is missing. In this review, we highlight the most recent progress in developing MOF sensing and switching materials with an emphasis on sensing mechanisms based on electricity, magnetism, ferroelectricity and chromism. We provide a comprehensive analysis on the MOF–analyte interactions in these processes, which play a key role in the sensing performance of the MOF-based sensors and switches. We discuss in detail possible applications of MOF-based sensing and switching materials in detecting oxygen, water vapor, toxic industrial gases (such as hydrogen sulfide, ammonia, sulfur dioxide, nitrous oxide, carbon oxides and carbon disulfide) and VOCs (such as aromatic and aliphatic hydrocarbons, ketones, alcohols, aldehydes, chlorinated hydrocarbons and N,N'-dimethylformamide). Altogether, this review serves as a timely source of information and provides insight for the future development of advanced MOF materials as next-generation gas and VOC sensors.

36 MATERIALS SCIENCE↗