Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MASS RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Pioneer Venus large probe neutral mass spectrometer

The Pioneer Venus large probe neutral mass spectrometer (LNMS) uses a single focusing magnetic sector field mass analyzer with mass range of 1-208 amu, resolution sufficient to separate the mercury isotopes, and sensitivity sufficient to detect minor constituents in the 1 ppm range relative to the CO2 in the Venus atmosphere. A combination of ion and chemical pumping is used to maintain a vacuum in the mass analyzer and to remove the atmosphere gases which enter the ion source chamber through a special leak. A microprocessor controls the operation of the instrument through a highly efficient peak stepping and data compression program, permitting acquisition of a complete mass spectrum roughly once each minute.

Hoffman, J. H.↗

A survey of mass-loss effects in early-type stars

Intermediate-resolution data obtained with the Copernicus satellite are surveyed in order to define the region in the H-R diagram where mass loss occurs. The survey includes 40 stars, providing good coverage of supergiants from O4 to A2 and main-sequence stars from O4 to B7 as well as spotty coverage of late O giants and intermediate to late B stars. The spectral transitions examined are primarily resonance lines of ions of abundant elements plus some lines arising from excited states (e.g., C III at 1175.7 A and Si IV at 1122.5 A). Observed P Cygni profiles are discussed along with interesting features of some individual profiles. The data are shown to indicate that mass-loss effects occur over a wide portion of the H-R diagram, that mass ejection generally occurs when the holometric magnitude is greater than -6.0, and that the mass-ejection rate is usually high enough to produce P Cygni profile whenever the N V feature at 1240 A is present in a spectrum.

Snow, T. P., Jr.↗

Lunar observer laser altimeter

Understanding the global topography of the Moon is especially important for answering questions concerning lunar origin and evolution. Many outstanding problems in lunar science can be addressed with high resolution topographic data. The severe power, mass, size, and data-rate limitations imposed by the Lunar Geoscience Observer (LGO) and other Observer-class missions are major challenges for all instruments capable of measuring topography. A radar altimeter that meets these strict requirements could obtain a global prespective of lunar topography with a few kilometers spatial resolution and 10 m vertical resolution from a lunar orbit of 100 km. A prototype model is being constructed of the Lunar Observer Laser Altimeter (LOLA) capable of continuously measuring the range to the lunar surface with sub-meter vertical resolution within a 30 to 300 m diameter surface footprint. This same instrument is also designed to provide a direct measure of the surface height distribution in the footprint by waveform analysis of the backscattered laser pulse. Both these measurements are to be made in a continuous, nadir profile across the lunar surface from a 100 km orbit. The wavelength of the altimeter is 1064 nm. A short-pulse (2 nsec), diode-pumped Nd:YAG laser combined with a 25 cm diameter telescope, silicon avalanche photodiode detector, ranging electronics, and instrument computer was designed to make these measurements and meet all the requirements of the LGO mission.

Bufton, J. L.↗

Next Generation X-Ray Optics: High-Resolution, Light-Weight, and Low-Cost

X-ray telescopes are essential to the future of x-ray astronomy. This paper describes a comprehensive program to advance the technology for x-ray telescopes well beyond the state of the art represented by the three currently operating missions: Chandra, XMM-Newton , and Suzaku . This program will address the three key issues in making an x-ray telescope: (I) angular resolution, (2) effective area per unit mass, and (3) cost per unit effective area. The objectives of this technology program are (1) in the near term, to enable Explorer-class x-ray missions and an IXO type mission, and (2) in the long term, to enable a flagship x-ray mission with sub-arcsecond angular resolution and multi-square-meter effective area, at an affordable cost. We pursue two approaches concurrently, emphasizing the first approach in the near term (2-5 years) and the second in the long term (4-10 years). The first approach is precision slumping of borosilicate glass sheets. By design and choice at the outset, this technique makes lightweight and low-cost mirrors. The development program will continue to improve angular resolution, to enable the production of 5-arcsecond x-ray telescopes, to support Explorer-class missions and one or more missions to supersede the original IXO mission. The second approach is precision polishing and light-weighting of single-crystal silicon mirrors. This approach benefits from two recent commercial developments: (1) the inexpensive and abundant availability of large blocks of mono crystalline silicon, and (2) revolutionary advances in deterministic, precision polishing of mirrors. By design and choice at the outset, this technique is capable of producing lightweight mirrors with sub-arcsecond angular resolution. The development program will increase the efficiency and reduce the cost of the polishing and the lightweighting processes, to enable the production of lightweight sub-arcsecond x-ray telescopes. Concurrent with the fabrication of lightweight mirror segments is the continued development and perfection of alignment and integration techniques, for incorporating individual mirror segments into a precision mirror assembly. Recently, we have been developing a technique called edge-bonding, which has achieved an accuracy to enable 10- arcsecond x-ray telescopes. Currently, we are investigating and improving the long-term alignment stability of so-bonded mirrors. Next, we shall refine this process to enable 5-arsecond x-ray telescopes. This technology development program includes all elements to demonstrate progress toward TRL-6: metrology; x-ray performance tests; coupled structural, thermal, and optical performance analysis, and environmental testing.

Zhang, William W.↗

Next Generation X-Ray Optics: High-Resolution, Light-Weight, and Low-Cost

X-ray telescopes are essential to the future of x-ray astronomy. In this talk I will describe a comprehensive program to advance the technology for x-ray telescopes well beyond the state of the art represented by the three currently operating missions: Chandra, XMM-Newton, and Suzaku. This program will address the three key issues in making an x-ray telescope: (1) angular resolution, (2) effective area per unit mass, and (3) cost per unit effective area. The objectives of this technology program are (1) in the near term, to enable Explorer-class x-ray missions and an IXO-type mission, and (2) in the long term, to enable a flagship x-ray mission with sub-arcsecond angular resolution and multi-square-meter effective area, at an affordable cost. We pursue two approaches concurrently, emphasizing the first approach in the near term (2-5 years) and the second in the long term (4-10 years). The first approach is precision slumping of borosilicate glass sheets. By design and choice at the outset, this technique makes lightweight and low-cost mirrors. The development program will continue to improve angular resolution, to enable the production of 5-arcsecond x-ray telescopes, to support Explorer-class missions and one or more missions to supersede the original IXO mission. The second approach is precision polishing and light-weighting of single-crystal silicon mirrors. This approach benefits from two recent commercial developments: (1) the inexpensive and abundant availability of large blocks of monocrystalline silicon, and (2) revolutionary advances in deterministic, precision polishing of mirrors. By design and choice at the outset, this technique is capable of producing lightweight mirrors with sub-arcsecond angular resolution. The development program will increase the efficiency and reduce the cost of the polishing and the light-weighting processes, to enable the production of lightweight sub-arcsecond x-ray telescopes. Concurrent with the fabrication of lightweight mirror segments is the continued development and perfection of alignment and integration techniques, for incorporating individual mirror segments into a precision mirror assembly. Recently, we have been developing a technique called edge-bonding, which has achieved an accuracy to enable 10-arcsecond x-ray telescopes. Currently, we are investigating and improving the long-term alignment stability of so-bonded mirrors. Next, we shall refine this process to enable 5-arsecond x-ray telescopes. This technology development program includes all elements to demonstrate progress toward TRL-6: metrology; x-ray performance tests; coupled structural, thermal, and optical performance analysis, and environmental testing.

Zhang, William W.↗

iMaNGA: mock MaNGA galaxies based on IllustrisTNG and MaStar SSPs – II. The catalogue

ABSTRACT Strengthening the synergy between simulations and observations is essential to test galaxy formation and evolution theories. To achieve this goal, in the first paper of this series, we presented a method to generate mock SDSS-IV/Mapping Nearby Galaxies at Apache Point Observatory (MaNGA) integral-field spectroscopic galaxy observations from cosmological simulations. In this second paper, we build the iMaNGA catalogue consisting of ∼1000 unique galaxies from the TNG50 cosmological simulations, selected to mimic the SDSS-IV/MaNGA-Primary sample selection. Here, we present and discuss the iMaNGA sample and its comparison to the MaNGA Primary catalogue. The iMaNGA sample well recovers the MaNGA-Primary sample in terms of stellar mass versus angular size relation and spatial resolution. The Sérsic index versus angular size relation, instead, is not reproduced well by the simulations, mostly because of a paucity of high-mass elliptical galaxies in TNG50. We also investigate our ability to recover the galaxy kinematics and stellar population properties with full-spectral fitting. We demonstrate that ‘intrinsic’ and ‘recovered’ stellar kinematics, stellar ages, and metallicities are consistent, with residuals compatible with zero within 1σ. Also ‘intrinsic’ and ‘recovered’ star formation histories display a great resemblance. We conclude that our mock generation and spectral fitting processes do not distort the ‘intrinsic’ galaxy properties. Therefore, in the third paper of this series, we can meaningfully test the cosmological simulations, comparing the stellar population properties and kinematics of the iMaNGA mock galaxies and the MaNGA observational results.

79 ASTRONOMY AND ASTROPHYSICS↗

Mass density and pressure changes across the dayside magnetopause

Plasma composition measurements at about 2-min time resolution from 27 magnetopause crossings are used to determine if mass density rho, modified by the anisotropic pressure term (1-alpha), is constant across the magnetopause. Pressure and mass density in the magnetosheath and low-latitude boundary layer were found to be dominated by H(+) except on one occasion when O(+) was the dominant contributor to the total mass density in the low-latitude boundary layer. Using these measurements, it is found that rho(1-alpha) is not constant for almost all magnetopause crossings even when there is independent evidence for magnetic reconnection and an open magnetopause. These results indicate that the reason why rho(1-alpha) is not constant across the magnetopause is that the H(+) density decrease from the magnetosheath to the low-latitude boundary layer is not compensated for by either a change in the pressure anisotropy or a change in the total mass density and suggest that the magnetopause can never be described as a time-stationary 1D rotational discontinuity.

Fuselier, S. A.↗

Milky Way Satellite Census. IV. Constraints on Decaying Dark Matter from Observations of Milky Way Satellite Galaxies

Abstract We use a recent census of the Milky Way (MW) satellite galaxy population to constrain the lifetime of particle dark matter (DM). We consider two-body decaying dark matter (DDM) in which a heavy DM particle decays with lifetime τ comparable to the age of the universe to a lighter DM particle (with mass splitting ϵ ) and to a dark radiation species. These decays impart a characteristic “kick velocity,” V kick = ϵ c , on the DM daughter particles, significantly depleting the DM content of low-mass subhalos and making them more susceptible to tidal disruption. We fit the suppression of the present-day DDM subhalo mass function (SHMF) as a function of τ and V kick using a suite of high-resolution zoom-in simulations of MW-mass halos, and we validate this model on new DDM simulations of systems specifically chosen to resemble the MW. We implement our DDM SHMF predictions in a forward model that incorporates inhomogeneities in the spatial distribution and detectability of MW satellites and uncertainties in the mapping between galaxies and DM halos, the properties of the MW system, and the disruption of subhalos by the MW disk using an empirical model for the galaxy–halo connection. By comparing to the observed MW satellite population, we conservatively exclude DDM models with τ < 18 Gyr (29 Gyr) for V kick = 20 kms −1 (40 kms −1 ) at 95% confidence. These constraints are among the most stringent and robust small-scale structure limits on the DM particle lifetime and strongly disfavor DDM models that have been proposed to alleviate the Hubble and S 8 tensions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mass loss in M67 giants - Evidence from isochrone fitting

A comparison between the color-magnitude diagram of M67 and a new set of theoretical evolutionary models which include all phases from the unevolved main-sequence through core-helium burning and onto the AGB is presented. The present 5-Gyr solar abundance isochrone is found to yield an excellent fit to the whole of the M67 color-magnitude diagram. A differential technique that compares the gap in color between clump giants and normal red giants, on one hand, with the temperature gap between core He-burning tracks and first-ascent RGB tracks, on the other, strongly indicates that the clump giants in M67 have masses of 0.70 solar mass or less. The extremely large amount of mass loss that is deduced is well in excess of that found for globular cluster stars. Possible resolutions of this problem are that degree of mass loss increases with total stellar mass, or with metallicity.

Tripicco, Michael J.↗

Quantitative comparison of combined gas chromatographic/mass spectrometric profiles of complex mixtures

The paper describes a method called HISLIB for automatic quantitative comparison of gas chromatographic/mass spectrometric (GC/MS) results obtained on complex mixtures of organic compounds. The method is based on comparing new mixtures to 'historical' libraries of previous results. Co-occurrence of components is determined by matching relative retention indices (RRIs) and mass spectra after background removal and resolution of overlapping GC components. Internal standards are used to quantify the relative concentrations of components. Applications of HISLIB include validation of analytical procedures to isolate complex mixtures; development of historical libraries which might include complete summaries of all past observations, compilations of controls, or any other selected subset of results; improvement of the quality of existing libraries of mass spectral data; and detection of differences in kind and/or amounts of individual components. Limitations of the method are mentioned along with causes of their occurrence.

Smith, D. H.↗

Lunar mass spectrometer test program

The procedures used and the results are described, which were obtained in a test program to demonstrate the performance of a candidate lunar mass spectrometer. The instrument was designed to sample and measure gases believed to exist in the lunar atmosphere at the surface. The instrument consists of a cold cathode ion source, a small quadrupole mass analyzer, and an off-axis electron multiplier ion-counting detector. Instrument resolution, sensitivity, and S/N ratio were demonstrated over the mass range 0-150 amu and over a partial pressure range from ntorr to ptorr. The subject analyzer was also prepared for extended testing, in conjunction with two other candidate instruments, in a large molecular beam vacuum facility.

Torney, F. L.↗

High resolution measurements of nightside ion troughs at Venus - Evidence of electrodynamic perturbations

The Bennett rf ion mass spectrometer of the Pioneer Venus Orbiter was expressly designed to provide variable temporal resolution for measurements of thermal ion composition and density. The Explore-Adapt mode is used to obtain priority for measuring the most prominent ion species; in the 2/16 configuration, the two dominant ions within the available range of 16 species are selectively sampled at the highest rate of 0.2 sec/sample. The high-resolution measurements are combined with independent observations from the magnetic field, neutral mass spectrometer, and electron temperature experiments in investigating sharply structured troughs in the low-altitude nightside ion concentrations. The results suggest a close correlation between the structure in the ion distributions and the structured configuration of the magnetic field that is draped about the planet. In the regions of the ion depletions, sharp fluctuations in electron temperature and anomalous increases in the density of neutral gases suggest that the ion depletion may be associated with dynamic perturbation in the ion and neutral flows and/or local joule heating.

Taylor, H. A., Jr.↗

“Scrutinizing entrainment and mass flux closures in shallow cumulus parameterizations using cloud-radar observations and large-eddy simulation” (Final report for DOE grant)

Warm, shallow clouds are responsible for a substantial portion of Earth System Model (ESM) uncertainty and divergence among model climate projections. A substantial amount of this uncertainty is tied to the representation of convection in ESMs, in particular assumptions underlying the convective parameterizations. This study focuses on entrainment and entrainment closures in ESM parameterizations. The completed project was a joint observational and modeling study to observationally derive estimates of entrainment and to use high-resolution modeling to scrutinize entrainment and mass flux closures in shallow convection parameterizations.

58 GEOSCIENCES↗

MOS Circuitry Would Detect Low-Energy Charged Particles

Metal oxide semiconductor (MOS) circuits for measuring spatially varying intensities of beams of low-energy charged particles have been developed. These circuits are intended especially for use in measuring fluxes of ions with spatial resolution along the focal planes of mass spectrometers. Unlike prior mass spectrometer focal-plane detectors, these MOS circuits would not be based on ion-induced generation of electrons, and photons; instead, they would be based on direct detection of the electric charges of the ions. Hence, there would be no need for microchannel plates (for ion-to-electron conversion), phosphors (for electron-to-photon conversion), and photodetectors (for final detection) -- components that degrade spatial resolution and contribute to complexity and size. The developmental circuits are based on linear arrays of charge-coupled devices (CCDs) with associated readout circuitry (see figure). They resemble linear CCD photodetector arrays, except that instead of a photodetector, each pixel contains a capacitive charge sensor. The capacitor in each sensor comprises two electrodes (typically made of aluminum) separated by a layer of insulating material. The exposed electrode captures ions and accumulates their electric charges during signal-integration periods.

Sinha, Mahadeva↗

A Sensitive Quantitative Analysis of Abiotically Synthesized Short Homopeptides using Ultraperformance Liquid Chromatography and Time-of-Flight Mass Spectrometry

In the origins of life field understanding the abiotic polymerization of simple organic monomers (e.g., amino acids) into larger biomolecules (e.g., oligopeptides), remains a seminal challenge. Recently, preliminary observations showed a limited set of peptides formed in the presence of the plausible prebiotic phosphorylating agent, diamidophosphate (DAP), highlighting the need for an analytical tool to critically evaluate the ability of DAP to induce oligomerization of simple organics under aqueous conditions. However, performing accurate and precise, targeted analyses of short oligopeptides remains a distinct challenge in the analytical chemistry field. Here, we developed a new technique to detect and quantitate amino acids and their homopeptides in a single run using ultraperformance liquid chromatography-fluorescence detection/time of flight mass spectrometry. Over an 8-minute retention time window, 18 target analytes were identified and quantitated, 16 of which were chromatographically separated at, or near baseline resolution. Compound identity was confirmed by accurate mass analysis using a 10 ppm mass tolerance window. This method featured limits of detection < 5 nM (< 1 fmol on column) and limits of quantitation (LOQs) <15 nM (< 3 fmol on column). The LODs and LOQs were upwards of ∼28x and ∼788x lower, respectively, than previous methods for the same analytes, highlighting the quantifiable advantages of this new method. Both detectors provided good quantitative linearity (R(exp 2) > 0.985) for all analytes spanning concentration ranges ∼3 - 4 orders of magnitude. We performed a series of laboratory experiments to investigate DAP-mediated oligomerization of amino acids and peptides and analyzed experimental products with the new method. DAP readily polymerized amino acids and peptides under a range of simulated environmental conditions. This research underscores the potential of DAP to have generated oligopeptides on the primordial Earth, enhancing prebiotic chemical diversity and complexity at or near the origin of life.

Prebiotic Chemistry and Analytical Chemistry↗

A miniature high-resolution accelerometer utilizing electron tunneling

New methods have been developed to implement high-resolution position sensors based on electron tunneling. These methods allow miniaturization while utilizing the position sensitivity of electron tunneling to give high resolution. A single-element tunneling accelerometer giving a displacement resolution of 0.002 A/sq rt Hz at 10 Hz, corresponding to an acceleration resolution of 5 x 10 exp -8 g/sq rt Hz, is described. A new dual-element tunneling structure which overcomes the narrow bandwidth limitations of a single-element structure is described. A sensor with an operating range of 5 Hz to 10 kHz, which can have applications as an acoustic sensor, is discussed. Noise is analyzed for fundamental thermal vibration of the suspended masses and is compared to electronic noise. It is shown that miniature tunnel accelerometers can achieve resolution such that thermal noise in the suspended masses is the dominant cause of the resolution limit. With a proof mass of order 100 mg, noise analysis predicts limiting resolutions approaching 10 exp -9 g/sq rt Hz in a 300 Hz band and 10 exp -8 g/sq rt Hz at 1 kHz.

Rockstad, Howard K.↗

MISTiC Winds, a Micro-Satellite Constellation Approach to High Resolution Observations of the Atmosphere Using Infrared Sounding and 3D Winds Measurements

MISTiC(TM) Winds is an approach to improve short-term weather forecasting based on a miniature high resolution, wide field, thermal emission spectrometry instrument that will provide global tropospheric vertical profiles of atmospheric temperature and humidity at high (3-4 km) horizontal and vertical ( 1 km) spatial resolution. MISTiCs extraordinarily small size, payload mass of less than 15 kg, and minimal cooling requirements can be accommodated aboard a 27U-class CubeSat or an ESPA-Class micro-satellite. Low fabrication and launch costs enable a LEO sunsynchronous sounding constellation that would collectively provide frequent IR vertical profiles and vertically resolved atmospheric motion vector wind observations in the troposphere. These observations are highly complementary to present and emerging environmental observing systems, and would provide a combination of high vertical and horizontal resolution not provided by any other environmental observing system currently in operation. The spectral measurements that would be provided by MISTiC Winds are similar to those of NASA's AIRS that was built by BAE Systems and operates aboard the AQUA satellite. These new observations, when assimilated into high resolution numerical weather models, would revolutionize short-term and severe weather forecasting, save lives, and support key economic decisions in the energy, air transport, and agriculture arenasat much lower cost than providing these observations from geostationary orbit. In addition, this observation capability would be a critical tool for the study of transport processes for water vapor, clouds, pollution, and aerosols. Key remaining technical risks are being reduced through laboratory and airborne testing under NASA's Instrument Incubator Program.

Maschhoff, K. R.↗

Physical Nature of the Eclipsing δ Scuti Star AO Serpentis

We present the absolute properties of the eclipsing binary AO Ser with a pulsating component from our BV photometric and high-resolution spectroscopic observations, which were performed between 2017 April and May. The radial velocities (RVs) for both components were measured, and the effective temperature and projected rotational velocity of the primary star were determined to be T eff,1 = 8,820 ± 62 K and v 1 sini 1 = 90 ± 18 km s -1 , respectively, by comparing the observed spectrum with the Kurucz models. The accurate fundamental parameters of AO Ser were determined by a simultaneous analysis of the light and RV curves. The masses and radii of the primary and secondary components are M 1 = 2.55 ± 0.09 M ⊙ and R 1 = 1.64 ± 0.02 R ⊙ and M 2 = 0.49 ± 0.02 M ⊙ and R 2 = 1.38 ± 0.02 R ⊙ , respectively. Multiple frequency analyses for the eclipse-subtracted light residuals were conducted. As a result, we detected two frequencies of f 1 = 21.852 days -1 and f 2 = 23.484 days -1 . The evolutionary position on the HR diagram and the pulsational characteristics indicate that the primary star is a δ Sct pulsator with a radial fundamental mode. On the other hand, the relatively evolved secondary is oversized for its own mass.

79 ASTRONOMY AND ASTROPHYSICS↗