Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Low temperature detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Extending the dark matter reach of water Cherenkov detectors using Jupiter

We propose the first method for water Cherenkov detectors to constrain GeV-scale dark matter (DM) below the solar evaporation mass. While previous efforts have highlighted the Sun and Earth as DM capture targets, we demonstrate that Jupiter is a viable target. Jupiter’s unique characteristics, such as its lower core temperature and significant gravitational potential, allow it to capture and retain light DM more effectively than the Sun, particularly in the mass range below 4 GeV where direct detection sensitivity diminishes. Our calculations provide the first sensitivity estimates to GeV-scale annihilating DM within Jupiter, predicting Hyper-K can reach spin dependent cross sections as low as $𝜎^{SD}_{𝑝⁢𝜒}$ = 2×10 −35 cm 2 for DM masses below 2 GeV. This surpasses current solar limits and direct detection results. We additionally provide estimates for Super-K ORCA, and the IceCube-Upgrade, showing that these experiments could provide complimentary bounds to direct detection experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

NASA Space Cryocooler Programs: A 2003 Overview

Mechanical cryocoolers represent a significant enabling technology for NASA's Earth and Space Science missions. An overview is presented of ongoing cryocooler activities within NASA in support of current flight projects, near-term flight instruments, and long-term technology development. NASA programs in Earth and space science observe a wide range of phenomena, from crop dynamics to stellar birth. Many of the instruments require cryogenic refrigeration to improve dynamic range, extend wavelength coverage, and enable the use of advanced detectors. Although, the largest utilization of coolers over the last decade has been for instruments operating at medium to high cryogenic temperatures (55 to 150 K), reflecting the relative maturity of the technology at these temperatures, important new developments are now focusing at the lower temperature range from 4 to 20 K in support of studies of the origin of the universe and the search for planets around distant stars. NASA's development of a 20K cryocooler for the European Planck spacecraft and its new Advanced Cryocooler Technology Development Program (ACTDP) for 6-18 K coolers are examples of the thrust to provide low temperature cooling for this class of missions.

Ross, R. G., Jr.↗

Development of Ultra-High Sensivity Silicon Carbide Detectors

A variety of silicon carbide (SiC) detectors have been developed to study the sensitivity of SiC ultraviolet (UV) detectors, including Schottky photodiodes, p-i-n photodiodes, avalanche photodiodes (APDs), and single photon-counting APDs. Due to the very wide bandgap and thus extremely low leakage current, Sic photo-detectors showed excellent sensitivity. The specific detectivity, D*, of SiC photodiodes are orders of magnitude higher than that of their competitors, such as Si photodiodes, and comparable to the D* of photomultiplier tubes (PMTs). To pursue the ultimate detection sensitivity, SiC APDs and single photon-counting avalanche diodes (SPADs) have also been fabricated. By operating the SiC APDs at a linear mode gain over 10(exp 6), SPADs in UV have been demonstrated. SiC UV detectors have great potential for use in solar blind UV detection and biosensing. Moreover, SiC detectors have excellent radiation hardness and high temperature tolerance which makes them ideal for extreme environment applications such as in space or on the surface of the Moon or Mars.

Yan, Feng↗

Investigation of large format microchannel plate Z configurations

The performance of triplet (Z) stacks of microchannel plates (MCPs) has been studied as a part of the instrument development for the Extreme Ultraviolet Explorer (EUVE) satellite mission. Relatively large MCPs with a 60-mm diameter and having a large 80:1 channel length to diameter (L:D) ratio were used in several configurations. The MCPs were used in the EUVE prototype imaging detector to provide more than 512 x 512 pixels with low image distortion (less than 1 percent). The gain and pulse height characteristics of the MCPs were examined, showing that both high gains (more than 2 x 10 to the 7th) and tight output pulse height distributions (less than 30 percent FWHM) may be achieved. Simple distribution techniques have also allowed low intrinsic background event rates (less than 0.15 events per sq cm/s) to be obtained. Variation of the quantum efficiency of the MCPs over the wavelength range 160-1216 A has been investigated for a range of angles of incidence. The effect of temperature variations on MCP operating characteristics has also been evaluated.

Siegmund, O. H. W.↗

Anisotropy in the microwave sky at intermediate angular scales

Observations of a low-background region of sky at high Galactic latitude in a frequency band centered at nu = 90 GHz reveal highly significant detections of anisotropy on intermediate (aprroximately 1 deg) angular scales. The instrument is a 2 x 2 array of bolometric detectors operating at 50 mK, coupled to a 0.75 m off-axis parabolic telescope by single-mode corrugated feedhorns. The FWHM beamwidth of the instrument is 0.75 deg, with a beamswitch of +/- 2.75 deg on the sky. Interpreting the detected fluctuations as due to anisotropy in the cosmic microwave background, a likelihood analysis assuming a Gaussian correlation function in the temperature fluctuations yields most likely values of (delta T)/T of 3.1(sub -0.9)(sup +2.5) x 10(exp -5) and 3.8(sub -1.2)(sup +2.9) x 10(exp -5) at a coherence angle of 1.0 deg, for the left- and right-hand detectors, respectively. The stated errors are 95% confidence limits. Confirmation at other frequencies is required to rule out the possibility of foreground contamination.

Dragovan, M.↗

RadLab and the Environmental Data Application Dashboard: Graphical and Programming Interfaces for Interrogation of Space Telemetry Data

Sensors on the International Space Station (ISS) and multiple spacecraft elsewhere in Earth orbit and in deep space continuously monitor and collect environmental data, transmitting this information back to Earth. These data include ionizing radiation and, on the ISS, CO2, relative humidity levels, and temperature, and are of great importance to space biology research. Ionizing radiation in particular has been established in ground-based experiments as being correlated with increased risk of carcinogenesis and cardiovascular and neurological effects. Looking ahead to future long duration crewed missions beyond low Earth orbit, the ability to study how factors including CO2 levels, light cycle, temperature modulate the response to ionizing radiation and microgravity is essential. To date, access to these data has been fragmented across space agencies, spacecraft, and databases. To address this issue, NASA’s Open Science Data Repository (osdr.nasa.gov) has developed two Web applications: the Environmental Data Application (EDA) and a radiation-specific RadLab. Each consists of an API (application programming interface) and an associated GUI (graphical user interface) that provide single points of access to the data. To date, OSDR has focused on the sensors from payloads and radiation detectors located on the ISS. The Web applications process telemetry information and associated data, such as spacecraft location and orientation, from multiple international databases. The applications’ request syntax enables users to interrogate these data by craft, sensor type, time range, radiation type (galactic cosmic rays, solar particle events, the contribution of the South Atlantic Anomaly), facilitating arbitrary comparisons of original source data at varying time resolutions. The applications provide programmatic access for use in computational pipelines and GUIs for data visualization and exploration, making these data FAIR (Findable, Accessible, Interoperable, and Reusable), complementing the biological data contained in OSDR, and providing the space science community with a valuable resource for scientific analyses.

radiation↗

Transient response of Ge:Be and Ge:Zn FIR photoconductors under low background photon flux conditions

An experimental study of the transient behavior of Ge:Be and Ge:Zn photoconductors to changes in photon flux rates has been performed under the low background flux conditions (10 to the 8th photon/s) typical of astronomy and astrophysics applications. A characteristic transient behavior with time constants ranging from 0.1 to greater than 5 s has been observed in both materials when the shallow levels are very closely compensated. The detector response consists of both a fast and a slow component. The amplitude of the slow component can be up to 10 times greater than the initial fast component. It has been established that this phenomenon cannot be explained by current models of carrier sweep-out or dielectric relaxation. The transient behavior has been characterized as a function of temperature, electric field, photoconductive gain and material parameters.

Haegel, N. M.↗

KIPM Detector Characterization in QUIET

Kinetic Inductance Phonon‑Mediated (KIPM) detectors are superconducting microwave resonators that sense energy depositions in the substrate through a transient shift in their resonant frequency. In this work, I installed new devices in the QUIET cryogenic facility and used a network analyzer to drive them across a range of power levels. At each setting, I measured the transmitted signal and fit it to a simple notch‑filter model, allowing us to extract key performance metrics. Despite the increased noise at low power, the model consistently captured the resonance behavior. I first measured the resonance parameters as a function of RF drive power, then repeated the measurement across a range of temperatures to test whether the device behaved like an MKID. While the notch-filter fits captured the resonance reliably, the observed temperature dependence did not match the expected MKID signature — indicating that these first in-house fabricated chips are not yet functioning as true MKIDs. Overall, this reframes our work as a study of resonance parameter extraction and identification, pointing towards future iterations of device design and fabrication to get the true MKID response.

Savitala, Akash [U. Washington, Seattle (main); Fe↗

New insight in the solar T(sub MIN) region from the CO lines at 4.67 micron

We discuss recent observations of the fundamental vibration-rotation transitions of carbon monoxide (CO) in the solar infrared spectrum. Employing a new array detector at the McMath-Pierce facility on Kitt Peak we find that the CO lines sketch a rich picture of the dynamics of the solar temperature minimum region, the lower boundary of the chromosphere. In a spectra-spectroheliogram and a time-sequence of the slit-spectra obtained during exceptional seeing conditions we observe small-scale bright, ring shaped, blueshifted features. We speculate that they are the signature of granular overshoot into the convectively stable temperature minimum. The centers of the rings are among the coolest elements seen in strong CO-line heliograms on the disk, and may be instrumental to the low temperature observed in CO close to the solar limb.

Uitenbroek, Han↗

High Accuracy Temperature Measurements Using RTDs with Current Loop Conditioning

To measure temperatures with a greater degree of accuracy than is possible with thermocouples, RTDs (Resistive Temperature Detectors) are typically used. Calibration standards use specialized high precision RTD probes with accuracies approaching 0.001 F. These are extremely delicate devices, and far too costly to be used in test facility instrumentation. Less costly sensors which are designed for aeronautical wind tunnel testing are available and can be readily adapted to probes, rakes, and test rigs. With proper signal conditioning of the sensor, temperature accuracies of 0.1 F is obtainable. For reasons that will be explored in this paper, the Anderson current loop is the preferred method used for signal conditioning. This scheme has been used in NASA Lewis Research Center's 9 x 15 Low Speed Wind Tunnel, and is detailed.

Hill, Gerald M.↗

The Extreme Ultraviolet Normal Incidence Spectrograph (EUNIS)

EUNIS (Extreme Ultraviolet Normal Incidence Spectrograph) is a high-efficiency extreme ultraviolet spectrometer that is expected to fly for the first time in 2004 as a sounding rocket payload. Using two independent optical systems, EUNIS will probe the structure and dynamics of the inner solar corona high spectral resolution in two wavelength regions: 17-21 nm with 3.5 pm resolution and 30-37 nm with 7 pm resolution. The long wavelength channel includes He II 30.4 nm and strong lines from Fe XI-XVI; the short wavelength channel includes strong lines of Fe IX-XIII. Angular resolution of 2 arcsec is maintained along a slit covering a full solar radius. EUNIS will have 100 times the throughput of the highly successful SERTS payloads that have preceded it. There are only two reflections in each optical channel, from the superpolished, off-axis paraboloidal primary and the toroidal grating. Each optical element is coated with a high-efficiency multilayer coating optimized for its spectral bandpass. The detector in each channel is a microchannel plate image intensifier fiber- coupled to three 1K x 1K active pixel sensors. EUNIS will obtain spectra with a cadence as short as 1 sec, allowing unprecedented studies of the physical properties of evolving and transient structures. Diagnostics of wave heating and reconnection wil be studied at heights above 2 solar radii, in the wind acceleration region. The broad spectral coverage and high spectral resolution will provide superior temperature and density diagnostics and will enable underflight calibration of several orbital instruments, including SOHO/CDS and EIT, TRACE, Solar-B/EIS, and STEREO/EUVI. EUNIS is supported by NASA through the Low Cost Access to Space Program in Solar and Heliospheric Physics.

Oegerle, William↗

In-flight radiation measurements on STS-60

A joint investigation between the United States and Russia to study the radiation environment inside the Space Shuttle flight STS-60 was carried out as part of the Shuttle-Mir Science Program (Phase 1). This is the first direct comparison of a number of different dosimetric measurement techniques between the two countries. STS-60 was launched on 3 February 1994 in a nearly circular 57 degrees x 353 km orbit with five U.S. astronauts and one Russian cosmonaut for 8.3 days. A variety of instruments provided crew radiation exposure, absorbed doses at fixed locations, neutron fluence and dose equivalent, linear energy transfer (LET) spectra of trapped and galactic cosmic radiation, and energy spectra and angular distribution of trapped protons. In general, there is good agreement between the U.S. and Russian measurements. The AP8 Min trapped proton model predicts an average of 1.8 times the measured absorbed dose. The average quality factor determined from measured lineal energy, y, spectra using a tissue equivalent proportional counter (TEPC), is in good agreement with that derived from the high temperature peak in the 6LiF thermoluminescent detectors (TLDs). The radiation exposure in the mid-deck locker from neutrons below 1 MeV was 2.53 +/- 1.33 microSv/day. The absorbed dose rates measured using a tissue equivalent proportional counter, were 171.1 +/- 0.4 and 127.4 +/- 0.4 microGy/day for trapped particles and galactic cosmic rays, respectively. The combined dose rate of 298.5 +/- 0.82 microGy/day is about a factor of 1.4 higher than that measured using TLDs. The westward longitude drift of the South Atlantic Anomaly (SAA) is estimated to be 0.22 +/- 0.02 degrees/y. We evaluated the effects of spacecraft attitudes on TEPC dose rates due to the highly anisotropic low-earth orbit proton environment. Changes in spacecraft attitude resulted in dose-rate variations by factors of up to 2 at the location of the TEPC.

NASA Discipline Radiation Health↗

Isolation Effects on the Moon: High Topographic Slope Observations from the LRO and LOLA Instruments

The extremely low temperatures in the Moon's polar permanent shadow regions (PSR) has long been considered a unique factor necessary for entrapping volatile Hydrogen (H). However, recent discoveries indicate some H concentrations lie outside PSR, suggesting other geophysical factors may also influence H distributions. In this study we consider insolation and its resulting thermal effects as a loss/redistribution process influencing the Moon's near-surface < 1m volatile H budget. To isolate regional (5deg latitude band) insolation effects we correlate two data sets collected from the ongoing, 1.5 year long mapping mission of the Lunar Reconnaissance Orbiter (LRO). Epithermal neutron mapping data from the Lunar Exploration Neutron Detector (LEND) is registered and analyzed in the context of slope derivations from Lunar topography maps produced by the Lunar Observing Laser Altimeter (LOLA). Lunar epithermal neutrons are inferred to be direct geochemical evidence for near-surface H due to the correlated suppression of surface leakage fluxes of epithermal neutrons with increased H concentration. Regional suppressions of neutrons seen in LEND maps are considered localized evidence of H concentration increase in the upper 1 m of the Lunar surface. To quantify spatially localized insolation effects, LEND data are averaged from sparsely distributed pixels, classed as a function of the LOLA slope derivations.

McClanahan, T. P.↗

Small Aperture Telescopes for the Simons Observatory

The Simons Observatory (SO) is an upcoming cosmic microwave background(CMB) experiment located on Cerro Toco, Chile, that will map the microwave sky in temperature and polarization in six frequency bands spanning 27 to 285 GHz. SO will consist of one 6-meter Large Aperture Telescope (LAT) fielding∼30,000 detectors and an array of three 0.42-meter Small Aperture Telescopes (SATs) fielding an additional 30,000 detectors. This synergy will allow for the extremely sensitive characterization of the CMB over an-gular scales ranging from an arcmin to tens of degrees, enabling a wide range of scientific output. Here we focus on the SATs targeting degree angular scales with successive dichroic instruments observing at Mid-Frequency (MF: 93/145 GHz), Ultra-High-Frequency (UHF:225/285 GHz), and Low-Frequency (LF: 27/39 GHz). The three SATs will be able to map∼10% of the sky to a noise level of∼2 μK-arcmin when combining 93 and 145 GHz. The multiple frequency bands will allow the CMB to be separated from galactic foregrounds (primarily synchrotron and dust), with the primary science goal of characterizing the primordial tensor-to-scalar ratio, r, at a target level ofσ(r)≈0.003.

Small aperature telescope↗

Low Cost Solar Array Project: Composition Measurements by Analytical Photo Catalysis

The applicability of the photon catalysis technique for effecting composition analysis of silicon samples is discussed. A detector for the impurities Al, Cr, Fe, Mn, Ti, V, Mo and Zr is evaluated. During the first reporting period Al, Cr, Fe, and Mn were detected with the photon catalysis method. The best fluorescence lines to monitor and determine initial sensitivities to each of these elements by atomic absorption calibration were established. In the course of these tests vapor pressure curves for these four pure substances were also mapped. Ti and Si were detected. The best lines to monitor were catalogued and vapor pressure curves were determined. Attempts to detect vanadium were unsuccessful due to the refractory nature of this element and the limited temperature range of the evaporator.

Sutton, D. G.↗

Comprehensive study of radon progeny attachment to surfaces

Low energy, low rate experiments, such as searches for neutrinoless double β decay and dark matter, require unprecedentedly low levels of background in order to deliver their full science potential. 210 Po driven, neutron induced background, caused by nuclear (α, n) reactions on low-Z materials, direct background contributions of the 210 Po α radiation and desorption of the 210 Pb progeny 210 Bi from surfaces into the detector medium are of particular of concern. These backgrounds depend on details of the components’ exposure to radon-loaded laboratory air and, thus, their handling history. The attachment rates of airborne radon progeny to surfaces, needed for the estimation of these background rates, are poorly understood. This article reports the results of a campaign comprising of more than 1200 attachment measurements, performed for nine different materials. Correlations of the attachment with environmental parameters such as air exchange rate, electrical surface potential, temperature, atmospheric pressure, and relative humidity have been studied and found to be significant only in case of the first two. Attachment modeling, using the Jacobi model, is compared to data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NASA Tech Briefs, March 2012

The topics include: 1) Spectral Profiler Probe for In Situ Snow Grain Size and Composition Stratigraphy; 2) Portable Fourier Transform Spectroscopy for Analysis of Surface Contamination and Quality Control; 3) In Situ Geochemical Analysis and Age Dating of Rocks Using Laser Ablation-Miniature Mass Spectrometer; 4) Physics Mining of Multi-Source Data Sets; 5) Photogrammetry Tool for Forensic Analysis; 6) Connect Global Positioning System RF Module; 7) Simple Cell Balance Circuit; 8) Miniature EVA Software Defined Radio; 9) Remotely Accessible Testbed for Software Defined Radio Development; 10) System-of-Systems Technology-Portfolio-Analysis Tool; 11) VESGEN Software for Mapping and Quantification of Vascular Regulators; 12) Constructing a Database From Multiple 2D Images for Camera Pose Estimation and Robot Localization; 13) Adaption of G-TAG Software for Validating Touch and Go Asteroid Sample Return Design Methodology; 14) 3D Visualization for Phoenix Mars Lander Science Operations; 15) RxGen General Optical Model Prescription Generator; 16) Carbon Nanotube Bonding Strength Enhancement Using Metal Wicking Process; 17) Multi-Layer Far-Infrared Component Technology; 18) Germanium Lift-Off Masks for Thin Metal Film Patterning; 19) Sealing Materials for Use in Vacuum at High Temperatures; 20) Radiation Shielding System Using a Composite of Carbon Nanotubes Loaded With Electropolymers; 21) Nano Sponges for Drug Delivery and Medicinal Applications; 22) Molecular Technique to Understand Deep Microbial Diversity; 23) Methods and Compositions Based on Culturing Microorganisms in Low Sedimental Fluid Shear Conditions; 24) Secure Peer-to-Peer Networks for Scientific Information Sharing; 25) Multiplexer/Demultiplexer Loading Tool (MDMLT); 26) High-Rate Data-Capture for an Airborne Lidar System; 27) Wavefront Sensing Analysis of Grazing Incidence Optical Systems; 28) Foam-on-Tile Damage Model; 29) Instrument Package Manipulation Through the Generation and Use of an Attenuated-Fluent Gas Fold; 30) Multicolor Detectors for Ultrasensitive Long-Wave Imaging Cameras; 31) Lunar Reconnaissance Orbiter (LRO) Command and Data Handling Flight Electronics Subsystem; and 32) Electro-Optic Segment-Segment Sensors for Radio and Optical Telescopes.

Source record↗

Development of far infrared detection techniques

This grant supports the development of a variety of advanced far infrared detection techniques that will be used in future NASA missions such as the Space Infrared Telescope Facility (SIRTF). These studies span the wavelength region of 30-200 microns and include development of focal planes and electronics that would utilize them. Efforts reported here represent collaborations among the University of Arizona's Steward Observatory; Lawrence Berkeley Laboratories (LBL); and the University of California at Berkeley. The overall goal of this program is to demonstrate extremely high performance detectors for low background applications between 30-200 microns. For the 40-120 micron region, the program is developing a 32x32 filled detector array. Previous work has demonstrated the required performance with a Z-Plane array architecture; we are now upgrading construction facilities and techniques to increase yields and reliability. We have completed the initial tradeoff analysis for the interconnects between the detectors and and readouts. We found satisfactory performance for both Flex-Cable and Tape Automated Bonding (TAB) devices, but analysis showed that an all-sapphire device would not meet our requirements. In addition, the effort continued to develop readouts that can operate close to the detector element temperature; success would substantially improve the manufacturability of the arrays. For the 100-200 micron range, previous work has demonstrated good performance with individual detector elements of stressed Ge:Ga; current efforts are to increase the quantum efficiency of these devices. Work continues to discover how to construct an alternate type of long wave detector, Ge:B Blocked Impurity Band devices. Following descoping of SIRTF, we are closing out the bolometer and refrigerator development. We documented the optical designs and approaches developed previously to meet the specific requirements of these detector types in terms of modulation of the signals for good photometric behavior within the constraints of a compact and self-contained cryogenic instrument. Further study was initiated for the Band 3 optical train, where we have concerns about complexity and the manufacturability of one component.

Rieke, George↗