Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Low Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Two-Stage Cryogenic HEMT-Based Amplifier for Low-Temperature Detectors

To search for dark matter candidates with masses below $\mathcal{O}$ (MeV), the SPLENDOR (Search for Particles of Light dark mattEr with Narrow-gap semiconDuctORs) experiment is developing novel narrow-bandgap semiconductors with electronic bandgaps on the order of 1–100 meV. In order to detect the charge signal produced by scattering or absorption events, SPLENDOR has designed a two-stage cryogenic HEMT-based amplifier with an estimated charge resolution approaching the single-electron level. A low-capacitance (~ 1.6 pF) HEMT is used as a buffer stage at T = 10 mK to mitigate effects of stray capacitance at the input. The buffered signal is then amplified by a higher-capacitance (~ 200 pF) HEMT amplifier stage at T = 4 K. Importantly, the design of this amplifier makes it usable with any insulating material—allowing for rapid prototyping of a variety of novel detector materials. Here, we present the two-stage cryogenic amplifier design, preliminary voltage noise performance, and estimated charge resolution of 7.2 electrons.

47 OTHER INSTRUMENTATION↗

Lidar-Based Evaluation of HRRR Performance in California’s Diablo Range

The performance of the NOAA High-Resolution Rapid Refresh (HRRR) model for capturing low-level winds near a wind energy production site during summer 2019 is evaluated. This study catalogs the ability of HRRR to predict boundary layer dynamics relevant to wind energy interests over complex terrain, which has presented challenges for weather and energy forecasting. Performance is evaluated by comparing HRRR output to wind-profiling Doppler lidars at Lawrence Livermore National Laboratory Site 300. HRRR captured the diurnal profile of horizontal winds in the observed 150-m layer, despite strong underpredictions (∼4 m s −1 ) during evening and nighttime hours. These underpredictions may be a result of local speedup flows observed by the lidars, which were unresolved in HRRR due to their small spatial extent. HRRR bias magnitude relative to observations was found to be minimal during days with synoptic-scale troughs and strong 850-hPa geopotential gradients, while bias magnitude was maximal during days with synoptic ridging and weak 850-hPa geopotential gradients. To translate wind speed predictions to energy forecasting, generic turbine models were used to estimate power generation for turbines characteristic of the nearby Altamont Pass Wind Resource Area. Results show that HRRR-based energy estimates predicted daytime power generation adequately relative to lidar-based estimates with an 18-h lead time (bias magnitude < 0.4 MW from 0900 to 1400 LT) but overpredicted power during the rest of the diurnal cycle (bias > 1 MW). These results demonstrate conditions under which HRRR performs well for wind energy applications in complex terrain, while highlighting biases that require further investigation to support usage of a high-resolution model for wind energy forecasts.

Boundary layer↗

Improving Stratocumulus Cloud Amounts in a 200‐m Resolution Multi‐Scale Modeling Framework Through Tuning of Its Interior Physics

Abstract High‐Resolution Multi‐scale Modeling Frameworks (HR)—global climate models that embed separate, convection‐resolving models with high enough resolution to resolve boundary layer eddies—have exciting potential for investigating low cloud feedback dynamics due to reduced parameterization and ability for multidecadal throughput on modern computing hardware. However low clouds in past HR have suffered a stubborn problem of over‐entrainment due to an uncontrolled source of mixing across the marine subtropical inversion manifesting as stratocumulus dim biases in present‐day climate, limiting their scientific utility. We report new results showing that this over‐entrainment can be partly offset by using hyperviscosity and cloud droplet sedimentation. Hyperviscosity damps small‐scale momentum fluctuations associated with the formulation of the momentum solver of the embedded large eddy simulation. By considering the sedimentation process adjacent to default one‐moment microphysics in HR, condensed phase particles can be removed from the entrainment zone, which further reduces entrainment efficiency. The result is an HR that can produce more low clouds with a higher liquid water path and a reduced stratocumulus dim bias. Associated improvements in the explicitly simulated sub‐cloud eddy spectrum are observed. We report these sensitivities in multi‐week tests and then explore their operational potential alongside microphysical retuning in decadal simulations at operational 1.5° exterior resolution. The result is a new HR having desired improvements in the baseline present‐day low cloud climatology, and a reduced global mean bias and root mean squared error of absorbed shortwave radiation. We suggest it should be promising for examining low cloud feedbacks with minimal approximation.

54 ENVIRONMENTAL SCIENCES↗

Hardware Selection and Performance of Low-Cost Fluorometers

Access to and extensive use of fluorometric analyses is limited, despite its extensive utility in environmental transport and fate. Wide-spread application of fluorescent tracers has been limited by the prohibitive costs of research-grade equipment and logistical constraints of sampling, due to the need for high spatial resolutions and access to remote locations over long timescales. Recently, low-cost alternatives to research-grade equipment have been found to produce comparable data at a small fraction of the price for commercial equipment. Here, we prototyped and benchmarked performance of a variety of fluorometer components against commercial units, including performance as a function of tracer concentration, turbidity, and temperature, all of which are known to impact fluorometer performance. While component performance was found to be comparable to the commercial units tested, the best configuration tested obtained a functional resolution of 0.1 ppb, a working concentration range of 0.1 to >300 ppb, and a cost of USD 59.13.

42 ENGINEERING↗

Skipper Charge-Coupled Device for Low-Energy-Threshold Particle Experiments above Ground

Here we present experimental results using a single-electron resolution skipper CCD running above ground level to demonstrate the potential of this technology for its use in reactor neutrino observations and other low-energy particle-interaction experiments. Operating conditions and event-selection criteria are provided to decouple most of the background rate at low energies. The majority of this background comes from interactions in the inactive silicon surrounding the active detector volume that ends up in the readout register of the sensor. Our final results are compared with other low-threshold technologies showing a good control of the background for low ionization energies down to five electron-hole pairs. This demonstrates that the skipper CCD proves to be among the best options to measure low-energy and weakly interacting particles at ground level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On the numerical accuracy in finite-volume methods to accurately capture turbulence in compressible flows

The goal of the present article is to understand the impact of numerical schemes for the reconstruction of data at cell faces in finite-volume methods, and to assess their interaction with the quadrature rule used to compute the average over the cell volume. Here, third-, fifth- and seventh-order WENO-Z schemes are investigated. On a problem with a smooth solution, the theoretical order of convergence rate for each method is retrieved, and changing the order of the reconstruction at cell faces does not impact the results, whereas for a shock-driven problem all the methods collapse to first-order. Here, study of the decay of compressible homogeneous isotropic turbulence reveals that using a high-order quadrature rule to compute the average over a finite-volume cell does not improve the spectral accuracy and that all methods present a second-order convergence rate. However the choice of the numerical method to reconstruct data at cell faces is found to be critical to correctly capture turbulent spectra. In the context of simulations with finite-volume methods of practical flows encountered in engineering applications, it becomes apparent that an efficient strategy is to perform the average integration with a low-order quadrature rule on a fine mesh resolution, whereas high-order schemes should be used to reconstruct data at cell faces.

97 MATHEMATICS AND COMPUTING↗

Examining phase separation and crystallization in glasses with X-ray nano-computed tomography

X-ray nano-computed tomography (nano-CT) is a powerful technique to characterize and visualize 3 dimensional (3D) phenomena in complex glasses at the nanoscale. This technique can offer a unique opportunity to explore the intricate morphology of multicomponent glass and glass-ceramic samples, due to its low X-ray energy and high spatial resolution (down to 50 nm). In the current demonstration paper, nano-CT provided insight into crystallization and phase separation, as well as a variety of other phenomena, including corrosion, fracture, and porosity. At scales ranging from 100 to 20 μm, the microstructures of phase separation in borosilicate, complex silicate, and chalcogenide glass compositions were examined. In addition, crystallites present in simulant nuclear waste glasses, volcanic glasses, and other related samples were explored. Nano-CT analysis can add to the understanding of (1) the formation processes, (2) distributions, interactions, and compositions of phases, and (3) the mechanisms, structures, and growth of crystallization and phase separation. Nano-CT offers wide potential in the field of glass science, especially when (1) common characterization methods are insufficient, (2) simple sample preparation is required, (3) 3D rendering is needed, or (4) compelling images of small, complex features are desired.

36 MATERIALS SCIENCE↗

Temperature-dependent charge barrier height of amorphous germanium contact detector

The exploration of germanium (Ge) detectors with amorphous Ge (a-Ge) contacts has drawn attention to the searches for rare-event physics such as dark matter and neutrinoless double-beta decay. The charge barrier height (CBH) of the a-Ge contacts deposited on the detector surface is crucial to suppress the leakage current of the detector in order to achieve a low-energy detection threshold and high-energy resolution. The temperature-dependent CBH of a-Ge contacts for three Ge detectors is analyzed to study the bulk leakage current (BLC) characteristics. The detectors were fabricated at the University of South Dakota using homegrown crystals. The CBH is determined from the BLC when the detectors are operated in the reverse bias mode with a guard-ring structure, which separates the BLC from the surface leakage current (SLC). Here the results show that CBH is temperature dependent. The direct relation of the CBH variation to temperature is related to the barrier inhomogeneities created on the interface of a-Ge and crystalline Ge. The inhomogeneities that occur at the interface were analyzed using the Gaussian distribution model for three detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlative montage parallel array cryo-tomography for in situ structural cell biology

Abstract Imaging large fields of view while preserving high-resolution structural information remains a challenge in low-dose cryo-electron tomography. Here we present robust tools for montage parallel array cryo-tomography (MPACT) tailored for vitrified specimens. The combination of correlative cryo-fluorescence microscopy, focused-ion-beam milling, substrate micropatterning, and MPACT supports studies that contextually define the three-dimensional architecture of cells. To further extend the flexibility of MPACT, tilt series may be processed in their entirety or as individual tiles suitable for sub-tomogram averaging, enabling efficient data processing and analysis.

59 BASIC BIOLOGICAL SCIENCES↗

Near-infrared C-term MCD spectroscopy of octahedral uranium (V) complexes

C-term magnetic circular dichroism (MCD) spectroscopy is a powerful method for probing d–d and f–f transitions in paramagnetic metal complexes. However, this technique remains underdeveloped both experimentally and theoretically for studies of U(V) complexes of Oh symmetry, which have been of longstanding interest for probing electronic structure, bonding, and covalency in 5f systems. In this study, C-term NIR MCD of the Laporte forbidden f–f transitions of [UCl 6 ] - and [UF 6 ] - are reported, demonstrating the significant fine structure resolution possible with this technique including for the low energy Γ 7 → Γ 8 transitions in [UF 6 ] - . The experimental NIR MCD studies were further extended to [U(OC 6 F 5 ) 6 ] - , [U(CH 2 SiMe 3 ) 6 ] - , and [U(NC(tBu)(Ph)) 6 ] - to evaluate the effects of ligand-type on the f–f MCD fine structure features. Theoretical calculations were conducted to determine the Laporte forbidden f–f transitions and their MCD intensity experimentally observed in the NIR spectra of the U(V) hexahalide complexes, via the inclusion of vibronic coupling, to better understand the underlying spectral fine structure features for these complexes. These spectra and simulations provide an important platform for the application of MCD spectroscopy to this widely studied class of U(V) complexes and identify areas for continued theoretical development.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spatially resolved mass–metallicity relation at $z$ ~ 0.26 from the MUSE-Wide Survey

Galaxies in the local universe have a spatially resolved star-forming main sequence (rSFMS) and mass–metallicity relation (rMZR). We know that the global mass–metallicity relation (MZR) results from the integral of the rMZR, and it evolves with redshift. However, the evolution of the rMZR with redshift is still unclear because the spatial resolution and signal-to-noise ratio are low. Currently, too few observations beyond the local universe are available, and only simulations can reproduce the evolution of the rMZR with redshift. We selected ten emission-line galaxies with an average redshift of $z$ ~ 0.26 from the MUSE-Wide DR1. We obtained the spatially resolved star formation rate (SFR) and metallicity from integral field spectroscopy (IFS), as well as the stellar mass surface density from 3D-HST photometry. We derived the rSFMS and rMZR at $z$ ~ 0.26 and compared them with those of local galaxies. We find that the rSFMS of galaxies at $z$ ~ 0.26 has a slope of ~0.771. The rMZR exists at z ~ 0.26, showing a similar shape to that of the local universe, but a lower average metallicity that is about ~0.11 dex lower than the local metallicity. In addition, we also study the spatially resolved fundamental metallicity relation (rFMR) of these galaxies. However, there is no obvious evidence that an rFMR exists at $z$ ~ 0.26, and it is not an extension of rMZR at a high SFR. Similar to their global versions, the rSFMS and rMZR of galaxies also evolve with redshift. At fixed stellar mass, galaxies at higher redshift show a higher SFR and lower metallicity. In conclusion, these suggest that the evolution of the global galaxy properties with redshift may result from integrating the evolution of the spatially resolved galaxy properties.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of crystalline quality of traveling heater method (THM) grown Cd0.9Zn0.1Te0.98Se0.02 crystals

Because of its excellent opto-electronic properties, CdZnTe (CZT) has been the material of choice for x- and gamma-ray detectors operable at room temperature. CZT is the leading commercially available room-temperature radiation detector material today. Although much progress has been made over the past three decades, today's CZT crystals still face certain challenges, especially the presence of the performance-limiting materials defects and the associated relatively high production cost. In this regard, CdxZn1−xTeySe1−y (CZTS) is emerging as a next-generation compound semiconductor, which overcomes some of the limitations of CZT technology for the stated applications. Here, we conducted a study to evaluate the crystalline quality of the traveling heater method grown CZTS with an optimized alloy composition, i.e., Cd0.9Zn0.1Te0.98Se0.02. The as-grown samples were evaluated by low-temperature photoluminescence (PL) spectroscopy and high-resolution x-ray diffraction using the synchrotron light source at Brookhaven National Laboratory. The full width at half maximum of both the PL and x-ray rocking curves was observed to be broadened due to the lattice disorder of the quaternary compound, eventually degrading the crystalline quality. This was consistent with density functional theory calculations.

Roy, U. N. (ORCID:0000000282089680)↗

Synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Abstract Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument the future Timing Detectors of ATLAS and CMS for the High-Luminosity LHC. While initially conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low-energy X-rays with good energy resolution and excellent time resolution (tens of picoseconds). Using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 70 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2 ns intervals with an energy dispersion (ΔE/E) of 10 -4 . LGADs from Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 μm to 50 μm and different gain layer designs were read out using fast amplification boards and digitized with a high bandwidth and high sampling rate oscilloscope. PIN devices from HPK and AC-LGADs from BNL were characterized as well. A systematic and detailed characterization of the devices' energy linearity, resolution, and time resolution as a function of X-ray energy was performed for different biasing voltages at room temperature and are reported in this work. The charge collection and multiplication mechanism were simulated using Geant4 and TCAD Sentaurus, providing an important handle for interpreting the data.

Instruments & Instrumentation↗

Investigation of low gain avalanche detectors exposed to proton fluences beyond 10 15 n eq cm -2

Abstract Low gain avalanche detectors (LGADs) deliver excellent timing resolution, which can mitigate mis-assignment of vertices associated with pileup at the High Luminosity LHC and other future hadron colliders. The most highly irradiated LGADs will be subject to 2.5 × 10 15 n eq cm -2 of hadronic fluence during HL-LHC operation; their performance must tolerate this. Hamamatsu Photonics K.K. and Fondazione Bruno Kessler LGADs have been irradiated with 400 and 500 MeV protons respectively in several steps up to 1.5 × 10 15 n eq cm -2 . Measurements of the acceptor removal constants of the gain layers, evolution of the timing resolution and charge collection with damage, and inter-channel isolation characteristics, for a variety of design options, are presented here.

Instruments & Instrumentation↗

Bayesian inference of nuclear-matter density from proton scattering

Background: Proton elastic scattering at intermediate energy is widely employed as a tool for determining the matter radius of atomic nuclei. Here, the sensitivity of the approach relies on high-resolution measurements at small scattering angles and low-momentum transfer. Under these conditions, the Glauber multiple scattering theory accurately describes the proton-nucleus elastic cross section. Purpose: Investigate the sensitivity of the Glauber multiple scattering theory to uncertainties associated with input parameters such as the nuclear-matter density distribution and nucleon-nucleon data. Method: A joint Bayesian inference was performed using 12 angular distributions of elastic scattering at different energies on 58 Ni, 90 Zr, and 208 Pb targets. A Metropolis-Hastings algorithm was implemented to make an uncertainty quantification analysis for the input parameters used in the Glauber multiple scattering theory. Results: The experimental cross sections were fitted simultaneously using a joint Bayesian inference approach. Posterior probability density distributions of 42 input parameters were obtained from the analysis. A moderate correlation between the nuclear density parameters and the nucleon-nucleon cross sections was found. This correlation impacts the extraction of the nuclear-matter radius. Conclusions: The present analysis provided a consistent method for extracting the nuclear-matter density distribution of 58 Ni, 90 Zr, and 208 Pb from data across different incident energies. Due to the correlation of the nucleon-nucleon cross sections with the other input parameters, a constrained Bayesian inference using free nucleon-nucleon cross section data was performed. The nuclear-matter radii obtained from the analysis are in good agreement with multiple results reported in the literature.

190 ≤ A ≤ 219↗

Search for nonvirialized axions with 3.3 − 4.2 μ ⁢eV mass at selected resolving powers

The Axion Dark Matter eXperiment is sensitive to narrow axion flows, given axions compose a fraction of the dark matter with a non-negligible local density. Detecting these low-velocity dispersion flows requires a high spectral resolution and careful attention to the expected signal modulation due to Earth’s motion. Here, we report an exclusion on the local axion dark matter density in narrow flows of ρ a ≳ 0.03 GeV/cm 3 and ρ a ≳ 0.004 GeV/cm 3 for Dine-Fischler-Srednicki-Zhitnitski and Kim-Shifman-Vainshtein-Zakharov axion-photon couplings, respectively, over the mass range 3.3−4.2 μeV. Measurements were made at selected resolving powers to allow for a range of possible velocity dispersions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Laminography as a tool for imaging large-size samples with high resolution

Despite the increased brilliance of the new generation synchrotron sources, there is still a challenge with high-resolution scanning of very thick and absorbing samples, such as a whole mouse brain stained with heavy elements, and, extending further, brains of primates. Samples are typically cut into smaller parts, to ensure a sufficient X-ray transmission, and scanned separately. Compared with the standard tomography setup where the sample would be cut into many pillars, the laminographic geometry operates with slab-shaped sections significantly reducing the number of sample parts to be prepared, the cutting damage and data stitching problems. In this work, a laminography pipeline for imaging large samples (>1 cm) at micrometre resolution is presented. The implementation includes a low-cost instrument setup installed at the 2-BM micro-CT beamline of the Advanced Photon Source. Additionally, sample mounting, scanning techniques, data stitching procedures, a fast reconstruction algorithm with low computational complexity, and accelerated reconstruction on multi-GPU systems for processing large-scale datasets are presented. The applicability of the whole laminography pipeline was demonstrated by imaging four sequential slabs throughout an entire mouse brain sample stained with osmium, in total generating approximately 12 TB of raw data for reconstruction.

47 OTHER INSTRUMENTATION↗

Multiscale X-ray phase contrast imaging of human cartilage for investigating osteoarthritis formation

The evolution of cartilage degeneration is still not fully understood, partly due to its thinness, low radio-opacity and therefore lack of adequately resolving imaging techniques. X-ray phase-contrast imaging (X-PCI) offers increased sensitivity with respect to standard radiography and CT allowing an enhanced visibility of adjoining, low density structures with an almost histological image resolution. This study examined the feasibility of X-PCI for high-resolution (sub-) micrometer analysis of different stages in tissue degeneration of human cartilage samples and compare it to histology and transmission electron microscopy. Ten 10%-formalin preserved healthy and moderately degenerated osteochondral samples, post-mortem extracted from human knee joints, were examined using four different X-PCI tomographic set-ups using synchrotron radiation the European Synchrotron Radiation Facility (France) and the Swiss Light Source (Switzerland). Volumetric datasets were acquired with voxel sizes between 0.7 × 0.7 × 0.7 and 0.1 × 0.1 × 0.1 µm 3 . Data were reconstructed by a filtered back-projection algorithm, post-processed by ImageJ, the WEKA machine learning pixel classification tool and VGStudio max. For correlation, osteochondral samples were processed for histology and transmission electron microscopy. X-PCI provides a three-dimensional visualization of healthy and moderately degenerated cartilage samples down to a (sub-)cellular level with good correlation to histologic and transmission electron microscopy images. X-PCI is able to resolve the three layers and the architectural organization of cartilage including changes in chondrocyte cell morphology, chondrocyte subgroup distribution and (re-)organization as well as its subtle matrix structures. X-PCI captures comprehensive cartilage tissue transformation in its environment and might serve as a tissue-preserving, staining-free and volumetric virtual histology tool for examining and chronicling cartilage behavior in basic research/laboratory experiments of cartilage disease evolution.

3D analysis↗