Specimen-displacement correction for powder X-ray diffraction in Debye–Scherrer geometry with a flat area detector

The effect of small changes in the specimen-to-detector distance on the unit-cell parameters is examined for synchrotron powder diffraction in Debye–Scherrer (transmission) geometry with a flat area detector. An analytical correction equation is proposed to fix the shift in 2θ values due to specimen capillary displacement. This equation does not require the use of an internal reference material, is applied during the Rietveld refinement step, and is analogous to the specimen-displacement correction equations for Bragg–Brentano and curved-detector Debye–Scherrer geometry experiments, but has a different functional form. The 2θ correction equation is compared with another specimen-displacement correction based on the use of an internal reference material in which new integration and calibration parameters of area-detector images are determined. Example data sets showing the effect of a 3.3 mm specimen displacement on the unit-cell parameters for 25°C CeO 2 , including both types of displacement correction, are described. These experiments were performed at powder X-ray diffraction beamlines at the National Synchrotron Light Source II at Brookhaven National Laboratory and the Advanced Photon Source at Argonne National Laboratory.

36 MATERIALS SCIENCE↗

Adaptively coupled phase retrieval in multi-peak Bragg coherent diffraction imaging

Recent advances in Bragg coherent diffraction imaging (BCDI) experimental techniques permit routine measurement of multiple Bragg peaks from a single crystalline grain. The resulting images contain the full lattice distortion vector field which can be differentiated to provide lattice strain and rotation. With the advent of fourth-generation synchrotron light sources, such multi-peak datasets are produced at high rates, facilitating the need for rapid phase retrieval of the multiple peaks and subsequent image analysis. Here we describe and demonstrate a new implementation of a coupled phase retrieval technique for multi-peak BCDI which simultaneously treats each Bragg peak of the dataset and produces a three-dimensional image of the crystal's morphology and lattice distortion field. In addition, this method uses the redundant information contained in the various Bragg diffraction patterns to detect and suppress spurious signal appearing on the detector in a subset of the measurements. Compared with manual data editing, adaptive coupling produces a more consistent phase profile in reciprocal space and sharper surfaces in direct space, with no significant difference in computational cost. These improvements reduce the need for manual preprocessing and enable robust high-throughput analysis of multi-peak BCDI data, supporting near-real-time strain microscopy at modern synchrotron facilities.

36 MATERIALS SCIENCE↗

Phase-contrast 3D tomography of HeLa cells grown in PLLA polymer electrospun scaffolds using synchrotron X-rays

Advanced imaging is useful for understanding the three-dimensional (3D) growth of cells. X-ray tomography serves as a powerful noninvasive, nondestructive technique that can fulfill these purposes by providing information about cell growth within 3D platforms. There are a limited number of studies taking advantage of synchrotron X-rays, which provides a large field of view and suitable resolution to image cells within specific biomaterials. In this study, X-ray synchrotron radiation microtomography at Diamond Light Source and advanced image processing were used to investigate cellular infiltration of HeLa cells within poly L-lactide (PLLA) scaffolds. This study demonstrates that synchrotron X-rays using phase contrast is a useful method to understand the 3D growth of cells in PLLA electrospun scaffolds. Two different fiber diameter (2 and 4 µm) scaffolds with different pore sizes, grown over 2, 5 and 8 days in vitro , were examined for infiltration and cell connectivity. After performing visualization by segmentation of the cells from the fibers, the results clearly show deeper cell growth and higher cellular interconnectivity in the 4 µm fiber diameter scaffold. Finally, this indicates the potential for using such 3D technology to study cell–scaffold interactions for future medical use.

3D culture↗

X-ray free-electron laser wavefront sensing using the fractional Talbot effect

Wavefront sensing at X-ray free-electron lasers is important for quantitatively understanding the fundamental properties of the laser, for aligning X-ray instruments and for conducting scientific experimental analysis. A fractional Talbot wavefront sensor has been developed. This wavefront sensor enables measurements over a wide range of energies, as is common on X-ray instruments, with simplified mechanical requirements and is compatible with the high average power pulses expected in upcoming X-ray free-electron laser upgrades. Single-shot measurements were performed at 500 eV, 1000 eV and 1500 eV at the Linac Coherent Light Source. These measurements were applied to study both mirror alignment and the effects of undulator tapering schemes on source properties. The beamline focal plane position was tracked to an uncertainty of 0.12 mm, and the source location for various undulator tapering schemes to an uncertainty of 1m, demonstrating excellent sensitivity. These findings pave the way to use the fractional Talbot wavefront sensor as a routine, robust and sensitive tool at X-ray free-electron lasers as well as other high-brightness X-ray sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The ePix10k 2-megapixel hard X-ray detector at LCLS

The ePix10ka2M (ePix10k) is a new large area detector specifically developed for X-ray free-electron laser (XFEL) applications. The hybrid pixel detector was developed at SLAC to provide a hard X-ray area detector with a high dynamic range, running at the 120 Hz repetition rate of the Linac Coherent Light Source (LCLS). The ePix10k consists of 16 modules, each with 352 × 384 pixels of 100 µm × 100 µm distributed on four ASICs, resulting in a 2.16 megapixel detector, with a 16.5 cm × 16.5 cm active area and ∼80% coverage. The high dynamic range is achieved with three distinct gain settings (low, medium, high) as well as two auto-ranging modes (high-to-low and medium-to-low). Here the three fixed gain modes are evaluated. The resulting dynamic range (from single photon counting to 10000 photons pixel −1 pulse −1 at 8 keV) makes it suitable for a large number of different XFEL experiments. The ePix10k replaces the large CSPAD in operation since 2011. The dimensions of the two detectors are similar, making the upgrade from CSPAD to ePix10k straightforward for most setups, with the ePix10k improving on experimental performance. The SLAC-developed ePix cameras all utilize a similar platform, are tailored to target different experimental conditions and are designed to provide an upgrade path for future high-repetition-rate XFELs. Here the first measurements on this new ePix10k detector are presented and the performance under typical XFEL conditions evaluated during an LCLS X-ray diffuse scattering experiment measuring the 9.5 keV X-ray photons scattered from a thin liquid jet.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compensation of heat load deformations using adaptive optics for the ALS upgrade: a wave optics study

In this paper, a realistic wave optics simulation method has been developed to study how wavefront distortions originating from heat load deformations can be corrected using adaptive X-ray optics. Several planned soft X-ray and tender X-ray insertion-device beamlines in the Advanced Light Source upgrade rely on a common design principle. A flat, first mirror intercepts the white beam; vertical focusing is provided by a variable-line-space monochromator; and horizontal focusing comes from a single, pre-figured, adaptive mirror. A variety of scenarios to cope with thermal distortion in the first mirror are studied by finite-element analysis. The degradation of the intensity distribution at the focal plane is analyzed and the adaptive optics that correct it is modeled. The range of correctable wavefront errors across the operating range of the beamlines is reported in terms of mirror curvature and spatial frequencies. The software developed is a one-dimensional wavefront propagation package made available in the OASYS suite, an adaptable, customizable and efficient beamline modeling platform.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ronchi shearing interferometry for wavefronts with circular symmetry

Ronchi testing of a focused electromagnetic wave has in the last few years been used extensively at X-ray free-electron laser (FEL) facilities to qualitatively evaluate the wavefront of the beam. It is a quick and straightforward test, is easy to interpret on the fly, and can be used to align phase plates that correct the focus of aberrated beams. In general, a single Ronchigram is not sufficient to gain complete quantitative knowledge of the wavefront. However the compound refractive lenses that are commonly used at X-ray FELs exhibit a strong circular symmetry in their aberration, and this can be exploited. Furthermore, a simple algorithm that uses a single recorded Ronchigram to recover the full wavefront of a nano-focused beam, assuming circular symmetry, is presented, and applied to experimental measurements at the Matter in Extreme Conditions instrument at the Linac Coherent Light Source.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of the damping wiggler effect and application on the PAL fourth-generation storage ring

An investigation of the damping wiggler effect to reduce the emittance in the Pohang Accelerator Laboratory (PAL), a fourth-generation storage ring (4GSR) that uses a multi-bend achromat, is presented. Furthermore, a 4GSR lattice which has reduced emittance and increased dynamic aperture to amplify the synergy with two existing light sources (PLS-II and PAL-XFEL) at PAL is described.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The effect of longer-range waviness on X-ray reflectivity measurements

A model for calculating the X-ray reflectivity (XRR) of surfaces to extract both roughness and waviness features is presented. Expressions of reflectivity intensity are derived as a function of root-mean-square (RMS) roughness σ, RMS waviness σ L , and the cut-off frequency between the features ω 0 . Experiments were conducted at the Advanced Light Source at Lawrence Berkeley National Laboratory, beamline 8.3.2, on BK7 glass manufactured with a multi-step polishing process to validate the model, and were compared with atomic force microscopy (AFM), Fizeau interferometry and surface profilometry measurements. Here, the parameter results and their deviations for XRR measurements were σ = 2.9 ± 0.2 nm and σ L = 14.6 ± 0.5 nm with a wavelength cut-off of 1/(18 ± 2) µm –1 , while the results from the AFM, Fizeau and profilometry measurements were σ AFM = 3.4 ± 0.4 nm, σ L,Fizeau = 21.6 nm, σ prof = 4.0 ± 0.1 nm, and σ L,prof = 21.4 ± 0.1 nm with cut-offs for the profilometry and Fizeau measurements limited to frequencies of (1/16) µm –1 to (1/4) mm –1 .

42 ENGINEERING↗

Fast digital lossy compression for X-ray ptychographic data

Increases in X-ray brightness from synchrotron light sources lead to a requirement for higher frame rates from hybrid pixel array detectors (HPADs), while also favoring charge integration over photon counting. However, transfer of the full uncompressed data will begin to constrain detector design, as well as limit the achievable continuous frame rate. Here a data compression scheme that is easy to implement in a HPAD's application-specific integrated circuit (ASIC) is described, and how different degrees of compression affect image quality in ptychography, a commonly employed coherent imaging method, is examined. Using adaptive encoding quantization, it is shown in simulations that one can digitize signals up to 16383 photons per pixel (corresponding to 14 bits of information) using only 8 or 9 bits for data transfer, with negligible effect on the reconstructed image.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simulations of applications using diaboloid mirrors

The diaboloid is a reflecting surface that converts a spherical wave to a cylindrical wave. This complex surface may find application in new Advanced Light Source bending-magnet beamlines or in other beamlines that now use toroidal optics for astigmatic focusing. Here, the numerical implementation of diaboloid mirrors is described, and the benefit of this mirror in beamlines exploiting diffraction-limited storage rings is studied by ray tracing. The use of diaboloids becomes especially interesting for the new low-emittance storage rings because the reduction of aberration becomes essential for such small sources. Here, the validity of the toroidal and other mirror surfaces approximating the diaboloid, and the effect of the mirror magnification, are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantitative phase measurements of human cell nuclei using X-ray ptychography

The human cell nucleus serves as an important organelle holding the genetic blueprint for life. In this work, X-ray ptychography was applied to assess the masses of human cell nuclei using its unique phase shift information. Measurements were carried out at the I13-1 beamline at the Diamond Light Source that has extremely large transverse coherence properties. Furthermore, the ptychographic diffractive imaging approach allowed imaging of large structures that gave quantitative measurements of the phase shift in 2D projections. In this paper a modified ptychography algorithm that improves the quality of the reconstruction for weak scattering samples is presented. The application of this approach to calculate the mass of several human nuclei is also demonstrated.

59 BASIC BIOLOGICAL SCIENCES↗

New high-throughput endstation to accelerate the experimental optimization pipeline for synchrotron X-ray footprinting

Synchrotron X-ray footprinting (XF) is a growing structural biology technique that leverages radiation-induced chemical modifications via X-ray radiolysis of water to produce hydroxyl radicals that probe changes in macromolecular structure and dynamics in solution states of interest. The X-ray Footprinting of Biological Materials (XFP) beamline at the National Synchrotron Light Source II provides the structural biology community with access to instrumentation and expert support in the XF method, and is also a platform for development of new technological capabilities in this field. Hee, the design and implementation of a new high-throughput endstation device based around use of a 96-well PCR plate form factor and supporting diagnostic instrumentation for synchrotron XF is described. This development enables a pipeline for rapid comprehensive screening of the influence of sample chemistry on hydroxyl radical dose using a convenient fluorescent assay, illustrated here with a study of 26 organic compounds. The new high-throughput endstation device and sample evaluation pipeline now available at the XFP beamline provide the worldwide structural biology community with a robust resource for carrying out well optimized synchrotron XF studies of challenging biological systems with complex sample compositions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Use of diamond sensors for a high-flux, high-rate X-ray pass-through diagnostic

X-ray free-electron lasers (XFELs) deliver pulses of coherent X-rays on the femtosecond time scale, with potentially high repetition rates. While XFELs provide high peak intensities, both the intensity and the centroid of the beam fluctuate strongly on a pulse-to-pulse basis, motivating high-rate beam diagnostics that operate over a large dynamic range. The fast drift velocity, low X-ray absorption and high radiation tolerance properties of chemical vapour deposition diamonds make these crystals a promising candidate material for developing a fast (multi-GHz) pass-through diagnostic for the next generation of XFELs. A new approach to the design of a diamond sensor signal path is presented, along with associated characterization studies performed in the XPP endstation of the LINAC Coherent Light Source (LCLS) at SLAC. Qualitative charge collection profiles (collected charge versus time) are presented and compared with those from a commercially available detector. Quantitative results on the charge collection efficiency and signal collection times are presented over a range of approximately four orders of magnitude in the generated electron–hole plasma density.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Real-time streaming tomographic reconstruction with on-demand data capturing and 3D zooming to regions of interest

Complex dynamic tomographic experiments at brilliant X-ray light sources require real-time feedback on the sample changes with respect to environmental conditions, selecting representative regions of interest for high-resolution scanning, and on-demand data saving mechanisms for storing only relevant projections acquired by fast area detectors and reducing data volumes. Here the implementation details of a 3D real-time imaging monitoring instrument, with zooming to a volume of interest with easy-to-use visualization via ImageJ , a tool familiar to most beamline users, is presented. The instrument relies on optimized data flow between the detector and processing machines and is implemented on commodity computers. The instrument has been developed at beamline 2-BM of the Advanced Photon Source, where the automatic lens changing mechanism for zooming is implemented with an Optique Peter microscope. Performance tests demonstrate the ability to process more than 3 GB of projection data per second and generate real-time 3D zooming with different magnification. These new capabilities are essential for new APS Upgrade instruments such as the projection microscope under development at beamline 32-ID. The efficacy of the proposed instrument was demonstrated during an in situ tomographic experiment on ice and gas hydrate formation in porous samples.

3D zooming↗

Towards performing high-resolution inelastic X-ray scattering measurements at hard X-ray free-electron lasers coupled with energetic laser drivers

High-resolution inelastic X-ray scattering is an established technique in the synchrotron community, used to investigate collective low-frequency responses of materials. When fielded at hard X-ray free-electron lasers (XFELs) and combined with high-intensity laser drivers, it becomes a promising technique for investigating matter at high temperatures and high pressures. This technique gives access to important thermodynamic properties of matter at extreme conditions, such as temperature, material sound speed, and viscosity. The successful realization of this method requires the acquisition of many identical laser-pump/X-ray-probe shots, allowing the collection of a sufficient number of photons necessary to perform quantitative analyses. Here, a 2.5-fold improvement in the energy resolution of the instrument relative to previous works at the Matter in Extreme Conditions (MEC) endstation, Linac Coherent Light Source (LCLS), and the High Energy Density (HED) instrument, European XFEL, is presented. Some aspects of the experimental design that are essential for improving the number of photons detected in each X-ray shot, making such measurements feasible, are discussed. A careful choice of the energy resolution, the X-ray beam mode provided by the XFEL, and the position of the analysers used in such experiments can provide a more than ten-fold improvement in the photometrics. The discussion is supported by experimental data on 10 µm-thick iron and 50 nm-thick gold samples collected at the MEC endstation at the LCLS, and by complementary ray-tracing simulations coupled with thermal diffuse scattering calculations.

36 MATERIALS SCIENCE↗

The Inner Shell Spectroscopy beamline at NSLS-II: a facility for in situ and operando X-ray absorption spectroscopy for materials research

The Inner Shell Spectroscopy (ISS) beamline on the 8-ID station at the National Synchrotron Light Source II (NSLS-II), Upton, NY, USA, is a high-throughput X-ray absorption spectroscopy beamline designed for in situ, operando, and time-resolved material characterization using high monochromatic flux and scanning speed. This contribution discusses the technical specifications of the beamline in terms of optics, heat load management, monochromator motion control, and data acquisition and processing. Results of the beamline tests demonstrating the quality of the data obtainable on the instrument, possible energy scanning speeds, as well as long-term beamline stability are shown. The ability to directly control the monochromator trajectory to define the acquisition time for each spectral region is highlighted. Examples of studies performed on the beamline are presented. The paper is concluded with a brief outlook for future developments.

36 MATERIALS SCIENCE↗

Flexible positioning of a large area detector using an industrial robot

The DIAD beamline for Dual Imaging and Diffraction at Diamond Light Source has opted to use an industrial robot to position its Dectris Pilatus 2M CdTe diffraction detector. This setup was chosen to enable flexible positioning of the detector in a quarter-sphere around the sample position whilst reliably holding the large weight of 139 kg of detector, detector mount and cabling in a stable position. Metrology measurements showed that the detector can be positioned with a linear repeatability of <19.7 µm and a rotational repeatability of <16.3 µrad. The detector position stays stable for a 12 h period with <10.1 µm of movement for linear displacement and <3.8 µrad for rotational displacement. X-ray diffraction from calibration samples confirmed that the robot is sufficiently stable to resolve lattice d-spacings within the instrumental broadening given by detector position and beam divergence.