Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Light sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Synchronization trigger control system for flow visualization

The use of cinematography or holographic interferometry for dynamic flow visualization in an internal combustion engine requires a control device that globally synchronizes camera and light source timing at a predefined shaft encoder angle. The device is capable of 0.35 deg resolution for rotational speeds of up to 73 240 rpm. This was achieved by implementing the shaft encoder signal addressed look-up table (LUT) and appropriate latches. The developed digital signal processing technique achieves 25 nsec of high speed triggering angle detection by using direct parallel bit comparison of the shaft encoder digital code with a simulated angle reference code, instead of using angle value comparison which involves more complicated computation steps. In order to establish synchronization to an AC reference signal whose magnitude is variant with the rotating speed, a dynamic peak followup synchronization technique has been devised. This method scrutinizes the reference signal and provides the right timing within 40 nsec. Two application examples are described.

Chun, K. S.↗

NASA star simulator

A star simulator is described which is capable of simulating a field of three or more stars in response to signals from a computer interface. Star magnitude and spectral output can be manipulated and absolute position measurements can be obtained with the system. The simulator is a single axis system which consists of two assemblies: a light source and filter wheel assembly, and a translation stage assembly. The assemblies are self contained on 60.96 x 60.96 cm breadboards and are connected via three fiber optic cables. A summary of operational modes is provided.

Source record↗

Resonant enhanced multiphoton ionization studies of atomic oxygen

In resonant enhanced multiphoton ionization (REMPI), an atom absorbs several photons making a transition to a resonant intermediate state and subsequently ionizing out of it. With currently available tunable narrow-band lasers, the extreme sensitivity of REMPI to the specific arrangement of levels can be used to selectively probe minute amounts of a single species (atom) in a host of background material. Determination of the number density of atoms from the observed REMPI signal requires a knowledge of the multiphoton ionization cross sections. The REMPI of atomic oxygen was investigated through various excitation schemes that are feasible with available light sources. Using quantum defect theory (QDT) to estimate the various atomic parameters, the REMPI dynamics in atomic oxygen were studied incorporating the effects of saturation and a.c. Stark shifts. Results are presented for REMPI probabilities for excitation through various 2p(3) (4S sup o) np(3)P and 2p(3) (4S sup o) nf(3)F levels.

Dixit, S. N.↗

Fluorescence from VUV excitation of formaldehyde

The 105-180-nm photoabsorption and fluorescence cross sections of H2CO are determined experimentally using a synchrotron-radiation light source and the apparatus described by Lee (1980). The results are presented in tables and graphs and discussed. VUV emission with threshold wavelength 140.3 nm is detected and attributed to the A 1Pi - X 1Sigma(+) system of CO, and UV emission from the HCO (B-X) system is found below a 147.5-nm threshold, the H-HCO dissociation energy having an upper limit of 3.61 + or - 0.03 eV. At 116 nm, the maximum quantum yields of the VUV and UV fluorescences are about 1.6 and 0.23 percent, respectively.

Suto, Masako↗

Effects of excitation intensity on the photocurrent response of thin film silicon solar modules

Photocurrent responses of amorphous thin film silicon solar modules at room temperature were studied at different excitation intensities using various monochromatic light sources. Photocurrent imaging techniques have been effectively used to locate rapidly, and non-destructively, failure and defect sites in the multilayer thin film device. Differences observed in the photocurrent response characteristics for two different cells in the same amorphous thin film silicon solar module suggest the possibility of the formation of dissimilarly active devices, even though the module is processed in the same fabrication process. Possible mechanisms are discussed.

Kim, Q.↗

High-resolution optical and ultraviolet absorption-line studies of interstellar gas

Recent progress in the characterization of the interstellar medium (ISM) by means of optical and UV spectral data is summarized. The gas is studied by focusing on background stars whose spectra can be accurately modeled to provide the light source for the absorption-line scans. The capabilities of earth- and space-based instruments which have been and are used for the surveys are delineated. The distributions of diffuse gas densities and characteristics of the cold, warm and hot gas in the Galaxy are described in terms of the elemental abundances, kinetics and distributions of the gas. Particular note is taken of gas in the solar neighborhood and around SNR, and of absorption-line data of cosmological significance.

Cowie, Lennox L.↗

Quantitative photoabsorption and fluorescence spectroscopy of H2S and D2S at 49-240 nm

Photoabsorption and fluorescence cross sections of H2S and D2S were measured in the 49-240 nm region using synchrotron radiation as a light source. Fluorescence from photoexcitation of H2S appears at 49-97 nm, but not in the long wavelength region. Fluorescence spectra were dispersed, and used to identify the emitters to be H2S(+) (A), SH(+)(A), and H(n greater than 2). The fluorescence quantum yield is about 6 percent. Photoexcitation of D2S at 49-96 nm produces fluorescence with a quantum yield of about 5 percent. The emitters are identified from the fluorescence spectra to be D2S(+)(A), SD(+)(A), and D(n greater than 2). The Franck-Condon factors for the SH(+) and SD(+) (A-X) transitions were determined. The SD(A-X) fluorescence was observed from photoexcitation of D2S at 100-151 nm, for which the fluorescence cross section and quantum yield were measured.

Lee, L. C.↗

Quantitative photoabsorption and fluorescence study of H2O and D2O at 50-190 nm

The photoabsorption cross sections and the fluorescence quantum yields of H2O and D2O were measured in the 50-190 nm region using synchrotron radiation as a light source. The oscillator strengths for the Rydberg states of H2O and D2O were determined from the absorption cross sections measured. The processes for the production of fluorescence from the excited species H(asterisk) (n greater than 2), D(asterisk) (n greater than 2), OH(asterisk) (A) and OD(asterisk) (A) are discussed. The upper limit for the dissociation energy of D(D-OD) was determined, from the threshold of the OD(A-X) fluorescence, to be 5.14 + or - 0.01 eV. The upper limit for the cross section of visible fluorescence from the excited H2O(+) ions was determined to be 2 x 10 to the -19th sq cm. A comparison between the photoexcitation spectra of H2O and D2O is made.

Lee, L. C.↗

Stereoscopic Optical Signal Processor

Optical signal processor produces two-dimensional cross correlation of images from steroscopic video camera in real time. Cross correlation used to identify object, determines distance, or measures movement. Left and right cameras modulate beams from light source for correlation in video detector. Switch in position 1 produces information about range of object viewed by cameras. Position 2 gives information about movement. Position 3 helps to identify object.

Graig, Glenn D.↗

Computer-Aided Goniophotometer

Repetitive measurements made more rapidly, with greater accuracy. Computer-compatible scanning goniophotometer enables semiautomatic measurement of angular uniformity of integrating hemisphere or other large-aperture light source. Scanning mechanism eliminates need to locate photometer manually at each viewing angle. Keeps photometer pointed at center of aperture while moving it to different viewing positions. Scanning motion of x-y plotter forms raster in vertical plane. Viewing angles visualized by simply drawing line from desired point on raster to center of aperture.

Holt, Richard G.↗

Development of response models for the Earth Radiation Budget Experiment (ERBE) sensors. Part 2: Analysis of the ERBE integrating sphere ground calibration

An explicit solution of the spectral radiance leaving an arbitrary point on the wall of a spherical cavity with diffuse reflectivity is obtained. The solution is applicable to spheres with an arbitrary number of openings of any size and shape, an arbitrary number of light sources with possible non-diffuse characteristics, a non-uniform sphere wall temperature distribution, non-uniform and non-diffuse sphere wall emissivity and non-uniform but diffuse sphere wall spectral reflectivity. A general measurement equation describing the output of a sensor with a given field of view, angular and spectral response measuring the sphere output is obtained. The results are applied to the Earth Radiation Budget Experiment (ERBE) integrating sphere. The sphere wall radiance uniformity, loading effects and non-uniform wall temperature effects are investigated. It is shown that using appropriate interpretation and processing, a high-accuracy short-wave calibration of the ERBE sensors can be achieved.

Halyo, Nesim↗

Photoabsorption and phototdissociation of molecules important in the interstellar medium

The photoabsorption and photodissociation cross sections of interstellar molecules and radicals were measured in the 90 to 200 nm region using synchrotron radiation, F sub 2 laser, excimer lasers, and discharge lamps as light sources. These data are currently needed for determining the formation and destruction rates of molecules and radicals by the interstellar radiation field.

Lee, Long C.↗

Fiber optic sensing systems using high frequency resonant sensing heads with intensity sensors

Optical fibers have an inherent capability of transmitting high bandwidth analog and digital signals. To apply this property of fiber optics to remote sensing, special sensing heads as well as signal processing electronics have to be developed. In systems employing intensity modulating sensors, there is also a need for a referencing technique to compensate for changes in the transmission of the connecting fibers and light source intensity. Fiber optic sensing systems incorporated in sensing heads of a special configuration are discussed. Different modes of operation as well as resonant conditions are explained. Theoretical and experimental analyses are also given.

Adamovsky, Grigory↗

Comparison of the bidirectional reflectance distribution function of various surfaces

Described is the development and use of a system to measure the Bidirectional Reflectance Distribution Function (BRDF) of various surfaces. The BRDF measurements are used in the analysis and design of optical measurement systems, such as laser anemometers. An argon ion laser (514 nm) is the light source. Preliminary results are presented for eight samples: two glossy black paints, two flat black paints, black glass, sand blasted aluminum, unworked aluminum, and a white paint. A BaSO4 white reflectance standard was used as the reference sample throughout the tests. The reflectance characteristics of these surfaces are compared.

Fernandez, Rene↗

Spectrogoniometer for measuring planetary surface materials at small phase angles

This paper describes an instrument, termed spectrogoniometer, which was designed to measure the bidirectional reflectance properties of planetary surface analogs at very small phase angles. By using a pellicle beam splitter, a highly collimated laser light source, and a carefully aligned apparatus it was possible to measure the reflectance properties of geologic samples under any viewing geometry: the angles of incidence and emission ranging from 0 to 90 deg, and the azimuthal angle ranging from 0 to 360 deg. The results on the effect of porosity are demonstrated by comparing measurements on a compact sample (with a void space of 25 percent) and a fluffy sample (with a void space of 90 percent). The fluffy sample exhibited a 30-percent increase in intensity between 10 and 0 deg, whereas the compact sample exhibited only a 20-percent increase.

Buratti, Bonnie J.↗

CF2 and CFCl fluorescence from VUV excitation of C2F3Cl

The photoexcitation process of the C2F3Cl molecule was investigated in the 106-230-nm region using synchrotron radiation as a light source. Photoabsorption and fluorescence cross sections were measured and used to determine the fluorescence quantum yield. Fluorescence yield starts to appear at 170 nm and increases to about 2 percent at 155 nm. The fluorescence spectra were dispersed to identify the emitting species. The (A-X) systems of CFCl (at excitation wavelengths 155 and 123.9 nm) and CF2 (at 123.9 nm) are observed. The dissociation processes that produced these excited species are discussed.

Nee, J. B.↗

Fluorescence yields from photodissociative excitation of chloromethanes by vacuum ultraviolet radiation

The photoabsorption and fluorescence cross sections of chloromethanes were measured in the 105-220 nm region using synchrotron radiation as a light source. The fluorescence threshold for CCl4 is at 152 nm with a maximum yield of 3 percent at 113 nm. The fluorescence results from the CCl2(A-X) system. For CHCl3, the fluorescence threshold is at 155 nm with a maximum yield of 0.6 percent at 110 nm. For CH2Cl2, the threshold is at 137 nm with a maximum yield of 0.35 percent at 107 nm. The fluorescence yield of CH3Cl is very small with an upper limit of 0.02 percent. The photodissociation processes are discussed in accord with the fluorescence data observed. Vibrational structures in CHCl3 and CH3Cl2 are observed and classified into progressions.

Lee, L. C.↗

Strong north/south asymmetry in the Jovian stratosphere

Trailed spectra of standard B stars have been used as the 'flat' field light source for spatial calibration of IUE large-aperture observations of the north and south polar regions of Jupiter. Longward of 2000 A, the south polar spectrum is lower than the north polar one by a factor of 2.5; shortward of 2000 A, strong C2H2 absorption appears in both north polar and midlatitude spectra, while neither continuum nor band absorption features of C2H2 appear in the south polar spectrum. The very low reflectivity of the south polar region calls for the presence of a stratospheric absorber at pressures lower than 10 mbar.

Wagener, Richard↗