Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Laser dynamics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Lunar Laser Ranging in the Artemis Era

The retroreflector arrays placed on the lunar surface by the Apollo astronauts and the Soviet Luna missions continue to contribute to our understanding of gravitational physics, Earth and Moon geophysics, geodesy, and dynamics. The key science questions addressed by Lunar Laser Ranging remain very relevant today: What is the interior structure of the Moon? Is the Equivalence Principle exact? Does the strength of gravity vary with space and time? What is the nature of spacetime? Do extra dimensions or other new physics alter the inverse square law of gravity? The lunar retroreflectors are also an essential component of the realizations of the lunar reference frames. The half-century old lunar retroreflectors continue to provide excellent ranging targets but are showing signs of degradation and the measurement error associated with their physical size and varying tilt is becoming a limitation in the quest for more precise range measurements. In addition, the clustering of the arrays in the mid-latitudes of the Moon limits their geometrical strength and coverage. The south polar region planned for Artemis presents an ideal opportunity for improving the geometric distribution. Retroreflectors utilizing a large optical cross-section single cube corner do not have tilt error associated with the existing arrays making them good options for lunar deployment. Several new retroreflectors of this type are being prepared for upcoming Commercial Lunar Payload Services missions as well as Artemis. This presentation will discuss NASA’s plans for expanding the lunar laser ranging capabilities with a focus on the Artemis Lunar Laser Retroreflector.

Stephen Merkowitz↗

Polar motion results from GEOS 3 laser ranging

The observability of polar motion from laser range data has been investigated, and the contributions from the dynamical and kinematical effects have been evaluated. Using 2-day arcs with GEOS 3 laser data, simultaneous solutions for pole position components and orbit elements have been obtained for a 2-week interval spanning August 27 to September 10, 1975, using three NASA Goddard Space Flight Center stations located at Washington, D.C., Bermuda, and Grand Turk. The results for the y-component of pole position from this limited data set differenced with the BIH linearly interpolated values yield a mean of 39 cm and a standard deviation of 1.07 m. Consideration of the variance associated with each estimate yields a mean of 20 cm and a standard deviation of 81 cm. The results for the x-component of pole position indicate that the mean value is in fair agreement with the BIH; however, the x-coordinate determination is weaker than the y-coordinate determination due to the distribution of laser sites (all three are between 77 deg W and 65 deg W) which results in greater sensitivity to the data distribution. In addition, the sensitivity of these results to various model parameters is discussed.

Schutz, B. E.↗

Laser-driven flyer plate impact: Computational studies guided by experiments

We present a computational approach using a multimaterial, arbitrary Lagrangian–Eulerian code termed ALE3D to model the nanosecond/micrometer dynamics of the launch of 0.5–4.5 km/s laser-driven metal flyer plates and the impact with stationary targets of Pyrex and fused silica glasses, and Lexan and Plexiglas polymers, producing pressures in the target in the range of 5–20 GPa. The simulations are compared to experimental results where the flyer velocity profile and the velocity profile imparted to the target material were measured with high-speed velocimetry. The experimental flyer launch by a high-intensity pulsed laser is modeled by depositing heat into a thin vaporizable layer under the flyer plate. This model produces a flyer plate that has not been exposed to the laser pulse, allowing us to compare the properties of the real flyer to a simulated ideal flyer. The simulations of target impact are generally in good agreement with the experiment except at the highest impact velocities where the shock release process in the experiment is slower than that in the simulation. The cause of this disagreement is attributed to an inadequate description of the shock viscosity during the nanosecond unloading process.

Stekovic, Svjetlana (ORCID:0000000163878070)↗

Remote displacement measurements using a laser diode

A technique for measuring displacements remotely to minimum distances of 8 mm with a resolution of 2 microns is described. A dynamic interferometer method is employed using a frequency-ramped laser diode. A direct measurement of the period of the resulting beat signal is used to determine the displacement.

Beheim, G.↗

Laser Light Scattering Diagnostic for Measurement of Flow Velocity in Vicinity of Propagating Shock Waves

A laser light scattering diagnostic for measurement of dynamic flow velocity at a point is described. The instrument is being developed for use in the study of propagating shock waves and detonation waves in pulse detonation engines under development at the NASA Glenn Research Center (GRC). The approach uses a Fabry-Perot interferometer to measure the Doppler shift of laser light scattered from small (submicron) particles in the flow. The high-speed detection system required to resolve the transient response as a shock wave crosses the probe volume uses fast response photodetectors, and a PC based data acquisition system. Preliminary results of measurements made in the GRC Mach 4, 10 by 25 cm supersonic wind tunnel are presented. Spontaneous condensation of water vapor in the flow is used as seed. The tunnel is supplied with continuous air flow at up to 45 psia and the flow is exhausted into the GRC laboratory-wide altitude exhaust system at pressures down to 0.3 psia.

Seasholtz, Richard G.↗

Kinetic Landau-fluid closures of non-Maxwellian distributions

New kinetic Landau-fluid closures, based on the cutoff Maxwellian distribution, are derived. A special static case is considered (the frequency ω=0). In the strongly collisional regime, our model reduces to Braginskii's heat flux model, and the transport is local. In the weak collisional regime, our model indicates that the heat flux is non-local and recovers the Hammett–Perkins model while the value of the cutoff velocity approaches to infinity. We compare the thermal transport coefficient χ of Maxwellian, cutoff Maxwellian and super-Gaussian distribution. The results show that the reduction of the high-speed tail particles leads to the corresponding reduction of the thermal transport coefficient χ across the entire range of collisionality, more reduction of the free streaming transport toward the weak collisional regime. In the collisionless limit, χ approaches to zero for the cutoff Maxwellian and the super-Gaussian distribution but remains finite for Maxwellian distribution. χ is complex if the cutoff Maxwellian distribution is asymmetric. The Im(χ) approaches to different convergent values in both collisionless and strongly collisional limit, respectively. It yields an additional streaming heat flux in comparison with the symmetric cutoff Maxwellian distribution. Furthermore, due to the asymmetric distribution, there is a background heat flux q0 though there is no perturbation. Furthermore, the derived Landau-fluid closures are general for fluid moment models, and applicable for the cutoff Maxwellian distribution in an open magnetic field line region, such as the scape-off-layer of Tokamak plasmas, in the thermal quench plasmas during a tokamak disruption, and the super-Gaussian electron distribution function due to inverse bremsstrahlung heating in laser-plasma studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The interplay between vapour, liquid, and solid phases in laser powder bed fusion

The capability of producing complex, high performance metal parts on demand has established laser powder bed fusion (LPBF) as a promising additive manufacturing technology, yet deeper understanding of the laser-material interaction is crucial to exploit the potential of the process. By simultaneous in-situ synchrotron x-ray and schlieren imaging, we probe directly the interconnected fluid dynamics of the vapour jet formed by the laser and the depression it produces in the melt pool. The combined imaging shows the formation of a stable plume over stable surface depressions, which becomes chaotic following transition to a full keyhole. We quantify process instability across several parameter sets by analysing keyhole and plume morphologies, and identify a previously unreported threshold of the energy input required for stable line scans. The effect of the powder layer and its impact on process stability is explored. These high-speed visualisations of the fluid mechanics governing LPBF enable us to identify unfavourable process dynamics associated with unwanted porosity, aiding the design of process windows at higher power and speed, and providing the potential for in-process monitoring of process stability.

36 MATERIALS SCIENCE↗

Measuring Transverse Displacements Using Unmanned Aerial Systems Laser Doppler Vibrometer (UAS-LDV): Development and Field Validation

Measurement of bridge displacements is important for ensuring the safe operation of railway bridges. Traditionally, contact sensors such as Linear Variable Displacement Transducers (LVDT) and accelerometers have been used to measure the displacement of the railway bridges. However, these sensors need significant effort in installation and maintenance. Therefore, railroad management agencies are interested in new means to measure bridge displacements. This research focuses on mounting Laser Doppler Vibrometer (LDV) on an Unmanned Aerial System (UAS) to enable contact-free transverse dynamic displacement of railroad bridges. Researchers conducted three field tests by flying the Unmanned Aerial Systems Laser Doppler Vibrometer (UAS-LDV) 1.5 m away from the ground and measured the displacement of a moving target at various distances. The accuracy of the UAS-LDV measurements was compared to the Linear Variable Differential Transducer (LVDT) measurements. The results of the three field tests showed that the proposed system could measure non-contact, reference-free dynamic displacement with an average peak and root mean square (RMS) error for the three experiments of 10% and 8% compared to LVDT, respectively. Such errors are acceptable for field measurements in railroads, as the interest prior to bridge monitoring implementation of a new approach is to demonstrate similar success for different flights, as reported in the three results. This study also identified barriers for industrial adoption of this technology and proposed operational development practices for both technical and cost-effective implementation.

42 ENGINEERING↗

Dynamic motion trajectory control with nanoradian accuracy for multi-element X-ray optical systems via laser interferometry

The past decades have witnessed the development of new X-ray beam sources with brightness growing at a rate surpassing Moore’s law. Current and upcoming diffraction limited and fully coherent X-ray beam sources, including multi-bend achromat based synchrotron sources and high repetition rate X-ray free electron lasers, puts increasingly stringent requirements on stability and accuracy of X-ray optics systems. Parasitic motion errors at sub-micro radian scale in beam transport and beam conditioning optics can lead to significant loss of coherence and brightness delivered from source to experiment. To address this challenge, we incorporated optical metrology based on interferometric length and angle sensing and real-time correction as part of the X-ray optics motion control system. A prototype X-ray optics system was constructed following the optical layout of a tunable X-ray cavity. On-line interferometric metrology enabled dynamical feedback to a motion control system to track and compensate for motion errors. The system achieved sub-microradian scale performance, as multiple optical elements are synchronously and continuously adjusted. This first proof of principle measurement demonstrated both the potential and necessity of incorporating optical metrology as part of the motion control architecture for large scale X-ray optical systems such as monochromators, delay lines, and in particular, X-ray cavity systems to enable the next generation cavity-based X-ray free electron lasers.

47 OTHER INSTRUMENTATION↗

Test Methodology Development for Experimental Structural Assessment of ASC Planar Spring Material for Long-Term Durability

A vibration-based testing methodology has been developed that will assess fatigue behavior of the metallic material of construction for the Advanced Stirling Convertor displacer (planar) spring component. To minimize the testing duration, the test setup is designed for base-excitation of a multiplespecimen arrangement, driven in a high-frequency resonant mode; this allows completion of fatigue testing in an accelerated period. A high performance electro-dynamic exciter (shaker) is used to generate harmonic oscillation of cantilever beam specimens, which are clasped on the shaker armature with specially-designed clamp fixtures. The shaker operates in closed-loop control with dynamic specimen response feedback provided by a scanning laser vibrometer. A test coordinator function synchronizes the shaker controller and the laser vibrometer to complete the closed-loop scheme. The test coordinator also monitors structural health of the test specimens throughout the test period, recognizing any change in specimen dynamic behavior. As this may be due to fatigue crack initiation, the test coordinator terminates test progression and then acquires test data in an orderly manner. Design of the specimen and fixture geometry was completed by finite element analysis such that peak stress does not occur at the clamping fixture attachment points. Experimental stress evaluation was conducted to verify the specimen stress predictions. A successful application of the experimental methodology was demonstrated by validation tests with carbon steel specimens subjected to fully-reversed bending stress; high-cycle fatigue failures were induced in such specimens using higher-than-prototypical stresses

fatigue testing machines↗

Particle flow within a transonic compressor rotor passage with application to laser-Doppler velocimetry

A theoretical analysis was conducted of the dynamic behavior of micron size particles moving in the three-dimensional flow field of a rotating transonic axial-flow air compressor rotor. The particle velocity lag and angular deviation relative to the gas were determined as functions of particle diameter, mass density and radial position. Particle size and density were varied over ranges selected to correspond to typical laser-Doppler velocimeter (LDV) flow field mapping applications. It was found that the particles move essentially on gas stream surfaces and that particle tracking is relatively insensitive to the rotor radial coordinate. Velocity lag and angular deviation increased whenever particle size or mass density increased, and particle tracking was more sensitive to a change in particle diameter than to a corresponding change in mass density. Results indicated that velocity and angular deviations generally less than 1 percent and 1 degree could be achieved with 1 gm/cc tracer particles with diameters of 1 micron or less.

Maxwell, B. R.↗

Tissue Photolithography

Tissue lithography will enable physicians and researchers to obtain macromolecules with high purity (greater than 90 percent) from desired cells in conventionally processed, clinical tissues by simply annotating the desired cells on a computer screen. After identifying the desired cells, a suitable lithography mask will be generated to protect the contents of the desired cells while allowing destruction of all undesired cells by irradiation with ultraviolet light. The DNA from the protected cells can be used in a number of downstream applications including DNA sequencing. The purity (i.e., macromolecules isolated form specific cell types) of such specimens will greatly enhance the value and information of downstream applications. In this method, the specific cells are isolated on a microscope slide using photolithography, which will be faster, more specific, and less expensive than current methods. It relies on the fact that many biological molecules such as DNA are photosensitive and can be destroyed by ultraviolet irradiation. Therefore, it is possible to protect the contents of desired cells, yet destroy undesired cells. This approach leverages the technologies of the microelectronics industry, which can make features smaller than 1 micrometer with photolithography. A variety of ways has been created to achieve identification of the desired cell, and also to designate the other cells for destruction. This can be accomplished through chrome masks, direct laser writing, and also active masking using dynamic arrays. Image recognition is envisioned as one method for identifying cell nuclei and cell membranes. The pathologist can identify the cells of interest using a microscopic computerized image of the slide, and appropriate custom software. In one of the approaches described in this work, the software converts the selection into a digital mask that can be fed into a direct laser writer, e.g. the Heidelberg DWL66. Such a machine uses a metalized glass plate (with chrome metallization) on which there is a thin layer of photoresist. The laser transfers the digital mask onto the photoresist by direct writing, with typical best resolution of 2 micrometers. The plate is then developed to remove the exposed photoresist, which leaves the exposed areas susceptible to chemical chrome etch. The etch removes the unprotected chrome. The rest of the photoresist is then removed, by either ultraviolet organic solvent or over-development. The remaining chrome pattern is quickly oxidized by atmospheric exposure (typically within 30 seconds). The ready chrome mask is now applied to the tissue slide and aligned manually, or using automatic software and pre-designed alignment marks. The slide plate sandwich is then exposed to UV to destroy the DNA of the unwanted cells. The slide and plate are separated and the slide is processed in a standard way to prepare for polymerase chain reaction (PCR) and potential identification of cancer sequences.

Wade, Lawrence A.↗

Extended X-ray absorption fine structure of dynamically-compressed copper up to 1 terapascal

Abstract Large laser facilities have recently enabled material characterization at the pressures of Earth and Super-Earth cores. However, the temperature of the compressed materials has been largely unknown, or solely relied on models and simulations, due to lack of diagnostics under these challenging conditions. Here, we report on temperature, density, pressure, and local structure of copper determined from extended x-ray absorption fine structure and velocimetry up to 1 Terapascal. These results nearly double the highest pressure at which extended x-ray absorption fine structure has been reported in any material. In this work, the copper temperature is unexpectedly found to be much higher than predicted when adjacent to diamond layer(s), demonstrating the important influence of the sample environment on the thermal state of materials; this effect may introduce additional temperature uncertainties in some previous experiments using diamond and provides new guidance for future experimental design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Operating manual holographic interferometry system for 2 x 2 foot transonic wind tunnel

A holographic interferometer system was installed in a 2X2 foot transonic wind tunnel. The system incorporates a modern, 10 pps, Nd:YAG pulsed laser which provides reliable operation and is easy to align. The spatial filtering requirements of the unstable resonator beam are described as well as the integration of the system into the existing Schieren system. A two plate holographic interferometer is used to reconstruct flow field data. For static wind tunnel models the single exposure holograms are recorded in the usual manner; however, for dynamic models such as oscillating airfoils, synchronous laser hologram recording is used.

Craig, J. E.↗

Hot Carrier Dynamics in the X Valley in Si and Ge Measured by Pump-IR-Probe Absorption Spectroscopy

Si is the semiconductor of choice for nanoelectronic roadmap into the next century for computer and other nanodevices. With growing interest in Si, Ge, and Si(sub m)Ge(sub n) strained superlattices, knowledge of the carrier relaxation processes in these materials and structures has become increasingly important. The limited time resolution for earlier studies of carrier dynamics in Ge and Si, performed using Nd:glass lasers, was not sufficient to observe the fast cooling processes. In this paper, we present a direct measurement of hot carrier dynamics in the satellite X valley in Si and Ge by time-resolved infrared(IR) absorption spectroscopy, and show the potential of our technique to identify whether the X valley is the lowest conduction valley in semiconductor materials and structures.

Wang, W. B.↗

Nd:YAG holographic interferometer for aerodynamic research

A holographic interferometer system has been installed in the NASA Ames 2- by 2-Foot Transonic Wind Tunnel. The system incorporates a modern 10 pps, Nd:YAG pulsed laser which provides reliable operation and is easy to align. The spatial filtering requirements of the unstable resonator beam are described, as well as the integration of the system into the existing schlieren system. A two-plate holographic interferometer is used to reconstruct flow field data. For static wind tunnel models, the single exposure holograms are recorded in the usual manner; however, for dynamic models such as oscillating airfoils, synchronous laser hologram recording is used.

Craig, J. E.↗

A New Laser Beam Pointing Method Using Laser Arrays

A new method is described for optical data transmissions from satellites using laser arrays for laser beam pointing. It combines a lens system and a vertical-cavity surface-emitting laser (VCSEL)/Photodetector Array, both mature technologies, in a novel way. This system is applied to satellites in low-Earth orbit, (LEO). It can replace current architectures which use dynamical systems, (i.e., moving parts) to point the laser, and which may use vibration isolation platforms. Results of computer simulations show diffraction limited beam propagation. Possible additional applications are to planetary distances (deep space optical communications, (DSOC)), to optical multiple access, (OMA), to communication between a constellation of close satellites, and to satellites that use modulating retro-reflectors. Keywords: laser beam pointing, free-space optical communication, low-Earth orbit (LEO) data communications, integrated VCSEL/ photodetector arrays, deep space optical communications (DSOC), optical multiple access (OMA), constellation of close satellites, modulating retro-reflectors.

Goorjian, P. M.↗

Particle flow in blade passages of turbomachinery with application to laser-Doppler velocimetry

A theoretical analysis was conducted of the dynamic behavior of micron size particles entrained in gas flow on the two-dimensional blade-to-blade surface of a circular stationary cascade of turbine stator blades. The particle velocity lag and angular deviation relative to the gas was determined as a function of particle diameter and mass density. Particles size and density were varied over ranges selected to correspond to typical laser-Doppler velocimeter (LDV) flow field mapping applications. It was found that velocity lag and angular deviation increased whenever particle size or mass density increased, and that particle tracking was more sensitive to a change in particle diameter than to a change in mass density. Results indicated that LDV applications employing 1 gm/cc tracer particles with diameters greater than approximately 1 micron, or 0.5 micron diameter particles with mass densities greater than 4 gm/cc would experience velocity and angular deviations generally greater than 2 percent and 1 degree, respectively.

Maxwell, B. R.↗