QSCOUT: An Open Quantum Computing Testbed with Low-Level Access to the Hardware and Software (Part I).
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Trace-level measurements of iodine’s isotopic ( 129 I and 127 I) and chemical species distributions are needed for an accurate understanding of radioiodine migration in the Hanford subsurface. Pacific Northwest National Laboratory (PNNL) previously developed a novel analytical method for iodine characterization that uses ion chromatography (IC) coupled to inductively coupled mass spectrometry (ICP-MS). While the method can measure speciated forms of 129 I at levels below the drinking water standard, an interference from molybdenum (Mo) prevents the assay from quantifying the $\underline{total}$ 129 I concentration in many Hanford sample matrices. In this work, solvent extraction was evaluated as a sample preparation method for eliminating the Mo interference. A series of 10 experiments was conducted in which solutions containing known amounts of iodate or iodide were treated by solvent extraction, and the extracted solutions were analyzed for total iodine concentrations by ICP MS. Several extraction parameters such as reagent concentrations and chemical reaction times were systematically adjusted in attempts to optimize the extraction process. While solvent extraction was shown to be effective at removing Mo, there was a consistent inability to recover more than approximately 75% of the total iodine in most experiments. This would reduce the ability to detect 129 I at levels near the drinking water standard. Additionally, the extraction efficiencies in several experiments were highly variable, suggesting that solvent extraction could add significant uncertainty to radioiodine measurements. We recommend evaluating ion exchange as an alternative sample preparation approach in fiscal year (FY) 2024.
In accordance with DOE M 435.1-1 requirements and as implemented by DOE/RL-2000-29, the U.S. Department of Energy (DOE), Richland Operations Office has prepared this annual summary for fiscal year (FY) 2023 for maintenance of the Hanford Site Composite Analysis reported in DOE/RL-2019-52 (hereinafter referred to as the updated Hanford Site Composite Analysis). This is the first annual summary report to transition from maintenance of the initial Hanford Site Composite Analysis reported in PNNL-11800 and PNNL-11800, Addendum 1 to maintenance of the updated Hanford Site Composite Analysis following DOE approval of that update.
Explore the source record for details and available documents.
During a recent revision to the groundwater and inadvertent human intruder screening analysis report (Aleman and Hamm, 2023), weaknesses within the screening logic were observed resulting in the addition of U-235 being brought back into the list of radionuclides requiring inventory limits within the Paducah Cask special waste form (SWF). In addition, while reviewing the earlier vadose zone transport analysis efforts, an inconsistency was observed in the initial U-235P inventory that was supplied to the Consolidated Waste Tracking System (CWTS) back in 2009.
During a recent revision to the groundwater (GW) and inadvertent human intruder (IHI) screening analysis report (Aleman and Hamm, 2023), weaknesses within the screening logic were observed resulting in U-235 being brought back into the list of radionuclides requiring inventory limits within the M-Area Glass SWF. In addition, while reviewing the earlier vadose zone (VZ) transport analysis efforts, an input deck error was observed in the U-234G VZ transport simulation.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Geomagnetic variations from van allen belt ring currents
Problems associated with testing accelerometers to an accuracy where the standard error is less than .0000001 g are centered around the elimination of uncertainties in the acceleration input to the accelerometer. By placing a test rig in free fall, the uncertainty in the earths gravity field can be eliminated.
Rocket smoke-trail wind measurement technique
Microwave mixing in paramagnetic crystal using traveling wave maser with ruby as mixer element, noting frequency conversion
Flight test of electrostatic accelerometer which eliminates null bias problem
Explore the source record for details and available documents.
Detecting pulse signals in insulation systems from application of alternating voltage